메뉴 건너뛰기




Volumn 169, Issue , 2012, Pages 96-105

Application of modified multiwall carbon nanotubes paste electrode for simultaneous voltammetric determination of morphine and diclofenac in biological and pharmaceutical samples

Author keywords

Morphine and diclofenac; Multiwall carbon nanotubes; Vinylferrocene; Voltammetric measurement

Indexed keywords

CARBON NANOTUBES PASTE ELECTRODES; DETECTION LIMITS; DICLOFENAC; ELECTROCATALYTIC ACTIVITY; ELECTROCHEMICAL RESPONSE; MODIFIED CARBON PASTE ELECTRODE; MODIFIED ELECTRODES; PEAK CURRENTS; PEAK POTENTIALS; POTENTIAL DIFFERENCE; REAL SAMPLES; SQUARE WAVE VOLTAMMETRY; SQUARE WAVES; STRUCTURAL MORPHOLOGY; VINYLFERROCENE; VOLTAMMETRIC DETERMINATION; VOLTAMMETRIC MEASUREMENTS; VOLTAMMETRIC PEAK; VOLTAMMETRIC SENSOR;

EID: 84861844229     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2012.03.059     Document Type: Article
Times cited : (222)

References (57)
  • 1
    • 0025946474 scopus 로고
    • Voltammetric behavior of morphine at a glassy carbon electrode and its determination in human serum by liquid chromatography with electrochemical detection under basic conditions
    • P.H. Jordan, and J.P. Hart Voltammetric behavior of morphine at a glassy carbon electrode and its determination in human serum by liquid chromatography with electrochemical detection under basic conditions Analyst 116 1991 991 996
    • (1991) Analyst , vol.116 , pp. 991-996
    • Jordan, P.H.1    Hart, J.P.2
  • 2
    • 0027956428 scopus 로고
    • Gas chromatographic-mass spectrometric procedures used for the identification and determination of morphine, codeine and 6-monoacetyl morphine
    • R. Wasels, and F. Belleville Gas chromatographic-mass spectrometric procedures used for the identification and determination of morphine, codeine and 6-monoacetyl morphine J. Chromatogr. 674 1994 225 234
    • (1994) J. Chromatogr. , vol.674 , pp. 225-234
    • Wasels, R.1    Belleville, F.2
  • 3
    • 0024516157 scopus 로고
    • High-performance liquid chromatographic determination of morphine in biological samples: An overview of separation methods and detection techniques
    • F. Tagliaro, D. Franchi, R. Dorizzi, and M. Marigo High-performance liquid chromatographic determination of morphine in biological samples: an overview of separation methods and detection techniques J. Chromatogr. 488 1989 215 228
    • (1989) J. Chromatogr. , vol.488 , pp. 215-228
    • Tagliaro, F.1    Franchi, D.2    Dorizzi, R.3    Marigo, M.4
  • 4
    • 0034717231 scopus 로고    scopus 로고
    • High-performance liquid chromatographic determination of morphine and its 3- and 6-glucuronide metabolites by two-step solid-phase extraction
    • Q.C. Meng, M.S. Cepeda, T. Kramer, H. Zou, D.J. Matoka, and J. Farrar High-performance liquid chromatographic determination of morphine and its 3- and 6-glucuronide metabolites by two-step solid-phase extraction J. Chromatogr. B 742 2000 115 123
    • (2000) J. Chromatogr. B , vol.742 , pp. 115-123
    • Meng, Q.C.1    Cepeda, M.S.2    Kramer, T.3    Zou, H.4    Matoka, D.J.5    Farrar, J.6
  • 5
    • 0026688952 scopus 로고
    • Comparative study of different extractive procedures to quantify morphine in urine by HPLC-UV
    • M.E. Soares, V. Seabra, and M.D.A. Bastos Comparative study of different extractive procedures to quantify morphine in urine by HPLC-UV J. Liq. Chromatogr. 15 1992 1533 1541
    • (1992) J. Liq. Chromatogr. , vol.15 , pp. 1533-1541
    • Soares, M.E.1    Seabra, V.2    Bastos, M.D.A.3
  • 7
    • 0030968471 scopus 로고    scopus 로고
    • Determination of heroin, 6-acetylmorphine, and morphine in biological fluids using their propionyl derivatives with ion trap GC-MS
    • J.G. Guillot, M. Lefebvre, and J.P. Weber Determination of heroin, 6-acetylmorphine, and morphine in biological fluids using their propionyl derivatives with ion trap GC-MS J. Anal. Toxicol. 21 1997 127 133
    • (1997) J. Anal. Toxicol. , vol.21 , pp. 127-133
    • Guillot, J.G.1    Lefebvre, M.2    Weber, J.P.3
  • 8
    • 0026006832 scopus 로고
    • A simple, rapid method for the simultaneous determination of morphine and its principal metabolites in plasma using high-performance liquid chromatography and fluorometric detection
    • P. Glare, T. Walsh, and C. Pippenger A simple, rapid method for the simultaneous determination of morphine and its principal metabolites in plasma using high-performance liquid chromatography and fluorometric detection Ther. Drug Monit. 13 1991 226 232
    • (1991) Ther. Drug Monit. , vol.13 , pp. 226-232
    • Glare, P.1    Walsh, T.2    Pippenger, C.3
  • 9
    • 0032908894 scopus 로고    scopus 로고
    • Direct injection of edible oils as micro emulsions in a micellar mobile phase applied to the liquid chromatographic determination of synthetic antioxidants
    • S. Hara, S. Mochinaga, M. Fukuzawa, and O.N.T. Kuroda Direct injection of edible oils as micro emulsions in a micellar mobile phase applied to the liquid chromatographic determination of synthetic antioxidants Anal. Chim. Acta 387 1999 121 134
    • (1999) Anal. Chim. Acta , vol.387 , pp. 121-134
    • Hara, S.1    Mochinaga, S.2    Fukuzawa, M.3    Kuroda, O.N.T.4
  • 10
    • 0034693381 scopus 로고    scopus 로고
    • Determination of morphine by capillary electrophoresis immunoassay in thermally reversible hydrogel-modified buffer and laser-induced fluorescence detection
    • X.X. Zhang, J. Li, J. Gao, L. Sun, and W.B. Chang Determination of morphine by capillary electrophoresis immunoassay in thermally reversible hydrogel-modified buffer and laser-induced fluorescence detection J. Chromatogr. A 895 2000 1 7
    • (2000) J. Chromatogr. A , vol.895 , pp. 1-7
    • Zhang, X.X.1    Li, J.2    Gao, J.3    Sun, L.4    Chang, W.B.5
  • 11
    • 0037096999 scopus 로고    scopus 로고
    • Simultaneous determination of in total 17 opium alkaloids and opioids in blood and urine by fast liquid chromatography - Diode-array detection - Fluorescence detection, after solid-phase extraction
    • R. Dams, T. Benijts, W.E. Lambert, and A.P. De Leenheer Simultaneous determination of in total 17 opium alkaloids and opioids in blood and urine by fast liquid chromatography - diode-array detection - fluorescence detection, after solid-phase extraction J. Chromatogr. B 773 2002 53 61
    • (2002) J. Chromatogr. B , vol.773 , pp. 53-61
    • Dams, R.1    Benijts, T.2    Lambert, W.E.3    De Leenheer, A.P.4
  • 12
    • 0030364892 scopus 로고    scopus 로고
    • Determination of morphine in process streams by sequential injection analysis with chemiluminescence detection
    • N.W. Barnett, S.W. Lewis, and D.J. Tucker Determination of morphine in process streams by sequential injection analysis with chemiluminescence detection Fresenius' J. Anal. Chem. 355 1996 591 595
    • (1996) Fresenius' J. Anal. Chem. , vol.355 , pp. 591-595
    • Barnett, N.W.1    Lewis, S.W.2    Tucker, D.J.3
  • 13
    • 0031956344 scopus 로고    scopus 로고
    • Determination of morphine in water immiscible process streams using sequential injection analysis coupled with acidic permanganate chemiluminescence detection
    • N.W. Barnett, C.E. Lenehan, S.W. Lewis, D.J. Tucker, and K.M. Essery Determination of morphine in water immiscible process streams using sequential injection analysis coupled with acidic permanganate chemiluminescence detection Analyst 123 1998 601 605
    • (1998) Analyst , vol.123 , pp. 601-605
    • Barnett, N.W.1    Lenehan, C.E.2    Lewis, S.W.3    Tucker, D.J.4    Essery, K.M.5
  • 14
    • 0033783653 scopus 로고    scopus 로고
    • Pulsed flow chemistry: A new approach to solution handling for flow analysis coupled with chemiluminescence detection
    • S.W. Lewis, P.S. Francis, K.F. Lim, G.E. Jenkins, and X.D. Wang Pulsed flow chemistry: a new approach to solution handling for flow analysis coupled with chemiluminescence detection Analyst 125 2000 1869 1874
    • (2000) Analyst , vol.125 , pp. 1869-1874
    • Lewis, S.W.1    Francis, P.S.2    Lim, K.F.3    Jenkins, G.E.4    Wang, X.D.5
  • 15
    • 0032093651 scopus 로고    scopus 로고
    • A surface plasmon resonance-based immune sensor for highly sensitive detection of morphine
    • G. Sakai, K. Ogata, T.U. da, N. Miura, and N. Yamazoe A surface plasmon resonance-based immune sensor for highly sensitive detection of morphine Sens. Actuators B 49 1998 5 12
    • (1998) Sens. Actuators B , vol.49 , pp. 5-12
    • Sakai, G.1    Ogata, K.2    Da, T.U.3    Miura, N.4    Yamazoe, N.5
  • 16
    • 0037068533 scopus 로고    scopus 로고
    • Amperometric determination of morphine on cobalt hexacyanoferrate modified electrode in rat brain microdialysates
    • F. Xu, M. Gao, L. Wang, T. Zhou, L. Jin, and J. Jin Amperometric determination of morphine on cobalt hexacyanoferrate modified electrode in rat brain microdialysates Talanta 58 2002 427 432
    • (2002) Talanta , vol.58 , pp. 427-432
    • Xu, F.1    Gao, M.2    Wang, L.3    Zhou, T.4    Jin, L.5    Jin, J.6
  • 17
    • 20444434786 scopus 로고    scopus 로고
    • Amperometric detection of morphine at preheated glassy carbon electrode modified with multiwall carbon nanotubes
    • A. Salimi, R. Hallaj, and G.R. Khayatian Amperometric detection of morphine at preheated glassy carbon electrode modified with multiwall carbon nanotubes Electroanalysis 17 2005 873 879
    • (2005) Electroanalysis , vol.17 , pp. 873-879
    • Salimi, A.1    Hallaj, R.2    Khayatian, G.R.3
  • 18
    • 67649491065 scopus 로고    scopus 로고
    • Simple and rapid voltammetric determination of morphine at electrochemically pretreated glassy carbon electrodes
    • F. Li, J. Song, D. Gao, Q. Zhang, Han, and L. Niu Simple and rapid voltammetric determination of morphine at electrochemically pretreated glassy carbon electrodes Talanta 79 2009 845 850
    • (2009) Talanta , vol.79 , pp. 845-850
    • Li, F.1    Song, J.2    Gao, D.3    Zhang, Q.4    Han5    Niu, L.6
  • 19
    • 2342552469 scopus 로고    scopus 로고
    • Amperometric detection of morphine at a Prussian blue-modified indium tin oxide electrode
    • K.C. Ho, C.Y. Chen, H.C. Hsu, L.C. Chen, S.C. Shiesh, and X.Z. Lin Amperometric detection of morphine at a Prussian blue-modified indium tin oxide electrode Biosen. Bioelec. 20 2004 3 8
    • (2004) Biosen. Bioelec. , vol.20 , pp. 3-8
    • Ho, K.C.1    Chen, C.Y.2    Hsu, H.C.3    Chen, L.C.4    Shiesh, S.C.5    Lin, X.Z.6
  • 20
    • 56949104465 scopus 로고    scopus 로고
    • Simultaneous voltammetric and amperometric determination of morphine and codeine using a chemically modified-palladized aluminum electrode
    • M.H. Pournaghi-Azar, and A. Saadatirad Simultaneous voltammetric and amperometric determination of morphine and codeine using a chemically modified-palladized aluminum electrode J. Electroanal. Chem. 624 2008 293 298
    • (2008) J. Electroanal. Chem. , vol.624 , pp. 293-298
    • Pournaghi-Azar, M.H.1    Saadatirad, A.2
  • 21
    • 80053131757 scopus 로고    scopus 로고
    • An ionic liquid-type multiwall carbon nanotubes paste electrode for electrochemical investigation and determination of morphine
    • A.A. Ensafi, B. Rezaei, and H. Krimi-Maleh An ionic liquid-type multiwall carbon nanotubes paste electrode for electrochemical investigation and determination of morphine Ionics 17 2011 659 668
    • (2011) Ionics , vol.17 , pp. 659-668
    • Ensafi, A.A.1    Rezaei, B.2    Krimi-Maleh, H.3
  • 22
    • 36048965518 scopus 로고    scopus 로고
    • Simultaneous voltammetric determination of morphine and noscapine by adsorptive differential pulse stripping method and least-squares support vector machines
    • A. Niazia, J.B. Ghasemi, and M. Zendehdel Simultaneous voltammetric determination of morphine and noscapine by adsorptive differential pulse stripping method and least-squares support vector machines Talanta 74 2007 247 254
    • (2007) Talanta , vol.74 , pp. 247-254
    • Niazia, A.1    Ghasemi, J.B.2    Zendehdel, M.3
  • 23
    • 0024317575 scopus 로고
    • Diclofenac sodium
    • R.E. Small Diclofenac sodium Clin. Pharm. 8 1989 545 558
    • (1989) Clin. Pharm. , vol.8 , pp. 545-558
    • Small, R.E.1
  • 24
    • 0025140945 scopus 로고
    • Controlled-release indomethacin and sustained-release diclofenac sodium in the treatment of osteoarthritis: A comparative controlled clinical trial in general practice
    • N. Gostick, I.G. James, T.K. Khong, P. Roy, P.R. Shepherd, and A.J. Miller Controlled-release indomethacin and sustained-release diclofenac sodium in the treatment of osteoarthritis: a comparative controlled clinical trial in general practice Curr. Med. Res. Opin. 12 1990 135 142
    • (1990) Curr. Med. Res. Opin. , vol.12 , pp. 135-142
    • Gostick, N.1    James, I.G.2    Khong, T.K.3    Roy, P.4    Shepherd, P.R.5    Miller, A.J.6
  • 25
    • 0025148387 scopus 로고
    • Controlled-release indomethacin and sustained-release diclofenac sodium in the treatment of rheumatoid arthritis: A comparative controlled clinical trial
    • B. Crowley, J.J. Hamill, S. Lyndon, J.F. Mckellican, P. Williams, and A.J. Miller Controlled-release indomethacin and sustained-release diclofenac sodium in the treatment of rheumatoid arthritis: A comparative controlled clinical trial Med. Res. Opin. 12 1990 143 150
    • (1990) Med. Res. Opin. , vol.12 , pp. 143-150
    • Crowley, B.1    Hamill, J.J.2    Lyndon, S.3    McKellican, J.F.4    Williams, P.5    Miller, A.J.6
  • 26
    • 77952092878 scopus 로고    scopus 로고
    • GC-MS determination of diclofenac in human plasma
    • B. Yilmaz GC-MS determination of diclofenac in human plasma Chromatographia 71 2010 549 551
    • (2010) Chromatographia , vol.71 , pp. 549-551
    • Yilmaz, B.1
  • 27
    • 0030580109 scopus 로고    scopus 로고
    • Sensitive capillary gas chromatographic-mass spectrometric-selected-ion monitoring method for the determination of diclofenac concentrations in human plasma
    • M.R. Borenstein, Y. Xue, S. Cooper, and T.B. Tzeng Sensitive capillary gas chromatographic-mass spectrometric-selected-ion monitoring method for the determination of diclofenac concentrations in human plasma J. Chromatogr. B 685 1996 59 66
    • (1996) J. Chromatogr. B , vol.685 , pp. 59-66
    • Borenstein, M.R.1    Xue, Y.2    Cooper, S.3    Tzeng, T.B.4
  • 28
    • 0037420718 scopus 로고    scopus 로고
    • Liquid chromatographic determination of diclofenac in human synovial fluid
    • R. Roskar, and V. Kmetec Liquid chromatographic determination of diclofenac in human synovial fluid J. Chromatogr. B 788 2003 57 64
    • (2003) J. Chromatogr. B , vol.788 , pp. 57-64
    • Roskar, R.1    Kmetec, V.2
  • 29
    • 30444449007 scopus 로고    scopus 로고
    • Efficient high performance liquid chromatograph/ultraviolet method for determination of diclofenac and 4′-hydroxydiclofenac in rat serum
    • L. Kaphalia, B.S. Kaphalia, S. Kumar, M.F. Kanz, and M. Treinen-Moslen Efficient high performance liquid chromatograph/ultraviolet method for determination of diclofenac and 4′-hydroxydiclofenac in rat serum J. Chromatogr. B 830 2006 231 237
    • (2006) J. Chromatogr. B , vol.830 , pp. 231-237
    • Kaphalia, L.1    Kaphalia, B.S.2    Kumar, S.3    Kanz, M.F.4    Treinen-Moslen, M.5
  • 30
    • 0035813550 scopus 로고    scopus 로고
    • High-performance liquid chromatographic determination of diclofenac in human plasma after solid-phase extraction
    • C. Arcelloni, R. Lanzi, S. Pedercini, G. Molteni, I. Fermo, and A. Pontiroli High-performance liquid chromatographic determination of diclofenac in human plasma after solid-phase extraction J. Chromatogr. B 763 2001 195 200
    • (2001) J. Chromatogr. B , vol.763 , pp. 195-200
    • Arcelloni, C.1    Lanzi, R.2    Pedercini, S.3    Molteni, G.4    Fermo, I.5    Pontiroli, A.6
  • 31
    • 50049083535 scopus 로고    scopus 로고
    • Liquid chromatography-tandem mass spectrometric assay for diclofenac and three primary metabolites in mouse plasma
    • R.W. Sparidans, J.S. Lagas, A.H. Schinkel, J.H.M. Schellens, and J.H. Beijnen Liquid chromatography-tandem mass spectrometric assay for diclofenac and three primary metabolites in mouse plasma J. Chromatogr. B 872 2008 77 82
    • (2008) J. Chromatogr. B , vol.872 , pp. 77-82
    • Sparidans, R.W.1    Lagas, J.S.2    Schinkel, A.H.3    Schellens, J.H.M.4    Beijnen, J.H.5
  • 32
    • 26944460770 scopus 로고    scopus 로고
    • A simple spectrophotometric method for determination of sodium diclofenac in pharmaceutical formulations
    • A.A. Matin, M.A. Farajzadeh, and A. Joyuban A simple spectrophotometric method for determination of sodium diclofenac in pharmaceutical formulations Il Farmaco 60 2005 855 858
    • (2005) Il Farmaco , vol.60 , pp. 855-858
    • Matin, A.A.1    Farajzadeh, M.A.2    Joyuban, A.3
  • 33
    • 58149322653 scopus 로고
    • Spectrophotometric determination of diclofenac sodium with methylene blue
    • J.C. Botello, and G.P. Caballero Spectrophotometric determination of diclofenac sodium with methylene blue Talanta 42 1995 105 108
    • (1995) Talanta , vol.42 , pp. 105-108
    • Botello, J.C.1    Caballero, G.P.2
  • 34
    • 30744472168 scopus 로고    scopus 로고
    • Spectrophotometric determination of diclofenac in pharmaceutical preparations
    • R.L. Souza, and M. Tubino Spectrophotometric determination of diclofenac in pharmaceutical preparations J. Braz. Chem. Soc. 16 2005 1068 1073
    • (2005) J. Braz. Chem. Soc. , vol.16 , pp. 1068-1073
    • Souza, R.L.1    Tubino, M.2
  • 35
    • 0023143040 scopus 로고
    • Spectrophotometric analysis of diclofenac sodium and piroxicam and their pharmaceutical preparations
    • C.S. Sastry, A.R.M. Rao, and T.N.V. Prasad Spectrophotometric analysis of diclofenac sodium and piroxicam and their pharmaceutical preparations Anal. Lett. 20 1987 349 359
    • (1987) Anal. Lett. , vol.20 , pp. 349-359
    • Sastry, C.S.1    Rao, A.R.M.2    Prasad, T.N.V.3
  • 36
    • 0030732871 scopus 로고    scopus 로고
    • Spectrophotometric determination of diclofenac sodium in gel-ointment
    • I. Kramancheva, and I. Dobrev Spectrophotometric determination of diclofenac sodium in gel-ointment Anal. Lett. 30 1997 2235 2249
    • (1997) Anal. Lett. , vol.30 , pp. 2235-2249
    • Kramancheva, I.1    Dobrev, I.2
  • 38
    • 77949303968 scopus 로고    scopus 로고
    • Electrochemical investigations of diclofenac at edge plane pyrolytic graphite electrode and its determination in human urine
    • R.N. Goyal, S. Chatterjee, and B. Agrawal Electrochemical investigations of diclofenac at edge plane pyrolytic graphite electrode and its determination in human urine Sens. Actuator B 145 2010 743 748
    • (2010) Sens. Actuator B , vol.145 , pp. 743-748
    • Goyal, R.N.1    Chatterjee, S.2    Agrawal, B.3
  • 39
    • 77956266489 scopus 로고    scopus 로고
    • The effect of modifying an edge-plane pyrolytic graphite electrode with single-wall carbon nanotubes on its use for sensing diclofenac
    • R.N. Goyal, S. Chatterjee, and A. Raj Singh Rana The effect of modifying an edge-plane pyrolytic graphite electrode with single-wall carbon nanotubes on its use for sensing diclofenac Carbon 48 2010 4136 4144
    • (2010) Carbon , vol.48 , pp. 4136-4144
    • Goyal, R.N.1    Chatterjee, S.2    Raj Singh Rana, A.3
  • 40
    • 70350424150 scopus 로고    scopus 로고
    • Determination of diclofenac on a dysprosium nanowire-modified carbon paste electrode accomplished in a flow injection system by advanced filtering
    • P. Daneshgar, P. Norouzi, M.R. Ganjali, R. Dinarvand, and A.A. Moosavi-Movahedi Determination of diclofenac on a dysprosium nanowire-modified carbon paste electrode accomplished in a flow injection system by advanced filtering Sensors 9 2009 7903 7918
    • (2009) Sensors , vol.9 , pp. 7903-7918
    • Daneshgar, P.1    Norouzi, P.2    Ganjali, M.R.3    Dinarvand, R.4    Moosavi-Movahedi, A.A.5
  • 41
    • 0032897894 scopus 로고    scopus 로고
    • Analgesic efficacy of paracetamol and diclofenac in children receiving PCA morphine
    • M.S. Morton, and K.O. Brien Analgesic efficacy of paracetamol and diclofenac in children receiving PCA morphine Br. J. Anaesth. 82 1999 715 717
    • (1999) Br. J. Anaesth. , vol.82 , pp. 715-717
    • Morton, M.S.1    Brien, K.O.2
  • 42
    • 0037008487 scopus 로고    scopus 로고
    • Carbon nanotubes - The route toward applications
    • R.H. Baughman, A. Zakhidov, and W.A. de Heer Carbon nanotubes - the route toward applications Science 297 2002 787 792
    • (2002) Science , vol.297 , pp. 787-792
    • Baughman, R.H.1    Zakhidov, A.2    De Heer, W.A.3
  • 43
    • 0038715138 scopus 로고    scopus 로고
    • Electrocatalytic properties and sensor applications of fullerenes and carbon nanotubes
    • B.S. Sherigara, W. Kutner, and F. D'Souza Electrocatalytic properties and sensor applications of fullerenes and carbon nanotubes Electroanalysis 15 2003 753 772
    • (2003) Electroanalysis , vol.15 , pp. 753-772
    • Sherigara, B.S.1    Kutner, W.2    D'Souza, F.3
  • 45
    • 76349095336 scopus 로고    scopus 로고
    • Modified multiwall carbon nanotubes paste electrode as a sensor for simultaneous determination of 6-thioguanine and folic acid using ferrocenedicarboxylic acid as a mediator
    • A.A. Ensafi, and H. Karimi-Maleh Modified multiwall carbon nanotubes paste electrode as a sensor for simultaneous determination of 6-thioguanine and folic acid using ferrocenedicarboxylic acid as a mediator J. Electroanal. Chem. 640 2010 75 83
    • (2010) J. Electroanal. Chem. , vol.640 , pp. 75-83
    • Ensafi, A.A.1    Karimi-Maleh, H.2
  • 46
    • 58149140094 scopus 로고    scopus 로고
    • Nanomolar and selective determination of epinephrine in the presence of norepinephrine using carbon paste electrode modified with carbon nanotubes and novel 2-(4-oxo-3-phenyl-3,4-dihydroquinazolinyl)-N′-phenyl- hydrazinecarbothioamide
    • H. Beitollahi, H. Karimi-Maleh, and H. Khabazzadeh Nanomolar and selective determination of epinephrine in the presence of norepinephrine using carbon paste electrode modified with carbon nanotubes and novel 2-(4-oxo-3-phenyl-3,4-dihydroquinazolinyl)-N′-phenyl- hydrazinecarbothioamide Anal. Chem. 80 2008 9848 9851
    • (2008) Anal. Chem. , vol.80 , pp. 9848-9851
    • Beitollahi, H.1    Karimi-Maleh, H.2    Khabazzadeh, H.3
  • 48
    • 78049256389 scopus 로고    scopus 로고
    • A voltammetric sensor based on modified multiwall carbon nanotubes for cysteamine determination in the presence of tryptophan using p-aminophenol as a mediator
    • A.A. Ensafi, and H. Karimi-Maleh A voltammetric sensor based on modified multiwall carbon nanotubes for cysteamine determination in the presence of tryptophan using p-aminophenol as a mediator Electroanalysis 22 2010 2558 2568
    • (2010) Electroanalysis , vol.22 , pp. 2558-2568
    • Ensafi, A.A.1    Karimi-Maleh, H.2
  • 49
    • 79956197923 scopus 로고    scopus 로고
    • Voltammetric determination of isoproterenol using multiwall carbon nanotubes-ionic liquid paste electrode
    • A.A. Ensafi, and H. Karimi-Maleh Voltammetric determination of isoproterenol using multiwall carbon nanotubes-ionic liquid paste electrode Drug Test. Anal. 3 2011 325 330
    • (2011) Drug Test. Anal. , vol.3 , pp. 325-330
    • Ensafi, A.A.1    Karimi-Maleh, H.2
  • 50
    • 80052163394 scopus 로고    scopus 로고
    • Fabrication of a nanostructure-based electrochemical sensor for simultaneous determination of N-acetylcysteine and acetaminophen
    • H. Beitollahi, J.B. Raoof, and R. Hosseinzadeh Fabrication of a nanostructure-based electrochemical sensor for simultaneous determination of N-acetylcysteine and acetaminophen Talanta 85 2011 2128 2134
    • (2011) Talanta , vol.85 , pp. 2128-2134
    • Beitollahi, H.1    Raoof, J.B.2    Hosseinzadeh, R.3
  • 51
    • 54549113181 scopus 로고    scopus 로고
    • Carbon paste electrode incorporating 1-[4-(ferrocenyl ethynyl) phenyl]-1-ethanone for electrocatalytic and voltammetric determination of tryptophan
    • J.B. Raoof, R. Ojani, and H. Karimi-Maleh Carbon paste electrode incorporating 1-[4-(ferrocenyl ethynyl) phenyl]-1-ethanone for electrocatalytic and voltammetric determination of tryptophan Electroanalysis 20 2008 1259 1262
    • (2008) Electroanalysis , vol.20 , pp. 1259-1262
    • Raoof, J.B.1    Ojani, R.2    Karimi-Maleh, H.3
  • 52
    • 79957813422 scopus 로고    scopus 로고
    • Simultaneous determination of N-acetylcysteine and acetaminophen by voltammetric method using N-(3,4-dihydroxyphenethyl)-3,5-dinitrobenzamide modified multiwall carbon nanotubes paste electrode
    • A.A. Ensafi, H. Karimi-Maleh, S. Mallakpour, and M. Hatami Simultaneous determination of N-acetylcysteine and acetaminophen by voltammetric method using N-(3,4-dihydroxyphenethyl)-3,5-dinitrobenzamide modified multiwall carbon nanotubes paste electrode Sens. Actuators B 155 2011 464 472
    • (2011) Sens. Actuators B , vol.155 , pp. 464-472
    • Ensafi, A.A.1    Karimi-Maleh, H.2    Mallakpour, S.3    Hatami, M.4
  • 55
    • 79960402401 scopus 로고    scopus 로고
    • Highly sensitive voltammetric sensor based on catechol-derivative- multiwall carbon nanotubes for the catalytic determination of captopril in patient human urine samples
    • A.A. Ensafi, H. Karimi-Maleh, S. Mallakpour, and B. Rezaei Highly sensitive voltammetric sensor based on catechol-derivative-multiwall carbon nanotubes for the catalytic determination of captopril in patient human urine samples Coll. Surf. B 87 2011 480 488
    • (2011) Coll. Surf. B , vol.87 , pp. 480-488
    • Ensafi, A.A.1    Karimi-Maleh, H.2    Mallakpour, S.3    Rezaei, B.4
  • 56
    • 84861895011 scopus 로고    scopus 로고
    • Voltammetric determination of glutathione in haemolysed erythrocyte and tablet samples using modified-multiwall carbon nanotubes paste electrode
    • 10.1002/dta.347
    • A.A. Ensafi, S. Dadkhah-Tehrani, and H. Karimi-Maleh Voltammetric determination of glutathione in haemolysed erythrocyte and tablet samples using modified-multiwall carbon nanotubes paste electrode Drug Test. Anal. 2011 10.1002/dta.347
    • (2011) Drug Test. Anal.
    • Ensafi, A.A.1    Dadkhah-Tehrani, S.2    Karimi-Maleh, H.3
  • 57
    • 37349041639 scopus 로고    scopus 로고
    • Enhanced oxidation of diclofenac sodium at a nano-structured electrochemical sensing film constructed by multi-wall carbon nanotubes-surfactant composite
    • X. Yang, F. Wang, and S. Hu Enhanced oxidation of diclofenac sodium at a nano-structured electrochemical sensing film constructed by multi-wall carbon nanotubes-surfactant composite Mater. Sci. Eng. C 28 2008 188 194
    • (2008) Mater. Sci. Eng. C , vol.28 , pp. 188-194
    • Yang, X.1    Wang, F.2    Hu, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.