메뉴 건너뛰기




Volumn 38, Issue 10, 2006, Pages 1270-1282

Moisture buffering capacity of hygroscopic building materials: Experimental facilities and energy impact

Author keywords

Convective transfer coefficients; Energy savings; Experimental facility; Indoor air quality; Moisture buffering capacity; Spruce plywood; Uncertainty

Indexed keywords

ATMOSPHERIC HUMIDITY; COOLING SYSTEMS; ENVIRONMENTAL IMPACT; HEAT CONVECTION; INDOOR AIR POLLUTION; MOISTURE;

EID: 33745357635     PISSN: 03787788     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enbuild.2006.03.026     Document Type: Article
Times cited : (328)

References (48)
  • 1
    • 33745428668 scopus 로고    scopus 로고
    • Effect of initial conditions, boundary conditions and thickness on the moisture buffering capacity of spruce plywood
    • Osanyintola O.F., Talukdar P., and Simonson C.J. Effect of initial conditions, boundary conditions and thickness on the moisture buffering capacity of spruce plywood. Energy and Buildings 38 10 (2006) 1283-1292
    • (2006) Energy and Buildings , vol.38 , Issue.10 , pp. 1283-1292
    • Osanyintola, O.F.1    Talukdar, P.2    Simonson, C.J.3
  • 2
    • 0032137599 scopus 로고    scopus 로고
    • Upper limits of air humidity for preventing warm respiratory discomfort
    • Toftum J., Jorgensen A.S., and Fanger P.O. Upper limits of air humidity for preventing warm respiratory discomfort. Energy and Buildings 28 (1998) 15-23
    • (1998) Energy and Buildings , vol.28 , pp. 15-23
    • Toftum, J.1    Jorgensen, A.S.2    Fanger, P.O.3
  • 3
    • 0032141975 scopus 로고    scopus 로고
    • Upper limits for indoor air humidity to avoid uncomfortably humid skin
    • Toftum J., Jorgensen A.S., and Fanger P.O. Upper limits for indoor air humidity to avoid uncomfortably humid skin. Energy and Buildings 28 (1998) 1-13
    • (1998) Energy and Buildings , vol.28 , pp. 1-13
    • Toftum, J.1    Jorgensen, A.S.2    Fanger, P.O.3
  • 4
    • 0003009404 scopus 로고    scopus 로고
    • Impact of temperature and humidity on the perception of indoor air quality
    • Fang L., Clausen G., and Fanger P.O. Impact of temperature and humidity on the perception of indoor air quality. Indoor Air 8 (1998) 80-90
    • (1998) Indoor Air , vol.8 , pp. 80-90
    • Fang, L.1    Clausen, G.2    Fanger, P.O.3
  • 6
    • 0036532694 scopus 로고    scopus 로고
    • Study of moisture in buildings for hot humid climates
    • Lucas F., Adelard L., Garde F., and Boyer H. Study of moisture in buildings for hot humid climates. Energy and Buildings 34 (2002) 345-355
    • (2002) Energy and Buildings , vol.34 , pp. 345-355
    • Lucas, F.1    Adelard, L.2    Garde, F.3    Boyer, H.4
  • 7
    • 2942638071 scopus 로고    scopus 로고
    • Real-time determination of optimal indoor-air condition for thermal comfort, air quality and efficient energy usage, upper limits for indoor air humidity to avoid uncomfortably humid skin
    • Atthajariyakul S., and Leephakpreeda T. Real-time determination of optimal indoor-air condition for thermal comfort, air quality and efficient energy usage, upper limits for indoor air humidity to avoid uncomfortably humid skin. Energy and Buildings 36 7 (2004) 720-733
    • (2004) Energy and Buildings , vol.36 , Issue.7 , pp. 720-733
    • Atthajariyakul, S.1    Leephakpreeda, T.2
  • 8
    • 13244268531 scopus 로고    scopus 로고
    • Assessing the thermal performance of an emergency shelter system
    • Crawford C., Manfield P., and McRobie A. Assessing the thermal performance of an emergency shelter system. Energy and Buildings 37 5 (2005) 471-483
    • (2005) Energy and Buildings , vol.37 , Issue.5 , pp. 471-483
    • Crawford, C.1    Manfield, P.2    McRobie, A.3
  • 9
    • 27744603719 scopus 로고    scopus 로고
    • J. Arias, P. Lundqvist, Heat recovery and floating condensing in supermarkets, Energy and Buildings 38 (2) (2006) 73-81.
  • 10
    • 1842538293 scopus 로고    scopus 로고
    • An evaluation of silica gel for humidity control in display cases
    • Yu D., Klein S.A., and Reindl D.T. An evaluation of silica gel for humidity control in display cases. WAAC Newsletter 23 2. (2001)
    • (2001) WAAC Newsletter , vol.23 , Issue.2
    • Yu, D.1    Klein, S.A.2    Reindl, D.T.3
  • 11
    • 8744312230 scopus 로고    scopus 로고
    • C.J. Simonson, M. Salonvaara, T. Ojanen, Improving indoor climate and comfort with wooden structures, VTT Building Technology, Espoo: VTT Publications 431, http://virtual.vtt.fi/inf/pdf/publications/2001/P431.pdf, VTT Building and Transport, 2001.
  • 12
    • 4944238599 scopus 로고    scopus 로고
    • Moderating indoor conditions with hygroscopic building materials and outdoor ventilation
    • Simonson C.J., Salonvaara M., and Ojanen T. Moderating indoor conditions with hygroscopic building materials and outdoor ventilation. ASHRAE Transactions 110 2 (2004) 804-819
    • (2004) ASHRAE Transactions , vol.110 , Issue.2 , pp. 804-819
    • Simonson, C.J.1    Salonvaara, M.2    Ojanen, T.3
  • 14
    • 3142776207 scopus 로고    scopus 로고
    • Heat and mass transfer between indoor air and a permeable and hygroscopic building envelope. Part I. Field measurements
    • Simonson C.J., Salonvaara M., and Ojanen T. Heat and mass transfer between indoor air and a permeable and hygroscopic building envelope. Part I. Field measurements. Journal of Thermal Envelope and Building Science 28 1 (2004) 63-101
    • (2004) Journal of Thermal Envelope and Building Science , vol.28 , Issue.1 , pp. 63-101
    • Simonson, C.J.1    Salonvaara, M.2    Ojanen, T.3
  • 15
    • 20344384785 scopus 로고    scopus 로고
    • Predicting indoor temperature and humidity conditions including hygrothermal interactions with the building envelope
    • Holm A.H., Kunzel H.M., and Sedlbauer K. Predicting indoor temperature and humidity conditions including hygrothermal interactions with the building envelope. ASHRAE Transactions 110 2 (2004) 820-826
    • (2004) ASHRAE Transactions , vol.110 , Issue.2 , pp. 820-826
    • Holm, A.H.1    Kunzel, H.M.2    Sedlbauer, K.3
  • 20
    • 21644464868 scopus 로고    scopus 로고
    • Moisture buffering capacity of heavy timber structures directly exposed to an indoor climate: a numerical study
    • Hameury S. Moisture buffering capacity of heavy timber structures directly exposed to an indoor climate: a numerical study. Buildings and Environment 40 (2005) 1400-1412
    • (2005) Buildings and Environment , vol.40 , pp. 1400-1412
    • Hameury, S.1
  • 21
    • 4944245161 scopus 로고    scopus 로고
    • Energy consumption and ventilation performance of a naturally ventilated ecological house in a cold climate
    • Simonson C.J. Energy consumption and ventilation performance of a naturally ventilated ecological house in a cold climate. Energy and Buildings 37 1 (2005) 23-35
    • (2005) Energy and Buildings , vol.37 , Issue.1 , pp. 23-35
    • Simonson, C.J.1
  • 22
    • 10444289964 scopus 로고    scopus 로고
    • Experimental and numerical study on indoor temperature and humidity with free water surface
    • Liu J., Aizawa Y., and Yoshino H. Experimental and numerical study on indoor temperature and humidity with free water surface. Energy and Buildings 37 4 (2005) 383-388
    • (2005) Energy and Buildings , vol.37 , Issue.4 , pp. 383-388
    • Liu, J.1    Aizawa, Y.2    Yoshino, H.3
  • 23
    • 1542531366 scopus 로고    scopus 로고
    • Contribution of indoor exposed massive wood to a good indoor climate: in situ measurement campaign
    • Hameury S., and Lundstrom T. Contribution of indoor exposed massive wood to a good indoor climate: in situ measurement campaign. Energy and Buildings 36 (2004) 281-292
    • (2004) Energy and Buildings , vol.36 , pp. 281-292
    • Hameury, S.1    Lundstrom, T.2
  • 24
    • 18844394777 scopus 로고    scopus 로고
    • Measuring and modeling vapor boundary layer growth during transient diffusion heat and moisture transfer in cellulose insulation
    • Olutimayin S., and Simonson C.J. Measuring and modeling vapor boundary layer growth during transient diffusion heat and moisture transfer in cellulose insulation. International Journal of Heat and Mass Transfer 48 (2005) 3319-3330
    • (2005) International Journal of Heat and Mass Transfer , vol.48 , pp. 3319-3330
    • Olutimayin, S.1    Simonson, C.J.2
  • 27
    • 33745396338 scopus 로고    scopus 로고
    • JIS A 1470-1. Test method of adsorption/desorption efficiency for building materials to regulate an indoor humidity-Part 1: Response method of humidity, Japanese Standards Association, Tokyo, 2002.
  • 28
    • 85059770385 scopus 로고    scopus 로고
    • The relevance of surface properties & wood finishes to the wood science & technology research community
    • Gardner D.J. The relevance of surface properties & wood finishes to the wood science & technology research community. Proceedings of the Second SWST Annual Fundamental Disciplines Session (2004). http://www.swst.org/meetings/AM04/Gardner.pdf
    • (2004) Proceedings of the Second SWST Annual Fundamental Disciplines Session
    • Gardner, D.J.1
  • 29
    • 33745420822 scopus 로고    scopus 로고
    • ISO, Measurement of fluid flow by means of pressure differential devices, ISO 5176-1, Switzerland, 1991.
  • 32
    • 33745420985 scopus 로고    scopus 로고
    • O.F. Osanyintola, Transient moisture characteristics of spruce plywood, M.Sc. Thesis, Department of Mechanical Engineering, University of Saskatchewan, 2005, http://library.usask.ca/theses/available/etd-12222005-082100/.
  • 33
    • 11144302636 scopus 로고    scopus 로고
    • An experimentally simple method for measuring sorption isotherms
    • Wadso L., Svennberg K., and Dueck A. An experimentally simple method for measuring sorption isotherms. Drying Technology 22 10 (2004) 2427-2440
    • (2004) Drying Technology , vol.22 , Issue.10 , pp. 2427-2440
    • Wadso, L.1    Svennberg, K.2    Dueck, A.3
  • 34
    • 33745356658 scopus 로고    scopus 로고
    • ASTM, Standard test method for steady-state heat flux measurement and thermal transmission properties by means of the heat flow meter apparatus, ASTM C 518, Philadelphia, 2003.
  • 35
    • 33745401270 scopus 로고    scopus 로고
    • ASTM, Standard test method for water vapor transmission of materials, ASTM E96/E96M, Philadelphia, 2005.
  • 36
    • 0036984380 scopus 로고    scopus 로고
    • The effect of structures on indoor humidity-possibility to improve comfort and perceived air quality
    • Simonson C.J., Salonvaara M., and Ojanen T. The effect of structures on indoor humidity-possibility to improve comfort and perceived air quality. Indoor Air 12 (2002) 243-251
    • (2002) Indoor Air , vol.12 , pp. 243-251
    • Simonson, C.J.1    Salonvaara, M.2    Ojanen, T.3
  • 38
    • 33745381609 scopus 로고    scopus 로고
    • CEN, Ventilation for buildings-design criteria for the indoor environment, European Committee for Standardization, Report CR 1752, 1988.
  • 39
    • 0004815795 scopus 로고
    • Dynamic modeling of combined thermal and moisture transport in buildings: effect on cooling loads and space conditions
    • Fairey P.W., and Kerestecioglu A.A. Dynamic modeling of combined thermal and moisture transport in buildings: effect on cooling loads and space conditions. ASHRAE Transactions 91 2A (1985) 461-472
    • (1985) ASHRAE Transactions , vol.91 , Issue.2 A , pp. 461-472
    • Fairey, P.W.1    Kerestecioglu, A.A.2
  • 40
    • 0029755684 scopus 로고    scopus 로고
    • A simplified method for determining optimal cooling control strategies for thermal storage in building mass
    • Keeney K., and Braun J.E. A simplified method for determining optimal cooling control strategies for thermal storage in building mass. International Journal of HVAC&R Research 2 1 (1996) 59-78
    • (1996) International Journal of HVAC&R Research , vol.2 , Issue.1 , pp. 59-78
    • Keeney, K.1    Braun, J.E.2
  • 41
    • 0026986279 scopus 로고
    • Heat storage in building thermal mass-a parametric study
    • Andresen I., and Brandemuehl M.J. Heat storage in building thermal mass-a parametric study. ASHRAE Transactions 98 1 (1992) 910-918
    • (1992) ASHRAE Transactions , vol.98 , Issue.1 , pp. 910-918
    • Andresen, I.1    Brandemuehl, M.J.2
  • 42
    • 0025564437 scopus 로고
    • Reducing energy costs and peak electrical demand through optimal control of building thermal storage
    • Braun J.E. Reducing energy costs and peak electrical demand through optimal control of building thermal storage. ASHRAE Transactions 96 2 (1990) 876-888
    • (1990) ASHRAE Transactions , vol.96 , Issue.2 , pp. 876-888
    • Braun, J.E.1
  • 43
    • 33745415602 scopus 로고    scopus 로고
    • ASHRAE, Thermal environmental conditions for human occupancy, ANSI/ASHRAE Standard 55, Atlanta, 2004.
  • 44
    • 6244303935 scopus 로고    scopus 로고
    • What we know, and what don't know about sick building syndrome
    • Sundell J. What we know, and what don't know about sick building syndrome. ASHRAE Journal 38 6 (1996) 51-57
    • (1996) ASHRAE Journal , vol.38 , Issue.6 , pp. 51-57
    • Sundell, J.1
  • 45
    • 0001971506 scopus 로고    scopus 로고
    • Estimated cost of indoor climate in Finnish buildings
    • Edinburgh
    • Seppänen O. Estimated cost of indoor climate in Finnish buildings. Proceedings of the Indoor Air'99, vol. 4. Edinburgh (1999) 13-18
    • (1999) Proceedings of the Indoor Air'99, vol. 4 , pp. 13-18
    • Seppänen, O.1
  • 46
    • 0032683852 scopus 로고    scopus 로고
    • Airflow reduction to improve building comfort and reduce energy consumption-a case study
    • Liu M., Zhu Y., Park B.Y., Claridge D.E., and Feary D.K. Airflow reduction to improve building comfort and reduce energy consumption-a case study. ASHRAE Transactions 105 1 (1999) 384-390
    • (1999) ASHRAE Transactions , vol.105 , Issue.1 , pp. 384-390
    • Liu, M.1    Zhu, Y.2    Park, B.Y.3    Claridge, D.E.4    Feary, D.K.5
  • 48
    • 33745431305 scopus 로고    scopus 로고
    • ASTM, Maintaining constant relative humidity by means of aqueous solutions, ASTM E 104, Philadelphia, 1985.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.