메뉴 건너뛰기




Volumn 24, Issue 9, 2007, Pages 967-974

A comparison between QLAB and tomtec full volume reconstruction for real time three-dimensional echocardiographic quantification of left ventricular volumes

Author keywords

Echocardiography; Left ventricular function; RT3DE

Indexed keywords

ADULT; AGED; ARTICLE; CARDIOMYOPATHY; CLINICAL ARTICLE; COMPUTER PROGRAM; DIAGNOSTIC ACCURACY; DIASTOLE; FEMALE; HEART LEFT VENTRICLE EJECTION FRACTION; HEART LEFT VENTRICLE FUNCTION; HEART LEFT VENTRICLE VOLUME; HUMAN; INTERMETHOD COMPARISON; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; REAL TIME ECHOGRAPHY; REPRODUCIBILITY; SINUS RHYTHM; SYSTOLE; THREE DIMENSIONAL ECHOCARDIOGRAPHY; TWO DIMENSIONAL ECHOCARDIOGRAPHY;

EID: 34748840861     PISSN: 07422822     EISSN: 15408175     Source Type: Journal    
DOI: 10.1111/j.1540-8175.2007.00502.x     Document Type: Article
Times cited : (90)

References (19)
  • 1
    • 0041356972 scopus 로고    scopus 로고
    • Natural history of asymptomatic left ventricular systolic dysfunction in the community
    • Wang TJ, Evans JC, Benjamin EJ, et al : Natural history of asymptomatic left ventricular systolic dysfunction in the community. Circulation 2003 108 : 977 982.
    • (2003) Circulation , vol.108 , pp. 977-982
    • Wang, T.J.1    Evans, J.C.2    Benjamin, E.J.3
  • 2
    • 0027374244 scopus 로고
    • Three-dimensional echocardiography. in vivo validation for left ventricular volume and function
    • Siu SC, Rivera JM, Guerrero JL, et al : Three-dimensional echocardiography. In vivo validation for left ventricular volume and function. Circulation 1993 88 : 1715 1723.
    • (1993) Circulation , vol.88 , pp. 1715-1723
    • Siu, S.C.1    Rivera, J.M.2    Guerrero, J.L.3
  • 3
    • 0028877208 scopus 로고
    • Three-dimensional echocardiography improves noninvasive assessment of left ventricular volume and performance
    • Siu SC, Levine RA, Rivera JM, et al : Three-dimensional echocardiography improves noninvasive assessment of left ventricular volume and performance. Am Heart J 1995 130 : 812 822.
    • (1995) Am Heart J , vol.130 , pp. 812-822
    • Siu, S.C.1    Levine, R.A.2    Rivera, J.M.3
  • 4
    • 4143108001 scopus 로고    scopus 로고
    • Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiography
    • Jenkins C, Bricknell K, Hanekom L, et al : Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiography. J Am Coll Cardiol 2004 44 : 878 886.
    • (2004) J Am Coll Cardiol , vol.44 , pp. 878-886
    • Jenkins, C.1    Bricknell, K.2    Hanekom, L.3
  • 5
    • 0037271793 scopus 로고    scopus 로고
    • Analysis of global systolic and diastolic left ventricular performance using volume-time curves by real-time three-dimensional echocardiography
    • Zeidan Z, Erbel R, Barkhausen J, et al : Analysis of global systolic and diastolic left ventricular performance using volume-time curves by real-time three-dimensional echocardiography. J Am Soc Echocardiogr 2003 16 : 29 37.
    • (2003) J Am Soc Echocardiogr , vol.16 , pp. 29-37
    • Zeidan, Z.1    Erbel, R.2    Barkhausen, J.3
  • 6
    • 17144461250 scopus 로고    scopus 로고
    • High-resolution transthoracic real-time three-dimensional echocardiography: Quantitation of cardiac volumes and function using semi-automatic border detection and comparison with cardiac magnetic resonance imaging
    • Kuhl HP, Schreckenberg M, Rulands D, et al : High-resolution transthoracic real-time three-dimensional echocardiography: Quantitation of cardiac volumes and function using semi-automatic border detection and comparison with cardiac magnetic resonance imaging. J Am Coll Cardiol 2004 43 : 2083 2090.
    • (2004) J Am Coll Cardiol , vol.43 , pp. 2083-2090
    • Kuhl, H.P.1    Schreckenberg, M.2    Rulands, D.3
  • 7
    • 0028888985 scopus 로고
    • Adult congenital heart disease: Use of transthoracic echocardiography versus magnetic resonance imaging scanning
    • Simpson IA, Sahn DJ : Adult congenital heart disease: Use of transthoracic echocardiography versus magnetic resonance imaging scanning. Am J Card Imaging 1995 9 : 29 37.
    • (1995) Am J Card Imaging , vol.9 , pp. 29-37
    • Simpson, I.A.1    Sahn, D.J.2
  • 8
    • 20144389305 scopus 로고    scopus 로고
    • Rapid full volume data acquisition by real-time 3-dimensional echocardiography for assessment of left ventricular indexes in children: A validation study compared with magnetic resonance imaging
    • Bu L, Munns S, Zhang H, et al : Rapid full volume data acquisition by real-time 3-dimensional echocardiography for assessment of left ventricular indexes in children: A validation study compared with magnetic resonance imaging. J Am Soc Echocardiogr 2005 18 : 299 305.
    • (2005) J Am Soc Echocardiogr , vol.18 , pp. 299-305
    • Bu, L.1    Munns, S.2    Zhang, H.3
  • 9
    • 14744296915 scopus 로고    scopus 로고
    • Comparison of left ventricular volumes and ejection fractions measured by three-dimensional echocardiography versus by two-dimensional echocardiography and cardiac magnetic resonance in patients with various cardiomyopathies
    • Gutierrez-Chico JL, Zamorano JL, Perez de Isla L, et al : Comparison of left ventricular volumes and ejection fractions measured by three-dimensional echocardiography versus by two-dimensional echocardiography and cardiac magnetic resonance in patients with various cardiomyopathies. Am J Cardiol 2005 95 : 809 813.
    • (2005) Am J Cardiol , vol.95 , pp. 809-813
    • Gutierrez-Chico, J.L.1    Zamorano, J.L.2    Perez De Isla, L.3
  • 10
    • 33748560820 scopus 로고    scopus 로고
    • Rapid and accurate measurement of left ventricular function with a new second-harmonic fast-rotating transducer and semi-automated border detection
    • Krenning BJ, Voormolen MM, van Geuns RJ, et al : Rapid and accurate measurement of left ventricular function with a new second-harmonic fast-rotating transducer and semi-automated border detection. Echocardiography 2006 23 : 447 454.
    • (2006) Echocardiography , vol.23 , pp. 447-454
    • Krenning, B.J.1    Voormolen, M.M.2    Van Geuns, R.J.3
  • 11
    • 33646693410 scopus 로고    scopus 로고
    • Contemporary definitions and classification of the cardiomyopathies: An American Heart Association Scientific Statement from the Council on Clinical Cardiology, Heart Failure and Transplantation Committee; Quality of Care and Outcomes Research and Functional Genomics and Translational Biology Interdisciplinary Working Groups; And Council on Epidemiology and Prevention
    • Maron BJ, Towbin JA, Thiene G, et al : Contemporary definitions and classification of the cardiomyopathies: An American Heart Association Scientific Statement from the Council on Clinical Cardiology, Heart Failure and Transplantation Committee; Quality of Care and Outcomes Research and Functional Genomics and Translational Biology Interdisciplinary Working Groups; and Council on Epidemiology and Prevention. Circulation 2006 113 : 1807 1816.
    • (2006) Circulation , vol.113 , pp. 1807-1816
    • Maron, B.J.1    Towbin, J.A.2    Thiene, G.3
  • 12
    • 0032695118 scopus 로고    scopus 로고
    • MRI-derived left ventricular function parameters and mass in healthy young adults: Relation with gender and body size
    • Marcus JT, DeWaal LK, Gotte MJ, et al : MRI-derived left ventricular function parameters and mass in healthy young adults: Relation with gender and body size. Int J Card Imaging 1999 15 : 411 419.
    • (1999) Int J Card Imaging , vol.15 , pp. 411-419
    • Marcus, J.T.1    Dewaal, L.K.2    Gotte, M.J.3
  • 13
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG : Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986 1 : 307 310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 14
    • 30844431512 scopus 로고    scopus 로고
    • Real-time transthoracic three-dimensional echocardiographic assessment of left ventricular volume and ejection fraction in congenital heart disease
    • Van Den Bosch AE, Robbers-Visser D, Krenning BJ, et al : Real-time transthoracic three-dimensional echocardiographic assessment of left ventricular volume and ejection fraction in congenital heart disease. J Am Soc Echocardiogr 2006 19 : 1 6.
    • (2006) J Am Soc Echocardiogr , vol.19 , pp. 1-6
    • Van Den Bosch, A.E.1    Robbers-Visser, D.2    Krenning, B.J.3
  • 15
    • 32144432629 scopus 로고    scopus 로고
    • Rapid online quantification of left ventricular volume from real-time three-dimensional echocardiographic data
    • Jacobs LD, Salgo IS, Goonewardena S, et al : Rapid online quantification of left ventricular volume from real-time three-dimensional echocardiographic data. Eur Heart J 2006 27 : 460 468.
    • (2006) Eur Heart J , vol.27 , pp. 460-468
    • Jacobs, L.D.1    Salgo, I.S.2    Goonewardena, S.3
  • 16
    • 33747431187 scopus 로고    scopus 로고
    • Quantitative Assessment of Left Ventricular Size and Function. Side-by-Side Comparison of Real-Time Three-Dimensional Echocardiography and Computed Tomography with Magnetic Resonance Reference
    • Sugeng L, Mor-Avi V, Weinert L, et al : Quantitative Assessment of Left Ventricular Size and Function. Side-by-Side Comparison of Real-Time Three-Dimensional Echocardiography and Computed Tomography With Magnetic Resonance Reference. Circulation 2006 114 : 654 661.
    • (2006) Circulation , vol.114 , pp. 654-661
    • Sugeng, L.1    Mor-Avi, V.2    Weinert, L.3
  • 17
    • 33748090271 scopus 로고    scopus 로고
    • Accuracy and feasibility of online 3-dimensional echocardiography for measurement of left ventricular parameters
    • Jenkins C, Chan J, Hanekom L, et al : Accuracy and feasibility of online 3-dimensional echocardiography for measurement of left ventricular parameters. J Am Soc Echocardiogr 2006 19 : 1119 1128.
    • (2006) J Am Soc Echocardiogr , vol.19 , pp. 1119-1128
    • Jenkins, C.1    Chan, J.2    Hanekom, L.3
  • 18
    • 33747816093 scopus 로고    scopus 로고
    • New generation 3-dimensional echocardiography for left ventricular volumetric and functional measurements: Comparison with cardiac magnetic resonance
    • Nikitin NP, Constantin C, Loh PH, et al : New generation 3-dimensional echocardiography for left ventricular volumetric and functional measurements: Comparison with cardiac magnetic resonance. Eur J Echocardiogr 2006 7 : 365 372.
    • (2006) Eur J Echocardiogr , vol.7 , pp. 365-372
    • Nikitin, N.P.1    Constantin, C.2    Loh, P.H.3
  • 19
    • 33745127684 scopus 로고    scopus 로고
    • Automatic quantitative left ventricular analysis of cine MR images by using three-dimensional information for contour detection
    • van Geuns RJ, Baks T, Gronenschild EH, et al : Automatic quantitative left ventricular analysis of cine MR images by using three-dimensional information for contour detection. Radiology 2006 240 : 215 221.
    • (2006) Radiology , vol.240 , pp. 215-221
    • Van Geuns, R.J.1    Baks, T.2    Gronenschild, E.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.