메뉴 건너뛰기




Volumn 26, Issue 5, 2005, Pages 941-947

Comparison of a paired or sequential stimulation paradigm with advanced bionics' high-resolution mode

Author keywords

Cochlear implants; High stimulation rate; Simultaneous stimulation; Speech coding

Indexed keywords

ADULT; AGED; ARTICLE; AUDITORY STIMULATION; AUDITORY THRESHOLD; BIONICS; CLARION SPEECH CODING; CLINICAL ARTICLE; CLINICAL TRIAL; COCHLEA PROSTHESIS; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; CROSSOVER PROCEDURE; EVALUATION; FEMALE; HUMAN; IMPLANTATION; INTERMETHOD COMPARISON; MALE; MULTICHANNEL RECORDER; NOISE; PAIRED STIMULATION PARADIGM; PRIORITY JOURNAL; PROSPECTIVE STUDY; QUESTIONNAIRE; SEQUENTIAL STIMULATION PARADIGM; SPEECH ANALYSIS; TASK PERFORMANCE;

EID: 24944514839     PISSN: 15317129     EISSN: 15374505     Source Type: Journal    
DOI: 10.1097/01.mao.0000185069.27705.f0     Document Type: Article
Times cited : (15)

References (23)
  • 1
    • 0033768531 scopus 로고    scopus 로고
    • Optimized speech understanding with the continuous interleaved sampling speech coding strategy in patients with cochlear implants: Effect of variations in stimulation rate and number of channels
    • Kiefer JV, Ilberg Hubner-Egner C, Rupprecht V, Knecht R. Optimized speech understanding with the continuous interleaved sampling speech coding strategy in patients with cochlear implants: Effect of variations in stimulation rate and number of channels. Ann Otol Rhinol Laryngol 2000;109:1009-20.
    • (2000) Ann Otol Rhinol Laryngol , vol.109 , pp. 1009-1020
    • Kiefer, J.V.1    Ilberg Hubner-Egner, C.2    Rupprecht, V.3    Knecht, R.4
  • 2
    • 0033901505 scopus 로고    scopus 로고
    • The effect of parametric variations of cochlear implant processors on speech understanding
    • Loizou P, Poroy O, Dorman M. The effect of parametric variations of cochlear implant processors on speech understanding. J Acoust Soc Am 2000;108:790-802.
    • (2000) J Acoust Soc Am , vol.108 , pp. 790-802
    • Loizou, P.1    Poroy, O.2    Dorman, M.3
  • 4
    • 0032964608 scopus 로고    scopus 로고
    • Simultaneous analog stimulation (SAS)-continuous interleaved sampler (CIS) pilot comparison study in Europe
    • Battmer RD, Zilberman Y, Haake H, et al. Simultaneous analog stimulation (SAS)-continuous interleaved sampler (CIS) pilot comparison study in Europe. Ann Otol Rhinol Laryngol Suppl 1999;177:69-73.
    • (1999) Ann Otol Rhinol Laryngol Suppl , vol.177 , pp. 69-73
    • Battmer, R.D.1    Zilberman, Y.2    Haake, H.3
  • 5
    • 1442339896 scopus 로고    scopus 로고
    • Channel interaction and speech processing strategies for cochlear implants
    • Stickney G, Loizou P, Mishra L, et al. Channel interaction and speech processing strategies for cochlear implants. J Acoust Soc Am 2000;108(5, Pt. 2):2601.
    • (2000) J Acoust Soc Am , vol.108 , Issue.5 PART 2 , pp. 2601
    • Stickney, G.1    Loizou, P.2    Mishra, L.3
  • 6
    • 0032914992 scopus 로고    scopus 로고
    • Programming features of the Clarion Multi-Strategy Cochlear Implant
    • Zimmerman-Phillips S, Murad, C. Programming features of the Clarion Multi-Strategy Cochlear Implant. Ann Otol Rhinol Laryngol Suppl 1999;108:17-21.
    • (1999) Ann Otol Rhinol Laryngol Suppl , vol.108 , pp. 17-21
    • Zimmerman-Phillips, S.1    Murad, C.2
  • 8
    • 24944582415 scopus 로고    scopus 로고
    • Early results on high resolution (HiRes) programming with the Soundwave fitting software. Presented as a poster, Warsaw, Poland, May 22-24
    • Arnold A, Boyle P. Early results on high resolution (HiRes) programming with the Soundwave fitting software. Presented as a poster at the 7th International Conference on Cochlear Implants and Related Audiological Sciences, Warsaw, Poland, May 22-24, 2003.
    • (2003) 7th International Conference on Cochlear Implants and Related Audiological Sciences
    • Arnold, A.1    Boyle, P.2
  • 11
    • 17444440961 scopus 로고    scopus 로고
    • The HSM Sentence Test as a tool for evaluating the speech understanding in noise of cochlear implant users
    • Hochmair-Desoyer I, Schulz E, Moser L, Schmidt M. The HSM Sentence Test as a tool for evaluating the speech understanding in noise of cochlear implant users. Am J Otol 1998;18:83.
    • (1998) Am J Otol , vol.18 , pp. 83
    • Hochmair-Desoyer, I.1    Schulz, E.2    Moser, L.3    Schmidt, M.4
  • 12
    • 0034902190 scopus 로고    scopus 로고
    • Speech recognition in noise as a function of number of spectral channels: Comparison of acoustic hearing with cochlear implants
    • Friesen LM, Shannon RV, Baskent D, Wang X. Speech recognition in noise as a function of number of spectral channels: Comparison of acoustic hearing with cochlear implants. J Acoust Soc Am 2001;110:1150-63.
    • (2001) J Acoust Soc Am , vol.110 , pp. 1150-1163
    • Friesen, L.M.1    Shannon, R.V.2    Baskent, D.3    Wang, X.4
  • 13
    • 24944446290 scopus 로고    scopus 로고
    • A comparison of performance among patients fit with the CII Hi-Resolution, 3G and TEMPO+ processors. Presented as a poster, Asilomar, California
    • Spahr A, Dorman MF, Kirk KI. A comparison of performance among patients fit with the CII Hi-Resolution, 3G and TEMPO+ processors. Presented as a poster at the Conference on Implantable Auditory Protheses, Asilomar, California, 2003.
    • (2003) Conference on Implantable Auditory Protheses
    • Spahr, A.1    Dorman, M.F.2    Kirk, K.I.3
  • 14
    • 0142069398 scopus 로고    scopus 로고
    • Signal coding in cochlear implants: Exploiting stochastic effects of electrical stimulation
    • Rubinstein JT, Hong R. Signal coding in cochlear implants: Exploiting stochastic effects of electrical stimulation. Ann Otol Rhinol Laryngol Suppl 2003;191:14-19.
    • (2003) Ann Otol Rhinol Laryngol Suppl , vol.191 , pp. 14-19
    • Rubinstein, J.T.1    Hong, R.2
  • 15
    • 0038660474 scopus 로고    scopus 로고
    • The relative importance of amplitude, temporal, and spectral cues for cochlear implant processor design
    • Shannon RV. The relative importance of amplitude, temporal, and spectral cues for cochlear implant processor design. Am J Audiol 2002;11:124-7.
    • (2002) Am J Audiol , vol.11 , pp. 124-127
    • Shannon, R.V.1
  • 17
    • 0029821151 scopus 로고    scopus 로고
    • Enhancement of vowel coding for cochlear implants by addition of noise
    • Morse RP, Evans EF. Enhancement of vowel coding for cochlear implants by addition of noise. Nat Med 1996;2:928-32.
    • (1996) Nat Med , vol.2 , pp. 928-932
    • Morse, R.P.1    Evans, E.F.2
  • 18
    • 0037034899 scopus 로고    scopus 로고
    • Chimaeric sounds reveal dichotomies in auditory perception
    • Smith ZM, Delgutte B, Oxenham AJ. Chimaeric sounds reveal dichotomies in auditory perception. Nature 2002;416:87-90.
    • (2002) Nature , vol.416 , pp. 87-90
    • Smith, Z.M.1    Delgutte, B.2    Oxenham, A.J.3
  • 19
    • 0032427791 scopus 로고    scopus 로고
    • The recognition of sentences in noise by normal-hearing listeners using simulations of cochlear implant signal processors with 6-20 channels
    • Dorman MF, Loizou PF, Fitzke J, Tu Z. The recognition of sentences in noise by normal-hearing listeners using simulations of cochlear implant signal processors with 6-20 channels. J Acoust Soc Am 1998;104:3583-5.
    • (1998) J Acoust Soc Am , vol.104 , pp. 3583-3585
    • Dorman, M.F.1    Loizou, P.F.2    Fitzke, J.3    Tu, Z.4
  • 20
    • 0023526304 scopus 로고
    • Current distribution produced inside and outside the cochlea from a scala tympani electrode array
    • Ifukube T, White RL. Current distribution produced inside and outside the cochlea from a scala tympani electrode array. IEEE BME 1987;34:883-90.
    • (1987) IEEE BME , vol.34 , pp. 883-890
    • Ifukube, T.1    White, R.L.2
  • 21
    • 0142070765 scopus 로고    scopus 로고
    • Electrical field interactions in different cochlear implant systems
    • Boex C, de Balthasar C, Kos MI, Pelizzone M. Electrical field interactions in different cochlear implant systems. J Acoust Soc Am 2003;114(4, Pt. 1):2049-57.
    • (2003) J Acoust Soc Am , vol.114 , Issue.4 PART 1 , pp. 2049-2057
    • Boex, C.1    De Balthasar, C.2    Kos, M.I.3    Pelizzone, M.4
  • 22
    • 0037381050 scopus 로고    scopus 로고
    • Modulation masking in cochlear implant listeners: Envelope vs tonotopic component
    • Chatterjee M. Modulation masking in cochlear implant listeners: Envelope vs tonotopic component. J Acoust Soc Am 2003;113 (4, Pt. 1):20042-53.
    • (2003) J Acoust Soc Am , vol.113 , Issue.4 PART 1 , pp. 20042-20053
    • Chatterjee, M.1
  • 23
    • 0142121652 scopus 로고    scopus 로고
    • Forward masking in different cochlear implant systems
    • Boex C, Kos MI, Pelizzone M. Forward masking in different cochlear implant systems. J Acoust Soc Am 2003;114(4, Pt 1):2058-65.
    • (2003) J Acoust Soc Am , vol.114 , Issue.4 PART 1 , pp. 2058-2065
    • Boex, C.1    Kos, M.I.2    Pelizzone, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.