메뉴 건너뛰기




Volumn 50, Issue 6, 2012, Pages 2114-2117

Performance of the novel Qiagen artus QS-RGQ viral load assays compared to that of the abbott realtime system with genetically diversified HIV and hepatitis C virus plasma specimens

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ARTICLE; ASSAY; BLOOD SAMPLING; CONTROLLED STUDY; GENE SEQUENCE; GENOTYPE; HEPATITIS C VIRUS; HUMAN IMMUNODEFICIENCY VIRUS; INTERMETHOD COMPARISON; LIMIT OF DETECTION; NONHUMAN; PRIORITY JOURNAL; REAL TIME POLYMERASE CHAIN REACTION; STRUCTURAL GENE; VIRUS LOAD; VIRUS LOAD ASSAY;

EID: 84862087892     PISSN: 00951137     EISSN: 1098660X     Source Type: Journal    
DOI: 10.1128/JCM.05874-11     Document Type: Article
Times cited : (12)

References (22)
  • 1
    • 84872155775 scopus 로고    scopus 로고
    • Anonymous. 17 June posting date. U.S. Food and Drug Administration (FDA), Silver Spring, MD
    • Anonymous. 17 June 2011, posting date. Class 2 recall: COBAS® Ampli-Prep/COBAS® TaqMan® HCVtest, CE-IVD. U.S. Food and Drug Administration (FDA), Silver Spring, MD. http://www.accessdata.fda.gov/scripts/ cdrh/cfdocs/cfres/res.cfm?id=100296.
    • (2011) Class 2 Recall: COBAS® Ampli-Prep/COBAS® TaqMan® HCVtest, CE-IVD
  • 2
    • 79960097330 scopus 로고    scopus 로고
    • Anonymous. 10 August accession date. National Center for Biotechnology Information, Bethesda, MD
    • Anonymous. 10 August 2011, accession date. National Center for Biotechnology Information (NCBI) genotyping tool. National Center for Biotechnology Information, Bethesda, MD. http://www.ncbi.nlm.nih.gov/projects/ genotyping/formpage.cgi.
    • (2011) National Center for Biotechnology Information (NCBI) Genotyping Tool
  • 3
    • 84862063987 scopus 로고    scopus 로고
    • Anonymous. 10 August accession date. Stanford University, Stanford, CA
    • Anonymous. 10 August 2011, accession date. Stanford University HIV drug resistance database. Stanford University, Stanford, CA. http://hivdb.stanford. edu.
    • (2011) Stanford University HIV Drug Resistance Database
  • 4
    • 84872162844 scopus 로고    scopus 로고
    • Anonymous. 10 August, accession date. Department of Virology, University of Duisburg, Essen, Germany
    • Anonymous. 10 August 2011, accession date. HCV-Panel (Genotypisierung). Department of Virology, University of Duisburg, Essen, Germany. http://www.uni-due.de/virologie/HCV-Panel.html.
    • (2011) HCV-Panel (Genotypisierung)
  • 5
    • 33644500330 scopus 로고    scopus 로고
    • Verbot der Verwendung des HPS COBAS TaqMan HCV test (Roche Diagnostics GmbH, 68298 Mannheim) bei der Herstellung von zellulären Blutkomponenten und gefrorenem Frischplasma
    • Anonymous Paul-Ehrlich-Institut (ed), Paul-Ehrlich-Institut, Langen, Germany
    • Anonymous. 2004. Verbot der Verwendung des HPS COBAS TaqMan HCV test (Roche Diagnostics GmbH, 68298 Mannheim) bei der Herstellung von zellulären Blutkomponenten und gefrorenem Frischplasma, p 19770. In Paul-Ehrlich-Institut (ed), Bundesanzeiger nr. 166. Paul-Ehrlich-Institut, Langen, Germany.
    • (2004) Bundesanzeiger , vol.166 , pp. 19770
  • 6
    • 0036197584 scopus 로고    scopus 로고
    • Performance of the new bayer VERSANT HCV RNA 3.0 assay for quantitation of hepatitis C virus RNA in plasma and serum: Conversion to international units and comparison with the Roche COBAS amplicor HCV monitor, version 2.0, assay
    • DOI 10.1128/JCM.40.3.788-793.2002
    • Beld M, et al. 2002. Performance of the new Bayer VERSANT HCV RNA 3.0 assay for quantitation of hepatitis C virus RNA in plasma and serum: conversion to international units and comparison with the Roche COBAS Amplicor HCV Monitor, version 2.0, assay. J. Clin. Microbiol. 40:788-793. (Pubitemid 34208624)
    • (2002) Journal of Clinical Microbiology , vol.40 , Issue.3 , pp. 788-793
    • Beld, M.1    Sentjens, R.2    Rebers, S.3    Weegink, C.4    Weel, J.5    Sol, C.6    Boom, R.7
  • 7
    • 34547395999 scopus 로고    scopus 로고
    • Overestimation and underestimation of hepatitis C virus RNA levels in a widely used real-time polymerase chain reaction-based method
    • DOI 10.1002/hep.21656
    • Chevaliez S, Bouvier-Alias M, Brillet R, Pawlotsky JM. 2007. Overestimation and underestimation of hepatitis C virus RNA levels in a widely used real-time polymerase chain reaction-based method. Hepatology 46:22-31. (Pubitemid 47171917)
    • (2007) Hepatology , vol.46 , Issue.1 , pp. 22-31
    • Chevaliez, S.1    Bouvier-Alias, M.2    Brillet, R.3    Pawlotsky, J.-M.4
  • 9
    • 61449094626 scopus 로고    scopus 로고
    • A novel diagnostic target in the hepatitis C virus genome
    • doi:10.1371/journal.pmed.1000031.
    • Drexler JF, et al. 2009. A novel diagnostic target in the hepatitis C virus genome. PLoS Med. 6:e31. doi:10.1371/journal.pmed.1000031.
    • (2009) PLoS Med. , vol.6
    • Drexler, J.F.1
  • 10
    • 33750851598 scopus 로고    scopus 로고
    • HIV-1 viral load assays for resource-limited settings
    • doi:10.1371/journal.pmed.0030417.
    • Fiscus SA, et al. 2006. HIV-1 viral load assays for resource-limited settings. PLoS Med. 3:e417. doi:10.1371/journal.pmed.0030417.
    • (2006) PLoS Med. , vol.3
    • Fiscus, S.A.1
  • 11
    • 33644523760 scopus 로고    scopus 로고
    • Clinical performance of the new Roche COBAS TaqMan HCV test and High Pure system for extraction, detection and quantitation of HCV RNA in plasma and serum
    • Gelderblom HC, Menting S, Beld MG. 2006. Clinical performance of the new Roche COBAS TaqMan HCV test and High Pure system for extraction, detection and quantitation of HCV RNA in plasma and serum. Antivir. Ther. 11:95-103.
    • (2006) Antivir. Ther. , vol.11 , pp. 95-103
    • Gelderblom, H.C.1    Menting, S.2    Beld, M.G.3
  • 13
    • 0034461502 scopus 로고    scopus 로고
    • Improved version 2.0 qualitative and quantitative AMPLICOR reverse transcription-PCR tests for hepatitis C virus RNA: Calibration to international units, enhanced genotype reactivity, and performance characteristics
    • Lee SC, et al. 2000. Improved version 2.0 qualitative and quantitative AMPLICOR reverse transcription-PCR tests for hepatitis C virus RNA: calibration to international units, enhanced genotype reactivity, and performance characteristics. J. Clin. Microbiol. 38:4171-4179. (Pubitemid 32233222)
    • (2000) Journal of Clinical Microbiology , vol.38 , Issue.11 , pp. 4171-4179
    • Lee, S.C.1    Antony, A.2    Lee, N.3    Leibow, J.4    Yang, J.Q.5    Soviero, S.6    Gutekunst, K.7    Rosenstraus, M.8
  • 14
    • 34247186434 scopus 로고    scopus 로고
    • Use of sequence analysis of the NS5B region for routine genotyping of hepatitis C virus with reference to C/E1 and 5= untranslated region sequences
    • DOI 10.1128/JCM.02366-06
    • Murphy DG, et al. 2007. Use of sequence analysis of the NS5B region for routine genotyping of hepatitis C virus with reference to C/E1 and 5= untranslated region sequences. J. Clin. Microbiol. 45:1102-1112. (Pubitemid 46626471)
    • (2007) Journal of Clinical Microbiology , vol.45 , Issue.4 , pp. 1102-1112
    • Murphy, D.G.1    Willems, B.2    Deschenes, M.3    Hilzenrat, N.4    Mousseau, R.5    Sabbah, S.6
  • 15
    • 33845871440 scopus 로고    scopus 로고
    • HIV-1 viral load assays for resource-limited settings: Clades matter
    • (doi:10.1371/journal.pmed.0030538); author reply, e550
    • Preiser W, Drexler JF, Drosten C. 2006. HIV-1 viral load assays for resource-limited settings: clades matter. PLoS Med. 3:e538 (doi:10.1371/journal. pmed.0030538); author reply, e550.
    • (2006) PLoS Med. , vol.3
    • Preiser, W.1    Drexler, J.F.2    Drosten, C.3
  • 17
    • 4143071570 scopus 로고    scopus 로고
    • Detection of HIV-1 and HCV infections among antibody-negative blood donors by nucleic acid-amplification testing
    • Stramer SL, et al. 2004. Detection of HIV-1 and HCV infections among antibody-negative blood donors by nucleic acid-amplification testing. N. Engl. J. Med. 351:760-768.
    • (2004) N. Engl. J. Med. , vol.351 , pp. 760-768
    • Stramer, S.L.1
  • 19
    • 77954692660 scopus 로고    scopus 로고
    • Antiretroviral treatment of adult HIV infection: 2010 recommendations of the International AIDS Society-USA Panel
    • Thompson MA, et al. 2010. Antiretroviral treatment of adult HIV infection: 2010 recommendations of the International AIDS Society-USA Panel. JAMA 304:321-333.
    • (2010) JAMA , vol.304 , pp. 321-333
    • Thompson, M.A.1
  • 21
    • 78650907952 scopus 로고    scopus 로고
    • Comparative evaluation of the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 version 2 test using the TaqMan 48 analyzer and the Abbott RealTime HIV-1 assay
    • van Rensburg EJ, Tait K, Watt A, Schall R. 2011. Comparative evaluation of the Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 version 2 test using the TaqMan 48 analyzer and the Abbott RealTime HIV-1 assay. J. Clin. Microbiol. 49:377-379.
    • (2011) J. Clin. Microbiol. , vol.49 , pp. 377-379
    • Van Rensburg, E.J.1    Tait, K.2    Watt, A.3    Schall, R.4
  • 22
    • 77957018729 scopus 로고    scopus 로고
    • Advances in developing HIV-1 viral load assays for resource-limited settings
    • Wang S, Xu F, Demirci U. 2010. Advances in developing HIV-1 viral load assays for resource-limited settings. Biotechnol. Adv. 28:770-781.
    • (2010) Biotechnol. Adv. , vol.28 , pp. 770-781
    • Wang, S.1    Xu, F.2    Demirci, U.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.