메뉴 건너뛰기




Volumn 24, Issue 8, 2005, Pages 969-976

Partial volume effect compensation for quantitative brain SPECT imaging

Author keywords

Brain SPECT imaging; Partial volume effect compensation; Quantification

Indexed keywords

ALGORITHMS; ATTENUATION; BRAIN; COMPUTER SIMULATION; IMAGE ANALYSIS; IMAGE RECONSTRUCTION; ITERATIVE METHODS; MAGNETIC RESONANCE IMAGING; MONTE CARLO METHODS; PERTURBATION TECHNIQUES; POLYVINYL CHLORIDES; POSITRON EMISSION TOMOGRAPHY; RESTORATION;

EID: 23844500693     PISSN: 02780062     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMI.2005.850547     Document Type: Article
Times cited : (109)

References (34)
  • 1
    • 0034951186 scopus 로고    scopus 로고
    • In vivo imaging of neurotransmission: A new era for nuclear neuroimaging
    • A. M. Catafau, "In vivo imaging of neurotransmission: a new era for nuclear neuroimaging," Nucl. Med. Commun., vol. 22, pp. 817-818, 2001.
    • (2001) Nucl. Med. Commun. , vol.22 , pp. 817-818
    • Catafau, A.M.1
  • 3
    • 0033827106 scopus 로고    scopus 로고
    • Single photon emission tomography imaging in Parkinsonian disorders: A review
    • P. D. Acton and P. D. Mozley, "Single photon emission tomography imaging in Parkinsonian disorders: A review," Behav. Neurol., vol. 12, pp. 11-27, 2000.
    • (2000) Behav. Neurol. , vol.12 , pp. 11-27
    • Acton, P.D.1    Mozley, P.D.2
  • 4
    • 0034751501 scopus 로고    scopus 로고
    • Brain SPECT of dopaminergic neurotransmission: A new tool with proved clinical impact
    • A. M. Catafau, "Brain SPECT of dopaminergic neurotransmission: a new tool with proved clinical impact," Nucl. Med. Commun., vol. 22, pp. 1059-1060, 2001.
    • (2001) Nucl. Med. Commun. , vol.22 , pp. 1059-1060
    • Catafau, A.M.1
  • 5
    • 0018983328 scopus 로고
    • Physical factors affecting quantitative measurements using camera-based single photon emission computed tomography (SPECT)
    • R. J. Jaszczak, R. E. Coleman, and F. R. Whitehead, "Physical factors affecting quantitative measurements using camera-based single photon emission computed tomography (SPECT)," IEEE Trans. Nucl. Sci., vol. 28, pp. 69-80, 1981.
    • (1981) IEEE Trans. Nucl. Sci. , vol.28 , pp. 69-80
    • Jaszczak, R.J.1    Coleman, R.E.2    Whitehead, F.R.3
  • 6
    • 0029119748 scopus 로고
    • Quantitative SPECT imaging: A review and recommendations by the focus committee of the society of nuclear medicine computer and instrumentation council
    • M. S. Rosenthal, J. Cullom, W. Hawkins, S. C. Moore, B. M. W. Tsui, and M. Yester, "Quantitative SPECT imaging: a review and recommendations by the focus committee of the society of nuclear medicine computer and instrumentation council," J. Nucl. Med., vol. 36, pp. 1489-1513, 1995.
    • (1995) J. Nucl. Med. , vol.36 , pp. 1489-1513
    • Rosenthal, M.S.1    Cullom, J.2    Hawkins, W.3    Moore, S.C.4    Tsui, B.M.W.5    Yester, M.6
  • 7
    • 0031794902 scopus 로고
    • Special issues in quantitation of brain receptors and related markers by emission computed tomography
    • J. M. Links, "Special issues in quantitation of brain receptors and related markers by emission computed tomography," Quart. J. Nucl. Med., vol. 42, pp. 158-165, 1988.
    • (1988) Quart. J. Nucl. Med. , vol.42 , pp. 158-165
    • Links, J.M.1
  • 8
    • 0038315472 scopus 로고    scopus 로고
    • Contribution of scatter and attenuation compensation to SPECT images of nonuniformly distributed brain activities
    • K. M. Kim, A. Varrone, and H. Watabe et al., "Contribution of scatter and attenuation compensation to SPECT images of nonuniformly distributed brain activities," J. Nucl. Med., vol. 44, pp. 512-519, 2003.
    • (2003) J. Nucl. Med. , vol.44 , pp. 512-519
    • Kim, K.M.1    Varrone, A.2    Watabe, H.3
  • 9
    • 0032919168 scopus 로고    scopus 로고
    • Effects of scatter and attenuation correction on quantitative analysis of beta-CIT brain SPET
    • J. Hashimoto, T. Sasaki, and K. Ogawa et al., "Effects of scatter and attenuation correction on quantitative analysis of beta-CIT brain SPET," Nucl. Med. Commun., vol. 20, pp. 159-165, 1999.
    • (1999) Nucl. Med. Commun. , vol.20 , pp. 159-165
    • Hashimoto, J.1    Sasaki, T.2    Ogawa, K.3
  • 10
    • 0031907419 scopus 로고    scopus 로고
    • Effects of scatter and attenuation correction on quantitative assessment of regional cerebral blood flow with SPECT
    • H. Iida, Y. Narita, and H. Kado et al., "Effects of scatter and attenuation correction on quantitative assessment of regional cerebral blood flow with SPECT," J. Nucl. Med., vol. 39, pp. 181-189, 1998.
    • (1998) J. Nucl. Med. , vol.39 , pp. 181-189
    • Iida, H.1    Narita, Y.2    Kado, H.3
  • 11
    • 0031713523 scopus 로고    scopus 로고
    • Significance of nonuniform attenuation correction in quantitative brain SPECT imaging
    • N. Rajeevan, I. G. Zubal, S. Q. Ramsby, S.S. Zoghbi, J. Seibyl, and R. B. Innis, "Significance of nonuniform attenuation correction in quantitative brain SPECT imaging," J. Nucl. Med., vol. 39, pp. 1719-1726, 1998.
    • (1998) J. Nucl. Med. , vol.39 , pp. 1719-1726
    • Rajeevan, N.1    Zubal, I.G.2    Ramsby, S.Q.3    Zoghbi, S.S.4    Seibyl, J.5    Innis, R.B.6
  • 12
    • 0031708893 scopus 로고    scopus 로고
    • The relative contributions of scatter and attenuation corrections toward improved brain SPECT quantification
    • R. Z. Stodilka, B. J. Kemp, P. Msaki, F. S. Prato, and R. L. Nicholson, "The relative contributions of scatter and attenuation corrections toward improved brain SPECT quantification," Phys. Med. Biol., vol. 43, pp. 2991-3008, 1998.
    • (1998) Phys. Med. Biol. , vol.43 , pp. 2991-3008
    • Stodilka, R.Z.1    Kemp, B.J.2    Msaki, P.3    Prato, F.S.4    Nicholson, R.L.5
  • 13
    • 0036464471 scopus 로고    scopus 로고
    • Impact of attenuation and scatter correction in SPECT for quantification of cerebral blood flow using [99mTc]-Ethyl cysteinate dimer
    • M. Shidahara, H. Watabe, and K. M. Kim et al., "Impact of attenuation and scatter correction in SPECT for quantification of cerebral blood flow using [99mTc]-Ethyl cysteinate dimer," IEEE Trans. Nucl. Sci., vol. 49, pp. 5-11, 2002.
    • (2002) IEEE Trans. Nucl. Sci. , vol.49 , pp. 5-11
    • Shidahara, M.1    Watabe, H.2    Kim, K.M.3
  • 14
    • 0042388275 scopus 로고    scopus 로고
    • Quantitative accuracy of dopaminergic neurotransmission imaging with (123)1 SPECT
    • M. Soret, P. M. Koulibaly, J. Darcourt, S. Hapdey, and I. Buvat, "Quantitative accuracy of dopaminergic neurotransmission imaging with (123)1 SPECT," J. Nucl. Med., vol. 44, pp. 1184-1193, 2003.
    • (2003) J. Nucl. Med. , vol.44 , pp. 1184-1193
    • Soret, M.1    Koulibaly, P.M.2    Darcourt, J.3    Hapdey, S.4    Buvat, I.5
  • 15
    • 0141446426 scopus 로고    scopus 로고
    • Correction for partialvolume effects on brain perfusion SPECT in healthy men
    • H. Matsuda, T. Ohnishi, and T. Asada et al., "Correction for partialvolume effects on brain perfusion SPECT in healthy men," J. Nucl. Med., vol. 44, pp. 1243-1252, 2003.
    • (2003) J. Nucl. Med. , vol.44 , pp. 1243-1252
    • Matsuda, H.1    Ohnishi, T.2    Asada, T.3
  • 16
    • 0031932289 scopus 로고    scopus 로고
    • Reducing the influence of the partial volume effect on SPECT activity quantitation with 3D modeling of spatial resolution in iterative reconstruction
    • P. H. Pretorius, M. A. King, T. S. Pan, D. J. de Vries, S. J. Click, and C. L. Byrne, "Reducing the influence of the partial volume effect on SPECT activity quantitation with 3D modeling of spatial resolution in iterative reconstruction," Phys. Med. Biol., vol. 43, pp. 407-420, 1998.
    • (1998) Phys. Med. Biol. , vol.43 , pp. 407-420
    • Pretorius, P.H.1    King, M.A.2    Pan, T.S.3    De Vries, D.J.4    Click, S.J.5    Byrne, C.L.6
  • 17
    • 0036216263 scopus 로고    scopus 로고
    • Performance evaluation of OSEM reconstruction algorithm incorporating three-dimensional distance-dependent resolution compensation for brain SPECT: A simulation study
    • T. Yokoi, H. Shinohara, and H. Onishi, "Performance evaluation of OSEM reconstruction algorithm incorporating three-dimensional distance-dependent resolution compensation for brain SPECT: a simulation study," Ann. Nucl. Med., vol. 16, pp. 11-18, 2002.
    • (2002) Ann. Nucl. Med. , vol.16 , pp. 11-18
    • Yokoi, T.1    Shinohara, H.2    Onishi, H.3
  • 18
    • 0031955835 scopus 로고    scopus 로고
    • Correction for partial volume effects in PET: Principle and validation
    • O. G. Rousset, Y. Ma, and A. C. Evans, "Correction for partial volume effects in PET: principle and validation," J. Nucl. Med., vol. 39, pp. 904-911, 1998.
    • (1998) J. Nucl. Med. , vol.39 , pp. 904-911
    • Rousset, O.G.1    Ma, Y.2    Evans, A.C.3
  • 20
    • 0031469798 scopus 로고    scopus 로고
    • Influence of OSEM, elliptical orbits and background activity on SPECT 3D resolution recovery
    • T. S. Pan, D. S. Luo, V. Kohli, and M. A. Kinig, "Influence of OSEM, elliptical orbits and background activity on SPECT 3D resolution recovery," Phys. Med. Biol., vol. 42, pp. 2517-2529, 1997.
    • (1997) Phys. Med. Biol. , vol.42 , pp. 2517-2529
    • Pan, T.S.1    Luo, D.S.2    Kohli, V.3    Kinig, M.A.4
  • 21
    • 0019136137 scopus 로고
    • The geometric transfer function component for scintillation camera collimators with straight parallel holes
    • C. E. Metz, F. B. Atkins, and R. N. Beck, "The geometric transfer function component for scintillation camera collimators with straight parallel holes," Phys. Med. Biol., vol. 25, pp. 1059-1070, 1989.
    • (1989) Phys. Med. Biol. , vol.25 , pp. 1059-1070
    • Metz, C.E.1    Atkins, F.B.2    Beck, R.N.3
  • 22
    • 0028700063 scopus 로고
    • Accelerated image reconstruction using ordered subsets of projection data
    • H. M. Hudson and R. S. Larkin, "Accelerated image reconstruction using ordered subsets of projection data," IEEE Trans. Med. Imag., vol. 13, pp. 601-609, 1994.
    • (1994) IEEE Trans. Med. Imag. , vol.13 , pp. 601-609
    • Hudson, H.M.1    Larkin, R.S.2
  • 23
    • 0028224395 scopus 로고
    • The importance and implementation of accurate 3D compensation methods for quantitative SPECT
    • B. M. W. Tsui, E. C. Frey, X. Zhao, D. S. Lalush, R. E. Johnston, and W. H. McCartney, "The importance and implementation of accurate 3D compensation methods for quantitative SPECT," Phys. Med. Biol., vol. 39, pp. 509-530, 1994.
    • (1994) Phys. Med. Biol. , vol.39 , pp. 509-530
    • Tsui, B.M.W.1    Frey, E.C.2    Zhao, X.3    Lalush, D.S.4    Johnston, R.E.5    McCartney, W.H.6
  • 24
    • 0030348470 scopus 로고    scopus 로고
    • A new method for modeling the spatially-variant, object-dependent scatter response function in SPECT
    • E. C. Frey and B. M. W. Tsui, "A new method for modeling the spatially-variant, object-dependent scatter response function in SPECT," in Proc. IEEE Nuclear Science Symp., vol. 2, 1996, pp. 1082-1086.
    • (1996) Proc. IEEE Nuclear Science Symp. , vol.2 , pp. 1082-1086
    • Frey, E.C.1    Tsui, B.M.W.2
  • 25
    • 0031980980 scopus 로고    scopus 로고
    • Fast implementations of reconstruction-based scatter compensation in fully 3D SPECT image reconstruction
    • D. J. Kadrmas, E. C. Frey, S. S. Karimi, and B. M. W. Tsui, "Fast implementations of reconstruction-based scatter compensation in fully 3D SPECT image reconstruction," Phys. Med. Biol., vol. 43, pp. 857-873, 1998.
    • (1998) Phys. Med. Biol. , vol.43 , pp. 857-873
    • Kadrmas, D.J.1    Frey, E.C.2    Karimi, S.S.3    Tsui, B.M.W.4
  • 29
    • 0003063484 scopus 로고
    • A public domain simulation system for emission tomography: Photon tracking through heterogeneous attenuation using importance sampling
    • R. L. Harrison, S. B. Gillespie, S. D. Vannoy, M. S. Kaplan, and T. K. Lewellen, "A public domain simulation system for emission tomography: photon tracking through heterogeneous attenuation using importance sampling," J. Nucl. Med., vol. 34, p. 60P, 1993.
    • (1993) J. Nucl. Med. , vol.34
    • Harrison, R.L.1    Gillespie, S.B.2    Vannoy, S.D.3    Kaplan, M.S.4    Lewellen, T.K.5
  • 30
    • 0032920532 scopus 로고    scopus 로고
    • Simplified reference region model for the kinetic analysis of [99mTc]TRODAT-l binding to dopamine transporters in nonhuman primates using single-photon emission tomography
    • P. D. Acton, S. A. Kushner, M. P. Rung, P. D. Mozley, K. Plossl, and H. F. Kung, "Simplified reference region model for the kinetic analysis of [99mTc]TRODAT-l binding to dopamine transporters in nonhuman primates using single-photon emission tomography," Eur. J. Nucl. Med., vol. 26, pp. 518-526, 1999.
    • (1999) Eur. J. Nucl. Med. , vol.26 , pp. 518-526
    • Acton, P.D.1    Kushner, S.A.2    Rung, M.P.3    Mozley, P.D.4    Plossl, K.5    Kung, H.F.6
  • 31
    • 0034850254 scopus 로고    scopus 로고
    • Evaluation of early-stage Parkinson's disease with 99mTc-TRODAT-l imaging
    • W. S. Huang, S. Z. Lin, J. C. Lin, S. P. Wey, G. Ting, and R. S. Liu, "Evaluation of early-stage Parkinson's disease with 99mTc-TRODAT-l imaging," J. Nucl. Med., vol. 42, pp. 1303-1308, 2001.
    • (2001) J. Nucl. Med. , vol.42 , pp. 1303-1308
    • Huang, W.S.1    Lin, S.Z.2    Lin, J.C.3    Wey, S.P.4    Ting, G.5    Liu, R.S.6
  • 32
    • 0023422273 scopus 로고
    • Noise and edge artifacts in maximum-likelihood reconstructions for emission tomography
    • D. L. Snyder, M. I. Miller, L. J. Thomas JR, and D. G. Politte, "Noise and edge artifacts in maximum-likelihood reconstructions for emission tomography," IEEE. Trans. Med. Imag., vol. MI-6, no. 3, pp. 228-238, 1987.
    • (1987) IEEE. Trans. Med. Imag. , vol.MI-6 , Issue.3 , pp. 228-238
    • Snyder, D.L.1    Miller, M.I.2    Thomas Jr., L.J.3    Politte, D.G.4
  • 33
    • 84939045202 scopus 로고
    • Object-dependent performance comparison of two iterative reconstruction algorithms
    • J. A. Stamos, W. L. Rogers, N. H. Clinthorne, and K. F. Koral, "Object-dependent performance comparison of two iterative reconstruction algorithms," IEEE. Trans. Nucl. Sci., vol. 35, no. 1, pp. 611-614, 1988.
    • (1988) IEEE. Trans. Nucl. Sci. , vol.35 , Issue.1 , pp. 611-614
    • Stamos, J.A.1    Rogers, W.L.2    Clinthorne, N.H.3    Koral, K.F.4
  • 34
    • 0027398350 scopus 로고
    • The convergence of object dependent resolution in maximum likelihood based tomographic image reconstruction
    • J.-S. Liow and S. C. Strother, "The convergence of object dependent resolution in maximum likelihood based tomographic image reconstruction," Phys. Med. Biol., vol. 38, pp. 55-70, 1988.
    • (1988) Phys. Med. Biol. , vol.38 , pp. 55-70
    • Liow, J.-S.1    Strother, S.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.