메뉴 건너뛰기




Volumn 3, Issue 5, 2010, Pages 506-510

The association of patent foramen ovale morphology and stroke size in patients with paradoxical embolism

Author keywords

Echocardiography; Embolism; Foramen ovale patent; Stroke

Indexed keywords

ADULT; AGED; ARTICLE; BRAIN INFARCTION SIZE; CARDIOVASCULAR PARAMETERS; CONTROLLED STUDY; CRYPTOGENIC STROKE; DIFFUSION WEIGHTED IMAGING; DISEASE ASSOCIATION; DOPPLER ECHOGRAPHY; FEMALE; HEART ANEURYSM; HEART ATRIUM SEPTUM; HEART ATRIUM SEPTUM ANEURYSM; HEART STROKE VOLUME; HUMAN; INTRACARDIAC ECHOCARDIOGRAPHY; MAJOR CLINICAL STUDY; MALE; MAXIMUM PATENT FORAMEN OVALE HEIGHT; MINIMUM PATENT FORAMEN OVALE HEIGHT; NUCLEAR MAGNETIC RESONANCE IMAGING; PARADOXICAL EMBOLISM; PATENT FORAMEN OVALE; PATENT FORAMEN OVALE BUBBLE; PATENT FORAMEN OVALE HEIGHT; PRIORITY JOURNAL; RETROSPECTIVE STUDY; SEPTUM SECUNDUM THICKNESS; STROKE; TISSUE STRUCTURE; TOTAL SEPTUM EXCURSION DISTANCE; TRANSESOPHAGEAL ECHOCARDIOGRAPHY;

EID: 78650099760     PISSN: 19417640     EISSN: 19417632     Source Type: Journal    
DOI: 10.1161/CIRCINTERVENTIONS.109.908533     Document Type: Article
Times cited : (45)

References (24)
  • 1
    • 0031861858 scopus 로고    scopus 로고
    • The need to quantify right-to-left shunt in acute ischemic stroke a case-control study
    • Serena J, Segura T, Perez-Ayuso MJ, Bassaganyas J, Molins A, Dávalos A. The need to quantify right-to-left shunt in acute ischemic stroke: A case-control study. Stroke. 1998;29:1322-1328. (Pubitemid 28300064)
    • (1998) Stroke , vol.29 , Issue.7 , pp. 1322-1328
    • Serena, J.1    Segura, T.2    Perez-Ayuso, M.J.3    Bassaganyas, J.4    Molins, A.5    Davalos, A.6
  • 4
    • 0021352808 scopus 로고
    • Incidence and size of patent foramen ovale during the first 10 decades of life: An autopsy study of 965 normal hearts
    • Hagen PT, Scholz DG, Edwards WD. Incidence and size of patent foramen ovale during the first 10 decades of life: An autopsy study of 965 normal hearts. Mayo Clin Proc. 1984;59:17-20. (Pubitemid 14175830)
    • (1984) Mayo Clinic Proceedings , vol.59 , Issue.1 , pp. 17-20
    • Hagen, P.T.1    Scholz, D.G.2    Edwards, W.D.3
  • 5
    • 0034840351 scopus 로고    scopus 로고
    • Patent foramen ovale: A review of associated conditions and the impact of physiological size
    • DOI 10.1016/S0735-1097(01)01427-9, PII S0735109701014279
    • Kerut EK, Norfleet WT, Plotnick GD, Kerut EK, Norfleet WT, Plotnick GD, Giles TD. Patent foramen ovale: A review of associated conditions and the impact of physiological size. J Am Coll Cardiol. 2001;38: 613-623. (Pubitemid 32835725)
    • (2001) Journal of the American College of Cardiology , vol.38 , Issue.3 , pp. 613-623
    • Kerut, E.K.1    Norfleet, W.T.2    Plotnick, G.D.3    Giles, T.D.4
  • 7
    • 0034711135 scopus 로고    scopus 로고
    • Interatrial septal abnormalities and stroke: A meta-analysis of case-control studies
    • Overell JR, Bone I, Lees KR. Interatrial septal abnormalities and stroke: A meta-analysis of case-control studies. Neurology. 2000;55:1172-1179.
    • (2000) Neurology. , vol.55 , pp. 1172-1179
    • Overell, J.R.1    Bone, I.2    Lees, K.R.3
  • 8
    • 0037024261 scopus 로고    scopus 로고
    • Effect of medical treatment in stroke patients with patent foramen ovale: Patent foramen ovale in Cryptogenic Stroke Study
    • DOI 10.1161/01.CIR.0000017498.88393.44
    • Homma S, Sacco RL, Di Tullio MR, Sciacca RR, Mohr JP. Effect of medical treatment in stroke patients with patent foramen ovale: Patent foramen ovale in Cryptogenic Stroke Study. Circulation. 2002;105: 2625-2631. (Pubitemid 34596039)
    • (2002) Circulation , vol.105 , Issue.22 , pp. 2625-2631
    • Homma, S.1    Sacco, R.L.2    Di Tullio, M.R.3    Sciacca, R.R.4    Mohr, J.P.5
  • 9
    • 0030705228 scopus 로고    scopus 로고
    • Frequency of deep vein thrombosis in patients with patent foramen ovale and ischemic stroke or transient ischemic attack
    • DOI 10.1016/S0002-9149(97)00604-8, PII S0002914997006048
    • Lethen H, Flachskampf FA, Schneider R, Sliwka U, Köhn G, Noth J, Hanrath P. Frequency of deep vein thrombosis in patients with patent foramen ovale and ischemic stroke or transient ischemic attack. Am J Cardiol. 1997;80:1066-1069. (Pubitemid 27459209)
    • (1997) American Journal of Cardiology , vol.80 , Issue.8 , pp. 1066-1069
    • Lethen, H.1    Flachskampf, F.A.2    Schneider, R.3    Sliwka, U.4    Kohn, G.5    Noth, J.6    Hanrath, P.7
  • 10
    • 0028832597 scopus 로고
    • Recurrent cerebrovascular events in patients with patent foramen ovale, atrial septal aneurysm, or both and cryptogenic stroke or transient ischemic attack
    • French Study Group on Patent Foramen Ovale and Atrial Septal Aneurysm
    • Mas JL, Zuber M. Recurrent cerebrovascular events in patients with patent foramen ovale, atrial septal aneurysm, or both and cryptogenic stroke or transient ischemic attack. French Study Group on Patent Foramen Ovale and Atrial Septal Aneurysm. Am Heart J. 1995;130: 1083-1088.
    • (1995) Am Heart J. , vol.130 , pp. 1083-1088
    • Mas, J.L.1    Zuber, M.2
  • 11
    • 0035857141 scopus 로고    scopus 로고
    • Recurrent cerebrovascular events in young adults with patent foramen ovale, atrial septal aneurysm, or both
    • Mas JL, Arquizan C, Lamy C, Zuber M, Cabanes L, Derumeaux G, Coste J. Recurrent cerebrovascular events in young adults with patent foramen ovale, atrial septal aneurysm, or both. N Engl J Med. 2001;345: 1740-1746.
    • (2001) N Engl J Med. , vol.345 , pp. 1740-1746
    • Mas, J.L.1    Arquizan, C.2    Lamy, C.3    Zuber, M.4    Cabanes, L.5    Derumeaux, G.6    Coste, J.7
  • 16
    • 33747170176 scopus 로고    scopus 로고
    • Diffusion-weighted imaging in stroke attributable to patent foramen ovale: Significance of concomitant atrial septum aneurysm
    • DOI 10.1161/01.STR.0000231655.52686.ab, PII 0000767020060800000021
    • Bonati LH, Kessel-Schaefer A, Linka AZ, Buser P, Wetzel SG, Radue EW, Lyrer PA, Engelter ST. Diffusion-weighted imaging in stroke attributable to patent foramen ovale: Significance of concomitant atrial septum aneurysm. Stroke. 2006;37:2030-2034. (Pubitemid 44309899)
    • (2006) Stroke , vol.37 , Issue.8 , pp. 2030-2034
    • Bonati, L.H.1    Kessel-Schaefer, A.2    Linka, A.Z.3    Buser, P.4    Wetzel, S.G.5    Radue, E.-W.6    Lyrer, P.A.7    Engelter, S.T.8
  • 17
  • 18
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • DOI 10.1191/096228099673819272
    • Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res. 1999;8:135-160. (Pubitemid 29425900)
    • (1999) Statistical Methods in Medical Research , vol.8 , Issue.2 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 19
    • 0028082344 scopus 로고
    • Characteristics of patent foramen ovale associated with cryptogenic stroke: A biplane transesophageal echocardiographic study
    • Homma S, Di Tullio MR, Sacco RL, Mihalatos D, Li Mandri G, Mohr JP. Characteristics of patent foramen ovale associated with cryptogenic stroke: A biplane transesophageal study. Stroke. 1994;25:582-586. (Pubitemid 24067070)
    • (1994) Stroke , vol.25 , Issue.3 , pp. 582-586
    • Homma, S.1    Di Tullio, M.R.2    Sacco, R.L.3    Mihalatos, D.4    Mandri, G.L.5    Mohr, J.P.6
  • 21
    • 1842528129 scopus 로고    scopus 로고
    • Practice parameter: Recurrent stroke with patent foramen ovale and atrial septal aneurysm
    • Report of the Quality Standards Subcommittee of the American Academy of Neurology
    • Messé SR, Silverman IE, Kizer JR, Homma S, Zahn C, Gronseth G, Kasner SE. Practice parameter: Recurrent stroke with patent foramen ovale and atrial septal aneurysm: Report of the Quality Standards Subcommittee of the American Academy of Neurology. Neurology. 2004; 62:1042-1050.
    • (2004) Neurology. , vol.62 , pp. 1042-1050
    • Messé, S.R.1    Silverman, I.E.2    Kizer, J.R.3    Homma, S.4    Zahn, C.5    Gronseth, G.6    Kasner, S.E.7
  • 22
    • 0028851906 scopus 로고
    • Identification of patent foramen ovale permitting paradoxic embolism
    • Hausmann D, Mugge A, Daniel WG. Identification of patent foramen ovale permitting paradoxic embolism. J Am Coll Cardiol. 1995;26: 1030-1038.
    • (1995) J Am Coll Cardiol. , vol.26 , pp. 1030-1038
    • Hausmann, D.1    Mugge, A.2    Daniel, W.G.3
  • 23
    • 0037271795 scopus 로고    scopus 로고
    • Patent foramen ovale: Anatomy versus pathophysiology - Which determines stroke risk?
    • DOI 10.1067/mje.2003.34
    • Natanzon A, Goldman ME. Patent foramen ovale: Anatomy versus pathophysiology- which determines stroke risk? J Am Soc Echocardiogr. 2003;16:71-76. (Pubitemid 36522819)
    • (2003) Journal of the American Society of Echocardiography , vol.16 , Issue.1 , pp. 71-76
    • Natanzon, A.1    Goldman, M.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.