메뉴 건너뛰기




Volumn 103, Issue 3, 2012, Pages 322-326

Residual setup errors caused by rotation and non-rigid motion in prone-treated cervical cancer patients after online CBCT image-guidance

Author keywords

Cervix cancer; Cone beam CT; IGRT; Non rigid motion; Radiotherapy; Set up error

Indexed keywords

ADULT; AGED; ARTICLE; BODY POSTURE; CANCER PATIENT; CANCER RADIOTHERAPY; CLINICAL ARTICLE; CONE BEAM COMPUTED TOMOGRAPHY; EXTERNAL BEAM RADIOTHERAPY; FEMALE; HUMAN; LUMBAR SPINE; MEDICAL ERROR; MULTIDETECTOR COMPUTED TOMOGRAPHY; PATIENT POSITIONING; PELVIS; PRIORITY JOURNAL; ROTATION; SPINE MOBILITY; TREATMENT PLANNING; UTERINE CERVIX CANCER;

EID: 84861819060     PISSN: 01678140     EISSN: 18790887     Source Type: Journal    
DOI: 10.1016/j.radonc.2012.04.013     Document Type: Article
Times cited : (26)

References (23)
  • 1
    • 0023000608 scopus 로고
    • A prospective study of treatment techniques to minimize the volume of pelvic small bowel with reduction of acute and late effects associated with pelvic irradiation
    • M.J. Gallagher, H.D. Brereton, and R.A. Rostock A prospective study of treatment techniques to minimize the volume of pelvic small bowel with reduction of acute and late effects associated with pelvic irradiation Int J Radiat Oncol Biol Phys 12 1986 1565 1573
    • (1986) Int J Radiat Oncol Biol Phys , vol.12 , pp. 1565-1573
    • Gallagher, M.J.1    Brereton, H.D.2    Rostock, R.A.3
  • 2
    • 0020511020 scopus 로고
    • The avoidance of small intestine injury in gynecologic cancer
    • N. Green The avoidance of small intestine injury in gynecologic cancer Int J Radiat Oncol Biol Phys 9 1983 1385 1390
    • (1983) Int J Radiat Oncol Biol Phys , vol.9 , pp. 1385-1390
    • Green, N.1
  • 3
    • 0024558567 scopus 로고
    • Carcinoma of the cervix: Analysis of bladder and rectal radiation dose and complications
    • G.S. Montana, and W.C. Fowler Carcinoma of the cervix: analysis of bladder and rectal radiation dose and complications Int J Radiat Oncol Biol Phys 16 1989 95 100
    • (1989) Int J Radiat Oncol Biol Phys , vol.16 , pp. 95-100
    • Montana, G.S.1    Fowler, W.C.2
  • 4
    • 0032980852 scopus 로고    scopus 로고
    • Radiation therapy morbidity in carcinoma of the uterine cervix: Dosimetric and clinical correlation
    • C. Perez, P. Grigsby, M. Lockett, K. Chao, and J. Williamson Radiation therapy morbidity in carcinoma of the uterine cervix: dosimetric and clinical correlation Int J Radiat Oncol Biol Phys 44 1999 855 866
    • (1999) Int J Radiat Oncol Biol Phys , vol.44 , pp. 855-866
    • Perez, C.1    Grigsby, P.2    Lockett, M.3    Chao, K.4    Williamson, J.5
  • 5
    • 0032871479 scopus 로고    scopus 로고
    • Impact of the filling status of the bladder and rectum on their integral dose distribution and the movement of the uterus in the treatment planning of gynaecological cancer
    • A. Buchali, S. Koswig, and S. Dinges Impact of the filling status of the bladder and rectum on their integral dose distribution and the movement of the uterus in the treatment planning of gynaecological cancer Radiother Oncol 52 1999 29 34
    • (1999) Radiother Oncol , vol.52 , pp. 29-34
    • Buchali, A.1    Koswig, S.2    Dinges, S.3
  • 6
    • 0030826232 scopus 로고    scopus 로고
    • Efficacy of a belly board device with CT-simulation in reducing small bowel volume within pelvic irradiation fields
    • I.J. Das, R.M. Lanciano, B. Movsas, K. Kagawa, and S.J. Barnes Efficacy of a belly board device with CT-simulation in reducing small bowel volume within pelvic irradiation fields Int J Radiat Oncol Biol Phys 39 1997 67 76
    • (1997) Int J Radiat Oncol Biol Phys , vol.39 , pp. 67-76
    • Das, I.J.1    Lanciano, R.M.2    Movsas, B.3    Kagawa, K.4    Barnes, S.J.5
  • 7
    • 0038642531 scopus 로고    scopus 로고
    • The relationship between belly board position and patient anatomy and its influence on dose-volume histogram of small bowel for postoperative radiotherapy of rectal cancer
    • O. Koelbl, D. Vordermark, and M. Flentje The relationship between belly board position and patient anatomy and its influence on dose-volume histogram of small bowel for postoperative radiotherapy of rectal cancer Radiother Oncol 67 2003 345 349
    • (2003) Radiother Oncol , vol.67 , pp. 345-349
    • Koelbl, O.1    Vordermark, D.2    Flentje, M.3
  • 8
    • 14844315092 scopus 로고    scopus 로고
    • Treatment with a belly-board device significantly reduces the volume of small bowel irradiated and results in low acute toxicity in adjuvant radiotherapy for gynecologic cancer: Results of a prospective study
    • J. Martin, K. Fitzpatrick, and G. Horan Treatment with a belly-board device significantly reduces the volume of small bowel irradiated and results in low acute toxicity in adjuvant radiotherapy for gynecologic cancer: results of a prospective study Radiother Oncol 74 2005 267 274
    • (2005) Radiother Oncol , vol.74 , pp. 267-274
    • Martin, J.1    Fitzpatrick, K.2    Horan, G.3
  • 9
    • 28044467495 scopus 로고    scopus 로고
    • Variation of small bowel sparing with small bowel displacement system according to the physiological status of the bladder during radiotherapy for cervical cancer
    • W. Park, S.J. Huh, and J.E. Lee Variation of small bowel sparing with small bowel displacement system according to the physiological status of the bladder during radiotherapy for cervical cancer Gynecol Oncol 99 2005 645 651
    • (2005) Gynecol Oncol , vol.99 , pp. 645-651
    • Park, W.1    Huh, S.J.2    Lee, J.E.3
  • 10
    • 0026570956 scopus 로고
    • A review of electronic portal imaging devices (EPIDs)
    • A.L. Boyer, L. Antonuk, and A. Fenster A review of electronic portal imaging devices (EPIDs) Med Phys 19 1992 1 16
    • (1992) Med Phys , vol.19 , pp. 1-16
    • Boyer, A.L.1    Antonuk, L.2    Fenster, A.3
  • 12
    • 0035283667 scopus 로고    scopus 로고
    • Analysis and reduction of 3D systematic and random setup errors during the simulation and treatment of lung cancer patients with CT-based external beam radiotherapy dose planning
    • H.C.J. de Boer, J. van Sörnsen de Koste, S. Senan, A.G. Visser, and B.J.M. Heijmen Analysis and reduction of 3D systematic and random setup errors during the simulation and treatment of lung cancer patients with CT-based external beam radiotherapy dose planning Int J Radiat Oncol Biol Phys 49 2001 857 868
    • (2001) Int J Radiat Oncol Biol Phys , vol.49 , pp. 857-868
    • De Boer, H.C.J.1    Van Sörnsen De Koste, J.2    Senan, S.3    Visser, A.G.4    Heijmen, B.J.M.5
  • 13
    • 55149085938 scopus 로고    scopus 로고
    • Inter-fraction bladder filling variations and time trends for cervical cancer patients assessed with a portable 3-dimensional ultrasound bladder scanner
    • R. Ahmad, M.S. Hoogeman, S. Quint, J.W. Mens, I. de Pree, and B.J.M. Heijmen Inter-fraction bladder filling variations and time trends for cervical cancer patients assessed with a portable 3-dimensional ultrasound bladder scanner Radiother Oncol 89 2008 172 179
    • (2008) Radiother Oncol , vol.89 , pp. 172-179
    • Ahmad, R.1    Hoogeman, M.S.2    Quint, S.3    Mens, J.W.4    De Pree, I.5    Heijmen, B.J.M.6
  • 14
    • 33847306482 scopus 로고    scopus 로고
    • Positioning accuracy of cone-beam computed tomography in combination with a HexaPOD robot treatment table
    • J. Meyer, J. Wilbert, and K. Baier Positioning accuracy of cone-beam computed tomography in combination with a HexaPOD robot treatment table Int J Radiat Oncol Biol Phys 67 2007 1220 1228
    • (2007) Int J Radiat Oncol Biol Phys , vol.67 , pp. 1220-1228
    • Meyer, J.1    Wilbert, J.2    Baier, K.3
  • 15
    • 0030067570 scopus 로고    scopus 로고
    • A grey-level image alignment algorithm for registration of portal images and digitally reconstructed radiographs
    • D.H. Hristov, and B.G. Fallone A grey-level image alignment algorithm for registration of portal images and digitally reconstructed radiographs Med Phys 23 1996 75 84
    • (1996) Med Phys , vol.23 , pp. 75-84
    • Hristov, D.H.1    Fallone, B.G.2
  • 16
    • 79952439850 scopus 로고    scopus 로고
    • Increasing treatment accuracy for cervical cancer patients using correlations between bladder-filling change and cervix-uterus displacements: Proof of principle
    • R. Ahmad, M.S. Hoogeman, and M. Bondar Increasing treatment accuracy for cervical cancer patients using correlations between bladder-filling change and cervix-uterus displacements: proof of principle Radiother Oncol 98 2011 340 346
    • (2011) Radiother Oncol , vol.98 , pp. 340-346
    • Ahmad, R.1    Hoogeman, M.S.2    Bondar, M.3
  • 17
    • 79958170380 scopus 로고    scopus 로고
    • Toward an individualized target motion management for IMRT of cervical cancer based on model-predicted
    • L. Bondar, M.S. Hoogeman, J.W. Mens, G. Dhawtal, I. de Pree, and R. Ahmad Toward an individualized target motion management for IMRT of cervical cancer based on model-predicted Radiother Oncol 99 2011 240 245
    • (2011) Radiother Oncol , vol.99 , pp. 240-245
    • Bondar, L.1    Hoogeman, M.S.2    Mens, J.W.3    Dhawtal, G.4    De Pree, I.5    Ahmad, R.6
  • 18
    • 75149127710 scopus 로고    scopus 로고
    • Rotation of the sacrum during bellyboard pelvic radiotherapy
    • M. Kasabasic, D. Faj, A. Ivkovic, S. Jurkovic, and N. Belaj Rotation of the sacrum during bellyboard pelvic radiotherapy Med Dosim 35 2010 28 30
    • (2010) Med Dosim , vol.35 , pp. 28-30
    • Kasabasic, M.1    Faj, D.2    Ivkovic, A.3    Jurkovic, S.4    Belaj, N.5
  • 19
    • 51049099181 scopus 로고    scopus 로고
    • Image-guidance protocol comparison: Supine and prone setup accuracy for pelvic radiation therapy
    • F. Siddiqui, C. Shi, N. Papanikolaou, and M. Fuss Image-guidance protocol comparison: supine and prone setup accuracy for pelvic radiation therapy Acta Oncol 47 2008 1344 1350
    • (2008) Acta Oncol , vol.47 , pp. 1344-1350
    • Siddiqui, F.1    Shi, C.2    Papanikolaou, N.3    Fuss, M.4
  • 20
    • 84861819513 scopus 로고    scopus 로고
    • Residual rotational setup errors after daily cone-beam CT image guidance in locally advanced cervical cancer (poster) Physics and technology: Adaptive and image/dose guided RT
    • L.V. Laursen, L.P. Muren, and U.V. Etstrern Residual rotational setup errors after daily cone-beam CT image guidance in locally advanced cervical cancer (poster) Physics and technology: adaptive and image/dose guided RT Radiother Oncol 96 2010 S419 S444
    • (2010) Radiother Oncol , vol.96
    • Laursen, L.V.1    Muren, L.P.2    Etstrern, U.V.3
  • 21
    • 0035313822 scopus 로고    scopus 로고
    • Reduction of irradiated small bowel volume and accurate patient positioning by use of a bellyboard device in pelvic radiotherapy of gynecological cancer patients
    • M. Olofsen-van Acht, H. van den Berg, and S. Quint Reduction of irradiated small bowel volume and accurate patient positioning by use of a bellyboard device in pelvic radiotherapy of gynecological cancer patients Radiother Oncol 59 2001 87 93
    • (2001) Radiother Oncol , vol.59 , pp. 87-93
    • Olofsen-Van Acht, M.1    Van Den Berg, H.2    Quint, S.3
  • 22
    • 84861810501 scopus 로고    scopus 로고
    • Combined use of bellyboard and IMRT results in maximal small bowel sparing in rectal cancer radiotherapy
    • R. Sripadam, J. Stratford, and M. Duffy Combined use of bellyboard and IMRT results in maximal small bowel sparing in rectal cancer radiotherapy Int J Radiat Oncol Biol Phys 75 2009 S292
    • (2009) Int J Radiat Oncol Biol Phys , vol.75 , pp. 292
    • Sripadam, R.1    Stratford, J.2    Duffy, M.3
  • 23
    • 34247892507 scopus 로고    scopus 로고
    • Kilo-voltage cone-beam computed tomography setup measurements for lung cancer patients; First clinical results and comparison with electronic portal-imaging device
    • G.R. Borst, J.J. Sonke, A. Betgen, P. Remeijer, M. van Herk, and J.V. Lebesque Kilo-voltage cone-beam computed tomography setup measurements for lung cancer patients; first clinical results and comparison with electronic portal-imaging device Int J Radiat Oncol Biol Phys 68 2007 555 561
    • (2007) Int J Radiat Oncol Biol Phys , vol.68 , pp. 555-561
    • Borst, G.R.1    Sonke, J.J.2    Betgen, A.3    Remeijer, P.4    Van Herk, M.5    Lebesque, J.V.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.