메뉴 건너뛰기




Volumn 30, Issue 4, 2012, Pages 572-578

Cross-sectional investigation of correlation between hepatic steatosis and IVIM perfusion on MR imaging

Author keywords

Diffusion; DW; IVIM; Liver; Perfusion

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; CHILD; CLINICAL ARTICLE; CLINICAL TRIAL; CORRELATION ANALYSIS; CROSS-SECTIONAL STUDY; DIFFUSION; DIFFUSION WEIGHTED IMAGING; DIGESTIVE TRACT PARAMETERS; FEMALE; HUMAN; IMAGE QUALITY; INTRAVOXEL INCOHERENT MOTION PERFUSION; LIVER FAT FRACTION; MALE; NONALCOHOLIC FATTY LIVER; PERFUSION; PRIORITY JOURNAL; PROSPECTIVE STUDY; SCHOOL CHILD; SIGNAL NOISE RATIO;

EID: 84862812492     PISSN: 0730725X     EISSN: 18735894     Source Type: Journal    
DOI: 10.1016/j.mri.2011.12.013     Document Type: Article
Times cited : (35)

References (23)
  • 1
    • 70350155029 scopus 로고    scopus 로고
    • Parametric exploration of the liver by magnetic resonance methods
    • Sijens P.E. Parametric exploration of the liver by magnetic resonance methods. Eur Radiol 2009, 19:2594.
    • (2009) Eur Radiol , vol.19 , pp. 2594
    • Sijens, P.E.1
  • 2
    • 58149179092 scopus 로고    scopus 로고
    • Liver cirrhosis: intravoxel incoherent motion MR imaging - pilot study
    • Luciani A., Vignaud A., Cavet M., et al. Liver cirrhosis: intravoxel incoherent motion MR imaging - pilot study. Radiology 2008, 249:891.
    • (2008) Radiology , vol.249 , pp. 891
    • Luciani, A.1    Vignaud, A.2    Cavet, M.3
  • 3
    • 0032975435 scopus 로고    scopus 로고
    • Diffusion coefficients in abdominal organs and hepatic lesions: evaluation with intravoxel incoherent motion echo-planar MR imaging
    • Yamada I., Aung W., Himeno Y., Nakagawa T., Shibuya H. Diffusion coefficients in abdominal organs and hepatic lesions: evaluation with intravoxel incoherent motion echo-planar MR imaging. Radiology 1999, 210:617.
    • (1999) Radiology , vol.210 , pp. 617
    • Yamada, I.1    Aung, W.2    Himeno, Y.3    Nakagawa, T.4    Shibuya, H.5
  • 4
    • 77649216180 scopus 로고    scopus 로고
    • Diagnosis of cirrhosis with intravoxel incoherent motion diffusion MRI and dynamic contrast-enhanced MRI alone and in combination: preliminary experience
    • Patel J., Sigmund E.E., Rusinek H., et al. Diagnosis of cirrhosis with intravoxel incoherent motion diffusion MRI and dynamic contrast-enhanced MRI alone and in combination: preliminary experience. JMagn Reson Imaging 2010, 31:589.
    • (2010) JMagn Reson Imaging , vol.31 , pp. 589
    • Patel, J.1    Sigmund, E.E.2    Rusinek, H.3
  • 5
    • 0022969218 scopus 로고
    • MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders
    • Le Bihan D., Breton E., Lallemand D., et al. MR imaging of intravoxel incoherent motions: application to diffusion and perfusion in neurologic disorders. Radiology 1986, 161:401.
    • (1986) Radiology , vol.161 , pp. 401
    • Le Bihan, D.1    Breton, E.2    Lallemand, D.3
  • 7
    • 58149200092 scopus 로고    scopus 로고
    • Intravoxel incoherent motion perfusion MR imaging: a wake-up call
    • Le Bihan D. Intravoxel incoherent motion perfusion MR imaging: a wake-up call. Radiology 2008, 249:748.
    • (2008) Radiology , vol.249 , pp. 748
    • Le Bihan, D.1
  • 9
    • 64949095273 scopus 로고    scopus 로고
    • Nonalcoholic fatty liver disease: diagnostic and fat-grading accuracy of low-flip-angle multiecho gradient-recalled-echo MR imaging at 1.5 T
    • Yokoo T., Bydder M., Hamilton G., Middleton M.S., Gamst A.C., Wolfson T., et al. Nonalcoholic fatty liver disease: diagnostic and fat-grading accuracy of low-flip-angle multiecho gradient-recalled-echo MR imaging at 1.5 T. Radiology 2009, 251:67.
    • (2009) Radiology , vol.251 , pp. 67
    • Yokoo, T.1    Bydder, M.2    Hamilton, G.3    Middleton, M.S.4    Gamst, A.C.5    Wolfson, T.6
  • 13
    • 0033005487 scopus 로고    scopus 로고
    • Hepatic iron concentration: noninvasive estimation by means of MR imaging techniques
    • Bonkovsky H.L. Hepatic iron concentration: noninvasive estimation by means of MR imaging techniques. Radiology 1999, 212:227.
    • (1999) Radiology , vol.212 , pp. 227
    • Bonkovsky, H.L.1
  • 15
    • 23744459788 scopus 로고    scopus 로고
    • * mapping accurately estimates hepatic iron concentration in transfusion-dependent thalassemia and sickle cell disease patients
    • * mapping accurately estimates hepatic iron concentration in transfusion-dependent thalassemia and sickle cell disease patients. Blood 2005, 106:1460.
    • (2005) Blood , vol.106 , pp. 1460
    • Wood, J.C.1    Enriquez, C.2    Ghugre, N.3
  • 16
    • 77950901793 scopus 로고    scopus 로고
    • Liver iron content determination by magnetic resonance imaging
    • Tziomalos K., Perifanis V. Liver iron content determination by magnetic resonance imaging. World J Gastroenterol 2010, 16:1587.
    • (2010) World J Gastroenterol , vol.16 , pp. 1587
    • Tziomalos, K.1    Perifanis, V.2
  • 18
    • 0033610273 scopus 로고    scopus 로고
    • The effect of graded steatosis on flow in the hepatic parenchymal microcirculation
    • Seifalian A.M., Piasecki C., Agarwal A., Davidson B.R. The effect of graded steatosis on flow in the hepatic parenchymal microcirculation. Transplantation 1999, 68(6):780.
    • (1999) Transplantation , vol.68 , Issue.6 , pp. 780
    • Seifalian, A.M.1    Piasecki, C.2    Agarwal, A.3    Davidson, B.R.4
  • 19
    • 0031973742 scopus 로고    scopus 로고
    • In vivo demonstration of impaired microcirculation in steatotic human liver grafts
    • Seifalian A.M., Chidambaram V., Rolles K., Davidson B.R. In vivo demonstration of impaired microcirculation in steatotic human liver grafts. Liver Transpl 1998, 4:71.
    • (1998) Liver Transpl , vol.4 , pp. 71
    • Seifalian, A.M.1    Chidambaram, V.2    Rolles, K.3    Davidson, B.R.4
  • 20
    • 78049238673 scopus 로고    scopus 로고
    • Liver fat content in type 2 diabetes: relationship with hepatic perfusion and substrate metabolism
    • Rijzewijk L.J., van der Meer R.W., Lubberink M., Lamb H.J., Romijn J.A., de Roos A., et al. Liver fat content in type 2 diabetes: relationship with hepatic perfusion and substrate metabolism. Diabetes 2010, 59:2747.
    • (2010) Diabetes , vol.59 , pp. 2747
    • Rijzewijk, L.J.1    van der Meer, R.W.2    Lubberink, M.3    Lamb, H.J.4    Romijn, J.A.5    de Roos, A.6
  • 21
    • 33748264591 scopus 로고    scopus 로고
    • Evaluation of hepatic lesions and hepatic parenchyma using diffusion-weighted echo-planar MR with three values of gradient b-factor
    • Moteki T., Horikoshi H. Evaluation of hepatic lesions and hepatic parenchyma using diffusion-weighted echo-planar MR with three values of gradient b-factor. J Magn Reson Imaging 2006, 24:637.
    • (2006) J Magn Reson Imaging , vol.24 , pp. 637
    • Moteki, T.1    Horikoshi, H.2
  • 22
    • 0026216918 scopus 로고
    • Multipoint Dixon technique for water and fat proton and susceptibility imaging
    • Glover G.H. Multipoint Dixon technique for water and fat proton and susceptibility imaging. J Magn Reson Imaging 1991, 1:521.
    • (1991) J Magn Reson Imaging , vol.1 , pp. 521
    • Glover, G.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.