메뉴 건너뛰기




Volumn 3, Issue 4, 2010, Pages 295-310

Increasing the indoor humidity levels in buildings with ventilation systems: Simulation aided design in case of passive houses

Author keywords

buffering material; indoor humidity level; simulation; ventilation rate

Indexed keywords


EID: 84862997375     PISSN: 19963599     EISSN: 19968744     Source Type: Journal    
DOI: 10.1007/s12273-010-0015-2     Document Type: Article
Times cited : (32)

References (17)
  • 3
    • 0003009405 scopus 로고    scopus 로고
    • Impact of temperature and humidity on the perception of indoor air quality during immediate and longer whole-body exposures
    • Fang L, Clausen G, Fanger PO (1998a). Impact of temperature and humidity on the perception of indoor air quality during immediate and longer whole-body exposures. Indoor Air, 8: 276-284.
    • (1998) Indoor Air , vol.8 , pp. 276-284
    • Fang, L.1    Clausen, G.2    Fanger, P.O.3
  • 5
    • 0003009404 scopus 로고    scopus 로고
    • Impact of temperature and humidity on the perception of indoor air quality
    • Fang L, Clausen G, Fanger PO (1998b). Impact of temperature and humidity on the perception of indoor air quality. Indoor Air, 8: 80-90.
    • (1998) Indoor Air , vol.8 , pp. 80-90
    • Fang, L.1    Clausen, G.2    Fanger, P.O.3
  • 7
    • 77950502464 scopus 로고    scopus 로고
    • Transformation of fundamental parameters for energy demand and indoor temperature from room level to building level
    • Korjenic A, Bednar T (2010). Transformation of fundamental parameters for energy demand and indoor temperature from room level to building level. Journal of Building Physics, 33: 327-355.
    • (2010) Journal of Building Physics , vol.33 , pp. 327-355
    • Korjenic, A.1    Bednar, T.2
  • 9
    • 35348964642 scopus 로고
    • NBN D 50-001, Belgian Standard. Brussels
    • NBN D 50-001 (1991). Ventilation systems for housings. Belgian Standard. Brussels.
    • (1991) Ventilation systems for housings
  • 11
    • 33745357635 scopus 로고    scopus 로고
    • Moisture buffering capacity of hygroscopic building materials: Experimental facilities and energy impact
    • Osanyintola OF, Simonson CJ (2006). Moisture buffering capacity of hygroscopic building materials: Experimental facilities and energy impact. Energy and Buildings, 38: 1270-1282.
    • (2006) Energy and Buildings , vol.38 , pp. 1270-1282
    • Osanyintola, O.F.1    Simonson, C.J.2
  • 13
    • 0003446278 scopus 로고    scopus 로고
    • Germany: Fakultät Bauingenieur-und Vermessungswesen, Universität Stuttgart
    • Sedlbauer K (2001). Vorhersage von Schimmelpilzbildung auf und in Bauteilen. PhD Dissertation, Fakultät Bauingenieur-und Vermessungswesen, Universität Stuttgart, Germany. (in German).
    • (2001) Vorhersage Von Schimmelpilzbildung Auf Und in Bauteilen
    • Sedlbauer, K.1
  • 14
    • 0036984380 scopus 로고    scopus 로고
    • The effect of structures on indoor humidity: possibility to improve comfort and perceived air quality
    • Simonson CJ, Salonvaara M, Ojanen T (2002). The effect of structures on indoor humidity: possibility to improve comfort and perceived air quality. Indoor Air, 12: 243-251.
    • (2002) Indoor Air , vol.12 , pp. 243-251
    • Simonson, C.J.1    Salonvaara, M.2    Ojanen, T.3
  • 15
    • 4944238599 scopus 로고    scopus 로고
    • Moderating indoor conditions with hygroscopic building materials and outdoor venitlation
    • Simonson CJ, Salonvaara M, Ojanen T (2004). Moderating indoor conditions with hygroscopic building materials and outdoor venitlation. ASHRAE Transactions, 110(2): 804-819.
    • (2004) ASHRAE Transactions , vol.110 , Issue.2 , pp. 804-819
    • Simonson, C.J.1    Salonvaara, M.2    Ojanen, T.3
  • 16
    • 0032137599 scopus 로고    scopus 로고
    • Upper limits of air humidity for preventing warm respiratory discomfort
    • Toftum J, Jørgensen AS, Fanger PO (1998). Upper limits of air humidity for preventing warm respiratory discomfort. Energy and Buildings, 28: 15-23.
    • (1998) Energy and Buildings , vol.28 , pp. 15-23
    • Toftum, J.1    Jørgensen, A.S.2    Fanger, P.O.3
  • 17
    • 33744501238 scopus 로고    scopus 로고
    • Experimental determination of the limiting criteria for human exposure to low winter humidity indoors
    • Wyon DP, Lagercrantz L, Fang L, Fanger PO (2006). Experimental determination of the limiting criteria for human exposure to low winter humidity indoors. HVAC&R Research, 12: 201-213.
    • (2006) HVAC&R Research , vol.12 , pp. 201-213
    • Wyon, D.P.1    Lagercrantz, L.2    Fang, L.3    Fanger, P.O.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.