메뉴 건너뛰기




Volumn , Issue , 2011, Pages 608-611

Restoration of stance phase knee flexion during walking after spinal cord injury using a variable impedance orthosis

Author keywords

[No Author keywords available]

Indexed keywords

ABLE-BODIED GAIT; CLOSED LOOPS; FINITE-STATE CONTROLLERS; FUNCTIONAL NEUROMUSCULAR STIMULATION; KNEE FLEXIONS; LOWER EXTREMITY; NEURO-PROSTHESIS; ORTHOSIS; SPINAL CORD INJURY; STANCE PHASE; UNEVEN TERRAIN; VARIABLE IMPEDANCE;

EID: 84861936436     PISSN: 1557170X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2011.6090135     Document Type: Conference Paper
Times cited : (6)

References (13)
  • 1
    • 0029784561 scopus 로고    scopus 로고
    • Paraplegic locomotion: A review
    • A.V. Nene, H.J. Hermens, G. Zilvold, "Paraplegic locomotion: A review," Spinal Cord, vol. 34, no. 9, pp. 507-524, 1996.
    • (1996) Spinal Cord , vol.34 , Issue.9 , pp. 507-524
    • Nene, A.V.1    Hermens, H.J.2    Zilvold, G.3
  • 2
    • 0028443327 scopus 로고
    • Synthesis of paraplegic gait with multichannel functional neuromuscular stimulation
    • R. Kobetic, E.B. Marsolais, "Synthesis of paraplegic gait with multichannel functional neuromuscular stimulation," IEEE Trans. Rehab. Eng., vol. 2, no. 2, pp. 66-79, 1994.
    • (1994) IEEE Trans. Rehab. Eng. , vol.2 , Issue.2 , pp. 66-79
    • Kobetic, R.1    Marsolais, E.B.2
  • 3
    • 1842413032 scopus 로고    scopus 로고
    • Reciprocating gait orthosis powered with electrical stimulation (RGO II). Part I: Performance evaluation of 70 paraplegic patients
    • M. Solomonow, E. Aguilar, E. Reisin, R.V. Baratta, R. Best, T. Coetzee, R. D'Ambrosia, "Reciprocating gait orthosis powered with electrical stimulation (RGO II). Part I: Performance evaluation of 70 paraplegic patients," Orthopedics, vol. 20, no.4, pp. 315-324, 1997.
    • (1997) Orthopedics , vol.20 , Issue.4 , pp. 315-324
    • Solomonow, M.1    Aguilar, E.2    Reisin, E.3    Baratta, R.V.4    Best, R.5    Coetzee, T.6    D'Ambrosia, R.7
  • 4
    • 67049097175 scopus 로고    scopus 로고
    • Engineering design review of stance-control knee-ankle-foot orthoses
    • T. Yakimovich, E.D. Lemaire, J. Kofman, "Engineering design review of stance-control knee-ankle-foot orthoses," J. Rehabil Res Dev, vol. 46, no. 2, pp. 257-267, 2009.
    • (2009) J. Rehabil Res Dev , vol.46 , Issue.2 , pp. 257-267
    • Yakimovich, T.1    Lemaire, E.D.2    Kofman, J.3
  • 5
    • 0034896110 scopus 로고    scopus 로고
    • A new hybrid spring brake orthosis for controlling hip and knee flexion in the swing phase
    • S. Gharooni, B. Heller, M.O. Tokhi, "A new hybrid spring brake orthosis for controlling hip and knee flexion in the swing phase," IEEE Trans. Neur. Sys. Rehab. Eng., vol. 9, no.1, pp. 106-107, 2001.
    • (2001) IEEE Trans. Neur. Sys. Rehab. Eng. , vol.9 , Issue.1 , pp. 106-107
    • Gharooni, S.1    Heller, B.2    Tokhi, M.O.3
  • 6
    • 0037756783 scopus 로고    scopus 로고
    • A knee and ankle flexing hybrid orthosis for paraplegic ambulation
    • P.J. Greene, M.H. Granat, "A knee and ankle flexing hybrid orthosis for paraplegic ambulation," Med. Eng. Phys., vol. 25, pp. 539-545, 2003.
    • (2003) Med. Eng. Phys. , vol.25 , pp. 539-545
    • Greene, P.J.1    Granat, M.H.2
  • 8
    • 0030985489 scopus 로고    scopus 로고
    • Energy cost of walking: Comparison of "intelligent prosthesis" with conventional mechanism
    • J.G. Buckley, W.D. Spence, S.E. Solomonidis, "Energy cost of walking: comparison of "intelligent prosthesis" with conventional mechanism," Arch. Phys. Med. Rehab., vol. 78, pp. 330-333, 1997.
    • (1997) Arch. Phys. Med. Rehab. , vol.78 , pp. 330-333
    • Buckley, J.G.1    Spence, W.D.2    Solomonidis, S.E.3
  • 9
    • 22644438268 scopus 로고    scopus 로고
    • A clinical comparison of variable-damping and mechanically passive prosthetic knee devices
    • J.L. Johansson, D.M. Sherrill, P.O. Riley, P. Bonato, H. Herr, "A clinical comparison of variable-damping and mechanically passive prosthetic knee devices," Am. J. Phys. Med. Rehab., vol. 84, pp. 563-575, 2005.
    • (2005) Am. J. Phys. Med. Rehab. , vol.84 , pp. 563-575
    • Johansson, J.L.1    Sherrill, D.M.2    Riley, P.O.3    Bonato, P.4    Herr, H.5
  • 11
    • 0034895669 scopus 로고    scopus 로고
    • Real-time gait event detection for paraplegic FES walking
    • M.M. Skelly, H.J. Chizeck, "Real-time gait event detection for paraplegic FES walking," IEEE Trans. Neur Sys Rehab Eng, vol. 9, no. 1, pp. 59-68, 2001.
    • (2001) IEEE Trans. Neur Sys Rehab Eng , vol.9 , Issue.1 , pp. 59-68
    • Skelly, M.M.1    Chizeck, H.J.2
  • 12
    • 38649089762 scopus 로고    scopus 로고
    • Design and control of a powered transfemoral prosthesis
    • F. Sup, A. Bohara, M. Goldfarb, "Design and control of a powered transfemoral prosthesis," Int. J. Robot. Res., vol. 27, no. 2, pp. 263-273, 2008.
    • (2008) Int. J. Robot. Res. , vol.27 , Issue.2 , pp. 263-273
    • Sup, F.1    Bohara, A.2    Goldfarb, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.