-
1
-
-
0027338901
-
Lipid-containing semipermeable membrane devices for monitoring organic contaminants in water
-
Huckins, J. N.; Manuweera, G. K.; Petty, J. D.; Mackay, D.; Lebo, J. A. Lipid-containing semipermeable membrane devices for monitoring organic contaminants in water. Environ. Sci. Technol. 1993, 27, 2489-2496.
-
(1993)
Environ. Sci. Technol.
, vol.27
, pp. 2489-2496
-
-
Huckins, J.N.1
Manuweera, G.K.2
Petty, J.D.3
Mackay, D.4
Lebo, J.A.5
-
2
-
-
2942521051
-
Development of a passive, in situ, integrative sampler for hydrophilic organic contaminants in aquatic environments
-
Alvarez, D. A.; Petty, J. D.; Huckins, J. N.; lones-Lepp, T. L.; Getting, D. T.; Goddard, J. P.; Manahan, S. E. Development of a passive, in situ, integrative sampler for hydrophilic organic contaminants in aquatic environments. Environ. Toxicol. Chem. 2004, 23 (7), 1640-1648.
-
(2004)
Environ. Toxicol. Chem.
, vol.23
, Issue.7
, pp. 1640-1648
-
-
Alvarez, D.A.1
Petty, J.D.2
Huckins, J.N.3
Lones-Lepp, T.L.4
Getting, D.T.5
Goddard, J.P.6
Manahan, S.E.7
-
3
-
-
0003186730
-
Establishing a framework for community action in the field of water policy
-
2000/60/EC, Directive 2000/60/EC of the European Parliament and of the Council of 23 October 22.12.2000
-
-2000/60/EC, Directive 2000/60/EC of the European Parliament and of the Council of 23 October 2000 Establishing a Framework for Community Action in the Field of Water Policy. OJ L 327, 22.12.2000, 1-73.
-
(2000)
OJ L
, vol.327
, pp. 1-73
-
-
-
4
-
-
0033230575
-
Determination of uptake kinetics (sampling rates) by Lipid-containing semipermeable membrane devices (SPMDs) for polycyclic aromatic hydrocarbons (PAHs) in water
-
Huckins, J. N.; Petty, J. D.; Orazio, C. E.; Lebo, J. A; Clark, R. C.; Gibson, V. L.; Gala, W. R.; Echols, K. R. Determination of Uptake Kinetics (Sampling Rates) by Lipid-Containing Semipermeable Membrane Devices (SPMDs) for Polycyclic Aromatic Hydrocarbons (PAHs) in Water. Environ. Sci. Technol 1999, 33 (21), 3918-3923.
-
(1999)
Environ. Sci. Technol
, vol.33
, Issue.21
, pp. 3918-3923
-
-
Huckins, J.N.1
Petty, J.D.2
Orazio, C.E.3
Lebo, J.A.4
Clark, R.C.5
Gibson, V.L.6
Gala, W.R.7
Echols, K.R.8
-
5
-
-
0034685686
-
Considerations involved with the use of semipermeable membrane devices for monitoring environmental contaminants
-
Petty, J. D.; Orazio, C. E.; Huckins, J. N.; Gale, R. W.; Lebo, J. A.; Meadows, J. C.; Echols, K. R.; Cranor, W. J. Considerations involved with the use of semipermeable membrane devices for monitoring environmental contaminants. J. Chromatogr., A 2000, 879 (1), 83-95.
-
(2000)
J. Chromatogr., A
, vol.879
, Issue.1
, pp. 83-95
-
-
Petty, J.D.1
Orazio, C.E.2
Huckins, J.N.3
Gale, R.W.4
Lebo, J.A.5
Meadows, J.C.6
Echols, K.R.7
Cranor, W.J.8
-
6
-
-
33646406804
-
Calibration of the Chemcatcher passive sampler for the monitoring of priority organic pollutants in water
-
DOI 10.1016/j.envpol.2005.10.033, PII S026974910500518X
-
Vrana, B.; Mills, G. A.; Domfniak, E.; Greenwood, R. Calibration of the Chemcatcher passive sampler for the monitoring of priority organic pollutants in water. Environ. Pollut. 2006, 142, 333-343. (Pubitemid 43675705)
-
(2006)
Environmental Pollution
, vol.142
, Issue.2
, pp. 333-343
-
-
Vrana, B.1
Mills, G.A.2
Dominiak, E.3
Greenwood, R.4
-
7
-
-
50949111071
-
Comparison between the polar organic chemical integrative sampler and the solidphase extraction for estimating herbicide time-weighted average concentrations during a microcosm experiment
-
Mazzella, N.; Debenest, T.; Delmas, F. Comparison between the polar organic chemical integrative sampler and the solidphase extraction for estimating herbicide time-weighted average concentrations during a microcosm experiment. Chemosphere 2008, 73, 545-550.
-
(2008)
Chemosphere
, vol.73
, pp. 545-550
-
-
Mazzella, N.1
Debenest, T.2
Delmas, F.3
-
8
-
-
37049030403
-
Laboratory calibration and field deployment of the polar organic chemical integrative sampler for pharmaceuticals and personalcare products in wastewater and surface water
-
Macleod, S. L.; McClure, E. L.; Wong, C. S. Laboratory calibration and field deployment of the polar organic chemical integrative sampler for pharmaceuticals and personalcare products in wastewater and surface water. Environ. Toxicol. Chem. 2007, 26, 2517-2529.
-
(2007)
Environ. Toxicol. Chem.
, vol.26
, pp. 2517-2529
-
-
Macleod, S.L.1
McClure, E.L.2
Wong, C.S.3
-
9
-
-
37849000529
-
The role of hydrodynamics, matrix and sampling duration in passive sampling of polar compounds with Empore SDB-RPS disks
-
Vermeirssen, E. L. M.; Asmfn, J.; Escher, B. I.; Kwon, J.-H.; Steimen, L.; Hallender, J. The role of hydrodynamics, matrix and sampling duration in passive sampling of polar compounds with Empore SDB-RPS disks. J. Environ. Monit. 2008, 10, 119-128.
-
(2008)
J. Environ. Monit.
, vol.10
, pp. 119-128
-
-
Vermeirssen, E.L.M.1
Asmfn, J.2
Escher, B.I.3
Kwon, J.-H.4
Steimen, L.5
Hallender, J.6
-
10
-
-
0036140511
-
Development of the permeability/performance reference compound approach for in situ calibration of semipermeable membrane devices
-
Huckins, J. N.; Petty, J. D.; Lebo, J. A.; Almeida, F. V.; Booij, K.; Alvarez, D. A.; Cranor, W. L.; Clark, R. C.; Mogensen, B. B. Development of the permeability/performance reference compound approach for in situ calibration of semipermeable membrane devices. Environ. Sci. Technol. 2002, 36(1), 85-91.
-
(2002)
Environ. Sci. Technol.
, vol.36
, Issue.1
, pp. 85-91
-
-
Huckins, J.N.1
Petty, J.D.2
Lebo, J.A.3
Almeida, F.V.4
Booij, K.5
Alvarez, D.A.6
Cranor, W.L.7
Clark, R.C.8
Mogensen, B.B.9
-
12
-
-
58149373832
-
Investigation of the matrix effects on a HPLC-ESI-MS/MS method and application for monitoring triazine, phenylurea and chloroacetanilide concentrations in fresh and estuarine waters
-
Mazzella, N.; Delmas, F.; Delest, B.; Méchin, B.; Madigou, C.; Alienou, J.-P.; Gabellec, R.; Caquet, T. Investigation of the matrix effects on a HPLC-ESI-MS/MS method and application for monitoring triazine, phenylurea and chloroacetanilide concentrations in fresh and estuarine waters. J. Environ. Monit. 2009, 11, 108-115.
-
(2009)
J. Environ. Monit.
, vol.11
, pp. 108-115
-
-
Mazzella, N.1
Delmas, F.2
Delest, B.3
Méchin, B.4
Madigou, C.5
Alienou, J.-P.6
Gabellec, R.7
Caquet, T.8
-
13
-
-
34249774893
-
Determination of kinetic and equilibrium regimes in the operation of polar organic chemical integrative samplers. Application to the passive sampling of the polar herbicides in aquatic environments
-
DOI 10.1016/j.chroma.2007.03.087, PII S0021967307006139
-
Mazzella, N.; Dubernet, J.-F.; Delmas, F. Determination of kinetic and equilibrium regimes in the operation of polar organic chemical integrative samplers: Application to the passive sampling of the polar herbicides in aquatic environments. T. Chromatoer., A 2007, 1154 (1-2), 42-51. (Pubitemid 46850739)
-
(2007)
Journal of Chromatography A
, vol.1154
, Issue.1-2
, pp. 42-51
-
-
Mazzella, N.1
Dubernet, J.-F.2
Delmas, F.3
-
14
-
-
85083131821
-
-
3rd International Passive Sampler Workshop and Symposium, Prague
-
Huckins, J.; Alvarez, D.; Booij, K.; Mazzella, N.; Mueller, J. In Background and Thoughts About the Use of Passive Samplers EmployingPorous Polymeric Resins for Moderately Polar to Polar Analytes, 3rd International Passive Sampler Workshop and Symposium, Prague, 2009; http://81.30.244.20/ ipsw2009/.
-
(2009)
Background and Thoughts about the Use of Passive Samplers EmployingPorous Polymeric Resins for Moderately Polar to Polar Analytes
-
-
Huckins, J.1
Alvarez, D.2
Booij, K.3
Mazzella, N.4
Mueller, J.5
-
15
-
-
0033063816
-
Theory of analyte extraction by selected porous polymer SPME fibres
-
DOI 10.1039/a808487d
-
Góreckí, T.; Yu, X.; Pawliszyn, J. Theory of analyte extraction by selected porous polymer SPME fibres. Analyst 1999, 124, 643649. (Pubitemid 29245791)
-
(1999)
Analyst
, vol.124
, Issue.5
, pp. 643-649
-
-
Gorecki, T.1
Yu, X.2
Pawliszyn, J.3
-
16
-
-
27944443729
-
Passive sampling techniques for monitoring pollutants in water
-
DOI 10.1016/j.trac.2005.06.006, PII S0165993605001743
-
Vrana, B.; Allan, I. J.; Greenwood, R.; Mills, G. A; Dominiak, E.; Svensson, K.; Knutsson, J.; Morrison, G. Passive sampling techniques for monitoring pollutants in water. Trends Anal. Chem. 2005, 24 (10), 845-868. (Pubitemid 41677610)
-
(2005)
TrAC - Trends in Analytical Chemistry
, vol.24
, Issue.10
, pp. 845-868
-
-
Vrana, B.1
Allan, I.J.2
Greenwood, R.3
Mills, G.A.4
Dominiak, E.5
Svensson, K.6
Knutsson, J.7
Morrison, G.8
-
17
-
-
0037940177
-
Sample preparation: Quo vadis?
-
Pawliszyn, J. Sample Preparation: Quo Vadis? Anal. Chem. 2003, 75(11), 2543-2558.
-
(2003)
Anal. Chem.
, vol.75
, Issue.11
, pp. 2543-2558
-
-
Pawliszyn, J.1
-
18
-
-
0032145408
-
Three-compartment model for contaminant accumulation by semipermeable membrane devices
-
Gale, R. W. Three-compartment model for contaminant accumulation by semipermeable membrane devices. Environ. Sci. Technol. 1998, 32, 2292-2300.
-
(1998)
Environ. Sci. Technol.
, vol.32
, pp. 2292-2300
-
-
Gale, R.W.1
-
19
-
-
84892830279
-
-
Springer Science+Business Media: New York, NY
-
Huckins, J. N.; Petty, J. D.; Booij, K., Monitors of Organic Chemicals in the Environment: Semipermeable Membrane Devices. Springer Science+Business Media: New York, NY, 2006; p 223.
-
(2006)
Monitors of Organic Chemicals in the Environment: Semipermeable Membrane Devices
, pp. 223
-
-
Huckins, J.N.1
Petty, J.D.2
Booij, K.3
-
20
-
-
33846524903
-
And field application of the Chemcatcher passive sampler calibration data for the monitoring of hydrophobic organic pollutants in water
-
Vrana, B.; Mills, G. A.; Kotterman, M.; Leonards, P.; Booij, K.; Greenwood, R. Modelling and field application of the Chemcatcher passive sampler calibration data for the monitoring of hydrophobic organic pollutants in water. Environ. Pollut. 2007, 145, 895-904.
-
(2007)
Environ. Pollut.
, vol.145
, pp. 895-904
-
-
Vrana, B.1
Mills, G.A.2
Kotterman, M.3
Leonards, P.4
Booij, K.5
Modelling, G.R.6
-
21
-
-
0027066810
-
Passive water sampling via semipermeable membrane devices in concert with bivalves in the Sacramento /San Joachin River Delta
-
Prest, H. F.; Jarman, W. M.; Burns, S. A.; Weismuller, T.; Huckins, J. N. Passive water sampling via semipermeable membrane devices in concert with bivalves in the Sacramento /San Joachin River Delta. Chemosphere 1992, 25, 1811-1824.
-
(1992)
Chemosphere
, vol.25
, pp. 1811-1824
-
-
Prest, H.F.1
Jarman, W.M.2
Burns, S.A.3
Weismuller, T.4
Huckins, J.N.5
-
22
-
-
0034782536
-
The use of liquid chromatography-atmospheric pressure ionization-mass spectrometry in water analysis - Part II: Obstacles
-
DOI 10.1016/S0165-9936(01)00103-0, PII S0165993601001030
-
Reemtsma, T. The use of liquid chromatography-atmospheric pressure ionization-mass spectrometry in water analysis-Part II: obstacles. Trends Anal. Chem. 2001, 20 (10), 533-542. (Pubitemid 33000323)
-
(2001)
TrAC - Trends in Analytical Chemistry
, vol.20
, Issue.10
, pp. 533-542
-
-
Reemtsma, T.1
-
24
-
-
0037064210
-
Alternative calibration approaches to compensate the effect of co-extracted matrix components in liquid chromatography-electrospray ionisation tandem mass spectrometry analysis of pesticide residues in plant materials
-
DOI 10.1016/S0021-9673(02)01196-2, PII S0021967302011962
-
Zrostlikova, J.; Hajslova, J.; Poustka, J.; Begany, P. Alternative calibration approaches to compensate the effect of co-extracted matrix components in liquid chromatography-electrospray ionisation tandem mass spectrometry analysis of pesticide residues in plant materials. J. Chromatogr., A 2002, 973 (1-2), 13-26. (Pubitemid 35279200)
-
(2002)
Journal of Chromatography A
, vol.973
, Issue.1-2
, pp. 13-26
-
-
Zrostlikova, J.1
Hajslova, J.2
Poustka, J.3
Begany, P.4
-
25
-
-
26444432866
-
Comparing pharmaceutical and pesticide loads into a small Mediterranean river
-
DOI 10.1016/j.scitotenv.2005.01.036, PII S0048969705000483
-
Comoretto, L.; Chiron, S. Comparing pharmaceutical and pesticide loads into a small Mediterranean river. Sci. Total Environ. 2005, 349 (1-3), 201-210. (Pubitemid 41421076)
-
(2005)
Science of the Total Environment
, vol.349
, Issue.1-3
, pp. 201-210
-
-
Comoretto, L.1
Chiron, S.2
-
26
-
-
8444232111
-
Evaluation of three calibration methods to compensate matrix effects in environmental analysis with LC-ESI-MS
-
DOI 10.1007/s00216-003-2442-8
-
Stiiber, M.; Reemtsma, T. Evaluation of three calibration methods to compensate matrix effects in environmental analysis with LC-ESI-MS. Anal Bioanal Chem. 2004, 378 (4), 910-916. (Pubitemid 40890202)
-
(2004)
Analytical and Bioanalytical Chemistry
, vol.378
, Issue.4
, pp. 910-916
-
-
Stuber, M.1
Reemtsma, T.2
-
27
-
-
0037165809
-
Analysis of polar pesticides in rainwater in Denmark by liquid chromatography-tandem mass spectrometry
-
Bossi, R.; Vejrup, K. V.; Mogensen, B. B.; Asman, W. A. H. Analysis of polar pesticides in rainwater in Denmark by liquid chromatography-tandem mass spectrometry. J. Chromatogr., A2002, 957 (1), 27-36.
-
(2002)
J. Chromatogr., A
, vol.957
, Issue.1
, pp. 27-36
-
-
Bossi, R.1
Vejrup, K.V.2
Mogensen, B.B.3
Asman, W.A.H.4
-
28
-
-
46049112753
-
Calibration of the Chemcatcher passive sampler for monitoring selected polar and semi-polar pesticides in surface water
-
Gunold, R.; Schäfer, R. B.; Paschke, A.; Schüürmann, G.; Liess, M. Calibration of the Chemcatcher passive sampler for monitoring selected polar and semi-polar pesticides in surface water. Environ. Pollut. 2008, 155, 52-60.
-
(2008)
Environ. Pollut.
, vol.155
, pp. 52-60
-
-
Gunold, R.1
Schäfer, R.B.2
Paschke, A.3
Schüürmann, G.4
Liess, M.5
-
29
-
-
0036189409
-
Spiking of performance reference compounds in low density polyethylene and silicone passive water samplers
-
Booij, K.; Smedes, F.; van Weerlee, E. M. Spiking of performance reference compounds in low density polyethylene and silicone passive water samplers. Chemosphere 2002, 46(8), 1157-1161.
-
(2002)
Chemosphere
, vol.46
, Issue.8
, pp. 1157-1161
-
-
Booij, K.1
Smedes, F.2
Van Weerlee, E.M.3
-
31
-
-
0037841826
-
Determination of herbicides, including thermally labile phenylureas, by solid-phase microextraction and gas chromatography-mass spectrometry
-
DOI 10.1016/S0021-9673(03)00642-3
-
Carabias-Martfnez, R.; Garcia-Hermida, C.; Rodríguez-Gonzalo, E.; Soriano-Bravo, F. E.; Hernández-Méndez, J. Determination of herbicides, including thermally labile phenylureas, by solidphase microextraction and gas chromatography-mass spectrometry. J. Chromatogr., A 2003, 1002, 1-12. (Pubitemid 36694940)
-
(2003)
Journal of Chromatography A
, vol.1002
, Issue.1-2
, pp. 1-12
-
-
Carabias-Martinez, R.1
Garcia-Hermida, C.2
Rodriguez-Gonzalo, E.3
Soriano-Bravo, F.E.4
Hernandez-Mendez, J.5
|