메뉴 건너뛰기




Volumn 39, Issue 5, 2012, Pages 2346-2358

Development and evaluation of an improved quantitative 90Y bremsstrahlung SPECT method

Author keywords

model based compensation; Monte Carlo simulation; quantitative SPECT; targeted radionuclide therapy; Yttrium 90 bremsstrahlung

Indexed keywords

ELECTROMAGNETIC WAVES; ERRORS; IMAGE SEGMENTATION; ITERATIVE METHODS; MAXIMUM PRINCIPLE; PARTICLE BEAMS; PHANTOMS; PHOTONS; RADIOISOTOPES; SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY; TURBULENT FLOW;

EID: 84861638196     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3700174     Document Type: Article
Times cited : (116)

References (24)
  • 2
    • 47749131571 scopus 로고    scopus 로고
    • Three-dimensional imaging-based radiobiological dosimetry
    • DOI 10.1053/j.semnuclmed.2008.05.008, PII S0001299808000755
    • G. Sgouros, E. Frey, R. Wahl, B. He, A. Prideaux, and R. Hobbs, Three-dimensional imaging-based radiobiological dosimetry., Semin. Nucl. Med. 38, 321-334 (2008). 10.1053/j.semnuclmed.2008.05.008 (Pubitemid 352033565)
    • (2008) Seminars in Nuclear Medicine , vol.38 , Issue.5 , pp. 321-334
    • Sgouros, G.1    Frey, E.2    Wahl, R.3    He, B.4    Prideaux, A.5    Hobbs, R.6
  • 3
    • 79961045223 scopus 로고    scopus 로고
    • Recommendations of the American Association of Physicists in Medicine on dosimetry, imaging, and quality assurance procedures for (90)Y microsphere brachytherapy in the treatment of hepatic malignancies
    • 10.1118/1.3608909
    • W. A. Dezarn, J. T. Cessna, L. A. DeWerd, W. Z. Feng, V. L. Gates, J. Halama, A. S. Kennedy, S. Nag, M. Sarfaraz, V. Sehgal, R. Selwyn, M. G. Stabin, B. R. Thomadsen, L. E. Williams, and R. Salem, Recommendations of the American Association of Physicists in Medicine on dosimetry, imaging, and quality assurance procedures for (90)Y microsphere brachytherapy in the treatment of hepatic malignancies., Med. Phys. 38, 4824-4845 (2011). 10.1118/1.3608909
    • (2011) Med. Phys. , vol.38 , pp. 4824-4845
    • Dezarn, W.A.1    Cessna, J.T.2    Dewerd, L.A.3    Feng, W.Z.4    Gates, V.L.5    Halama, J.6    Kennedy, A.S.7    Nag, S.8    Sarfaraz, M.9    Sehgal, V.10    Selwyn, R.11    Stabin, M.G.12    Thomadsen, B.R.13    Williams, L.E.14    Salem, R.15
  • 5
    • 34247510563 scopus 로고    scopus 로고
    • Concordant F-18 FDG PET and Y-90 Bremsstrahlung scans depict selective delivery of Y-90-microspheres to liver tumors: Confirmation with histopathology
    • DOI 10.1097/01.rlu.0000259568.54976.bd, PII 0000307220070500000006
    • A. Al-Nahhas, N. Tehranipour, R. Canelo, G. Stamp, K. Woo, P. Tait, and P. Gishen, Concordant F-18FDG PET and Y-90 bremsstrahlung scans depict selective delivery of Y-90-microspheres to liver tumors: Confirmation with histopathology., Clin. Nucl. Med. 32, 371-374 (2007). 10.1097/01.rlu.0000259568. 54976.bd (Pubitemid 46659171)
    • (2007) Clinical Nuclear Medicine , vol.32 , Issue.5 , pp. 371-374
    • Tehranipour, N.1    Al-Nahhas, A.2    Canelo, R.3    Stamp, G.4    Woo, K.5    Tait, P.6    Gishen, P.7
  • 7
    • 58149235038 scopus 로고    scopus 로고
    • Evaluation of quantitative (90) y SPECT based on experimental phantom studies
    • 10.1088/0031-9155/53/20/008
    • D. Minarik, K. Sjogreen Gleisner, and M. Ljungberg, Evaluation of quantitative (90) Y SPECT based on experimental phantom studies., Phys. Med. Biol. 53, 5689-5703 (2008). 10.1088/0031-9155/53/20/008
    • (2008) Phys. Med. Biol. , vol.53 , pp. 5689-5703
    • Minarik, D.1    Sjogreen Gleisner, K.2    Ljungberg, M.3
  • 8
    • 0030348470 scopus 로고    scopus 로고
    • A new method for modeling the spatially-variant, object-dependent scatter response function in SPECT
    • Vol. (IEEE, Anaheim, CA)
    • E. C. Frey and B. M. W. Tsui, A new method for modeling the spatially-variant, object-dependent scatter response function in SPECT., IEEE Nuclear Science Symposium, Vol. 2 (IEEE, Anaheim, CA, 1996), pp. 1082-1086.
    • (1996) IEEE Nuclear Science Symposium , vol.2 , pp. 1082-1086
    • Frey, E.C.1    Tsui, B.M.W.2
  • 9
    • 0021327145 scopus 로고
    • EM reconstruction algorithms for emission and transmission tomography
    • K. Lange and R. Carson, EM reconstruction algorithms for emission and transmission tomography., J. Comput. Assist. Tomogr. 8, 306-316 (1984). (Pubitemid 14169679)
    • (1984) Journal of Computer Assisted Tomography , vol.8 , Issue.2 , pp. 306-316
    • Lange, K.1    Carson, R.2
  • 10
    • 0028700063 scopus 로고
    • Accelerated image-reconstruction using ordered subsets of projection data
    • 10.1109/42.363108
    • H. M. Hudson and R. S. Larkin, Accelerated image-reconstruction using ordered subsets of projection data., IEEE Trans. Med. Imaging 13, 601-609 (1994). 10.1109/42.363108
    • (1994) IEEE Trans. Med. Imaging , vol.13 , pp. 601-609
    • Hudson, H.M.1    Larkin, R.S.2
  • 11
    • 0024713937 scopus 로고
    • Monte Carlo program for the simulation of scintillation camera characteristics
    • DOI 10.1016/0169-2607(89)90111-9
    • M. Ljungberg and S.-E. Strand, A Monte Carlo program for the simulation of scintillation camera characteristics., Comput. Methods Programs Biomed. 29, 257-272 (1989). 10.1016/0169-2607(89)90111-9 (Pubitemid 20610320)
    • (1989) Computer Methods and Programs in Biomedicine , vol.29 , Issue.4 , pp. 257-272
    • Ljungberg Michael1    Strand Sven-Erik2
  • 12
    • 76149088572 scopus 로고    scopus 로고
    • (Los Alamos National Laboratory, Los Alamos)
    • J. S. Hendricks, mcnpx (Los Alamos National Laboratory, Los Alamos, 2005).
    • (2005) Mcnpx
    • Hendricks, J.S.1
  • 13
    • 77953509963 scopus 로고    scopus 로고
    • Fast simulation of yttrium-90 bremsstrahlung photons with GATE
    • R. Van Holen, J. De Beenhouwer, and, 10.1118/1.3431998
    • E. Rault, S. Staelens, R. Van Holen, J. De Beenhouwer, and S. Vandenberghe, Fast simulation of yttrium-90 bremsstrahlung photons with GATE., Med. Phys. 37, 2943-2950 (2010). 10.1118/1.3431998
    • (2010) Med. Phys. , vol.37 , pp. 2943-2950
    • Rault, E.1    Staelens, S.2    Vandenberghe, S.3
  • 15
    • 77956299682 scopus 로고    scopus 로고
    • 4D XCAT phantom for multimodality imaging research
    • 10.1118/1.3480985
    • W. P. Segars, G. Sturgeon, S. Mendonca, J. Grimes, and B. M. W. Tsui, 4D XCAT phantom for multimodality imaging research., Med. Phys. 37, 4902-4915 (2010). 10.1118/1.3480985
    • (2010) Med. Phys. , vol.37 , pp. 4902-4915
    • Segars, W.P.1    Sturgeon, G.2    Mendonca, S.3    Grimes, J.4    Tsui, B.M.W.5
  • 16
    • 0036624469 scopus 로고    scopus 로고
    • Parameterization of Pb X-ray contamination in simultaneous Tl-201 and Tc-99m dual-isotope imaging
    • DOI 10.1109/TNS.2002.1039549, PII S0018949902061828
    • W. T. Wang, E. C. Frey, B. M. W. Tsui, C. Tocharoenchai, and W. H. Baird, Parameterization of Pb c-ray contamination in simultaneous Tl-201 and Tc-99m dual-isotope imaging., IEEE Trans. Nucl. Sci. 49, 680-692 (2002). 10.1109/TNS.2002.1039549 (Pubitemid 35311887)
    • (2002) IEEE Transactions on Nuclear Science , vol.49 , Issue.3 , pp. 680-692
    • Wang, W.-T.1    Frey, E.C.2    Tsui, B.M.W.3    Tocharoenchai, C.4    Baird, W.H.5
  • 17
    • 0028727372 scopus 로고
    • A Rotating and warping projector backprojector for fan-beam and cone-beam iterative algorithm
    • 10.1109/23.340651
    • G. L. Zeng, Y. L. Hsieh, and G. T. Gullberg, A Rotating and warping projector backprojector for fan-beam and cone-beam iterative algorithm., IEEE Trans. Nucl. Sci. 41, 2807-2811 (1994). 10.1109/23.340651
    • (1994) IEEE Trans. Nucl. Sci. , vol.41 , pp. 2807-2811
    • Zeng, G.L.1    Hsieh, Y.L.2    Gullberg, G.T.3
  • 18
    • 0027649213 scopus 로고
    • A fast projector-backprojector pair modeling the asymmetric, spatially varying scatter response function for scatter compensation in SPECT imaging
    • 10.1109/23.256735
    • E. C. Frey, Z. W. Ju, and B. M. W. Tsui, A fast projector-backprojector pair modeling the asymmetric, spatially varying scatter response function for scatter compensation in SPECT imaging., IEEE Trans. Nucl. Sci. 40, 1192-1197 (1993). 10.1109/23.256735
    • (1993) IEEE Trans. Nucl. Sci. , vol.40 , pp. 1192-1197
    • Frey, E.C.1    Ju, Z.W.2    Tsui, B.M.W.3
  • 19
    • 0031951077 scopus 로고    scopus 로고
    • Dual matrix ordered subsets reconstruction for accelerated 3D scatter compensation in single-photon emission tomography
    • DOI 10.1007/s002590050188
    • C. Kamphuis, F. J. Beekman, P. P. van Rijk, and M. A. Viergever, Dual matrix ordered subsets reconstruction for accelerated 3D scatter compensation in single-photon emission tomography., Eur. J. Nucl. Med. 25, 8-18 (1998). 10.1007/s002590050188 (Pubitemid 28107898)
    • (1998) European Journal of Nuclear Medicine , vol.25 , Issue.1 , pp. 8-18
    • Kamphuis, C.1    Beekman, F.J.2    Van Rijk, P.P.3    Viergever, M.A.4
  • 20
    • 0034178294 scopus 로고    scopus 로고
    • Unmatched projector/backprojector pairs in an iterative reconstruction algorithm
    • 10.1109/42.870265
    • G. L. Zeng and G. T. Gullberg, Unmatched projector/backprojector pairs in an iterative reconstruction algorithm., IEEE Trans. Med. Imaging 19, 548-555 (2000). 10.1109/42.870265
    • (2000) IEEE Trans. Med. Imaging , vol.19 , pp. 548-555
    • Zeng, G.L.1    Gullberg, G.T.2
  • 22
    • 1342308195 scopus 로고    scopus 로고
    • 90Y using commercial radionuclide calibrators
    • DOI 10.1016/j.apradiso.2003.11.068
    • B. E. Zimmerman, J. T. Cessna, and M. A. Millican, Experimental determination of calibration settings for plastic syringes containing solutions of Y-90 using commercial radionuclide calibrators., Appl. Radiat. Isot. 60, 511-517 (2004). 10.1016/j.apradiso.2003.11.068 (Pubitemid 38264143)
    • (2004) Applied Radiation and Isotopes , vol.60 , Issue.2-4 , pp. 511-517
    • Zimmerman, B.E.1    Cessna, J.T.2    Millican, M.A.3
  • 23
    • 23844500693 scopus 로고    scopus 로고
    • Partial volume effect compensation for quantitative brain SPECT imaging
    • DOI 10.1109/TMI.2005.850547
    • Y. Du, B. M. W. Tsui, and E. C. Frey, Partial volume effect compensation for quantitative brain SPECT imaging., IEEE Trans. Med. Imaging 24, 969-976 (2005). 10.1109/TMI.2005.850547 (Pubitemid 41178498)
    • (2005) IEEE Transactions on Medical Imaging , vol.24 , Issue.8 , pp. 969-976
    • Du, Y.1    Tsui, B.M.W.2    Frey, E.C.3
  • 24
    • 79958806596 scopus 로고    scopus 로고
    • Development and evaluation of a model-based downscatter compensation method for quantitative I-131 SPECT
    • 10.1118/1.3590382
    • N. Song, Y. Du, B. He, and E. C. Frey, Development and evaluation of a model-based downscatter compensation method for quantitative I-131 SPECT., Med. Phys. 38, 3193-3204 (2011). 10.1118/1.3590382
    • (2011) Med. Phys. , vol.38 , pp. 3193-3204
    • Song, N.1    Du, Y.2    He, B.3    Frey, E.C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.