-
3
-
-
79953242567
-
Welcome to bioanalysis
-
Booth BP. Welcome to bioanalysis. Bioanalysis 1(1), 1-2 (2009).
-
(2009)
Bioanalysis.
, vol.1
, Issue.1
, pp. 1-2
-
-
Booth, B.P.1
-
5
-
-
6344277829
-
Biomarkers and surrogate endpoints: Clinical research and applications
-
Downing G. Biomarkers and surrogate endpoints: clinical research and applications. Clin. Pharmacol. Ther. 69(3), 89-95 (2001).
-
(2001)
Clin. Pharmacol. Ther.
, vol.69
, Issue.3
, pp. 89-95
-
-
Downing, G.1
-
6
-
-
70349664473
-
How to guide on biomarkers: Biomarker definitions, validation and applications with examples from cardiovascular disease
-
Puntmann VO. How to guide on biomarkers: biomarker definitions, validation and applications with examples from cardiovascular disease. Postgrad. Med. J. 85, 538-545 (2009).
-
(2009)
Postgrad. Med. J.
, vol.85
, pp. 538-545
-
-
Puntmann, V.O.1
-
7
-
-
33745753110
-
The role of mass spectrometry in biomarker discovery and measurement
-
Ackermann BL, Hale JE, Duffin KL. The role of mass spectrometry in biomarker discovery and measurement. Curr. Drug Metabol. 7(5), 525-539 (2006).
-
(2006)
Curr. Drug Metabol.
, vol.7
, Issue.5
, pp. 525-539
-
-
Ackermann, B.L.1
Hale, J.E.2
Duffin, K.L.3
-
8
-
-
34248545254
-
Mass spectrometry-based omics technologies in cancer diagnostics
-
DOI 10.1002/mas.20132
-
Zhang X, Wei D, Yap Y, Li L, Guo S, Chen F. Mass spectrometry-based 'omics' technologies in cancer diagnostics. Mass Spectrom. Rev. 26, 403-431 (2007). (Pubitemid 46750377)
-
(2007)
Mass Spectrometry Reviews
, vol.26
, Issue.3
, pp. 403-431
-
-
Zhang, X.1
Wei, D.2
Yap, Y.3
Li, L.4
Guo, S.5
Chen, F.6
-
9
-
-
30944466622
-
Mass spectrometry-based methods for biomarker detection and analysis
-
DOI 10.1016/j.ddtec.2005.11.011, PII S1740674905000740
-
Von Neuhoff N, Pich A. Mass spectrometry-based methods for biomarker detection and analysis. Drug Discov. Today Technol. 2(4), 361-367 (2005). (Pubitemid 43115473)
-
(2005)
Drug Discovery Today: Technologies
, vol.2
, Issue.4
, pp. 361-367
-
-
Von Neuhoff, N.1
Pich, A.2
Milos, P.M.3
-
10
-
-
0032529924
-
Nanoflow solvent gradient delivery from a microfabricated device for protein identifications by electrospray ionization mass spectrometry
-
Figeys D, Aebersold R. Nanoflow solvent gradient delivery from a microfabricated device for protein identifications by electrospray ionization mass spectrometry. Anal. Chem. 70(18), 3721-3727 (1998).
-
(1998)
Anal. Chem.
, vol.70
, Issue.18
, pp. 3721-3727
-
-
Figeys, D.1
Aebersold, R.2
-
11
-
-
0032530015
-
An integrated microfluidics-tandem mass spectrometry system for automated protein analysis
-
Figeys D, Gygi SP, Mckinnon G, Aebersold R. An integrated microfluidics-tandem mass spectrometry system for automated protein analysis. Anal. Chem. 70(18), 3728-3734 (1998).
-
(1998)
Anal. Chem.
, vol.70
, Issue.18
, pp. 3728-3734
-
-
Figeys, D.1
Gygi, S.P.2
McKinnon, G.3
Aebersold, R.4
-
12
-
-
0033128171
-
LC-MS applications in drug development
-
Lee MS, Kerns EH. LC-MS applications in drug development. Mass Spectrom. Rev. 18(3-4), 187-279 (1999).
-
(1999)
Mass Spectrom. Rev.
, vol.18
, Issue.3-4
, pp. 187-279
-
-
Lee, M.S.1
Kerns, E.H.2
-
13
-
-
43449083749
-
A decade of HPLC-MS/MS in the routine clinical laboratory - Goals for further developments
-
Vogeser M, Seger C. A decade of HPLC-MS/MS in the routine clinical laboratory - goals for further developments. Clin. Biochem. 41(9), 649-662 (2008).
-
(2008)
Clin. Biochem.
, vol.41
, Issue.9
, pp. 649-662
-
-
Vogeser, M.1
Seger, C.2
-
14
-
-
27144529964
-
Foundation review: Principles and applications of LC-MS in new drug discovery
-
Walter AK. Foundation review: principles and applications of LC-MS in new drug discovery. Drug Discov. Today 10(20), 1357-1367 (2005).
-
(2005)
Drug Discov. Today.
, vol.10
, Issue.20
, pp. 1357-1367
-
-
Walter, A.K.1
-
15
-
-
0032577428
-
Use of generic fast gradient liquid chromatography-tandem mass spectroscopy in quantitative bioanalysis
-
DOI 10.1016/S0378-4347(98)00074-7, PII S0378434798000747
-
Ayrton J, Dear GJ, Leavens WJ, Mallett DN, Plumb RS. Use of generic fast gradient liquid chromatography-tandem mass spectroscopy in quantitative bioanalysis. J. Chromatogr. B Biomed. Sci. Appl. 709(2), 243-254 (1998). (Pubitemid 28255357)
-
(1998)
Journal of Chromatography B: Biomedical Applications
, vol.709
, Issue.2
, pp. 243-254
-
-
Ayrton, J.1
Dear, G.J.2
Leavens, W.J.3
Mallett, D.N.4
Plumb, R.S.5
-
16
-
-
58249134490
-
Analysis of angiotensin II receptor antagonist and protein markers at microliter level plasma by LC-MS/MS
-
Lu CY, Chang YM, Tseng WL, Feng CH, Lu CY. Analysis of angiotensin II receptor antagonist and protein markers at microliter level plasma by LC-MS/MS. J. Pharm. Biomed. Anal. 49(1), 123-128 (2009).
-
(2009)
J. Pharm. Biomed. Anal.
, vol.49
, Issue.1
, pp. 123-128
-
-
Lu, C.Y.1
Chang, Y.M.2
Tseng, W.L.3
Feng, C.H.4
Lu, C.Y.5
-
17
-
-
8444223860
-
High-field asymmetric waveform ion mobility spectrometry: A new tool for mass spectrometry
-
DOI 10.1016/j.chroma.2004.08.119, PII S0021967304014785, Mass Spectrometry: Innovation and Application. Part III
-
Guevremont R. High-field asymmetric waveform ion mobility spectrometry: a new tool for mass spectrometry. J. Chromatogr. A 1058, 3-19 (2004). (Pubitemid 39487201)
-
(2004)
Journal of Chromatography A
, vol.1058
, Issue.1-2
, pp. 3-19
-
-
Guevremont, R.1
-
18
-
-
34548049977
-
Review of applications of high-field asymmetric waveform ion mobility spectrometry (FAIMS) and differential mobility spectrometry (DMS)
-
DOI 10.1039/b706039d
-
Kolakowski BM, Mester Z. Review of applications of high-field asymmetric waveform ion mobility spectrometry (FAIMS) and differential mobility spectrometry (DMS). Analyst 132, 842-864 (2007). (Pubitemid 47283703)
-
(2007)
Analyst
, vol.132
, Issue.9
, pp. 842-864
-
-
Kolakowski, B.M.1
Mester, Z.2
-
19
-
-
0032324858
-
Mass spectrometric characterization of high-field asymmetric waveform ion mobility spectrometer
-
Purves RW, Guevremont R. Mass spectrometric characterization of high-field asymmetric waveform ion mobility spectrometer. Rev. Sci. Instrum. 69(12), 4094-4105 (1998).
-
(1998)
Rev. Sci. Instrum.
, vol.69
, Issue.12
, pp. 4094-4105
-
-
Purves, R.W.1
Guevremont, R.2
-
20
-
-
0000741268
-
A new method of separation of multi-atomic ions by mobility at atmospheric pressure using a high-frequency amplitude-asymmetric strong electric field
-
Buryakov IA, Krylov EV, Nazarov EG, Rasulev UK. A new method of separation of multi-atomic ions by mobility at atmospheric pressure using a high-frequency amplitude-asymmetric strong electric field. Int. J. Mass Spectrom. Ion Proc. 128, 143-148 (1993).
-
(1993)
Int. J. Mass Spectrom. Ion Proc.
, vol.128
, pp. 143-148
-
-
Buryakov, I.A.1
Krylov, E.V.2
Nazarov, E.G.3
Rasulev, U.K.4
-
22
-
-
68049083696
-
Ultrafast differential ion mobility spectrometry at extreme electric fields in multichannel microchips
-
Shvartsburg AA, Smith RD, Wilks A, Koehl A, Ruiz-Alonso D, Boyle B. Ultrafast differential ion mobility spectrometry at extreme electric fields in multichannel microchips. Anal. Chem. 81, 6489-6495 (2009).
-
(2009)
Anal. Chem.
, vol.81
, pp. 6489-6495
-
-
Shvartsburg, A.A.1
Smith, R.D.2
Wilks, A.3
Koehl, A.4
Ruiz-Alonso, D.5
Boyle, B.6
-
23
-
-
33744949963
-
High-resolution field asymmetric waveform ion mobility spectrometry using new planar geometry analyzers
-
DOI 10.1021/ac052020v
-
Shvartsburg AA, Li F, Tang K, Smith RD. High-resolution field asymmetric waveform ion mobility spectrometry using new planar geometry analyzers. Anal. Chem. 78(11), 3706-3714 (2006). (Pubitemid 43853050)
-
(2006)
Analytical Chemistry
, vol.78
, Issue.11
, pp. 3706-3714
-
-
Shvartsburg, A.A.1
Li, F.2
Tang, K.3
Smith, R.D.4
-
24
-
-
0033613329
-
Ion trapping at atmospheric pressure (760 Torr) and room temperature with a high-field asymmetric waveform ion mobility spectrometer
-
Guevremont R, Purves RW, Barnett DA, Ding L. Ion trapping at atmospheric pressure (760 Torr) and room temperature with a high-field asymmetric waveform ion mobility spectrometer. Int. J. Mass Spectrom. 193, 45-56 (1999).
-
(1999)
Int. J. Mass Spectrom.
, vol.193
, pp. 45-56
-
-
Guevremont, R.1
Purves, R.W.2
Barnett, D.A.3
Ding, L.4
-
26
-
-
0034307599
-
Analysis of a tryptic digest of pig hemoglobin using ESI-FAIMS-MS
-
Guevremont R, Barnett DA, Purves RW, Vandermey J. Analysis of a tryptic digest of pig hemoglobin using ESI-FAIMS-MS. Anal. Chem. 72(19), 4577-4584 (2000).
-
(2000)
Anal. Chem.
, vol.72
, Issue.19
, pp. 4577-4584
-
-
Guevremont, R.1
Barnett, D.A.2
Purves, R.W.3
Vandermey, J.4
-
27
-
-
78349307965
-
Design and evaluation of a novel hemispherical FAIMS cell
-
Bryant JG, Prieto M, Prox TA, Yost RA. Design and evaluation of a novel hemispherical FAIMS cell. Int. J. Mass Spectrom. 298, 41-44 (2010).
-
(2010)
Int. J. Mass Spectrom.
, vol.298
, pp. 41-44
-
-
Bryant, J.G.1
Prieto, M.2
Prox, T.A.3
Yost, R.A.4
-
28
-
-
84860415972
-
Spherical FAIMS. Comparison of curved electrode geometries
-
Prieto M, Yost R. Spherical FAIMS. Comparison of curved electrode geometries. Int. J. Ion Mobil. Spectrom. 14(2), 61-69 (2011).
-
(2011)
Int. J. Ion Mobil. Spectrom
, vol.14
, Issue.2
, pp. 61-69
-
-
Prieto, M.1
Yost, R.2
-
29
-
-
0033249612
-
A method of reducing diffusion losses in a drift spectrometer
-
Krylov EV. A method of reducing diffusion losses in a drift spectrometer. Techn. Phys. 44(1), 113-116 (1999).
-
(1999)
Techn. Phys.
, vol.44
, Issue.1
, pp. 113-116
-
-
Krylov, E.V.1
-
30
-
-
0035564254
-
Atmospheric pressure ion trapping in a tandem FAIMS-FAIMS coupled to a TOFMS: Studies with electrospray generated gramicidin S ions
-
DOI 10.1016/S1044-0305(01)00321-X, PII S104403050100321X
-
Guevremont R, Ding L, Ells B, Barnett DA, Purves RW. Atmospheric pressure ion trapping in a tandem FAIMS/FAIMS coupled to a TOF MS: studies with electrospray generated gramicidin S ions. J. Am. Soc. Mass Spectrom. 12, 1320-1330 (2001). (Pubitemid 34552637)
-
(2001)
Journal of the American Society for Mass Spectrometry
, vol.12
, Issue.12
, pp. 1320-1330
-
-
Guevremont, R.1
Ding, L.2
Ells, B.3
Barnett, D.A.4
Purves, R.W.5
-
31
-
-
46749103222
-
Differential mobility separation of ions using a rectangular asymmetric waveform
-
Papanastasiou D, Wollnik H, Rico G, Tadjimukhamedov F, Mueller W, Eiceman GA. Differential mobility separation of ions using a rectangular asymmetric waveform. J. Phys. Chem. A 112(16), 3638-3645 (2008).
-
(2008)
J. Phys. Chem. A.
, vol.112
, Issue.16
, pp. 3638-3645
-
-
Papanastasiou, D.1
Wollnik, H.2
Rico, G.3
Tadjimukhamedov, F.4
Mueller, W.5
Eiceman, G.A.6
-
32
-
-
11844262051
-
Optimization of the design and operation of FAIMS analyzers
-
DOI 10.1016/j.jasms.2004.09.009, PII S1044030504006026
-
Shvartsburg AA, Tang K, Smith RD. Optimization of the design and operation of FAIMS analyzers. J. Am. Soc. Mass Spectrom. 16(1), 2-12 (2005). (Pubitemid 40093795)
-
(2005)
Journal of the American Society for Mass Spectrometry
, vol.16
, Issue.1
, pp. 2-12
-
-
Shvartsburg, A.A.1
Tang, K.2
Smith, R.D.3
-
33
-
-
67650224010
-
Electric field dependence of the ion mobility
-
Krylov EV, Nazarov EG. Electric field dependence of the ion mobility. Int. J. Mass Spectrom. 285(3), 149-156 (2009).
-
(2009)
Int. J. Mass Spectrom.
, vol.285
, Issue.3
, pp. 149-156
-
-
Krylov, E.V.1
Nazarov, E.G.2
-
34
-
-
34548385773
-
Differential mobility spectrometer: Model of operation
-
Krylov EV, Nazarov EG, Miller RA. Differential mobility spectrometer: model of operation. Int. J. Mass Spectrom. 266(1-3), 76-85 (2007).
-
(2007)
Int. J. Mass Spectrom.
, vol.266
, Issue.1-3
, pp. 76-85
-
-
Krylov, E.V.1
Nazarov, E.G.2
Miller, R.A.3
-
35
-
-
50849112386
-
Optimum waveforms for differential ion mobility spectrometry (FAIMS)
-
Shvartsburg AA, Smith RD. Optimum waveforms for differential ion mobility spectrometry (FAIMS). J. Am. Soc. Mass Spectrom. 19(9), 1286-1295 (2008).
-
(2008)
J. Am. Soc. Mass Spectrom.
, vol.19
, Issue.9
, pp. 1286-1295
-
-
Shvartsburg, A.A.1
Smith, R.D.2
-
36
-
-
33644899953
-
Feasibility of higher-order differential ion mobility separations using new asymmetric waveforms
-
Shvartsburg AA, Mashkevich SV, Smith RD. Feasibility of higher-order differential ion mobility separations using new asymmetric waveforms. J. Phys. Chem. A 110(8), 2663-2673 (2006).
-
(2006)
J. Phys. Chem. A.
, vol.110
, Issue.8
, pp. 2663-2673
-
-
Shvartsburg, A.A.1
Mashkevich, S.V.2
Smith, R.D.3
-
37
-
-
83655164817
-
Comparison of rectangular and bisinusoidal waveforms in a miniature planar high-field asymmetric waveform ion mobility spectrometer
-
Prieto M, Tsai CW, Boumsellek S et al. Comparison of rectangular and bisinusoidal waveforms in a miniature planar high-field asymmetric waveform ion mobility spectrometer. Anal. Chem. 83(24), 9237-9243 (2011).
-
(2011)
Anal. Chem.
, vol.83
, Issue.24
, pp. 9237-9243
-
-
Prieto, M.1
Tsai, C.W.2
Boumsellek, S.3
-
38
-
-
84862836925
-
-
Presented at: 57th ASMS Conference. PA, USA, 31 May-4 June
-
Tsai CW, Prieto M, Kaminsky I, Ferran R, Boudries H, Yost RA. Comparison of square and sinusoidal waveforms on a miniaturized planar FAIMS cell for explosives detection. Presented at: 57th ASMS Conference. PA, USA, 31 May-4 June 2009.
-
(2009)
Comparison of Square and Sinusoidal Waveforms on A Miniaturized Planar FAIMS Cell for Explosives Detection
-
-
Tsai, C.W.1
Prieto, M.2
Kaminsky, I.3
Ferran, R.4
Boudries, H.5
Yost, R.A.6
-
39
-
-
77949801007
-
High-resolution differential ion mobility separations using helium-rich gases
-
Shvartsburg AA, Danielson WF, Smith RD. High-resolution differential ion mobility separations using helium-rich gases. Anal. Chem. 82(6), 2456-2462 (2010).
-
(2010)
Anal. Chem.
, vol.82
, Issue.6
, pp. 2456-2462
-
-
Shvartsburg, A.A.1
Danielson, W.F.2
Smith, R.D.3
-
40
-
-
10644224548
-
Understanding and designing field asymmetric waveform ion mobility spectrometry separations in gas mixtures
-
DOI 10.1021/ac049299k
-
Shvartsburg AA, Tang K, Smith RD. Understanding and designing field asymmetric waveform ion mobility spectrometry separations in gas mixtures. Anal. Chem. 76(24), 7366-7374 (2004). (Pubitemid 39658009)
-
(2004)
Analytical Chemistry
, vol.76
, Issue.24
, pp. 7366-7374
-
-
Shvartsburg, A.A.1
Tang, K.2
Smith, R.D.3
-
41
-
-
75749092642
-
Differential ion mobility separations of peptides with resolving power exceeding 50
-
Shvartsburg AA, Tang K, Smith RD. Differential ion mobility separations of peptides with resolving power exceeding 50. Anal. Chem. 82(1), 32-35 (2009).
-
(2009)
Anal. Chem.
, vol.82
, Issue.1
, pp. 32-35
-
-
Shvartsburg, A.A.1
Tang, K.2
Smith, R.D.3
-
42
-
-
77957320584
-
Isotopic effect on ion mobility and separation of isotopomers by high-field ion mobility spectrometry
-
Shvartsburg AA, Clemmer DE, Smith RD. Isotopic effect on ion mobility and separation of isotopomers by high-field ion mobility spectrometry. Anal. Chem. 82(19), 8047-8051 (2010).
-
(2010)
Anal. Chem.
, vol.82
, Issue.19
, pp. 8047-8051
-
-
Shvartsburg, A.A.1
Clemmer, D.E.2
Smith, R.D.3
-
43
-
-
0000056838
-
Atmospheric pressure ion focusing in a high-field asymmetric waveform ion mobility spectrometer
-
Guevremont R, Purves RW. Atmospheric pressure ion focusing in a high-field asymmetric waveform ion mobility spectrometer. Rev. Sci. Instrum. 70(2), 1370-1383 (1999). (Pubitemid 129576199)
-
(1999)
Review of Scientific Instruments
, vol.70
, Issue.2
, pp. 1370-1383
-
-
Guevremont, R.1
Purves, R.W.2
-
44
-
-
4444309530
-
Separation of ions from explosives in differential mobility spectrometry by vapor-modified drift gas
-
DOI 10.1021/ac035502k
-
Eiceman GA, Krylov EV, Krylova NS, Nazarov EG, Miller RA. Separation of ions from explosives in differential mobility spectrometry by vapor-modified drift gas. Anal. Chem. 76(17), 4937-4944 (2004). (Pubitemid 39180317)
-
(2004)
Analytical Chemistry
, vol.76
, Issue.17
, pp. 4937-4944
-
-
Eiceman, G.A.1
Krylov, E.V.2
Krylova, N.S.3
Nazarov, E.G.4
Miller, R.A.5
-
45
-
-
33751088257
-
Compensation voltage shifting in high-field asymmetric waveform ion mobility spectrometry-mass spectrometry
-
DOI 10.1002/rcm.2739
-
Kolakowski BM, Mccooeye MA, Mester Z. Compensation voltage shifting in high-field asymmetric waveform ion mobility spectrometry-mass spectrometry. Rapid Commun. Mass Spectrom. 20(22), 3319-3329 (2006). (Pubitemid 44763928)
-
(2006)
Rapid Communications in Mass Spectrometry
, vol.20
, Issue.22
, pp. 3319-3329
-
-
Kolakowski, B.M.1
McCooeye, M.A.2
Mester, Z.3
-
46
-
-
0037672763
-
Effect of moisture on the field dependence of mobility for gas-phase ions of organophosphorus compounds at atmospheric pressure with field asymmetric ion mobility spectrometry
-
Krylova N, Krylov E, Eiceman GA, Stone JA. Effect of moisture on the field dependence of mobility for gas-phase ions of organophosphorus compounds at atmospheric pressure with field asymmetric ion mobility spectrometry. J. Phys. Chem. A 107(19), 3648-3654 (2003).
-
(2003)
J. Phys. Chem. A
, vol.107
, Issue.19
, pp. 3648-3654
-
-
Krylova, N.1
Krylov, E.2
Eiceman, G.A.3
Stone, J.A.4
-
47
-
-
30044434222
-
Characterization of gas-phase molecular interactions on differential mobility ion behavior utilizing an electrospray ionization-differential mobility-mass spectrometer system
-
DOI 10.1021/ac051217k
-
Levin DS, Vouros P, Miller RA, Nazarov EG, Morris JC. Characterization of gas-phase molecular interactions on differential mobility ion behavior utilizing an electrospray ionization-differential mobility mass spectrometer system. Anal. Chem. 78(1), 96-106 (2005). (Pubitemid 43050143)
-
(2006)
Analytical Chemistry
, vol.78
, Issue.1
, pp. 96-106
-
-
Levin, D.S.1
Vouros, P.2
Miller, R.A.3
Nazarov, E.G.4
Morris, J.C.5
-
48
-
-
77749302232
-
Chemical effects in the separation process of a differential mobility mass spectrometer system
-
Schneider BB, Covey TR, Coy SL, Krylov EV, Nazarov EG. Chemical effects in the separation process of a differential mobility mass spectrometer system. Anal. Chem. 82(5), 1867-1880 (2010).
-
(2010)
Anal. Chem.
, vol.82
, Issue.5
, pp. 1867-1880
-
-
Schneider, B.B.1
Covey, T.R.2
Coy, S.L.3
Krylov, E.V.4
Nazarov, E.G.5
-
49
-
-
77956583256
-
Solvent vapor effects on planar high-field asymmetric waveform ion mobility spectrometry
-
Rorrer LC 3rd, Yost RA. Solvent vapor effects on planar high-field asymmetric waveform ion mobility spectrometry. Int. J. Mass Spectrom. 300(2-3), 173-181 (2011).
-
(2011)
Int. J. Mass Spectrom.
, vol.300
, Issue.2-3
, pp. 173-181
-
-
Rorrer, L.C.1
Yost, R.A.2
-
50
-
-
0036831034
-
Application of ESI-FAIMS-MS to the analysis of tryptic peptides
-
DOI 10.1016/S1044-0305(02)00527-5, PII S1044030502005275
-
Barnett D, Ells B, Guevremont R, Purves R. Application of ESI-FAIMS-MS to the analysis of tryptic peptides. J. Am. Soc. Mass Spectrom. 13(11), 1282-1291 (2002). (Pubitemid 36875982)
-
(2002)
Journal of the American Society for Mass Spectrometry
, vol.13
, Issue.11
, pp. 1282-1291
-
-
Barnett, D.A.1
Ells, B.2
Guevremont, R.3
Purves, R.W.4
-
51
-
-
16244366808
-
Improvement in peptide detection for proteomics analyses using nanoLC-MS and high-field asymmetry waveform ion mobility mass spectrometry
-
DOI 10.1021/ac048410j
-
Venne K, Bonneil E, Eng K, Thibault P. Improvement in peptide detection for proteomics analyses using nanoLC-MS and high-field asymmetry waveform ion mobility mass spectrometry. Anal. Chem. 77(7), 2176-2186 (2005). (Pubitemid 40463835)
-
(2005)
Analytical Chemistry
, vol.77
, Issue.7
, pp. 2176-2186
-
-
Venne, K.1
Bonneil, E.2
Eng, K.3
Thibault, P.4
-
52
-
-
33746809833
-
Rapid separation and quantitative analysis of peptides using a new nanoelectrospray-differential mobility spectrometer-mass spectrometer system
-
DOI 10.1021/ac060003f
-
Levin DS, Miller RA, Nazarov EG, Vouros P. Rapid separation and quantitative analysis of peptides using a new nanoelectrospray-differential mobility spectrometer mass spectrometer system. Anal. Chem. 78(15), 5443-5452 (2006). (Pubitemid 44182363)
-
(2006)
Analytical Chemistry
, vol.78
, Issue.15
, pp. 5443-5452
-
-
Levin, D.S.1
Miller, R.A.2
Nazarov, E.G.3
Vouros, P.4
-
53
-
-
51949104348
-
LC-FAIMS-MS/ MS for quantification of a peptide in plasma and evaluation of FAIMS global selectivity from plasma components
-
Xia YQ, Wu ST, Jemal M. LC-FAIMS-MS/ MS for quantification of a peptide in plasma and evaluation of FAIMS global selectivity from plasma components. Anal. Chem. 80(18), 7137-7143 (2008).
-
(2008)
Anal. Chem.
, vol.80
, Issue.18
, pp. 7137-7143
-
-
Xia, Y.Q.1
Wu, S.T.2
Jemal, M.3
-
54
-
-
84856675258
-
Improvement of phosphoproteome analyses using FAIMS and decision tree fragmentation. Application to the insulin signaling pathway in Drosophila melanogaster S2 cells
-
Bridon G, Bonneil E, Muratore-Schroeder T, Caron-Lizotte O, Thibault P. Improvement of phosphoproteome analyses using FAIMS and decision tree fragmentation. Application to the insulin signaling pathway in Drosophila melanogaster S2 cells. J. Proteome Res. 11(2), 927-940 (2011).
-
(2011)
J. Proteome Res.
, vol.11
, Issue.2
, pp. 927-940
-
-
Bridon, G.1
Bonneil, E.2
Muratore-Schroeder, T.3
Caron-Lizotte, O.4
Thibault, P.5
-
55
-
-
79960026139
-
Separation and classification of lipids using differential ion mobility spectrometry
-
Shvartsburg A, Isaac G, Leveque N, Smith R, Metz T. Separation and classification of lipids using differential ion mobility spectrometry. J. Am. Soc. Mass Spectrom. 22(7), 1146-1155 (2011).
-
(2011)
J. Am. Soc. Mass Spectrom.
, vol.22
, Issue.7
, pp. 1146-1155
-
-
Shvartsburg, A.1
Isaac, G.2
Leveque, N.3
Smith, R.4
Metz, T.5
-
56
-
-
33847054648
-
Using a Nanoelectrospray-Differential Mobility Spectrometer-Mass Spectrometer System for the Analysis of Oligosaccharides with Solvent Selected Control Over ESI Aggregate Ion Formation
-
DOI 10.1016/j.jasms.2006.10.008, PII S1044030506009548
-
Levin D, Vouros P, Miller R, Nazarov E. Using a nanoelectrospray- differential mobility spectrometer mass spectrometer system for the analysis of oligosaccharides with solvent selected control over ESI aggregate ion formation. J. Am. Soc. Mass Spectrom. 18(3), 502-511 (2007). (Pubitemid 46274383)
-
(2007)
Journal of the American Society for Mass Spectrometry
, vol.18
, Issue.3
, pp. 502-511
-
-
Levin, D.S.1
Vouros, P.2
Miller, R.A.3
Nazarov, E.G.4
-
57
-
-
77957292542
-
Separation of peptide isomers with variant modified sites by high-resolution differential ion mobility spectrometry
-
Shvartsburg AA, Creese AJ, Smith RD, Cooper HJ. Separation of peptide isomers with variant modified sites by high-resolution differential ion mobility spectrometry. Anal. Chem. 82(19), 8327-8334 (2010).
-
(2010)
Anal. Chem.
, vol.82
, Issue.19
, pp. 8327-8334
-
-
Shvartsburg, A.A.1
Creese, A.J.2
Smith, R.D.3
Cooper, H.J.4
-
58
-
-
34547164394
-
Evaluation of high-field asymmetric waveform ion mobility spectrometry coupled to nanoelectrospray ionization for bioanalysis in drug discovery
-
DOI 10.1002/rcm.3093
-
Hatsis P, Brockman AH, Wu JT. Evaluation of high-field asymmetric waveform ion mobility spectrometry coupled to nanoelectrospray ionization for bioanalysis in drug discovery. Rapid Commun. Mass Spectrom. 21(14), 2295-2300 (2007). (Pubitemid 47121161)
-
(2007)
Rapid Communications in Mass Spectrometry
, vol.21
, Issue.14
, pp. 2295-2300
-
-
Hatsis, P.1
Brockman, A.H.2
Wu, J.-T.3
|