메뉴 건너뛰기




Volumn 25, Issue 5, 2012, Pages 542-548

Measurement of central systolic blood pressure by pulse volume plethysmography with a noninvasive blood pressure monitor

Author keywords

blood pressure; central blood pressure; hypertension; noninvasive method; oscillometry; pulse volume plethysmography

Indexed keywords

ADULT; AGED; AORTA; ARTICLE; BLOOD PRESSURE MEASUREMENT; BRACHIAL ARTERY; CALIBRATION; DIASTOLIC BLOOD PRESSURE; FEMALE; HEART CATHETERIZATION; HUMAN; MAJOR CLINICAL STUDY; MALE; MEAN ARTERIAL PRESSURE; MONITOR; NONINVASIVE BLOOD PRESSURE MONITOR; OSCILLOMETRY; PLETHYSMOGRAPHY; PRIORITY JOURNAL; PULSE PRESSURE; PULSE VOLUME PLETHYSMOGRAPHY; SYSTOLIC BLOOD PRESSURE; WAVEFORM;

EID: 84862832776     PISSN: 08957061     EISSN: 19417225     Source Type: Journal    
DOI: 10.1038/ajh.2011.259     Document Type: Article
Times cited : (16)

References (25)
  • 1
    • 84961014643 scopus 로고
    • Comparison of simultaneously recorded central and peripheral arterial pressure pulses during rest, exercise and tilted position in man
    • Kroeker EJ, Wood EH. Comparison of simultaneously recorded central and peripheral arterial pressure pulses during rest, exercise and tilted position in man. Circ Res 1955; 3:623-632.
    • (1955) Circ Res , vol.3 , pp. 623-632
    • Kroeker, E.J.1    Wood, E.H.2
  • 2
    • 0029148352 scopus 로고
    • Underestimation of vasodilator effects of nitroglycerin by upper limb blood pressure
    • Takazawa K, Tanaka N, Takeda K, Kurosu F, Ibukiyama C. Underestimation of vasodilator effects of nitroglycerin by upper limb blood pressure. Hypertension 1995; 26:520-523.
    • (1995) Hypertension , vol.26 , pp. 520-523
    • Takazawa, K.1    Tanaka, N.2    Takeda, K.3    Kurosu, F.4    Ibukiyama, C.5
  • 4
    • 0025218934 scopus 로고
    • Nitroglycerin has more favourable effects on left ventricular afterload than apparent from measurement of pressure in a peripheral artery
    • Kelly RP, Gibbs HH, O'Rourke MF, Daley JE, Mang K, Morgan JJ, Avolio AP. Nitroglycerin has more favourable effects on left ventricular afterload than apparent from measurement of pressure in a peripheral artery. Eur Heart J 1990; 11:138-144. (Pubitemid 20095698)
    • (1990) European Heart Journal , vol.11 , Issue.2 , pp. 138-144
    • Kelly, R.P.1    Gibbs, H.H.2    O'Rourke, M.F.3    Daley, J.E.4    Mang, K.5    Morgan, J.J.6    Avolio, A.P.7
  • 7
    • 34250875202 scopus 로고    scopus 로고
    • Central pressure more strongly relates to vascular disease and outcome than does brachial pressure: The strong heart study
    • DOI 10.1161/HYPERTENSIONAHA.107.089078
    • Roman MJ, Devereux RB, Kizer JR, Lee ET, Galloway JM, Ali T, Umans JG, Howard BV. Central pressure more strongly relates to vascular disease and outcome than does brachial pressure: the Strong Heart Study. Hypertension 2007; 50:197-203. (Pubitemid 46986041)
    • (2007) Hypertension , vol.50 , Issue.1 , pp. 197-203
    • Roman, M.J.1    Devereux, R.B.2    Kizer, J.R.3    Lee, E.T.4    Galloway, J.M.5    Ali, T.6    Umans, J.G.7    Howard, B.V.8
  • 10
    • 62249156959 scopus 로고    scopus 로고
    • Is there any additional prognostic value of central blood pressure wave forms beyond peripheral blood pressure?
    • Sabovic M, Safar ME, Blacher J. Is there any additional prognostic value of central blood pressure wave forms beyond peripheral blood pressure? Curr Pharm Des 2009; 15:254-266.
    • (2009) Curr Pharm des , vol.15 , pp. 254-266
    • Sabovic, M.1    Safar, M.E.2    Blacher, J.3
  • 12
    • 0027460281 scopus 로고
    • An analysis of the relationship between central aortic and peripheral upper limb pressure waves in man
    • Karamanoglu M, O'Rourke MF, Avolio AP, Kelly RP. An analysis of the relationship between central aortic and peripheral upper limb pressure waves in man. Eur Heart J 1993; 14:160-167. (Pubitemid 23089501)
    • (1993) European Heart Journal , vol.14 , Issue.2 , pp. 160-167
    • Karamanoglu, M.1    O'Rourke, M.F.2    Avolio, A.P.3    Kelly, R.P.4
  • 13
    • 0030970060 scopus 로고    scopus 로고
    • Estimation of Central aortic pressure waveform by mathematical transformation of radial tonometry pressure: Validation of generalized transfer function
    • Chen CH, Nevo E, Fetics B, Pak PH, Yin FC, Maughan WL, Kass DA. Estimation of central aortic pressure waveform by mathematical transformation of radial tonometry pressure. Validation of generalized transfer function. Circulation 1997; 95:1827-1836. (Pubitemid 27164400)
    • (1997) Circulation , vol.95 , Issue.7 , pp. 1827-1836
    • Chen, C.-H.1    Nevo, E.2    Fetics, B.3    Pak, P.H.4    Yin, F.C.P.5    Maughan, W.L.6    Kass, D.A.7
  • 14
    • 75149171005 scopus 로고    scopus 로고
    • Clinical use of applanation tonometry: Hope remains in Pandora's box
    • O'Rourke MF, Adji A. Clinical use of applanation tonometry: hope remains in Pandora's box. J Hypertens 2010; 28:229-233.
    • (2010) J Hypertens , vol.28 , pp. 229-233
    • O'Rourke, M.F.1    Adji, A.2
  • 16
    • 37249019474 scopus 로고    scopus 로고
    • Brachial-ankle vs carotid-femoral pulse wave velocity as a determinant of cardiovascular structure and function
    • Yu WC, Chuang SY, Lin YP, Chen CH. Brachial-ankle vs carotid-femoral pulse wave velocity as a determinant of cardiovascular structure and function. J Hum Hypertens 2008; 22:24-31.
    • (2008) J Hum Hypertens , vol.22 , pp. 24-31
    • Yu, W.C.1    Chuang, S.Y.2    Lin, Y.P.3    Chen, C.H.4
  • 17
    • 53549101912 scopus 로고    scopus 로고
    • Validation of the Microlife Watch BP Office professional device for office blood pressure measurement according to the International protocol
    • Stergiou GS, Tzamouranis D, Protogerou A, Nasothimiou E, Kapralos C. Validation of the Microlife Watch BP Office professional device for office blood pressure measurement according to the International protocol. Blood Press Monit 2008; 13:299-303.
    • (2008) Blood Press Monit , vol.13 , pp. 299-303
    • Stergiou, G.S.1    Tzamouranis, D.2    Protogerou, A.3    Nasothimiou, E.4    Kapralos, C.5
  • 18
    • 0035991085 scopus 로고    scopus 로고
    • A simple oscillometric technique for determining new indices of arterial distensibility
    • DOI 10.1291/hypres.25.351
    • Kubo T, Miyata M, Minagoe S, Setoyama S, Maruyama I, Tei C. A simple oscillometric technique for determining new indices of arterial distensibility. Hypertens Res 2002; 25:351-358. (Pubitemid 34752553)
    • (2002) Hypertension Research , vol.25 , Issue.3 , pp. 351-358
    • Kubo, T.1    Miyata, M.2    Minagoe, S.3    Setoyama, S.4    Maruyama, I.5    Tei, C.6
  • 19
    • 0022976166 scopus 로고
    • Estimation of total arterial compliance: An improved method and evaluation of current methods
    • Liu Z, Brin KP, Yin FC. Estimation of total arterial compliance: an improved method and evaluation of current methods. Am J Physiol 1986; 251:H588-H600.
    • (1986) Am J Physiol , vol.251
    • Liu, Z.1    Brin, K.P.2    Yin, F.C.3
  • 20
    • 0024521543 scopus 로고
    • A concordance correlation coefficient to evaluate reproducibility
    • Lin LI. A concordance correlation coefficient to evaluate reproducibility. Biometrics 1989; 45:255-268.
    • (1989) Biometrics , vol.45 , pp. 255-268
    • Lin, L.I.1
  • 22
    • 81155133883 scopus 로고    scopus 로고
    • Quantification of the calibration error in the transfer function-derived central aortic blood pressures
    • Shih YT, Cheng HM, Sung SH, Hu WC, Chen CH. Quantification of the calibration error in the transfer function-derived central aortic blood pressures. Am J Hypertens 2011; 24:1312-1317.
    • (2011) Am J Hypertens , vol.24 , pp. 1312-1317
    • Shih, Y.T.1    Cheng, H.M.2    Sung, S.H.3    Hu, W.C.4    Chen, C.H.5
  • 23
    • 0037658999 scopus 로고    scopus 로고
    • Pressure wave reflection assessed from the peripheral pulse: Is a transfer function necessary?
    • DOI 10.1161/01.HYP.0000057574.64076.A5
    • Millasseau SC, Patel SJ, Redwood SR, Ritter JM, Chowienczyk PJ. Pressure wave reflection assessed from the peripheral pulse: is a transfer function necessary? Hypertension 2003; 41:1016-1020. (Pubitemid 36548597)
    • (2003) Hypertension , vol.41 , Issue.5 , pp. 1016-1020
    • Millasseau, S.C.1    Patel, S.J.2    Redwood, S.R.3    Ritter, J.M.4    Chowienczyk, P.J.5
  • 24
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1:307-310. (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.