메뉴 건너뛰기




Volumn 26, Issue 6, 2011, Pages 1273-1278

A radiographic study of the position and prevalence of the maxillary arterial endosseous anastomosis using cone beam computed tomography

Author keywords

Cone beam computed tomography; Maxillary artery; Maxillary sinus; Sinus elevation

Indexed keywords

ADULT; AGED; ANALYSIS OF VARIANCE; ARTICLE; CONE BEAM COMPUTED TOMOGRAPHY; FACIAL BONE; FEMALE; HISTOLOGY; HUMAN; JAW; MALE; MAXILLARY ARTERY; MAXILLARY SINUS; MIDDLE AGED; NONPARAMETRIC TEST; RADIOGRAPHY; REFERENCE VALUE; VASCULARIZATION;

EID: 84863217980     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (43)

References (15)
  • 1
    • 40449090983 scopus 로고    scopus 로고
    • Dental implants placed in grafted maxillary sinuses: A retrospective analysis of clinical outcome according to the initial clinical situation and a proposal of defect classification
    • Chiapasco M, Zaniboni M, Rimondini L. Dental implants placed in grafted maxillary sinuses: A retrospective analysis of clinical outcome according to the initial clinical situation and a proposal of defect classification. Clin Oral Implants Res 2008;19:416-428.
    • (2008) Clin Oral Implants Res , vol.19 , pp. 416-428
    • Chiapasco, M.1    Zaniboni, M.2    Rimondini, L.3
  • 3
    • 67649397320 scopus 로고    scopus 로고
    • Cone-beam computerized tomography (CBCT) imaging of the oral and maxillofacial region:A systematic review of the literature
    • De Vos W, Casselman J, Swennen GR. Cone-beam computerized tomography (CBCT) imaging of the oral and maxillofacial region:A systematic review of the literature. Int J Oral Maxillofac Surg 2009;38:609-625.
    • (2009) Int J Oral Maxillofac Surg , vol.38 , pp. 609-625
    • De Vos, W.1    Casselman, J.2    Swennen, G.R.3
  • 6
    • 77649219143 scopus 로고    scopus 로고
    • The effect of piezoelectric use on open sinus lift perforation: A retrospective evaluation of 56 consecutively treated cases from private practices
    • Toscano NJ, Holtzclaw D, Rosen PS. The effect of piezoelectric use on open sinus lift perforation: A retrospective evaluation of 56 consecutively treated cases from private practices. J Periodontol 2010;81:167-171.
    • (2010) J Periodontol , vol.81 , pp. 167-171
    • Toscano, N.J.1    Holtzclaw, D.2    Rosen, P.S.3
  • 9
    • 34447638887 scopus 로고    scopus 로고
    • Prevalence, diameter and course of the maxillary intraosseous vascular canal with relation to sinus augmentation procedure: A radiographic study
    • Mardinger O, Abba M, Hirshberg A, Schwartz-Arad D. Prevalence, diameter and course of the maxillary intraosseous vascular canal with relation to sinus augmentation procedure: A radiographic study. Int J Oral Maxillofac Surg 2007;36:735-738.
    • (2007) Int J Oral Maxillofac Surg , vol.36 , pp. 735-738
    • Mardinger, O.1    Abba, M.2    Hirshberg, A.3    Schwartz-Arad, D.4
  • 11
    • 66149118646 scopus 로고    scopus 로고
    • Vascular connections of the lateral wall of the sinus: Surgical effect in sinus augmentation
    • Ella B, Sedarat C, Noble Rda C, et al. Vascular connections of the lateral wall of the sinus: Surgical effect in sinus augmentation. Int J Oral Maxillofac Implants 2008;23:1047-1052.
    • (2008) Int J Oral Maxillofac Implants , vol.23 , pp. 1047-1052
    • Ella, B.1    Sedarat, C.2    Noble Rda, C.3
  • 12
    • 77953502267 scopus 로고    scopus 로고
    • Brisk, prolonged pulsatile hemorrhage during the sinus graft procedure: A case report with discussion on intra-operative hemostatic management
    • Lee CY. Brisk, prolonged pulsatile hemorrhage during the sinus graft procedure: A case report with discussion on intra-operative hemostatic management. Implant Dent 2010;19:189-195.
    • (2010) Implant Dent , vol.19 , pp. 189-195
    • Lee, C.Y.1
  • 14
    • 33748518930 scopus 로고    scopus 로고
    • Accuracy of cone beam computed tomography for periodontal defect measurements
    • Misch KA, Yi ES, Sarment DP. Accuracy of cone beam computed tomography for periodontal defect measurements. J Periodontol 2006;77:1261-1266.
    • (2006) J Periodontol , vol.77 , pp. 1261-1266
    • Misch, K.A.1    Yi, E.S.2    Sarment, D.P.3
  • 15
    • 14244264415 scopus 로고    scopus 로고
    • Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom)
    • Lascala CA, Panella J, Marques MM. Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom). Dentomaxillofac Radiol 2004;33:291-294-.
    • (2004) Dentomaxillofac Radiol , vol.33 , pp. 291-294
    • Lascala, C.A.1    Panella, J.2    Marques, M.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.