Volumn 56, Issue 6, 2012, Pages 730-737

Agreement between cardiac outputs by four-dimensional echocardiography and thermodilution method is poor

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; CLINICAL ARTICLE; CORONARY ARTERY BYPASS GRAFT; ELECTIVE SURGERY; FEMALE; FOUR DIMENSIONAL ECHOCARDIOGRAPHY; HEART OUTPUT; HEART RATE VARIABILITY; HUMAN; IMAGE QUALITY; INTERMETHOD COMPARISON; MALE; PRIORITY JOURNAL; PULMONARY ARTERY CATHETER; THERMODILUTION;

EID: 84862175950     PISSN: 00015172     EISSN: 13996576     Source Type: Journal    
DOI: 10.1111/j.1399-6576.2012.02655.x     Document Type: Article
Times cited : (6)

References (35)
  • 3
    • 0031034151 scopus 로고    scopus 로고
    • Intensive care physicians' insufficient knowledge of right-heart catheterization at the bedside: Time to act?
    • DOI 10.1097/00003246-199702000-00003
    • Gnaegi A, Feihl F, Perret C,. Intensive care physicians' insufficient knowledge of right-heart catheterization at the bedside: time to act? Crit Care Med 1997; 25: 213-220. (Pubitemid 27086052)
    • (1997) Critical Care Medicine , vol.25 , Issue.2 , pp. 213-220
    • Gnaegi, A.1    Feihl, F.2    Perret, C.3
  • 6
    • 29644445829 scopus 로고    scopus 로고
    • Role of real time 3D echocardiography in evaluating the left ventricle
    • DOI 10.1136/hrt.2004.058388
    • Monaghan MJ,. Role of real time 3D echocardiography in evaluating the left ventricle. Heart 2006; 92: 131-136. (Pubitemid 43021881)
    • (2006) Heart , vol.92 , Issue.1 , pp. 131-136
    • Monaghan, M.J.1
  • 7
    • 41149156955 scopus 로고    scopus 로고
    • Feasibility and clinical decision-making with 3D echocardiography in routine practice
    • DOI 10.1136/hrt.2007.123570
    • Hare JL, Jenkins C, Nakatani S, Ogawa A, Yu C, Marwick TH,. Feasibility and clinical decision-making with 3D echocardiography in routine practice. Heart 2008; 94: 440-445. (Pubitemid 351441397)
    • (2008) Heart , vol.94 , Issue.4 , pp. 440-445
    • Hare, J.L.1    Jenkins, C.2    Nakatani, S.3    Ogawa, A.4    Yu, C.-M.5    Marwick, T.H.6
  • 8
    • 14744296915 scopus 로고    scopus 로고
    • Comparison of left ventricular volumes and ejection fractions measured by three-dimensional echocardiography versus by two-dimensional echocardiography and cardiac magnetic resonance in patients with various cardiomyopathies
    • DOI 10.1016/j.amjcard.2004.11.046
    • Gutiérrez-Chico J, Zamorano JL, Isla LPD, Orejas M, Almeíra C, Rodrigo JL, Ferreirõs J, Serra V, Macaya C,. Comparison of left ventricular volumes and ejection fractions measured by three-dimensional echocardiography versus two-dimensional echocardiography and cardiac magnetic resonance in patients with various cardiomyopathies. Am J Cardiol 2005; 95: 809-813. (Pubitemid 40332671)
    • (2005) American Journal of Cardiology , vol.95 , Issue.6 , pp. 809-813
    • Gutierrez-Chico, J.L.1    Zamorano, J.L.2    Perez De Isla, L.3    Orejas, M.4    Almeria, C.5    Rodrigo, J.L.6    Ferreiros, J.7    Serra, V.8    Macaya, C.9
  • 9
    • 4143108001 scopus 로고    scopus 로고
    • Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiography
    • DOI 10.1016/j.jacc.2004.05.050, PII S0735109704011179
    • Jenkins C, Bricknell K, Hanekom L, Marwick TH,. Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiography. J Am Coll Cardiol 2004; 44: 878-886. (Pubitemid 39099588)
    • (2004) Journal of the American College of Cardiology , vol.44 , Issue.4 , pp. 878-886
    • Jenkins, C.1    Bricknell, K.2    Hanekom, L.3    Marwick, T.H.4
  • 12
    • 33747431187 scopus 로고    scopus 로고
    • Quantitative assessment of left ventricular size and function: Side-by-side comparison of real-time three-dimensional echocardiography and computed tomography with magnetic resonance reference
    • DOI 10.1161/CIRCULATIONAHA.106.626143, PII 0000301720060815000009
    • Sugeng L, Mor-Avi V, Weinert L, Niel J, Ebner C, Steringer-Mascherbauer R, Schmidt F, Galuschky C, Schummers G, Lang RM, Nesser HJ,. Quantitative assessment of left ventricular size and function. Side-by-side comparison of real-time three-dimensional echocardiography and computed tomography width magnetic resonance reference. Circulation 2006; 114: 654-661. (Pubitemid 44252307)
    • (2006) Circulation , vol.114 , Issue.7 , pp. 654-661
    • Sugeng, L.1    Mor-Avi, V.2    Weinert, L.3    Niel, J.4    Ebner, C.5    Steringer-Mascherbauer, R.6    Schmidt, F.7    Galuschky, C.8    Schummers, G.9    Lang, R.M.10    Nesser, H.-J.11
  • 13
    • 65549090143 scopus 로고    scopus 로고
    • Semi-automated quantification of left ventricular volumes and ejection fraction by real-time three-dimensional echocardiography
    • Hansegård J, Urheim S, Lunde K, Malm S, Rabben SI,. Semi-automated quantification of left ventricular volumes and ejection fraction by real-time three-dimensional echocardiography. Cardiovasc Ultrasound 2009; 7: 18.
    • (2009) Cardiovasc Ultrasound , vol.7 , pp. 18
    • Hansegård, J.1    Urheim, S.2    Lunde, K.3    Malm, S.4    Rabben, S.I.5
  • 14
    • 0028961244 scopus 로고
    • Continuous cardiac output measurements in the perioperative period
    • Jakobsen C-J, Melsen NC, Andresen EB,. Continuous cardiac output measurements in the perioperative period. Acta Anaesthesiol Scand 1995; 39: 485-488.
    • (1995) Acta Anaesthesiol Scand , vol.39 , pp. 485-488
    • Jakobsen, C.-J.1    Melsen, N.C.2    Andresen, E.B.3
  • 15
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • Bland JM, Altman DG,. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 8476: 307-310. (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 16
    • 78650833522 scopus 로고    scopus 로고
    • Cardiac output monitoring: Is there a gold standard and how do the newer technologies compare?
    • Pugsley J, Lerner AB,. Cardiac output monitoring: is there a gold standard and how do the newer technologies compare? Semin Cardiothorac Vasc Anesth 2010; 14: 274-282.
    • (2010) Semin Cardiothorac Vasc Anesth , vol.14 , pp. 274-282
    • Pugsley, J.1    Lerner, A.B.2
  • 17
    • 33847048638 scopus 로고    scopus 로고
    • Current practice of hemodynamic monitoring and vasopressor and inotropic therapy in post-operative cardiac surgery patients in Germany: Results from a postal survey
    • Kanstrup M, Markewitz A, Spies C, Carl M, Erb J, Grosse J, Schirmer U,. Current practice of hemodynamic monitoring and vasopressor and inotropic therapy in post-operative cardiac surgery patients in Germany: results from a postal survey. Acta Anaesthesiol Scand 2007; 51: 347-358.
    • (2007) Acta Anaesthesiol Scand , vol.51 , pp. 347-358
    • Kanstrup, M.1    Markewitz, A.2    Spies, C.3    Carl, M.4    Erb, J.5    Grosse, J.6    Schirmer, U.7
  • 18
    • 1942454804 scopus 로고    scopus 로고
    • Comparison of Esophageal Doppler, Pulse Contour Analysis, and Real-Time Pulmonary Artery Thermodilution for the Continuous Measurement of Cardiac Output
    • DOI 10.1053/j.jvca.2004.01.025
    • Bein B, Worthmann F, Tonner PH, Paris A, Steinfath M, Hedderich J, Scholz J,. Comparison of esophageal Doppler, pulse contour analysis, and real-time pulmonary artery thermodilution for the continuous measurement of cardiac output. J Cardiothorac Vasc Anesth 2004; 18: 185-189. (Pubitemid 38506866)
    • (2004) Journal of Cardiothoracic and Vascular Anesthesia , vol.18 , Issue.2 , pp. 185-189
    • Bein, B.1    Worthmann, F.2    Tonner, P.H.3    Paris, A.4    Steinfath, M.5    Hedderich, J.6    Scholz, J.7
  • 19
    • 0029992651 scopus 로고    scopus 로고
    • Delayed time response of the continuous cardiac output pulmonary artery catheter
    • Siegel LC, Hennessy MM, Pearl RG,. Delayed time response of the continuous cardiac output pulmonary artery catheter. Anesth Analg 1996; 83: 1173-1177. (Pubitemid 26418799)
    • (1996) Anesthesia and Analgesia , vol.83 , Issue.6 , pp. 1173-1177
    • Siegel, L.C.1    Hennessy, M.M.2    Pearl, R.G.3
  • 20
    • 0032435617 scopus 로고    scopus 로고
    • Continuous cardiac output catheters: Delay in in vitro response time after controlled flow changes
    • DOI 10.1097/00000542-199812000-00047
    • Aranda M, Mihm FG, Garrett S, Mihm MN, Pearl RG,. Continuous cardiac output catheters: delay in in vitro response time after controlled flow changes. Anesthesiology 1998; 89: 1592-1595. (Pubitemid 29001608)
    • (1998) Anesthesiology , vol.89 , Issue.6 , pp. 1592-1595
    • Aranda, M.1    Mihm, F.G.2    Garrett, S.3    Mihm, M.N.4    Pearl, R.G.5
  • 22
    • 0025758339 scopus 로고
    • Stress echocardiography and the human factor: The importance of being expert
    • Picano E, Lattanzi F, Orlandini A, Marini C, Labbate A,. Stress echocardiography and the human factor: the importance of being expert. J Am Coll Cardiol 1991; 17: 666-669.
    • (1991) J Am Coll Cardiol , vol.17 , pp. 666-669
    • Picano, E.1    Lattanzi, F.2    Orlandini, A.3    Marini, C.4    Labbate, A.5
  • 23
    • 0020421192 scopus 로고
    • Dynamic three-dimensional echocardiographic reconstruction of the intact human left ventricle: Technique and initial observations in patients
    • Geiser EA, Ariet M, Conetta DA, Lupkiewicz SM, Christie LG, Conti CR,. Dynamic 3-dimensional echocardiographic reconstruction of the intact human left ventricle: technique and initial observations in patients. Am Heart J 1982; 103: 1056-1065. (Pubitemid 13137893)
    • (1982) American Heart Journal , vol.103 , Issue.6 , pp. 1056-1065
    • Geiser, E.A.1    Ariet, M.2    Conetta, D.A.3
  • 24
    • 0029775223 scopus 로고    scopus 로고
    • Left ventricular volume calculations using a multiplanar transoesophageal echoprobe; in vitro validation and comparison with biplane angiography
    • Krebs W, Klues HG, Steinert S, Sivarajan M, Job FP, Flachskampf FA, Franke A, Reineke T, Hanrath P,. Left ventricular volume calculations using a multiplanar transoesophageal echoprobe: in vitro validation and comparison with biplane angiography. Eur Heart J 1996; 17: 1279-1288. (Pubitemid 26289963)
    • (1996) European Heart Journal , vol.17 , Issue.8 , pp. 1279-1288
    • Krebs, W.1    Klues, H.G.2    Steinert, S.3    Sivarajan, M.4    Job, F.P.5    Flachskampf, F.A.6    Franke, A.7    Reineke, T.8    Hanrath, P.9
  • 25
    • 0030090116 scopus 로고    scopus 로고
    • Three-dimensional echocardiography: The influence of number of component images on accuracy of left ventricular volume quantitation
    • Siu SC, Rivera JM, Handschumacher MD, Weyman AE, Levine RA, Picard MH,. Three-dimensional echocardiography: the influence of number of component images on accuracy of left ventricular volume quantitation. J Am Soc Echocardiogr 1996; 9: 147-155.
    • (1996) J Am Soc Echocardiogr , vol.9 , pp. 147-155
    • Siu, S.C.1    Rivera, J.M.2    Handschumacher, M.D.3    Weyman, A.E.4    Levine, R.A.5    Picard, M.H.6
  • 27
    • 31944449586 scopus 로고    scopus 로고
    • What is the optimal clinical technique for measurement of left ventricular volume after myocardial infarction? A comparative study of 3-dimensional echocardiography, single photon emission computed tomography, and cardiac magnetic resonance imaging
    • DOI 10.1016/j.echo.2005.08.020, PII S089473170500787X
    • Chan J, Jenkins C, Khafagi F, Du L, Marwick TH,. What is the optimal clinical technique for measurement of left ventricular volume after myocardial infarction: a comparative study of 3-dimensional echocardiography, single photon emission computed tomography, and cardiac magnetic resonance imaging. J Am Soc Echocardiogr 2006; 19: 192-201. (Pubitemid 43187163)
    • (2006) Journal of the American Society of Echocardiography , vol.19 , Issue.2 , pp. 192-201
    • Chan, J.1    Jenkins, C.2    Khafagi, F.3    Du, L.4    Marwick, T.H.5
  • 28
    • 17144461250 scopus 로고    scopus 로고
    • High-resolution transthoracic real-time three-dimensional echocardiography: Quantitation of cardiac volumes and function using semi-automatic border detection and comparison with cardiac magnetic resonance imaging
    • DOI 10.1016/j.jacc.2004.01.037, PII S073510970400484X
    • Kühl HP, Schreckenberg M, Rulands D, Katoh M, Schäfer W, Schummers G, Bücker A, Hanrath P, Franke A,. High-resolution transthoracic real-time three-dimensional echocardiography: quantitation of cardiac volumes and function using semiautomatic border detection and comparison with cardiac magnetic resonance imaging. J Am Coll Cardiol 2004; 43: 2083-2090. (Pubitemid 38686806)
    • (2004) Journal of the American College of Cardiology , vol.43 , Issue.11 , pp. 2083-2090
    • Kuhl, H.P.1    Schreckenberg, M.2    Rulands, D.3    Katoh, M.4    Schafer, W.5    Schummers, G.6    Bucker, A.7    Hanrath, P.8    Franke, A.9
  • 29
    • 34748840861 scopus 로고    scopus 로고
    • A comparison between QLAB and tomtec full volume reconstruction for real time three-dimensional echocardiographic quantification of left ventricular volumes
    • DOI 10.1111/j.1540-8175.2007.00502.x
    • Soliman OI, Krenning BJ, Geleijnse ML, Nemes A, van, Geuns R, Baks T, Anwar AM, Galema TW, Vletter WB, Gate FJT,. A comparison between QLAB and TomTec full volume reconstruction for real time three-dimensional echocardiographic quantification of left ventricular volumes. Echocardiography 2007; 24: 967-974. (Pubitemid 47485652)
    • (2007) Echocardiography , vol.24 , Issue.9 , pp. 967-974
    • Soliman, O.I.I.1    Krenning, B.J.2    Geleijnse, M.L.3    Nemes, A.4    Van Geuns, R.-J.5    Baks, T.6    Anwar, A.M.7    Galema, T.W.8    Vletter, W.B.9    Cate, F.J.T.10
  • 30
    • 34247105479 scopus 로고    scopus 로고
    • The exactness of left ventricular segmentation in cine magnetic resonance imaging and its impact on systolic function values
    • DOI 10.1080/02841850601182154, PII 777231446
    • Barbier C, Johansson L, Lind L, Ahlström H, Bjerner T,. The exactness of left ventricular segmentation in cine magnetic resonance imaging and its impact on systolic function values. Acta Radiol 2007; 48: 285-291. (Pubitemid 46589081)
    • (2007) Acta Radiologica , vol.48 , Issue.3 , pp. 285-291
    • Barbier, C.E.1    Johansson, L.2    Lind, L.3    Ahlstrom, H.4    Bjerner, T.5
  • 31
    • 79956369482 scopus 로고    scopus 로고
    • Left atrial volume by real-time three-dimensional echocardiography: Validation by 64-slice multidetector computed tomography
    • Miyasaka Y, Tsujimoto S, Maeba H, Yuasa F, Takehana K, Dote K, Iwasaka T,. Left atrial volume by real-time three-dimensional echocardiography: validation by 64-slice multidetector computed tomography. J Am Soc Echocardiogr 2011; 24: 680-686.
    • (2011) J Am Soc Echocardiogr , vol.24 , pp. 680-686
    • Miyasaka, Y.1    Tsujimoto, S.2    Maeba, H.3    Yuasa, F.4    Takehana, K.5    Dote, K.6    Iwasaka, T.7
  • 33
    • 0034148858 scopus 로고    scopus 로고
    • Left and right atrial volume by freehand three-dimensional echocardiography: In vivo validation using magnetic resonance imaging
    • Keller AM, Gopal AS, King DL,. Left and right atrial volume by freehand three-dimensional echocardiography: in vivo validation using magnetic resonance imaging. Eur J Echocardiogr 2000; 1: 55-65.
    • (2000) Eur J Echocardiogr , vol.1 , pp. 55-65
    • Keller, A.M.1    Gopal, A.S.2    King, D.L.3
  • 34
    • 64649092670 scopus 로고    scopus 로고
    • Left atrial volume measurement with automated border detection by 3-dimensional echocardiography: Comparison with magnetic resonance imaging
    • Artang R, Migrino RQ, Harmann L, Bowers M, Woods TD,. Left atrial volume measurement with automated border detection by 3-dimensional echocardiography: comparison with magnetic resonance imaging. Cardiovasc Ultrasound 2009; 7: 16.
    • (2009) Cardiovasc Ultrasound , vol.7 , pp. 16
    • Artang, R.1    Migrino, R.Q.2    Harmann, L.3    Bowers, M.4    Woods, T.D.5
  • 35
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • DOI 10.1023/A:1009982611386
    • Critchley LA, Critchley JA,. A meta-analysis of studies using bias and precision statistics to compare CO measurement techniques. J Clin Monit Comput 1999; 15: 85-91. (Pubitemid 29278438)
    • (1999) Journal of Clinical Monitoring and Computing , vol.15 , Issue.2 , pp. 85-91
    • Critchley, L.A.H.1    Critchley, J.A.J.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.