메뉴 건너뛰기




Volumn , Issue , 2011, Pages 5943-5946

Evaluation of the grading performance of an ensemble-based microaneurysm detector

Author keywords

[No Author keywords available]

Indexed keywords

DIABETIC RETINOPATHY SCREENING; MICROANEURYSMS; RESEARCH GROUPS;

EID: 84862285047     PISSN: 1557170X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2011.6091469     Document Type: Conference Paper
Times cited : (8)

References (17)
  • 1
    • 77949389021 scopus 로고    scopus 로고
    • Automated early detection of diabetic retinopathy
    • M. Abramoff, et al., "Automated early detection of diabetic retinopathy," Ophthalmology, vol. 117, no. 6, pp. 1147-1154, 2010.
    • (2010) Ophthalmology , vol.117 , Issue.6 , pp. 1147-1154
    • Abramoff, M.1
  • 2
    • 73849110207 scopus 로고    scopus 로고
    • Retinopathy online challenge: Automatic detection of microaneurysms in digital color fundus photographs
    • M. Niemeijer, et al., "Retinopathy online challenge: Automatic detection of microaneurysms in digital color fundus photographs," IEEE Transactions on Medical Imaging, vol. 29, no. 1, pp. 185-195, 2010.
    • (2010) IEEE Transactions on Medical Imaging , vol.29 , Issue.1 , pp. 185-195
    • Niemeijer, M.1
  • 3
    • 84863787208 scopus 로고    scopus 로고
    • Improving microaneurysm detection in color fundus images by using an optimal combination of preprocessing methods and candidate extractors
    • B.Antal et al., "Improving microaneurysm detection in color fundus images by using an optimal combination of preprocessing methods and candidate extractors," 18th EUSIPCO, pp. 1224-1228, 2010.
    • (2010) 18th EUSIPCO , pp. 1224-1228
    • Antal, B.1
  • 4
    • 84974658575 scopus 로고    scopus 로고
    • Automatic detection of microaneyrysms in color fundus images of the human retina by means of the bounding box closing
    • T. Walter et al., "Automatic detection of microaneyrysms in color fundus images of the human retina by means of the bounding box closing," Lecture Notes in Computer Science, vol. 2526, pp. 210-220, 2002.
    • (2002) Lecture Notes in Computer Science , vol.2526 , pp. 210-220
    • Walter, T.1
  • 5
    • 0012934579 scopus 로고
    • Contrast limited adaptive histogram equalization
    • K. Zuiderveld, "Contrast limited adaptive histogram equalization," Graphics gems, vol. IV, pp. 474-485, 1994.
    • (1994) Graphics Gems , vol.4 , pp. 474-485
    • Zuiderveld, K.1
  • 6
    • 70450203631 scopus 로고    scopus 로고
    • Automated feature extraction for early detection of diabetic retinopathy in fundus images
    • S. Ravishankar, et al., "Automated feature extraction for early detection of diabetic retinopathy in fundus images," in Computer Vision and Pattern Recognition, 2009, pp. 210-217.
    • (2009) Computer Vision and Pattern Recognition , pp. 210-217
    • Ravishankar, S.1
  • 7
    • 0041438527 scopus 로고    scopus 로고
    • Object removal by exemplar-based inpainting
    • A. Criminisi, et al., "Object removal by exemplar-based inpainting," in Computer Vision and Pattern Recognition, vol. 2, 2003, pp. II-721- II-728.
    • (2003) Computer Vision and Pattern Recognition , vol.2
    • Criminisi, A.1
  • 8
    • 0041525298 scopus 로고    scopus 로고
    • Locating the optic nerve in a retinal image using the fuzzy convergence of the blood vessels
    • A. Hoover et al., "Locating the optic nerve in a retinal image using the fuzzy convergence of the blood vessels," IEEE Transactions on Medical Imaging, vol. 22, no. 8, pp. 951 -958, 2003.
    • (2003) IEEE Transactions on Medical Imaging , vol.22 , Issue.8 , pp. 951-958
    • Hoover, A.1
  • 9
    • 35548936172 scopus 로고    scopus 로고
    • Automatic detection of microaneurysms in color fundus images
    • T. Walter, et al., "Automatic detection of microaneurysms in color fundus images," Medical Image Analysis, vol. 11, pp. 555-566, 2007.
    • (2007) Medical Image Analysis , vol.11 , pp. 555-566
    • Walter, T.1
  • 10
    • 0042262446 scopus 로고    scopus 로고
    • An image-processing strategy for the segmentation and quantification of microaneurysms in fluorescein angiograms of the ocular fundus
    • May
    • T. Spencer, et al., "An image-processing strategy for the segmentation and quantification of microaneurysms in fluorescein angiograms of the ocular fundus," Computers and Biomedical Research, vol. 29, pp. 284-302, May 1996.
    • (1996) Computers and Biomedical Research , vol.29 , pp. 284-302
    • Spencer, T.1
  • 13
    • 76749116112 scopus 로고    scopus 로고
    • Detection of microaneurysms using multi-scale correlation coefficients
    • B. Zhang, et al., "Detection of microaneurysms using multi-scale correlation coefficients," Pattern Recogn., vol. 43, no. 6, pp. 2237-2248, 2010.
    • (2010) Pattern Recogn. , vol.43 , Issue.6 , pp. 2237-2248
    • Zhang, B.1
  • 14
    • 26444479778 scopus 로고
    • Optimization by simulated annealing
    • S. Kirkpatrick, et al., "Optimization by simulated annealing," Science, vol. 220, pp. 671-680, 1983.
    • (1983) Science , vol.220 , pp. 671-680
    • Kirkpatrick, S.1
  • 15
    • 84055202486 scopus 로고    scopus 로고
    • On combining computer-aided detection systems
    • M. Niemeijer, et al., "On combining computer-aided detection systems," IEEE Transactions on Medical Imaging, vol. PP, no. 99, pp. 1-1, 2010.
    • (2010) IEEE Transactions on Medical Imaging , Issue.99 , pp. 1-1
    • Niemeijer, M.1
  • 17
    • 38949216071 scopus 로고    scopus 로고
    • Evaluation of a system for automatic detection of diabetic retinopathy from color fundus photographs in a large population of patients with diabetes
    • February
    • M. Abramoff, et al., "Evaluation of a system for automatic detection of diabetic retinopathy from color fundus photographs in a large population of patients with diabetes," Diabetes Care, vol. 31, pp. 193-198, February 2008.
    • (2008) Diabetes Care , vol.31 , pp. 193-198
    • Abramoff, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.