1
-
-
0028044712
-
Syringe pumps for infusion of vasoactive drugs: Mechanical idiosyncrasies and recommended operating procedures
-
Rooke GA, Bowdle TA (1994) Syringe pumps for infusion of vasoactive drugs: mechanical idiosyncrasies and recommended operating procedures. Anesth Analg 78:150-156
-
(1994)
Anesth Analg
, vol.78
, pp. 150-156
-
-
Rooke, G.A.1
Bowdle, T.A.2
-
2
-
-
0030695421
-
Design flaw can convert commercially available continuous syringe pumps to intermittent bolus injectors
-
Lonnqvist PA, Lofqvist B (1997) Design flaw can convert commercially available continuous syringe pumps to intermittent bolus injectors. Intensive Care Med 23:998-1001
-
(1997)
Intensive Care Med
, vol.23
, pp. 998-1001
-
-
Lonnqvist, P.A.1
Lofqvist, B.2
-
3
-
-
0034991140
-
Downward movement of syringe pumps reduces syringe output
-
Kern H, Kuring A, Redlich U, Dopfmer UR, Sims NM, Spies CD, Kox WJ (2001) Downward movement of syringe pumps reduces syringe output. Br J Anaesth 86:828-831
-
(2001)
Br J Anaesth
, vol.86
, pp. 828-831
-
-
Kern, H.1
Kuring, A.2
Redlich, U.3
Dopfmer, U.R.4
Sims, N.M.5
Spies, C.D.6
Kox, W.J.7
-
4
-
-
0035926043
-
Evaluation of the FASTSTART mode for reducing startup delay in syringe pump infusion systems
-
Neff T, Fischer J, Fehr S, Baenziger O, Weiss M (2001) Evaluation of the FASTSTART mode for reducing startup delay in syringe pump infusion systems. Swiss Med Wkly 131:219-222
-
(2001)
Swiss Med Wkly
, vol.131
, pp. 219-222
-
-
Neff, T.1
Fischer, J.2
Fehr, S.3
Baenziger, O.4
Weiss, M.5
-
5
-
-
0035723595
-
Start-up delays of infusion syringe pumps
-
Neff T, Fischer J, Fehr S, Baenziger O, Weiss M (2001) Start-up delays of infusion syringe pumps. Paediatr Anaesth 11:561-565
-
(2001)
Paediatr Anaesth
, vol.11
, pp. 561-565
-
-
Neff, T.1
Fischer, J.2
Fehr, S.3
Baenziger, O.4
Weiss, M.5
-
6
-
-
0033692930
-
The effects of syringe plunger design on drug delivery during vertical displacement of syringe pumps
-
Weiss M, Fischer J, Neff T, Baenziger O (2000) The effects of syringe plunger design on drug delivery during vertical displacement of syringe pumps. Anaesthesia 55:1094-1098
-
(2000)
Anaesthesia
, vol.55
, pp. 1094-1098
-
-
Weiss, M.1
Fischer, J.2
Neff, T.3
Baenziger, O.4
-
7
-
-
0035089356
-
Infusion pump performance with vertical displacement: Effect of syringe pump and assembly type
-
Neff TA, Fischer JE, Schulz G, Baenziger O, Weiss M (2001) Infusion pump performance with vertical displacement: effect of syringe pump and assembly type. Intensive Care Med 27:287-291
-
(2001)
Intensive Care Med
, vol.27
, pp. 287-291
-
-
Neff, T.A.1
Fischer, J.E.2
Schulz, G.3
Baenziger, O.4
Weiss, M.5
-
8
-
-
0033936276
-
Influence of infusion line compliance on drug delivery rate during acute line loop formation
-
Weiss M, Baenziger O, Neff T, Fanconi S (2000) Influence of infusion line compliance on drug delivery rate during acute line loop formation. Intensive Care Med 26:776-779
-
(2000)
Intensive Care Med
, vol.26
, pp. 776-779
-
-
Weiss, M.1
Baenziger, O.2
Neff, T.3
Fanconi, S.4
-
9
-
-
0033735621
-
Syringe size and flow rate affect drug delivery from syringe pumps
-
Weiss M, Hug MI, Neff T, Fischer J (2000) Syringe size and flow rate affect drug delivery from syringe pumps. Can J Anesth 47:1031-1035
-
(2000)
Can J Anesth
, vol.47
, pp. 1031-1035
-
-
Weiss, M.1
Hug, M.I.2
Neff, T.3
Fischer, J.4
-
10
-
-
0033751074
-
Syringe pump assemblies and the natural history of clinical technology
-
Cook RI (2000) Syringe pump assemblies and the natural history of clinical technology. Can J Anesth 47:929-935
-
(2000)
Can J Anesth
, vol.47
, pp. 929-935
-
-
Cook, R.I.1
-
11
-
-
0023202060
-
A gravimetric technique for evaluating flow continuity from two infusion devices
-
Leff RD, True WR, Roberts RJ (1987) A gravimetric technique for evaluating flow continuity from two infusion devices. Am J Hosp Pharm 44:1388-1391
-
(1987)
Am J Hosp Pharm
, vol.44
, pp. 1388-1391
-
-
Leff, R.D.1
True, W.R.2
Roberts, R.J.3
-
12
-
-
0030777861
-
Bacterial colonization and endotoxin contamination of intravenous fluids
-
Trautmann M, Zauser B, Wiedeck H, Buutenschön K, Marre R (2001) Bacterial colonization and endotoxin contamination of intravenous fluids. J Hosp Infect 37:225-236
-
(2001)
J Hosp Infect
, vol.37
, pp. 225-236
-
-
Trautmann, M.1
Zauser, B.2
Wiedeck, H.3
Buutenschön, K.4
Marre, R.5
-
13
-
-
77951207303
-
Analysis of particulate contaminations of infusion solutions in a pediatric intensive care unit
-
Jack T, Brent BE, Boehne M, Mü ller M, Sewald K, Braun A, Wessel A, Sasse M (2010) Analysis of particulate contaminations of infusion solutions in a pediatric intensive care unit. Intensive Care Med 36:707-711
-
(2010)
Intensive Care Med
, vol.36
, pp. 707-711
-
-
Jack, T.1
Brent, B.E.2
Boehne, M.3
Mü Ller, M.4
Sewald, K.5
Braun, A.6
Wessel, A.7
Sasse, M.8
-
14
-
-
0007530109
-
In-line intravenous filtration in neonates: Help not hindrance
-
Kunac DL, Ball PA, Broadbet RS (1999) In-line intravenous filtration in neonates: help not hindrance. Aust J Hosp Pharm 29:321-327
-
(1999)
Aust J Hosp Pharm
, vol.29
, pp. 321-327
-
-
Kunac, D.L.1
Ball, P.A.2
Broadbet, R.S.3
-
15
-
-
85047693818
-
Intravenous in-line filters: Filtering the evidence
-
Ball PA (2003) Intravenous in-line filters: filtering the evidence. Curr Opin Clin Nutr Metab Care 6:319-325
-
(2003)
Curr Opin Clin Nutr Metab Care
, vol.6
, pp. 319-325
-
-
Ball, P.A.1
|