Volumn 38, Issue 3, 2012, Pages 518-522

In-line filter included into the syringe infusion pump assembly reduces flow irregularities

Author keywords

Compliance; Complications; Equipment; In line filter; Infusion pump; Syringe

Indexed keywords

SHORT ACTING DRUG;

EID: 84862510947     PISSN: 03424642     EISSN: 14321238     Source Type: Journal    
DOI: 10.1007/s00134-011-2452-5     Document Type: Article
Times cited : (11)

References (15)
  • 1
    • 0028044712 scopus 로고
    • Syringe pumps for infusion of vasoactive drugs: Mechanical idiosyncrasies and recommended operating procedures
    • Rooke GA, Bowdle TA (1994) Syringe pumps for infusion of vasoactive drugs: mechanical idiosyncrasies and recommended operating procedures. Anesth Analg 78:150-156
    • (1994) Anesth Analg , vol.78 , pp. 150-156
    • Rooke, G.A.1    Bowdle, T.A.2
  • 2
    • 0030695421 scopus 로고    scopus 로고
    • Design flaw can convert commercially available continuous syringe pumps to intermittent bolus injectors
    • Lonnqvist PA, Lofqvist B (1997) Design flaw can convert commercially available continuous syringe pumps to intermittent bolus injectors. Intensive Care Med 23:998-1001
    • (1997) Intensive Care Med , vol.23 , pp. 998-1001
    • Lonnqvist, P.A.1    Lofqvist, B.2
  • 4
    • 0035926043 scopus 로고    scopus 로고
    • Evaluation of the FASTSTART mode for reducing startup delay in syringe pump infusion systems
    • Neff T, Fischer J, Fehr S, Baenziger O, Weiss M (2001) Evaluation of the FASTSTART mode for reducing startup delay in syringe pump infusion systems. Swiss Med Wkly 131:219-222
    • (2001) Swiss Med Wkly , vol.131 , pp. 219-222
    • Neff, T.1    Fischer, J.2    Fehr, S.3    Baenziger, O.4    Weiss, M.5
  • 6
    • 0033692930 scopus 로고    scopus 로고
    • The effects of syringe plunger design on drug delivery during vertical displacement of syringe pumps
    • Weiss M, Fischer J, Neff T, Baenziger O (2000) The effects of syringe plunger design on drug delivery during vertical displacement of syringe pumps. Anaesthesia 55:1094-1098
    • (2000) Anaesthesia , vol.55 , pp. 1094-1098
    • Weiss, M.1    Fischer, J.2    Neff, T.3    Baenziger, O.4
  • 7
    • 0035089356 scopus 로고    scopus 로고
    • Infusion pump performance with vertical displacement: Effect of syringe pump and assembly type
    • Neff TA, Fischer JE, Schulz G, Baenziger O, Weiss M (2001) Infusion pump performance with vertical displacement: effect of syringe pump and assembly type. Intensive Care Med 27:287-291
    • (2001) Intensive Care Med , vol.27 , pp. 287-291
    • Neff, T.A.1    Fischer, J.E.2    Schulz, G.3    Baenziger, O.4    Weiss, M.5
  • 8
    • 0033936276 scopus 로고    scopus 로고
    • Influence of infusion line compliance on drug delivery rate during acute line loop formation
    • Weiss M, Baenziger O, Neff T, Fanconi S (2000) Influence of infusion line compliance on drug delivery rate during acute line loop formation. Intensive Care Med 26:776-779
    • (2000) Intensive Care Med , vol.26 , pp. 776-779
    • Weiss, M.1    Baenziger, O.2    Neff, T.3    Fanconi, S.4
  • 9
    • 0033735621 scopus 로고    scopus 로고
    • Syringe size and flow rate affect drug delivery from syringe pumps
    • Weiss M, Hug MI, Neff T, Fischer J (2000) Syringe size and flow rate affect drug delivery from syringe pumps. Can J Anesth 47:1031-1035
    • (2000) Can J Anesth , vol.47 , pp. 1031-1035
    • Weiss, M.1    Hug, M.I.2    Neff, T.3    Fischer, J.4
  • 10
    • 0033751074 scopus 로고    scopus 로고
    • Syringe pump assemblies and the natural history of clinical technology
    • Cook RI (2000) Syringe pump assemblies and the natural history of clinical technology. Can J Anesth 47:929-935
    • (2000) Can J Anesth , vol.47 , pp. 929-935
    • Cook, R.I.1
  • 11
    • 0023202060 scopus 로고
    • A gravimetric technique for evaluating flow continuity from two infusion devices
    • Leff RD, True WR, Roberts RJ (1987) A gravimetric technique for evaluating flow continuity from two infusion devices. Am J Hosp Pharm 44:1388-1391
    • (1987) Am J Hosp Pharm , vol.44 , pp. 1388-1391
    • Leff, R.D.1    True, W.R.2    Roberts, R.J.3
  • 14
    • 0007530109 scopus 로고    scopus 로고
    • In-line intravenous filtration in neonates: Help not hindrance
    • Kunac DL, Ball PA, Broadbet RS (1999) In-line intravenous filtration in neonates: help not hindrance. Aust J Hosp Pharm 29:321-327
    • (1999) Aust J Hosp Pharm , vol.29 , pp. 321-327
    • Kunac, D.L.1    Ball, P.A.2    Broadbet, R.S.3
  • 15
    • 85047693818 scopus 로고    scopus 로고
    • Intravenous in-line filters: Filtering the evidence
    • Ball PA (2003) Intravenous in-line filters: filtering the evidence. Curr Opin Clin Nutr Metab Care 6:319-325
    • (2003) Curr Opin Clin Nutr Metab Care , vol.6 , pp. 319-325
    • Ball, P.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.