Volumn 46, Issue 12, 2012, Pages 6759-6766

Transfer kinetics of polar organic compounds over polyethersulfone membranes in the passive samplers pocis and chemcatcher

Author keywords

[No Author keywords available]

Indexed keywords

AQUEOUS CONCENTRATIONS; DICLOFENAC; ELIMINATION RATE; FIRST-ORDER KINETIC MODELS; HYDROPHOBIC CHEMICALS; KINETIC REGIME; OCTANOL-WATER PARTITIONING; PARTITIONING COEFFICIENTS; PASSIVE SAMPLERS; PASSIVE SAMPLING; PES MEMBRANES; POLAR ORGANIC CHEMICALS; POLAR ORGANIC COMPOUNDS; POLYETHERSULFONE MEMBRANE; RIVER WATER; SAMPLING RATES; SIMILAR PATTERN; SORBENT MATERIALS; SORPTION KINETICS; TIME-WEIGHTED AVERAGES; TRANSFER KINETICS; TRANSPORT KINETIC; UPTAKE KINETICS;

EID: 84862546241     PISSN: 0013936X     EISSN: 15205851     Source Type: Journal    
DOI: 10.1021/es3007854     Document Type: Article
Times cited : (135)

References (21)
  • 1
    • 72849146834 scopus 로고    scopus 로고
    • Passive sampling as a tool for obtaining reliable analytical information in environmental quality monitoring
    • Zabiegała, B.; Kot-Wasik, A.; Urbanowicz, M.; Namieśnik, J. Passive sampling as a tool for obtaining reliable analytical information in environmental quality monitoring. Anal. Bioanal. Chem. 2010, 396 (1), 273-296.
    • (2010) Anal. Bioanal. Chem. , vol.396 , Issue.1 , pp. 273-296
    • Zabiegała, B.1    Kot-Wasik, A.2    Urbanowicz, M.3    Namieśnik, J.4
  • 4
    • 0033793191 scopus 로고    scopus 로고
    • Development of a novel passive sampling system for the time-averaged measurement of a range of organic pollutants in aquatic environments
    • Kingston, J. K.; Greenwood, R.; Mills, G. A.; Morrison, G. M.; Persson, L. B. Development of a novel passive sampling system for the time-averaged measurement of a range of organic pollutants in aquatic environments. J. Environ. Monit. 2000, 2 (5), 487-495.
    • (2000) J. Environ. Monit. , vol.2 , Issue.5 , pp. 487-495
    • Kingston, J.K.1    Greenwood, R.2    Mills, G.A.3    Morrison, G.M.4    Persson, L.B.5
  • 5
    • 37249031971 scopus 로고    scopus 로고
    • Analysis of emerging contaminants in sewage effluent and river water: Comparison between spot and passive sampling
    • DOI 10.1016/j.aca.2007.11.024, PII S0003267007019101
    • Zhang, Z.; Hibberd, A.; Zhou, J. L. Analysis of emerging contaminants in sewage effluent and river water: comparison between spot and passive sampling. Anal. Chim. Acta 2008, 607 (1), 37-44. (Pubitemid 350266557)
    • (2008) Analytica Chimica Acta , vol.607 , Issue.1 , pp. 37-44
    • Zhang, Z.1    Hibberd, A.2    Zhou, J.L.3
  • 6
    • 34047172167 scopus 로고    scopus 로고
    • Calibration of a passive sampling device for time-integrated sampling of hydrophilic herbicides in aquatic environments
    • DOI 10.1897/06-401R.1
    • Tran, A. T. K.; Hyne, R. V.; Doble, P. Calibration of a passive sampling device for time-integrated sampling of hydrophilic herbicides in aquatic environments. Environ. Toxicol. Chem. 2007, 26 (3), 435-443. (Pubitemid 46512148)
    • (2007) Environmental Toxicology and Chemistry , vol.26 , Issue.3 , pp. 435-443
    • Tran, A.T.K.1    Hyne, R.V.2    Doble, P.3
  • 7
    • 60549090991 scopus 로고    scopus 로고
    • Passive sampling combined with ecotoxicological and chemical analysis of pharmaceuticals and biocides - Evaluation of three Chemcatcher configurations
    • Vermeirssen, E. L. M.; Bramaz, N.; Hollender, J.; Singer, H.; Escher, B. I. Passive sampling combined with ecotoxicological and chemical analysis of pharmaceuticals and biocides - evaluation of three Chemcatcher configurations. Water Res. 2009, 43, 903-914.
    • (2009) Water Res. , vol.43 , pp. 903-914
    • Vermeirssen, E.L.M.1    Bramaz, N.2    Hollender, J.3    Singer, H.4    Escher, B.I.5
  • 8
    • 75349096657 scopus 로고    scopus 로고
    • Calibration of silicone rubber passive samplers: Experimental and modeled relations between sampling rate and compound properties
    • Rusina, T. P.; Smedes, F.; Koblizkova, M.; Klanova, J. Calibration of silicone rubber passive samplers: experimental and modeled relations between sampling rate and compound properties. Environ. Sci. Technol. 2010, 44 (1), 362-367.
    • (2010) Environ. Sci. Technol. , vol.44 , Issue.1 , pp. 362-367
    • Rusina, T.P.1    Smedes, F.2    Koblizkova, M.3    Klanova, J.4
  • 9
    • 33746716860 scopus 로고    scopus 로고
    • Contamination of headwater streams in the United Kingdom by oestrogenic hormones from livestock farms
    • DOI 10.1016/j.scitotenv.2006.02.007, PII S0048969706001148
    • Matthiessen, P.; Arnold, D.; Johnson, A. C.; Pepper, T. J.; Pottinger, T. G.; Pulman, K. G. T. Contamination of headwater streams in the United Kingdom by oestrogenic hormones from livestock farms. Sci. Total Environ. 2006, 367 (2-3), 616-630. (Pubitemid 44160494)
    • (2006) Science of the Total Environment , vol.367 , Issue.2-3 , pp. 616-630
    • Matthiessen, P.1    Arnold, D.2    Johnson, A.C.3    Pepper, T.J.4    Pottinger, T.G.5    Pulman, K.G.T.6
  • 10
    • 37049030403 scopus 로고    scopus 로고
    • Laboratory calibration and field deployment of the polar organic chemical integrative sampler for pharmaceuticals and personal care products in wastewater and surface water
    • DOI 10.1897/07-238.1
    • MacLeod, S. L.; McClure, E. L.; Wong, C. S. Laboratory calibration and field deployment of the polar organic chemical integrative sampler for pharmaceuticals and personal care products in wastewater and surface water. Environ. Toxicol. Chem. 2007, 26 (1), 2517-2529. (Pubitemid 350247107)
    • (2007) Environmental Toxicology and Chemistry , vol.26 , Issue.12 , pp. 2517-2529
    • MacLeod, S.L.1    McClure, E.L.2    Wong, C.S.3
  • 11
    • 0032145408 scopus 로고    scopus 로고
    • Three-compartment model for contaminant accumulation by semipermeable membrane devices
    • DOI 10.1021/es970754m
    • Gale, R. W. Three-compartment model for contaminant accumulation by semipermeable membrane devices. Environ. Sci. Technol. 1998, 32 (15), 2292-2300. (Pubitemid 28359868)
    • (1998) Environmental Science and Technology , vol.32 , Issue.15 , pp. 2292-2300
    • Gale, R.W.1
  • 12
    • 78649612277 scopus 로고    scopus 로고
    • Linking toxicity in algal and bacterial assays with chemical analysis in passive samplers deployed in 21 treated sewage effluents
    • Vermeirssen, E. L. M.; Hollender, J.; Bramaz, N.; van der Voet, J.; Escher, B. I. Linking toxicity in algal and bacterial assays with chemical analysis in passive samplers deployed in 21 treated sewage effluents. Environ. Toxicol. Chem. 2010, 29 (11), 2575-2582.
    • (2010) Environ. Toxicol. Chem. , vol.29 , Issue.11 , pp. 2575-2582
    • Vermeirssen, E.L.M.1    Hollender, J.2    Bramaz, N.3    Van Der Voet, J.4    Escher, B.I.5
  • 13
    • 78649622163 scopus 로고    scopus 로고
    • Controlled field evaluation of water flow rate effects on sampling polar organic compounds using polar organic chemical integrative samplers
    • Li, H.; Vermeirssen, E. L. M.; Helm, P. A.; Metcalfe, C. Controlled field evaluation of water flow rate effects on sampling polar organic compounds using polar organic chemical integrative samplers. Environ. Toxicol. Chem. 2010, 29 (11), 2461-2469.
    • (2010) Environ. Toxicol. Chem. , vol.29 , Issue.11 , pp. 2461-2469
    • Li, H.1    Vermeirssen, E.L.M.2    Helm, P.A.3    Metcalfe, C.4
  • 14
    • 37849000529 scopus 로고    scopus 로고
    • The role of hydrodynamics, matrix and sampling duration in passive sampling of polar compounds with Empore SDB-RPS disks
    • Vermeirssen, E. L. M.; Asmin, J.; Escher, B. I.; Kwon, J.-H.; Steimen, I.; Hollender, J. The role of hydrodynamics, matrix and sampling duration in passive sampling of polar compounds with Empore SDB-RPS disks. J. Environ. Monit. 2008, 10, 119-128.
    • (2008) J. Environ. Monit. , vol.10 , pp. 119-128
    • Vermeirssen, E.L.M.1    Asmin, J.2    Escher, B.I.3    Kwon, J.-H.4    Steimen, I.5    Hollender, J.6
  • 15
    • 34249774893 scopus 로고    scopus 로고
    • Determination of kinetic and equilibrium regimes in the operation of polar organic chemical integrative samplers. Application to the passive sampling of the polar herbicides in aquatic environments
    • DOI 10.1016/j.chroma.2007.03.087, PII S0021967307006139
    • Mazzella, N.; Dubernet, J.-F.; Delmas, F. Determination of kinetic and equilibrium regimes in the operation of polar organic chemical integrative samplers: Application to the passive sampling of the polar herbicides in aquatic environments. J. Chromatogr., A 2007, 1154 (1-2), 42-51. (Pubitemid 46850739)
    • (2007) Journal of Chromatography A , vol.1154 , Issue.1-2 , pp. 42-51
    • Mazzella, N.1    Dubernet, J.-F.2    Delmas, F.3
  • 16
    • 77958164404 scopus 로고    scopus 로고
    • Determination of biocides and pesticides by on-line solid phase extraction coupled with mass spectrometry and their behaviour in wastewater and surface water
    • Singer, H.; Jaus, S.; Hanke, I.; Lück, A.; Hollender, J.; Alder, A. C. Determination of biocides and pesticides by on-line solid phase extraction coupled with mass spectrometry and their behaviour in wastewater and surface water. Environ. Pollut. 2010, 158 (10), 3054-3064.
    • (2010) Environ. Pollut. , vol.158 , Issue.10 , pp. 3054-3064
    • Singer, H.1    Jaus, S.2    Hanke, I.3    Lück, A.4    Hollender, J.5    Alder, A.C.6
  • 18
    • 47349128119 scopus 로고    scopus 로고
    • Uptake rates of alkylphenols, PAHs and carbazoles in semipermeable membrane devices (SPMDs) and polar organic chemical integrative samplers (POCIS)
    • Harman, C.; Tollefsen, K. E.; Bøyum, O.; Thomas, K.; Grung, M. Uptake rates of alkylphenols, PAHs and carbazoles in semipermeable membrane devices (SPMDs) and polar organic chemical integrative samplers (POCIS). Chemosphere 2008, 72 (10), 1510-1516.
    • (2008) Chemosphere , vol.72 , Issue.10 , pp. 1510-1516
    • Harman, C.1    Tollefsen, K.E.2    Bøyum, O.3    Thomas, K.4    Grung, M.5
  • 19
    • 61549128983 scopus 로고    scopus 로고
    • Uptake and release of polar compounds in SDB-RPS Empore disks; implications for their use as passive samplers
    • Shaw, M.; Eaglesham, G.; Mueller, J. F. Uptake and release of polar compounds in SDB-RPS Empore disks; implications for their use as passive samplers. Chemosphere 2009, 75 (1), 1-7.
    • (2009) Chemosphere , vol.75 , Issue.1 , pp. 1-7
    • Shaw, M.1    Eaglesham, G.2    Mueller, J.F.3
  • 20
    • 77749261119 scopus 로고    scopus 로고
    • Evaluation of the use of performance reference compounds in an Oasis-HLB adsorbent based passive sampler for improving water concentration estimates of polar herbicides in freshwater
    • Mazzella, N.; Lissalde, S.; Moreira, S.; Delmas, F.; Mazellier, P.; Huckins, J. N. Evaluation of the use of performance reference compounds in an Oasis-HLB adsorbent based passive sampler for improving water concentration estimates of polar herbicides in freshwater. Environ. Sci. Technol. 2010, 44 (5), 1713-1719.
    • (2010) Environ. Sci. Technol. , vol.44 , Issue.5 , pp. 1713-1719
    • Mazzella, N.1    Lissalde, S.2    Moreira, S.3    Delmas, F.4    Mazellier, P.5    Huckins, J.N.6
  • 21
    • 79951702600 scopus 로고    scopus 로고
    • Liquid chromatography coupled with tandem mass spectrometry method for thirty-three pesticides in natural water and comparison of performance between classical solid phase extraction and passive sampling approaches
    • Lissalde, S.; Mazzella, N.; Fauvelle, V.; Delmas, F.; Mazellier, P.; Legube, B. Liquid chromatography coupled with tandem mass spectrometry method for thirty-three pesticides in natural water and comparison of performance between classical solid phase extraction and passive sampling approaches. J. Chromatogr., A 2011, 1218 (11), 1492-1502.
    • (2011) J. Chromatogr., A , vol.1218 , Issue.11 , pp. 1492-1502
    • Lissalde, S.1    Mazzella, N.2    Fauvelle, V.3    Delmas, F.4    Mazellier, P.5    Legube, B.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.