메뉴 건너뛰기




Volumn 23, Issue 1, 1996, Pages 75-84

A grey-level image alignment algorithm for registration of portal images and digitally reconstructed radiographs

Author keywords

[No Author keywords available]

Indexed keywords

FAST FOURIER TRANSFORMS; PATIENT TREATMENT; RADIOGRAPHY;

EID: 0030067570     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.597743     Document Type: Article
Times cited : (59)

References (23)
  • 2
    • 0027278542 scopus 로고
    • An automatic in-line inspection of patient setup in radiation therapy using digital portal images
    • K. Gilhuis and M. van Herk. "An automatic in-line inspection of patient setup in radiation therapy using digital portal images," Med. Phys. 20, 667-677 (1993).
    • (1993) Med. Phys. , vol.20 , pp. 667-677
    • Gilhuis, K.1    Van Herk, M.2
  • 3
    • 0028091334 scopus 로고
    • A robust morphological algorithm for automatic extraction and correlation of portal images
    • H. Wang and B. G. Fallone, "A robust morphological algorithm for automatic extraction and correlation of portal images," Med. Phys. 21, 237-244 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 237-244
    • Wang, H.1    Fallone, B.G.2
  • 4
    • 0028149370 scopus 로고
    • A robust method of multileaf collimator (MLC) leaf-configuration verification
    • S. Zhou and L. Verhey, "A robust method of multileaf collimator (MLC) leaf-configuration verification," Phys. Med. Biol. 39, 1929-1948 (1994).
    • (1994) Phys. Med. Biol. , vol.39 , pp. 1929-1948
    • Zhou, S.1    Verhey, L.2
  • 5
    • 0028795798 scopus 로고
    • Segmented chamfer matching for prescription-treatment image registration in radiotherapy
    • K. W. Leszczynski, S. Loose, and P. Dunscombe, "Segmented chamfer matching for prescription-treatment image registration in radiotherapy," Phys. Med. Biol. 40, 83-94 (1995).
    • (1995) Phys. Med. Biol. , vol.40 , pp. 83-94
    • Leszczynski, K.W.1    Loose, S.2    Dunscombe, P.3
  • 6
    • 0025191363 scopus 로고
    • A method for the measurement of field placement errors in digital portal images
    • H Meertens, J. Bijhold, and J. Strackee, "A method for the measurement of field placement errors in digital portal images," Phys. Med. Biol. 35, 299-323 (1990).
    • (1990) Phys. Med. Biol. , vol.35 , pp. 299-323
    • Meertens, H.1    Bijhold, J.2    Strackee, J.3
  • 7
    • 0028260271 scopus 로고
    • A semiautomatic method for registration of portal images
    • J. Moseley and P. Munro, "A semiautomatic method for registration of portal images," Med. Phys. 21, 551-558 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 551-558
    • Moseley, J.1    Munro, P.2
  • 8
    • 0026652740 scopus 로고
    • Correlation of projection radiographs in radiation therapy using open curve segments and points
    • J. Balter, C. Pellzzare, and G. Chen, "Correlation of projection radiographs in radiation therapy using open curve segments and points," Med. Phys. 19, 329-334 (1992).
    • (1992) Med. Phys. , vol.19 , pp. 329-334
    • Balter, J.1    Pellzzare, C.2    Chen, G.3
  • 9
    • 0025836884 scopus 로고
    • Investigation of an FFT-based correlation technique for verification of radiation treatment setup
    • S. Jones and A. Boyer, "Investigation of an FFT-based correlation technique for verification of radiation treatment setup," Med. Phys. 18, 1116-1125 (1992).
    • (1992) Med. Phys. , vol.18 , pp. 1116-1125
    • Jones, S.1    Boyer, A.2
  • 10
    • 0028236004 scopus 로고
    • Pseudocorrelation: A fast, robust, absolute grey-level image alignment algorithm
    • T. Radcliffe, R. Rajapakshe, and S. Shalev, "Pseudocorrelation: A fast, robust, absolute grey-level image alignment algorithm," Med. Phys. 21, 761-769 (1992).
    • (1992) Med. Phys. , vol.21 , pp. 761-769
    • Radcliffe, T.1    Rajapakshe, R.2    Shalev, S.3
  • 13
    • 58149413803 scopus 로고
    • Photon cross sections from 1 KeV to 100 MeV for elements Z=1 to Z=100
    • E. Storm and H. Israel, "Photon cross sections from 1 KeV to 100 MeV for elements Z=1 to Z=100," Nucl Data Tables A 7, 565-681 (1970).
    • (1970) Nucl Data Tables A , vol.7 , pp. 565-681
    • Storm, E.1    Israel, H.2
  • 14
    • 0025273449 scopus 로고
    • Computation of digitally reconstructed radiographs for use in radiotherapy treatment design
    • G. Sherouse, K. Novins, and E. Shaney, "Computation of digitally reconstructed radiographs for use in radiotherapy treatment design," Int. J. Radiat. Oncol. Biol. Phys. 17, 651-658 (1990).
    • (1990) Int. J. Radiat. Oncol. Biol. Phys. , vol.17 , pp. 651-658
    • Sherouse, G.1    Novins, K.2    Shaney, E.3
  • 15
    • 0021952059 scopus 로고
    • Fast calculation of the exact radiological path for a three-dimensional CT array
    • B. Siddon, "Fast calculation of the exact radiological path for a three-dimensional CT array," Med. Phys. 12, 252-255 (1985).
    • (1985) Med. Phys. , vol.12 , pp. 252-255
    • Siddon, B.1
  • 20
    • 0028420177 scopus 로고
    • Medical image registration using knowledge of adjacency of anatomical structures
    • D. L. G. Hill and D. J. Hawkes, "Medical image registration using knowledge of adjacency of anatomical structures," Image Vision Comput. 12, 173-178 (1994)
    • (1994) Image Vision Comput. , vol.12 , pp. 173-178
    • Hill, D.L.G.1    Hawkes, D.J.2
  • 22
    • 0027996228 scopus 로고
    • A patient-to-computed-tomography image registration method based on digitally reconstructed radiographs
    • L. Lemieux, R. Jagot, D. Fish, N. Kitchen, and D. Thomas, "A patient-to-computed-tomography image registration method based on digitally reconstructed radiographs," Med. Phys. 21, 1749-1760 (1994).
    • (1994) Med. Phys. , vol.21 , pp. 1749-1760
    • Lemieux, L.1    Jagot, R.2    Fish, D.3    Kitchen, N.4    Thomas, D.5
  • 23
    • 84955049245 scopus 로고
    • Anatomical-functional correlative analysis of the human brain using three dimensional imaging systems
    • A. C. Evans, S. Marett, L. Coiling, and T. M Peters, "Anatomical-functional correlative analysis of the human brain using three dimensional imaging systems," Proc. SPIE Med. Image. II, Image Process. 1092, 264-270 (1989).
    • (1989) Proc. SPIE Med. Image. II, Image Process , vol.1092 , pp. 264-270
    • Evans, A.C.1    Marett, S.2    Coiling, L.3    Peters, T.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.