메뉴 건너뛰기




Volumn 109, Issue 12, 2012, Pages 1787-1791

Echocardiographic evaluation of iatrogenic atrial septal defect after catheter-based mitral valve clip insertion

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; CALCULATION; CARDIOVASCULAR EQUIPMENT; CATHETER BASED MITRAL VALVE CLIP INSERTION; CLINICAL ARTICLE; FEMALE; HEART ATRIUM SEPTUM DEFECT; HEART CYCLE; HUMAN; IATROGENIC HEART ATRIUM SEPTUM DEFECT; INTERMETHOD COMPARISON; MALE; MITRAL VALVE CLIP; MITRAL VALVE REGURGITATION; MITRAL VALVE REPAIR; OUTCOME ASSESSMENT; PRIORITY JOURNAL; THREE DIMENSIONAL ECHOCARDIOGRAPHY; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; TWO DIMENSIONAL ECHOCARDIOGRAPHY;

EID: 84861633334     PISSN: 00029149     EISSN: 18791913     Source Type: Journal    
DOI: 10.1016/j.amjcard.2012.02.023     Document Type: Article
Times cited : (41)

References (16)
  • 4
    • 7744232153 scopus 로고    scopus 로고
    • Persistence of septal defects after transseptal puncture for pulmonary vein isolation procedures
    • O. Obel, M. Mansour, M. Picard, J. Ruskin, D. Keane Persistence of septal defects after transseptal puncture for pulmonary vein isolation procedures Pacing Clin Electrophysiol 27 2004 1411 1414
    • (2004) Pacing Clin Electrophysiol , vol.27 , pp. 1411-1414
    • Obel, O.1    Mansour, M.2    Picard, M.3    Ruskin, J.4    Keane, D.5
  • 7
    • 79958827076 scopus 로고    scopus 로고
    • The incidence and long-term clinical outcome of iatrogenic atrial septal defects secondary to transseptal catheterization with a 12F transseptal sheath
    • M. Singh, S. Douglas, Y. Reddy The incidence and long-term clinical outcome of iatrogenic atrial septal defects secondary to transseptal catheterization with a 12F transseptal sheath Circ Arrhythm Electrophysiol 4 2011 166 171
    • (2011) Circ Arrhythm Electrophysiol , vol.4 , pp. 166-171
    • Singh, M.1    Douglas, S.2    Reddy, Y.3
  • 8
    • 77749323251 scopus 로고    scopus 로고
    • Persistent iatrogenic atrial septal defect after a single-puncture, double-transseptal approach for pulmonary vein isolation using a remote robotic navigation system: Results from a prospective study
    • A. Rillig, U. Meyerfeldt, M. Kunze, R. Birkemeyer, T. Miljak, S. Jackle, B. Hajredini, F. Treusch, W. Jung Persistent iatrogenic atrial septal defect after a single-puncture, double-transseptal approach for pulmonary vein isolation using a remote robotic navigation system: results from a prospective study Europace 12 2010 331 336
    • (2010) Europace , vol.12 , pp. 331-336
    • Rillig, A.1    Meyerfeldt, U.2    Kunze, M.3    Birkemeyer, R.4    Miljak, T.5    Jackle, S.6    Hajredini, B.7    Treusch, F.8    Jung, W.9
  • 9
    • 48949098859 scopus 로고    scopus 로고
    • 2008 Focused update incorporated into the ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: A report of the American College of Cardiology
    • American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the 1998 Guidelines for the Management of Patients with Valvular Heart Disease) Endorsed by the Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, and Society of Thoracic Surgeons
    • O. Bonow, A. Carabello, K. Chatterjee, C. de Leon, P. Faxon, D. Freed, H. Gaasch, W. Lytle, A. Nishimura, T. O'Gara, A. O'Rourke, M. Otto, M. Shah, S. Shanewise 2008 focused update incorporated into the ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the 1998 Guidelines for the Management of Patients With Valvular Heart Disease) Endorsed by the Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, and Society of Thoracic Surgeons J Am Coll Cardiol 52 2008 e1 e142
    • (2008) J Am Coll Cardiol , vol.52
    • Bonow, O.1    Carabello, A.2    Chatterjee, K.3    De Leon, C.4    Faxon, P.5    Freed, D.6    Gaasch, H.7    Lytle, W.8    Nishimura, A.9    O'Gara, T.10    O'Rourke, A.11    Otto, M.12    Shah, M.13    Shanewise, S.14
  • 12
    • 0017871784 scopus 로고
    • Two-dimensional real-time ultrasonic imaging of the heart and great vessels Technique, image orientation, structure identification, and validation
    • J. Tajik, B. Seward, J. Hagler, D. Mair, T. Lie Two-dimensional real-time ultrasonic imaging of the heart and great vessels Technique, image orientation, structure identification, and validation Mayo Clin Proc 53 1978 271 303
    • (1978) Mayo Clin Proc , vol.53 , pp. 271-303
    • Tajik, J.1    Seward, B.2    Hagler, J.3    Mair, D.4    Lie, T.5
  • 13
    • 0034129649 scopus 로고    scopus 로고
    • Dynamic morphology of the secundum atrial septal defect evaluated by three dimensional transoesophageal echocardiography
    • V. Maeno, N. Benson, R. McLaughlin, C. Boutin Dynamic morphology of the secundum atrial septal defect evaluated by three dimensional transoesophageal echocardiography Heart 83 2000 673 677
    • (2000) Heart , vol.83 , pp. 673-677
    • Maeno, V.1    Benson, N.2    McLaughlin, R.3    Boutin, C.4
  • 14
    • 0034987187 scopus 로고    scopus 로고
    • Dynamic changes of atrial septal defect area: New insights by three-dimensional volume-rendered echocardiography with high temporal resolution
    • M. Handke, M. Schafer, G. Muller, A. Schochlin, E. Magosaki, A. Geibel Dynamic changes of atrial septal defect area: new insights by three-dimensional volume-rendered echocardiography with high temporal resolution Eur J Echocardiogr 2 2001 46 51
    • (2001) Eur J Echocardiogr , vol.2 , pp. 46-51
    • Handke, M.1    Schafer, M.2    Muller, G.3    Schochlin, A.4    Magosaki, E.5    Geibel, A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.