Micro-aneurysm detection using vessels removal and circular Hough transform

Author keywords

[No Author keywords available]

Indexed keywords

DIAGNOSIS; EYE PROTECTION; HOUGH TRANSFORMS; IMAGE PROCESSING; OPHTHALMOLOGY;

EID: 32244434239     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NRSC.2002.1022650     Document Type: Conference Paper
Times cited : (44)

References (12)
  • 2
    • 0024793671 scopus 로고
    • The relationship of retinal microaneurysm counts to the 4-year pogression of diabetic retinopathy
    • R. Klein, S. M. Meuer, S. E. Moss, and B. E. Klein, "The relationship of retinal microaneurysm counts to the 4-year pogression of diabetic retinopathy," Arch. Ophthal., vol. 107, pp. 1780-1785,1986.
    • (1986) Arch. Ophthal. , vol.107 , pp. 1780-1785
    • Klein, R.1    Meuer, S.M.2    Moss, S.E.3    Klein, B.E.4
  • 5
    • 0042262446 scopus 로고    scopus 로고
    • An image processing strategy for the segmentation and quantification of microaneurysms in fluorescein angiograms of the ocular fundus
    • T. Spencer, J. A. Olson, K.C. McHardy, P.F. Sharp, and J. V. Forrester, "An image processing strategy for the segmentation and quantification of microaneurysms in fluorescein angiograms of the ocular fundus," Computers and Biomedical Research, vol. 29, pp. 284-302, 1996.
    • (1996) Computers and Biomedical Research , vol.29 , pp. 284-302
    • Spencer, T.1    Olson, J.A.2    McHardy, K.C.3    Sharp, P.F.4    Forrester, J.V.5
  • 7
    • 84952871665 scopus 로고    scopus 로고
    • Using circular Hough transform for detecting microaneurysms in fluorescein angiograms of the ocular fundus
    • 19-21 December 2001, Cairo.
    • S. Abelazeem, M. Hafez, and G. Auda, "Using circular Hough transform for detecting microaneurysms in fluorescein angiograms of the ocular fundus," International Conference on Industrial Electronics, 19-21 December 2001, Cairo. 2001.
    • (2001) International Conference on Industrial Electronics
    • Abelazeem, S.1    Hafez, M.2    Auda, G.3
  • 8
    • 0015285440 scopus 로고
    • Using the Hough transform to detect lines and curves in pictures
    • R.O. Duda and P.E. Hart, "Using the Hough transform to detect lines and curves in pictures," Comm. Of the ACM, vol. 15, pp. 11-15, 1972.
    • (1972) Comm. of the ACM , vol.15 , pp. 11-15
    • Duda, R.O.1    Hart, P.E.2
  • 9
    • 0024734454 scopus 로고
    • Detection of blood vessels in retinal images using two-dimensional matched filters
    • Sept.
    • S. Chaudhuri, S. Chatterjee, N. Katz, M. Nelson, and M. Goldbaum, "Detection of blood vessels in retinal images using two-dimensional matched filters," IEEE Trans. On Medical Imaging, vol. 8, pp. 263-269, Sept. 1989.
    • (1989) IEEE Trans. on Medical Imaging , vol.8 , pp. 263-269
    • Chaudhuri, S.1    Chatterjee, S.2    Katz, N.3    Nelson, M.4    Goldbaum, M.5
  • 11
    • 0032034235 scopus 로고    scopus 로고
    • A fuzzy vessel tracking algorithm for retinal images based on fuzzy clustering
    • April
    • Y. A. Tolias and S. M. Panas, "A fuzzy vessel tracking algorithm for retinal images based on fuzzy clustering," IEEE Trans. On Medical Imaging, vol. 17, pp. 263-273, April 1998.
    • (1998) IEEE Trans. on Medical Imaging , vol.17 , pp. 263-273
    • Tolias, Y.A.1    Panas, S.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.