메뉴 건너뛰기




Volumn 83, Issue 2, 2012, Pages

Surface dose investigation of the flattening filter-free photon beams

Author keywords

Buildup region; Flattening filter free; Skin dose; Surface dose

Indexed keywords

BUILD-UP REGION; CLINICAL OPERATIONS; DOSE MEASUREMENT; DOSE RATE; FIELD SIZE; FLATTENING FILTERS; MULTILEAF COLLIMATORS; PARALLEL PLATES; PHOTON BEAMS; SKIN DOSE; SOLID WATER; STEREOTACTIC BODY RADIOTHERAPY; STEREOTACTIC RADIOSURGERY; SURFACE DOSE; TREATMENT PLANNING SYSTEMS; X RAY PHOTONS;

EID: 84862796342     PISSN: 03603016     EISSN: 1879355X     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2011.12.064     Document Type: Article
Times cited : (58)

References (21)
  • 1
    • 79952148081 scopus 로고    scopus 로고
    • Current status and future perspective of flattening filter free photon beams
    • D. Georg, T. Knöös, and B. McClean Current status and future perspective of flattening filter free photon beams Med Phys 38 2011 1280 1293
    • (2011) Med Phys , vol.38 , pp. 1280-1293
    • Georg, D.1    Knöös, T.2    McClean, B.3
  • 2
    • 85018625901 scopus 로고    scopus 로고
    • Treatment planning study: Flattening filter free x-rays vs. conventional flattened x-rays for stereotactic body radiation therapy of stage 1A non-small cell lung cancer (NSCLC)
    • Presented at the
    • Wang Y, Golden N, Ting JY. Treatment planning study: Flattening filter free x-rays vs. conventional flattened x-rays for stereotactic body radiation therapy of stage 1A non-small cell lung cancer (NSCLC). Presented at the 2011 annual meeting of the Radiological Society of North America, Chicago, IL.
    • 2011 Annual Meeting of the Radiological Society of North America, Chicago, IL
    • Wang, Y.1    Golden, N.2    Ting, J.Y.3
  • 3
    • 70049115354 scopus 로고    scopus 로고
    • Stereotactic radiotherapy for lung cancer using a flattening filter free linac
    • O.N. Vassiliev, S.F. Kry, and J.Y. Chang Stereotactic radiotherapy for lung cancer using a flattening filter free linac J Appl Clin Med Phys 10 2009 14 21
    • (2009) J Appl Clin Med Phys , vol.10 , pp. 14-21
    • Vassiliev, O.N.1    Kry, S.F.2    Chang, J.Y.3
  • 4
    • 78650036852 scopus 로고    scopus 로고
    • Flattening filter free beams in SBRT and IMRT: Dosimetric assessment of peripheral doses
    • G. Kragl, F. Baier, and S. Lutz Flattening filter free beams in SBRT and IMRT: Dosimetric assessment of peripheral doses Z Med Phys 21 2011 91 101
    • (2011) Z Med Phys , vol.21 , pp. 91-101
    • Kragl, G.1    Baier, F.2    Lutz, S.3
  • 5
    • 77950559016 scopus 로고    scopus 로고
    • Out-of-field photon dose following removal of the flattening filter from a medical accelerator
    • S.F. Kry, O.N. Vassiliev, and R. Mohan Out-of-field photon dose following removal of the flattening filter from a medical accelerator Phys Med Biol 55 2010 2155 2166
    • (2010) Phys Med Biol , vol.55 , pp. 2155-2166
    • Kry, S.F.1    Vassiliev, O.N.2    Mohan, R.3
  • 6
    • 33645283656 scopus 로고    scopus 로고
    • Dosimetric properties of photon beams from a flattening filter free clinical accelerator
    • O.N. Vassiliev, U. Titt, and F. Ponisch Dosimetric properties of photon beams from a flattening filter free clinical accelerator Phys Med Biol 51 2006 1907 1917
    • (2006) Phys Med Biol , vol.51 , pp. 1907-1917
    • Vassiliev, O.N.1    Titt, U.2    Ponisch, F.3
  • 7
    • 84862831674 scopus 로고    scopus 로고
    • Application of non flat beams for breast radiotherapy using direct aperture optimization
    • Y. Wang, S. Gajdos, and R. Tendulkar Application of non flat beams for breast radiotherapy using direct aperture optimization Med Phys 37 2010 3215
    • (2010) Med Phys , vol.37 , pp. 3215
    • Wang, Y.1    Gajdos, S.2    Tendulkar, R.3
  • 9
    • 79959344605 scopus 로고    scopus 로고
    • Commissioning of photon beams of a flattening filter-free linear accelerator and the accuracy of beam modeling using an anisotropic analytical algorithm
    • J. Hrbacek, S. Lang, and S. Klöck Commissioning of photon beams of a flattening filter-free linear accelerator and the accuracy of beam modeling using an anisotropic analytical algorithm Int J Radiat Oncol Biol Phys 80 2011 1228 1237
    • (2011) Int J Radiat Oncol Biol Phys , vol.80 , pp. 1228-1237
    • Hrbacek, J.1    Lang, S.2    Klöck, S.3
  • 10
    • 70349315242 scopus 로고    scopus 로고
    • Dosimetric characteristics of 6 and 10MV unflattened photon beams
    • G. Kragl, S. af Wetterstedt, and B. Knäusl Dosimetric characteristics of 6 and 10MV unflattened photon beams Radiother Oncol 93 2009 141 146
    • (2009) Radiother Oncol , vol.93 , pp. 141-146
    • Kragl, G.1    Af Wetterstedt, S.2    Knäusl, B.3
  • 11
    • 42449146199 scopus 로고    scopus 로고
    • The characterization of unflattened photon beams from a 6 MV linear accelerator
    • DOI 10.1088/0031-9155/53/7/009, PII S0031915508667275
    • J. Cashmore The characterization of unflattened photon beams from a 6 MV linear accelerator Phys Med Biol 53 2008 1933 1946 (Pubitemid 351570900)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.7 , pp. 1933-1946
    • Cashmore, J.1
  • 13
    • 0003954913 scopus 로고    scopus 로고
    • 3rd ed. Lippincott Williams & Wilkins Philadelphia
    • F.M. Khan Physics of radiation therapy 3rd ed. 2003 Lippincott Williams & Wilkins Philadelphia
    • (2003) Physics of Radiation Therapy
    • Khan, F.M.1
  • 14
    • 81755180013 scopus 로고    scopus 로고
    • Prediction of chest wall toxicity from lung stereotactic body radiotherapy (SBRT)
    • In Press, Corrected Proof
    • K.L. Stephans, T. Djemil, and R.D. Tendulkar Prediction of chest wall toxicity from lung stereotactic body radiotherapy (SBRT) Int J Radiat Oncol Biol Phys 2011 In Press, Corrected Proof
    • (2011) Int J Radiat Oncol Biol Phys
    • Stephans, K.L.1    Djemil, T.2    Tendulkar, R.D.3
  • 16
    • 0026695986 scopus 로고
    • Design of parallel plate ion chambers for buildup measurements in megavoltage photon beams
    • J.A. Rawlinson, D. Arlen, and D. Newcombe Design of parallel plate ion chambers for buildup measurements in megavoltage photon beams Med Phys 19 1992 641 648
    • (1992) Med Phys , vol.19 , pp. 641-648
    • Rawlinson, J.A.1    Arlen, D.2    Newcombe, D.3
  • 17
    • 0025021187 scopus 로고
    • Measurement of dose in the buildup region using fixed-separation plane-parallel ionization chambers
    • DOI 10.1118/1.596522
    • B.J. Gerbi, and F.M. Khan Measurement of dose in the buildup region using fixed-separation plane-parallel ionization chambers Med Phys 17 1990 17 26 (Pubitemid 20073163)
    • (1990) Medical Physics , vol.17 , Issue.1 , pp. 17-26
    • Gerbi, B.J.1    Khan, F.M.2
  • 20
    • 85024948889 scopus 로고    scopus 로고
    • Surface and buildup dose characteristics for 6, 10, and 18 MV photons from an Elekta Precise linear accelerator
    • E.E. Klein, J. Esthappan, and Z. Li Surface and buildup dose characteristics for 6, 10, and 18 MV photons from an Elekta Precise linear accelerator J Appl Clin Med Phys 4 2003 1 7
    • (2003) J Appl Clin Med Phys , vol.4 , pp. 1-7
    • Klein, E.E.1    Esthappan, J.2    Li, Z.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.