메뉴 건너뛰기




Volumn 37, Issue 2, 1997, Pages 260-267

Angiographic imaging with 2D RF pulses

Author keywords

magnetic resonance angiography; multi dimensional selective excitation; RF pulse design; small field of view imaging

Indexed keywords

ANGIOGRAPHY; SPACE FLIGHT;

EID: 0031013124     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.1910370220     Document Type: Article
Times cited : (47)

References (15)
  • 1
    • 0025004208 scopus 로고
    • Time-of-flight effects in MR imaging of flow
    • F. W. Wehrli, Time-of-flight effects in MR imaging of flow. Magn. Reson. Med. 14, 187-193 (1990).
    • (1990) Magn. Reson. Med. , vol.14 , pp. 187-193
    • Wehrli, F.W.1
  • 2
    • 0023203564 scopus 로고
    • MR vascular imaging with a fast gradient refocusing pulse sequence and reformatted images from transaxial sections
    • G. T. Gullberg, F. W. Wehrli, A. Shimakawa, M. Simons, MR vascular imaging with a fast gradient refocusing pulse sequence and reformatted images from transaxial sections. Radiology 165, 241-246 (1987).
    • (1987) Radiology , vol.165 , pp. 241-246
    • Gullberg, G.T.1    Wehrli, F.W.2    Shimakawa, A.3    Simons, M.4
  • 3
    • 0020340302 scopus 로고
    • A flow velocity zeugmatographic interlace for NMR imaging in humans
    • P. R. Moran, A flow velocity zeugmatographic interlace for NMR imaging in humans. Magn. Reson. Imaging 1, 197-203 (1982).
    • (1982) Magn. Reson. Imaging , vol.1 , pp. 197-203
    • Moran, P.R.1
  • 5
    • 0347361501 scopus 로고
    • Two-dimensional spatially selective spin inversion and spin-echo refocusing with a single nuclear magnetic resonance pulse
    • P. A. Bottomley, C. J. Hardy, Two-dimensional spatially selective spin inversion and spin-echo refocusing with a single nuclear magnetic resonance pulse. J. Appl. Phys. 62, 4284-4290 (1987).
    • (1987) J. Appl. Phys. , vol.62 , pp. 4284-4290
    • Bottomley, P.A.1    Hardy, C.J.2
  • 6
    • 8044224452 scopus 로고
    • Excitation of a 1-mm-diameter beam with response modulated excitation
    • Abstract 228
    • T. J. Wieczorek, J. D. Pearlman, Excitation of a 1-mm-diameter beam with response modulated excitation. J. Magn. Reson. Imaging 4(P) 62 (1994). [Abstract 228].
    • (1994) J. Magn. Reson. Imaging , vol.4 , Issue.P , pp. 62
    • Wieczorek, T.J.1    Pearlman, J.D.2
  • 7
    • 0028030442 scopus 로고
    • 2-corrected technique achieving specified magnetization patterns from an RF pulse and time-varying magnetic field
    • 2-corrected technique achieving specified magnetization patterns from an RF pulse and time-varying magnetic field. Magn. Reson. Med. 32, 388-395 (1994).
    • (1994) Magn. Reson. Med. , vol.32 , pp. 388-395
    • Pearlman, J.D.1    Wieczorek, T.J.2
  • 8
    • 0027502847 scopus 로고
    • Phase velocity mapping with a real time line scan technique
    • K. Butts, N. J. Hangiandreou, S. J. Riederer, Phase velocity mapping with a real time line scan technique. Magn. Reson. Med. 29, 134-138 (1993).
    • (1993) Magn. Reson. Med. , vol.29 , pp. 134-138
    • Butts, K.1    Hangiandreou, N.J.2    Riederer, S.J.3
  • 11
    • 45149145242 scopus 로고
    • A k-space analysis of small-tip-angle excitation
    • J. Pauly, D. Nishimura, A. Macovski, A k-space analysis of small-tip-angle excitation. J. Magn. Reson. 81, 43-56 (1989).
    • (1989) J. Magn. Reson. , vol.81 , pp. 43-56
    • Pauly, J.1    Nishimura, D.2    Macovski, A.3
  • 12
    • 0000768763 scopus 로고
    • A linear class of large-tip-angle selective excitation pulses
    • J. Pauly, D. Nishimura, A. Macovski, A linear class of large-tip-angle selective excitation pulses. J. Magn. Reson. 82, 571-587 (1989).
    • (1989) J. Magn. Reson. , vol.82 , pp. 571-587
    • Pauly, J.1    Nishimura, D.2    Macovski, A.3
  • 13
    • 0025298010 scopus 로고
    • 2 limitations and off-resonance effects on spatial resolution and artifacts in echo-planar imaging
    • 2 limitations and off-resonance effects on spatial resolution and artifacts in echo-planar imaging. Magn. Rason. Med. 14, 123-139 (1990).
    • (1990) Magn. Rason. Med. , vol.14 , pp. 123-139
    • Farzaneh, F.1    Riederer, S.J.2    Pelc, N.J.3
  • 14
    • 0026856564 scopus 로고
    • Analysis of flow effects in echo-planar imaging
    • K. Butts, S. J. Riederer, Analysis of flow effects in echo-planar imaging. J. Magn. Reson. Imaging 2, 285-293 (1992).
    • (1992) J. Magn. Reson. Imaging , vol.2 , pp. 285-293
    • Butts, K.1    Riederer, S.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.