메뉴 건너뛰기




Volumn 14, Issue 7, 2012, Pages 994-1001

Differences in encapsulating lead tissue in patients who underwent transvenous lead removal

Author keywords

Encapsulating lead tissue; Fibrocollagenous sheath; Infective endocarditis; Lead removal; Silicone insulated leads abrasion

Indexed keywords

C REACTIVE PROTEIN; EOSIN; HEMATOXYLIN; HEMOSIDERIN; LEAD; PARAFFIN; PARAFORMALDEHYDE; POLYURETHAN; SILICONE;

EID: 84862982463     PISSN: 10995129     EISSN: 15322092     Source Type: Journal    
DOI: 10.1093/europace/eur384     Document Type: Article
Times cited : (37)

References (50)
  • 1
    • 77955982299 scopus 로고    scopus 로고
    • Infections liées aux pacemakers et défibrillateurs implantables
    • Camus C, Donal E, Bodi S, Tattevin P. Infections liées aux pacemakers et défibrillateurs implantables. Méd maladies infect 2010;40:429-39.
    • (2010) Méd Maladies Infect , vol.40 , pp. 429-439
    • Camus, C.1    Donal, E.2    Bodi, S.3    Tattevin, P.4
  • 2
    • 0033770747 scopus 로고    scopus 로고
    • Diagnostic and management of infections involving implantable electrophysiologic cardiac devices
    • Chua JD, Wilkoff BL, Lee I, Juratli N, Longworth DL, Gordon SMl. Diagnostic and management of infections involving implantable electrophysiologic cardiac devices. Ann Intern Med 2000;133:604-8.
    • (2000) Ann Intern Med , vol.133 , pp. 604-608
    • Chua, J.D.1    Wilkoff, B.L.2    Lee, I.3    Juratli, N.4    Longworth, D.L.5    G, S.L.M.6
  • 4
    • 67549100824 scopus 로고    scopus 로고
    • Transvenous lead extraction: Heart Rhythm Society Expert Consensus on facilities, training, indications, and patient management
    • Wilkoff BL, Love CJ, Byrd CL, Bongiorni MG, Carrillo RG, Crossley GH et al. Transvenous lead extraction: Heart Rhythm Society Expert Consensus on facilities, training, indications, and patient management. Heart Rhythm 2009;6: 1085-104.
    • (2009) Heart Rhythm , vol.6 , pp. 1085-1104
    • Wilkoff, B.L.1    Love, C.J.2    Byrd, C.L.3    Bongiorni, M.G.4    Carrillo, R.G.5    Crossley, G.H.6
  • 5
    • 84055192971 scopus 로고    scopus 로고
    • Pathways for training and accreditation for transvenous lead extraction: A European Heart Rhythm Association position paper
    • Deharo JC, Bongiorni MG, Rozcovec A, Bracke F, Defaye P, Fernandez-Lozano I et al.. Pathways for training and accreditation for transvenous lead extraction: a European Heart Rhythm Association position paper. Europace 2011;14:124-34.
    • (2011) Europace , vol.14 , pp. 124-134
    • Deharo, J.C.1    Bongiorni, M.G.2    Rozcovec, A.3    Bracke, F.4    Defaye, P.5    Fernandez-Lozano, I.6
  • 6
    • 0020132822 scopus 로고
    • Ultrastructural alterations in the fibrous sheath, endocardium, and myocardium of dogs shocked with chronically implanted automatic defibrillator leads
    • Van Vleet JF, Ferrans VJ, Barker MA, Tacker W Jr, Bourland JD, Schollmeyer MP. Ultrastructural alterations in the fibrous sheath, endocardium, and myocardium of dogs shocked with chronically implanted automatic defibrillator leads. Am J Vet Res 1982;43:909-15.
    • (1982) Am J Vet Res , vol.43 , pp. 909-915
    • Van Vleet, J.F.1    Ferrans, V.J.2    Barker, M.A.3    Tacker Jr., W.4    Bourland, J.D.5    Schollmeyer, M.P.6
  • 7
    • 0016273357 scopus 로고
    • Myocardial necrosis from direct current countershock: Effect of paddle electrode size and time interval between discharges
    • Dahl CF, Ewy GA, Warner ED, Thomas ED. Myocardial necrosis from direct current countershock: effect of paddle electrode size and time interval between discharges. Circulation 1974;50:956-61.
    • (1974) Circulation , vol.50 , pp. 956-961
    • Dahl, C.F.1    Ewy, G.A.2    Warner, E.D.3    Thomas, E.D.4
  • 9
    • 0024235901 scopus 로고
    • Paired comparisions of steroid-eluting and nonsteroid endocardial pacemaker leads in dogs: Electrical performance and morphologic alterations
    • Radovsky AS, Van Vleet JF, Stokes KB, Tacker WA. Paired comparisions of steroid-eluting and nonsteroid endocardial pacemaker leads in dogs: electrical performance and morphologic alterations. Pacing Clin Eelectrophysiol 1988;11: 1085-93.
    • (1988) Pacing Clin Eelectrophysiol , vol.11 , pp. 1085-1093
    • Radovsky, A.S.1    Van Vleet, J.F.2    Stokes, K.B.3    Tacker, W.A.4
  • 10
    • 0024339068 scopus 로고
    • Effects of dexamethasone elution on tissue reaction around stimulating electrodes of endocardial pacing leads in dogs
    • Radovsky AS, Van Vleet JF. Effects of dexamethasone elution on tissue reaction around stimulating electrodes of endocardial pacing leads in dogs. Am Heart J 1989;117:1288-97.
    • (1989) Am Heart J , vol.117 , pp. 1288-1297
    • Radovsky, A.S.1    Van Vleet, J.F.2
  • 11
    • 0029120291 scopus 로고
    • The encapsulation of polyurethane-insulated transvenous cardiac pacemaker leads
    • Stokes K, Anderson J, McVenes R, McClay C. The encapsulation of polyurethane-insulated transvenous cardiac pacemaker leads. Cardiovasc Pathol 1995;4:163-71.
    • (1995) Cardiovasc Pathol , vol.4 , pp. 163-171
    • Stokes, K.1    Anderson, J.2    McVenes, R.3    McClay, C.4
  • 14
    • 0015380386 scopus 로고
    • Surface thrombosis and fibrous encapsulation of intravenous pacemaker catheter electrode
    • Becker AE, Becker MJ, Claudon DG, Edwards JE. Surface thrombosis and fibrous encapsulation of intravenous pacemaker catheter electrode. Circulation 1972;46: 409-12.
    • (1972) Circulation , vol.46 , pp. 409-412
    • Becker, A.E.1    Becker, M.J.2    Claudon, D.G.3    Edwards, J.E.4
  • 15
    • 0023179553 scopus 로고
    • Pathologic findings related to the lead system and repeated defibrillations in patients with the automatic implantable cardioverter- defibrillator
    • Singer I, Hutchins GM, Mirowski M, Mower MM, Veltri EP, Guarnieri T et al. Pathologic findings related to the lead system and repeated defibrillations in patients with the automatic implantable cardioverter-defibrillator. J Am Coll Cardiol 1987;10:382-8.
    • (1987) J Am Coll Cardiol , vol.10 , pp. 382-388
    • Singer, I.1    Hutchins, G.M.2    Mirowski, M.3    Mower, M.M.4    Veltri, E.P.5    Guarnieri, T.6
  • 16
    • 0032514609 scopus 로고    scopus 로고
    • Gross and microscopic pathological changes associated with nonthoracotomy implantable defibrillator leads
    • Epstein AE, Kay GN, Plumb VJ, Dailey SM, Anderson PG. Gross and microscopic pathological changes associated with nonthoracotomy implantable defibrillator leads. Circulation 1998;98:1517-24.
    • (1998) Circulation , vol.98 , pp. 1517-1524
    • Epstein, A.E.1    Kay, G.N.2    Plumb, V.J.3    Dailey, S.M.4    Anderson, P.G.5
  • 18
    • 70449344705 scopus 로고    scopus 로고
    • Autopsy and clinical context in deceased patients with implanted pacemakers and defibrillators: Intracardiac findings near their leads and electrodes
    • Novak M, Dvorak P, Kamaryt P, Slana B, Lipoldova J. Autopsy and clinical context in deceased patients with implanted pacemakers and defibrillators: intracardiac findings near their leads and electrodes. Europace 2009;11:1510-6.
    • (2009) Europace , vol.11 , pp. 1510-1516
    • Novak, M.1    Dvorak, P.2    Kamaryt, P.3    Slana, B.4    Lipoldova, J.5
  • 19
    • 0023235324 scopus 로고
    • Cardioversion and defibrillation using a catheter electrode: Myocardial damage assessed at autopsy
    • Perkins DG, Klein GJ. Cardioversion and defibrillation using a catheter electrode: myocardial damage assessed at autopsy. Pacing Clin Electrophysiol 1987; 10:800-4.
    • (1987) Pacing Clin Electrophysiol , vol.10 , pp. 800-804
    • Perkins, D.G.1    Klein, G.J.2
  • 20
    • 84863004763 scopus 로고    scopus 로고
    • Studies of the tissue reaction induced by transvenous pacemaker electrodes. I. Microscopic examination of the extent of connective tissue around the electrode tip in the human right ventricle
    • Beyersdorf F. Studies of the tissue reaction induced by transvenous pacemaker electrodes. I. Microscopic examination of the extent of connective tissue around the electrode tip in the human right ventricle. Pacing Clin Electrophysiol 1998;11:10753-9.
    • (1998) Pacing Clin Electrophysiol , vol.11 , pp. 10753-10759
    • Beyersdorf, F.1
  • 21
    • 0020507448 scopus 로고
    • Postmortem findings and possible causes of unexpected death in patients treated with intraventricular pacing
    • Rajs J. Postmortem findings and possible causes of unexpected death in patients treated with intraventricular pacing. Pacing Clin Electrophysiol 1983;6:751-60.
    • (1983) Pacing Clin Electrophysiol , vol.6 , pp. 751-760
    • Rajs, J.1
  • 23
    • 0036380363 scopus 로고    scopus 로고
    • Morphologic and immunohistochemical observations of tissues surrounding retrived transvenous pacemaker leads
    • Esposito M, Kennergren C, Holmström N, Nilsson S, Eckerdal J, Thomsen P. Morphologic and immunohistochemical observations of tissues surrounding retrived transvenous pacemaker leads. J Biomed Mater Res 2002;63:548-58.
    • (2002) J Biomed Mater Res , vol.63 , pp. 548-558
    • Esposito, M.1    Kennergren, C.2    Holmström, N.3    Nilsson, S.4    Eckerdal, J.5    Thomsen, P.6
  • 24
    • 0021800094 scopus 로고
    • Morphological changes in human myocardium during permanent pacing
    • Châtelain P, Adamec R, Cox JN. Morphological changes in human myocardium during permanent pacing. Virchows Arch (Pathol Anat) 1985;407:43-57.
    • (1985) Virchows Arch (Pathol Anat) , vol.407 , pp. 43-57
    • Châtelain, P.1    Adamec, R.2    Cox, J.N.3
  • 25
    • 0032971951 scopus 로고    scopus 로고
    • Postmortem analysis of encapsulation around long-term ventricular endocardial pacing leads
    • Candinas R, Duru F, Schneider J, Luscher TF, Stokes K. Postmortem analysis of encapsulation around long-term ventricular endocardial pacing leads. Mayo Clin Proc 1999;74:120-5.
    • (1999) Mayo Clin Proc , vol.74 , pp. 120-125
    • Candinas, R.1    Duru, F.2    Schneider, J.3    Luscher, T.F.4    Stokes, K.5
  • 26
    • 0001012722 scopus 로고
    • Cardiovascular tissue response to intracardiac pacemaking
    • Legergren H, Dahlgren S, Nordenstam H. Cardiovascular tissue response to intracardiac pacemaking. Acta Chir Scand 1966;132:696-704.
    • (1966) Acta Chir Scand , vol.132 , pp. 696-704
    • Legergren, H.1    Dahlgren, S.2    Nordenstam, H.3
  • 28
    • 0018731050 scopus 로고
    • Superior vena cava stenosis at site of insertion of two pacing electrodes
    • Pauletti M, Pingitore R, Contini C. Superior vena cava stenosis at site of insertion of two pacing electrodes. Br Heart J 1979;42:487-9.
    • (1979) Br Heart J , vol.42 , pp. 487-489
    • Pauletti, M.1    Pingitore, R.2    Contini, C.3
  • 30
    • 21844440862 scopus 로고    scopus 로고
    • Histopathological study of tissue reaction to pacemaker electrodes implanted in the endocardium
    • Mase H, Tamura K, Hiromoto A, Hotta M, Hotomi S, Togashi M et al. Histopathological study of tissue reaction to pacemaker electrodes implanted in the endocardium. J Nippon Med Sch 2005;72:52-9.
    • (2005) J Nippon Med Sch , vol.72 , pp. 52-59
    • Mase, H.1    Tamura, K.2    Hiromoto, A.3    Hotta, M.4    Hotomi, S.5    Togashi, M.6
  • 32
    • 85060964726 scopus 로고    scopus 로고
    • Ko?odzińska A, Kutarski A, Grabowski M, Jarzyna I, Ma?ecka B, Opolski G. Abrasions of the outer silicone insulation of endocardial leads in their intracardiac part-the new mechanism of lead-dependent endocarditis. Europace (forthcoming).
    • Ko?odzińska A, Kutarski A, Grabowski M, Jarzyna I, Ma?ecka B, Opolski G. Abrasions of the outer silicone insulation of endocardial leads in their intracardiac part-the new mechanism of lead-dependent endocarditis. Europace (forthcoming).
  • 33
    • 9244255528 scopus 로고    scopus 로고
    • Morfologiczne aspekty jednojamowej prawokomorowej sta?ej stymulacji serca. Cze?ść II: Zmiany odczynowo-w?óknikowe w aspekcie rozwoju niedomykalnos ́ci tró jdzielnej
    • Koz?owski D, Krupa W, Koz?luk E, Dubaniewicz A, Grzybiak M, Adamowicz M et al. Morfologiczne aspekty jednojamowej prawokomorowej sta?ej stymulacji serca. Cze?ść II: Zmiany odczynowo-w?óknikowe w aspekcie rozwoju niedomykalnos ́ci tró jdzielnej. Folia Cardiol 2000;2:105-10.
    • (2000) Folia Cardiol , vol.2 , pp. 105-110
    • Kozowski, D.1    Krupa, W.2    Kozluk, E.3    Dubaniewicz, A.4    Grzybiak, M.5    Adamowicz, M.6
  • 34
    • 0032833413 scopus 로고    scopus 로고
    • Stimulation of coronary vasculogenesis/angiogenesis by hypoxia in cultured embryonic hearts
    • Yue X, Tomanek RJ. Stimulation of coronary vasculogenesis/angiogenesis by hypoxia in cultured embryonic hearts. Dev Dyn 1999;216:28-36.
    • (1999) Dev Dyn , vol.216 , pp. 28-36
    • Yue, X.1    Tomanek, R.J.2
  • 35
    • 0032996753 scopus 로고    scopus 로고
    • Ectopic calcification. Gathering hard facts about soft tissue mineralization
    • Giachelli C. Ectopic calcification. Gathering hard facts about soft tissue mineralization. Ame J Pathol 1999;154:671-5.
    • (1999) Ame J Pathol , vol.154 , pp. 671-675
    • Giachelli, C.1
  • 36
    • 84861618264 scopus 로고    scopus 로고
    • The reliability of modern pacing leads
    • Ebert MJ, Stokes KB, McVenes R. The reliability of modern pacing leads. Ther Res 1999;20:295-301.
    • (1999) Ther Res , vol.20 , pp. 295-301
    • Ebert, M.J.1    Stokes, K.B.2    McVenes, R.3
  • 38
    • 0028346048 scopus 로고
    • Pacemaker contact sensitivity: Clinical recognition and management
    • Abdallah HI, Balsara RK, O'Riordan AC. Pacemaker contact sensitivity: clinical recognition and management. Ann Thorac Surg 1994;57:1017-8.
    • (1994) Ann Thorac Surg , vol.57 , pp. 1017-1018
    • Abdallah, H.I.1    Balsara, R.K.2    O'Riordan, A.C.3
  • 39
    • 0036630491 scopus 로고    scopus 로고
    • Pacemaker component allergy: Case report and review of the literature
    • Hayes DL, Loesl K. Pacemaker component allergy: case report and review of the literature. J Interv Card Electrophysiol 2002;6:277-8.
    • (2002) J Interv Card Electrophysiol , vol.6 , pp. 277-278
    • Hayes, D.L.1    Loesl, K.2
  • 40
    • 85047696707 scopus 로고    scopus 로고
    • Biodegradation of polyether polyurethane inner insulation in bipolar pacemaker leads
    • Wiggins MJ,Wilkoff B, Anderson JM, Hiltner A. Biodegradation of polyether polyurethane inner insulation in bipolar pacemaker leads. J BiomedMater Res 2001;58:302-7.
    • (2001) J BiomedMater Res , vol.58 , pp. 302-307
    • Wiggins Mjwilkoff, B.1    Anderson, J.M.2    Hiltner, A.3
  • 41
    • 33845487923 scopus 로고    scopus 로고
    • In vivo biostability of polyether polyurethanes with fluoropolymer surface modifying endgroups: Resistance to biologic oxidation and stress cracking
    • Ward B, Anderson J, McVenes R, Stokes K. In vivo biostability of polyether polyurethanes with fluoropolymer surface modifying endgroups: resistance to biologic oxidation and stress cracking. J Biomed Mater Res 2006;79A:827-35.
    • (2006) J Biomed Mater Res , vol.79 A , pp. 827-835
    • Ward, B.1    Anderson, J.2    McVenes, R.3    Stokes, K.4
  • 43
    • 0042065563 scopus 로고
    • Ceel/ polymer interactions in the biodegradation of polyurethanes
    • Vert M, Feijen J, Albertsson A, Scott G, Chiellini E, eds. England: Royal Society of Chemistry;
    • Anderson JM, Hiltner A, Zhao QH, Wu Y, Renier M, Schubert M et al. Ceel/ polymer interactions in the biodegradation of polyurethanes. In: Vert M, Feijen J, Albertsson A, Scott G, Chiellini E, eds. Biodegradable Polymers and Plastics. England: Royal Society of Chemistry; 1992:122-36.
    • (1992) Biodegradable Polymers and Plastics , pp. 122-136
    • Anderson, J.M.1    Hiltner, A.2    Zhao, Q.H.3    Wu, Y.4    Renier, M.5    Schubert, M.6
  • 45
    • 0024097426 scopus 로고
    • Biomedical applications of polyurethanes: Implications of failure mechanisms
    • Phillips RE, Smith MC, Thoma RJ. Biomedical applications of polyurethanes: implications of failure mechanisms. J Biomater Appl 1988;3:207-27.
    • (1988) J Biomater Appl , vol.3 , pp. 207-227
    • Phillips, R.E.1    Smith, M.C.2    Thoma, R.J.3
  • 46
    • 0024102233 scopus 로고
    • Polyether polyurethane: Biostable or not?
    • Stokes KS. Polyether polyurethane: biostable or not? J Biomater Appl 1988;3: 229-58.
    • (1988) J Biomater Appl , vol.3 , pp. 229-258
    • Stokes, K.S.1
  • 47
    • 0020456136 scopus 로고
    • Polyether polyurethanes for implantable pacemaker leads
    • Stokes K, Bocian K. Polyether polyurethanes for implantable pacemaker leads. Biomaterials 1982;3:225-31.
    • (1982) Biomaterials , vol.3 , pp. 225-231
    • Stokes, K.1    Bocian, K.2
  • 49
    • 77951166174 scopus 로고    scopus 로고
    • Przetarcie silikonowych izolacji elektrod wewna?trzsercowych. Nowo odkryte zjawisko w elektroterapii: obserwacje w?asne
    • Kutarski A, Ma?ecka B. Przetarcie silikonowych izolacji elektrod wewna?trzsercowych. Nowo odkryte zjawisko w elektroterapii: obserwacje w?asne. Folia Cardiol Excerpta 2009;4:126-31.
    • (2009) Folia Cardiol Excerpta , vol.4 , pp. 126-131
    • Kutarski, A.1    Maecka, B.2
  • 50
    • 85060963926 scopus 로고    scopus 로고
    • Chester MK. St Jude Medical. Important Producent Information. St Jude Medical Riata and Riata ST silicone leads. December 2010.
    • Chester MK. St Jude Medical. Important Producent Information. St Jude Medical Riata and Riata ST silicone leads. December 2010.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.