Volumn 33, Issue 4, 2012, Pages 489-496

Effects of pulse width, pulse rate and paired electrode stimulation on psychophysical measures of dynamic range and speech recognition in cochlear implants

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; AUDITORY STIMULATION; COCHLEA PROSTHESIS; HEARING IMPAIRMENT; HUMAN; IMPLANTATION; METHODOLOGY; MIDDLE AGED; SPEECH AUDIOMETRY; SPEECH PERCEPTION;

EID: 84862883949     PISSN: 01960202     EISSN: None     Source Type: Journal    
DOI: 10.1097/AUD.0b013e31824c761a     Document Type: Article
Times cited : (24)

References (27)
  • 1
    • 2942737450 scopus 로고    scopus 로고
    • Speech recognition with a cochlear implant using triphasic charge-balanced pulses
    • Bonnet, R. M., Frijns, J. H., Peeters, S., et al. (2004). Speech recognition with a cochlear implant using triphasic charge-balanced pulses. Acta Otolaryngol, 124, 371-375.
    • (2004) Acta Otolaryngol , vol.124 , pp. 371-375
    • Bonnet, R.M.1    Frijns, J.H.2    Peeters, S.3
  • 3
    • 24944514839 scopus 로고    scopus 로고
    • Comparison of a paired or sequential stimulation paradigm with advanced bionics' high-resolution mode
    • Buechner, A., Frohne-Buechner, C., Stoever, T., et al. (2005). Comparison of a paired or sequential stimulation paradigm with advanced bionics' high-resolution mode. Otol Neurotol, 26, 941-947.
    • (2005) Otol Neurotol , vol.26 , pp. 941-947
    • Buechner, A.1    Frohne-Buechner, C.2    Stoever, T.3
  • 4
    • 33747081387 scopus 로고    scopus 로고
    • Current-level discrimination in the context of interleaved, multichannel stimulation in cochlear implants: Effects of number of stimulated electrodes, pulse rate, and electrode separation
    • Drennan, W. R., & Pfingst, B. E. (2006). Current-level discrimination in the context of interleaved, multichannel stimulation in cochlear implants: effects of number of stimulated electrodes, pulse rate, and electrode separation. J Assoc Res Otolaryngol, 7, 308-316.
    • (2006) J Assoc Res Otolaryngol , vol.7 , pp. 308-316
    • Drennan, W.R.1    Pfingst, B.2
  • 5
    • 18644380083 scopus 로고    scopus 로고
    • Effects of stimulation rate on speech recognition with cochlear implants
    • Friesen, L. M., Shannon, R. V., Cruz, R. J. (2005). Effects of stimulation rate on speech recognition with cochlear implants. Audiol Neurootol, 10, 169-184.
    • (2005) Audiol Neurootol , vol.10 , pp. 169-184
    • Friesen, L.M.1    Shannon, R.V.2    Cruz, R.J.3
  • 6
    • 0037242753 scopus 로고    scopus 로고
    • Optimizing the number of electrodes with high-rate stimulation of the clarion cii cochlear implant
    • Frijns, J. H., Klop, W. M., Bonnet, R. M., et al. (2003). Optimizing the number of electrodes with high-rate stimulation of the clarion CII cochlear implant. Acta Otolaryngol, 123, 138-142.
    • (2003) Acta Otolaryngol , vol.123 , pp. 138-142
    • Frijns, J.H.1    Klop, W.M.2    Bonnet, R.M.3
  • 7
    • 0036282173 scopus 로고    scopus 로고
    • Initial evaluation of the clarion cii cochlear implant: Speech perception and neural response imaging
    • Frijns, J. H., Briaire, J. J., de Laat, J. A., et al. (2002). Initial evaluation of the Clarion CII cochlear implant: speech perception and neural response imaging. Ear Hear, 23, 184-197.
    • (2002) Ear Hear , vol.23 , pp. 184-197
    • Frijns, J.H.1    Briaire, J.J.2    De Laat, J.A.3
  • 8
    • 0035025489 scopus 로고    scopus 로고
    • The importance of human cochlear anatomy for the results of modiolus-hugging multichannel cochlear implants
    • Frijns, J. H., Briaire, J. J., Grote, J. J. (2001). The importance of human cochlear anatomy for the results of modiolus-hugging multichannel cochlear implants. Otol Neurotol, 22, 340-349.
    • (2001) Otol Neurotol , vol.22 , pp. 340-349
    • Frijns, J.H.1    Briaire, J.J.2    Grote, J.J.3
  • 9
    • 33644854731 scopus 로고    scopus 로고
    • Effects of stimulation rate, mode and level on modulation detection by cochlear implant users
    • Galvin, J. J. 3rd, & Fu, Q. J. (2005). Effects of stimulation rate, mode and level on modulation detection by cochlear implant users. J Assoc Res Otolaryngol, 6, 269-279.
    • (2005) J Assoc Res Otolaryngol , vol.6 , pp. 269-279
    • Galvin III, J.J.1    Fu, Q.2
  • 10
    • 0036775950 scopus 로고    scopus 로고
    • Effects of stimulation rate with the nucleus 24 ace speech coding strategy
    • Holden, L. K., Skinner, M. W., Holden, T. A., et al. (2002). Effects of stimulation rate with the Nucleus 24 ACE speech coding strategy. Ear Hear, 23, 463-476.
    • (2002) Ear Hear , vol.23 , pp. 463-476
    • Holden, L.K.1    Skinner, M.W.2    Holden, T.A.3
  • 11
    • 2142755946 scopus 로고    scopus 로고
    • Effects of pulse rate on threshold and dynamic range in clarion cochlear-implant users
    • Kreft, H. A., Donaldson, G. S., Nelson, D. A. (2004). Effects of pulse rate on threshold and dynamic range in Clarion cochlear-implant users. J Acoust Soc Am, 115(5 Pt 1), 1885-1888.
    • (2004) J Acoust Soc Am , vol.115 , Issue.5 PART 1 , pp. 1885-1888
    • Kreft, H.A.1    Donaldson, G..S.2    Nelson, D.A.3
  • 12
    • 0038201552 scopus 로고    scopus 로고
    • Comparison of speech processing strategies used in the clarion implant processor
    • Loizou, P. C., Stickney, G., Mishra, L., et al. (2003). Comparison of speech processing strategies used in the Clarion implant processor. Ear Hear, 24, 12-19.
    • (2003) Ear Hear , vol.24 , pp. 12-19
    • Loizou, P.C.1    Stickney, G.2    Mishra, L.3
  • 13
    • 33747048422 scopus 로고    scopus 로고
    • Asymmetric pulses in cochlear implants: Effects of pulse shape, polarity, and rate
    • Macherey, O., van Wieringen, A., Carlyon, R. P., et al. (2006). Asymmetric pulses in cochlear implants: effects of pulse shape, polarity, and rate. J Assoc Res Otolaryngol, 7, 253-266.
    • (2006) J Assoc Res Otolaryngol , vol.7 , pp. 253-266
    • Macherey, O.1    Van Wieringen, A.2    Carlyon, R.P.3
  • 14
    • 0032813711 scopus 로고    scopus 로고
    • The perceptual effects of current pulse duration in electrical stimulation of the auditory nerve
    • McKay, C. M., & McDermott, H. J. (1999). The perceptual effects of current pulse duration in electrical stimulation of the auditory nerve. J Acoust Soc Am, 106, 998-1009.
    • (1999) J Acoust Soc Am , vol.106 , pp. 998-1009
    • McKay, C.M.1    McDermott, H.2
  • 15
    • 3142724861 scopus 로고    scopus 로고
    • Effects of cochlear-implant pulse rate and inter-channel timing on channel interactions and thresholds
    • Middlebrooks, J. C. (2004). Effects of cochlear-implant pulse rate and inter-channel timing on channel interactions and thresholds. J Acoust Soc Am, 116, 452-468.
    • (2004) J Acoust Soc Am , vol.116 , pp. 452-468
    • Middlebrooks, J.C.1
  • 16
    • 0027237399 scopus 로고
    • Effects of phase duration on detection of electrical stimulation of the human cochlea
    • Moon, A. K., Zwolan, T. A., Pfingst, B. E. (1993). Effects of phase duration on detection of electrical stimulation of the human cochlea. Hear Res, 67, 166-178.
    • (1993) Hear Res , vol.67 , pp. 166-178
    • Moon, A.K.1    Zwolan, T.A.2    Pfingst, B.E.3
  • 17
    • 0032951715 scopus 로고    scopus 로고
    • Pseudospontaneous activity: Stochastic independence of auditory nerve fibers with electrical stimulation
    • Rubinstein, J. T., Wilson, B. S., Finley, C. C., et al. (1999). Pseudospontaneous activity: stochastic independence of auditory nerve fibers with electrical stimulation. Hear Res, 127, 108-118.
    • (1999) Hear Res , vol.127 , pp. 108-118
    • Rubinstein, J.T.1    Wilson, B..S.2    Finley, C.C.3
  • 18
    • 0021790247 scopus 로고
    • Threshold and loudness functions for pulsatile stimulation of cochlear implants
    • Shannon, R. V. (1985). Threshold and loudness functions for pulsatile stimulation of cochlear implants. Hear Res, 18, 135-143.
    • (1985) Hear Res , vol.18 , pp. 135-143
    • Shannon, R.V.1
  • 19
    • 0024324673 scopus 로고
    • A model of threshold for pulsatile electrical stimulation of cochlear implants
    • Shannon, R. V. (1989). A model of threshold for pulsatile electrical stimulation of cochlear implants. Hear Res, 40, 197-204.
    • (1989) Hear Res , vol.40 , pp. 197-204
    • Shannon, R.V.1
  • 20
    • 0034036606 scopus 로고    scopus 로고
    • Effect of stimulation rate on cochlear implant recipients' thresholds and maximum acceptable loudness levels
    • Skinner, M. W., Holden, L. K., Holden, T. A., et al. (2000). Effect of stimulation rate on cochlear implant recipients' thresholds and maximum acceptable loudness levels. J Am Acad Audiol, 11, 203-213.
    • (2000) J Am Acad Audiol , vol.11 , pp. 203-213
    • Skinner, M.W.1    Holden, L.K.2    Holden, T.A.3
  • 21
    • 0026766605 scopus 로고
    • Speech reception in quiet and in noisy conditions by individuals with noise-induced hearing loss in relation to their tone audiogram
    • Smoorenburg, G. F. (1992). Speech reception in quiet and in noisy conditions by individuals with noise-induced hearing loss in relation to their tone audiogram. J Acoust Soc Am, 91, 421-437.
    • (1992) J Acoust Soc Am , vol.91 , pp. 421-437
    • Smoorenburg, G.F.1
  • 22
    • 3543099841 scopus 로고    scopus 로고
    • Criteria of candidacy for unilateral cochlear implantation in postlingually deafened adults i: Theory and measures of effectiveness
    • UK Cochlear Implant Study Group
    • UK Cochlear Implant Study Group. (2004). Criteria of candidacy for unilateral cochlear implantation in postlingually deafened adults I: theory and measures of effectiveness. Ear Hear, 25, 310-335.
    • (2004) Ear Hear , vol.25 , pp. 310-335
  • 23
    • 0033636134 scopus 로고    scopus 로고
    • Speech perception as a function of electrical stimulation rate: Using the nucleus 24 cochlear implant system
    • Vandali, A. E., Whitford, L. A., Plant, K. L., et al. (2000). Speech perception as a function of electrical stimulation rate: using the Nucleus 24 cochlear implant system. Ear Hear, 21, 608-624.
    • (2000) Ear Hear , vol.21 , pp. 608-624
    • Vandali, A.E.1    Whitford, L.A.2    Plant, K.L.3
  • 24
    • 33748592553 scopus 로고    scopus 로고
    • Clinical evaluation of the clarion cii hifocus 1 with and without positioner
    • van der Beek, F. B., Boermans, P. P., Verbist, B. M., et al. (2005). Clinical evaluation of the Clarion CII HiFocus 1 with and without positioner. Ear Hear, 26, 577-592.
    • (2005) Ear Hear , vol.26 , pp. 577-592
    • Van Der Beek, F.B.1    Boermans, P.P.2    Verbist, B.M.3
  • 25
    • 0026190743 scopus 로고
    • Better speech recognition with cochlear implants
    • Wilson, B. S., Finley, C. C., Lawson, D. T., et al. (1991). Better speech recognition with cochlear implants. Nature, 352, 236-238.
    • (1991) Nature , vol.352 , pp. 236-238
    • Wilson, B..S.1    Finley, C.C.2    Lawson, D.T.3
  • 26
    • 0029160281 scopus 로고
    • New processing strategies in cochlear implantation
    • Wilson, B. S., Lawson, D. T., Zerbi, M., et al. (1995). New processing strategies in cochlear implantation. Am J Otol, 16, 669-675.
    • (1995) Am J Otol , vol.16 , pp. 669-675
    • Wilson, B..S.1    Lawson, D.T.2    Zerbi, M.3
  • 27
    • 0032102115 scopus 로고    scopus 로고
    • Encoding loudness by electric stimulation of the auditory nerve
    • Zeng, F. G., Galvin, J. J. 3rd, Zhang, C. (1998). Encoding loudness by electric stimulation of the auditory nerve. Neuroreport, 9, 1845-1848.
    • (1998) Neuroreport , vol.9 , pp. 1845-1848
    • Zeng, F.G.1    Galvin III, J.J.2    Zhang, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.