메뉴 건너뛰기




Volumn 39, Issue 5, 2012, Pages 2386-2395

Scatter correction in cone-beam CT via a half beam blocker technique allowing simultaneous acquisition of scatter and image information

Author keywords

cone beam CT; FDK; half beam blocker; scatter correction; total variation

Indexed keywords

GRADIENT METHODS; IMAGE ACQUISITION; IMAGE RECONSTRUCTION; INTERPOLATION; MEAN SQUARE ERROR; STEEPEST DESCENT METHOD; X RAY DETECTORS;

EID: 84861629764     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3691901     Document Type: Article
Times cited : (51)

References (22)
  • 2
    • 11244314035 scopus 로고    scopus 로고
    • The influence of antiscatter grids on soft-tissue detectability in cone-beam computed tomography with flat-panel detectors
    • DOI 10.1118/1.1819789
    • J. H. Siewerdsen, D. J. Moseley, B. Bakhtiar, S. Richard, and D. A. Jaffray, The influence of antiscatter grids on soft-tissue detectability in cone-beam computed tomography with flat-panel detectors., Med. Phys. 31, 3506-3520 (2004). 10.1118/1.1819789 (Pubitemid 40065003)
    • (2004) Medical Physics , vol.31 , Issue.12 , pp. 3506-3520
    • Siewerdsen, J.H.1    Moseley, D.J.2    Bakhtiar, B.3    Richard, S.4    Jaffray, D.A.5
  • 3
    • 31044451240 scopus 로고    scopus 로고
    • A simple, direct method for x-ray scatter estimation and correction in digital radiography and cone-beam CT
    • DOI 10.1118/1.2148916
    • J. H. Siewerdsen, M. J. Daly, B. Bakhtiar, D. J. Moseley, S. Richard, H. Keller and D. A. Jaffray, A simple, direct method for x-ray scatter estimation and correction in digital radiography and cone-beam CT., Med. Phys. 33, 187-197 (2006). 10.1118/1.2148916 (Pubitemid 43121048)
    • (2006) Medical Physics , vol.33 , Issue.1 , pp. 187-197
    • Siewerdsen, J.H.1    Daly, M.J.2    Bakhtiar, B.3    Moseley, D.J.4    Richard, S.5    Keller, H.6    Jaffray, D.A.7
  • 4
    • 79551712656 scopus 로고    scopus 로고
    • Prior image constrained scatter correction in cone-beam computed tomography image-guided radiation therapy
    • 10.1088/0031-9155/56/4/009
    • S. Brunner, B. E. Nett, R. Tolakanahalli, and G. H. Chen, Prior image constrained scatter correction in cone-beam computed tomography image-guided radiation therapy., Phys. Med. Biol. 56, 1015-1030 (2011). 10.1088/0031-9155/56/ 4/009
    • (2011) Phys. Med. Biol. , vol.56 , pp. 1015-1030
    • Brunner, S.1    Nett, B.E.2    Tolakanahalli, R.3    Chen, G.H.4
  • 5
    • 58149242614 scopus 로고    scopus 로고
    • Scatter kernel estimation with an edge-spread function method for cone-beam computed tomography imaging
    • 10.1088/0031-9155/53/23/006
    • H. Li, R. Mohan and X. R. Zhu, Scatter kernel estimation with an edge-spread function method for cone-beam computed tomography imaging., Phys. Med. Biol. 53, 6729-6748 (2008). 10.1088/0031-9155/53/23/006
    • (2008) Phys. Med. Biol. , vol.53 , pp. 6729-6748
    • Li, H.1    Mohan, R.2    Zhu, X.R.3
  • 6
    • 34547098832 scopus 로고    scopus 로고
    • A new method for x-ray scatter correction: First assessment on a cone-beam CT experimental setup
    • DOI 10.1088/0031-9155/52/15/018, PII S0031915507451545, 018
    • J. Rinkel, L. Gerfault, F. Esteve, and J. M. Dinten, A new method for x-ray scatter correction: First assessment on a cone-beam CT experimental setup., Phys. Med. Biol. 52, 4633-4652 (2007). 10.1088/0031-9155/52/15/018 (Pubitemid 47103147)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.15 , pp. 4633-4652
    • Rinkel, J.1    Gerfault, L.2    Esteve, F.3    Dinten, J.-M.4
  • 7
    • 2442689175 scopus 로고    scopus 로고
    • X-ray scatter correction algorithm for cone beam CT imaging
    • DOI 10.1118/1.1711475
    • R. Ning, X. Tang, and D. Conover, X-ray scatter correction algorithm for cone beam CT imaging., Med. Phys. 31, 1195-1202 (2004). 10.1118/1.1711475 (Pubitemid 38656792)
    • (2004) Medical Physics , vol.31 , Issue.5 , pp. 1195-1202
    • Ning, R.1    Tang, X.2    Conover, D.3
  • 8
    • 61349173033 scopus 로고    scopus 로고
    • Noise suppression in scatter correction for cone-beam CT
    • 10.1118/1.3063001
    • L. Zhu, J. Wang, and L. Xing, Noise suppression in scatter correction for cone-beam CT., Med. Phys. 36, 741-752 (2009). 10.1118/1.3063001
    • (2009) Med. Phys. , vol.36 , pp. 741-752
    • Zhu, L.1    Wang, J.2    Xing, L.3
  • 9
    • 23844519433 scopus 로고    scopus 로고
    • X-ray scatter correction for cone-beam CT using moving blocker array
    • DOI 10.1117/12.594699, 31, Medical Imaging 2005 - Physics of Medical Imaging
    • L. Zhu, N. Strobel, and R. Fahrig, X-ray scatter correction for cone-beam CT using moving blocker array., in SPIE Medical Imaging: Physics of Medical Imaging (San Diego, CA, 2005), Vol. 5745, pp. 251-258. (Pubitemid 41146373)
    • (2005) Progress in Biomedical Optics and Imaging - Proceedings of SPIE , vol.5745 , pp. 251-258
    • Zhu, L.1    Strobel, N.2    Fahrig, R.3
  • 10
    • 66449132276 scopus 로고    scopus 로고
    • Scatter correction for cone-beam CT in radiation therapy
    • 10.1118/1.3130047
    • L. Zhu, Y. Xie, J. Wang, and L. Xing, Scatter correction for cone-beam CT in radiation therapy., Med. Phys. 36, 2258-2268 (2009). 10.1118/1.3130047
    • (2009) Med. Phys. , vol.36 , pp. 2258-2268
    • Zhu, L.1    Xie, Y.2    Wang, J.3    Xing, L.4
  • 11
    • 78149462521 scopus 로고    scopus 로고
    • Combining scatter reduction and correction to improve image quality in cone-beam computed tomography (CBCT)
    • 10.1118/1.3497272
    • J. Y. Jin, L. Ren, Q. Liu, J. Kim, N. Wen, H. Guan, B. Movsas, and I. J. Chetty, Combining scatter reduction and correction to improve image quality in cone-beam computed tomography (CBCT)., Med. Phys. 37, 5634-5644 (2010). 10.1118/1.3497272
    • (2010) Med. Phys. , vol.37 , pp. 5634-5644
    • Jin, J.Y.1    Ren, L.2    Liu, Q.3    Kim, J.4    Wen, N.5    Guan, H.6    Movsas, B.7    Chetty, I.J.8
  • 12
    • 78149426489 scopus 로고    scopus 로고
    • Scatter correction for cone-beam computed tomography using moving blocker strips: A preliminary study
    • 10.1118/1.3495819
    • J. Wang, W. Mao, and T. Solberg, Scatter correction for cone-beam computed tomography using moving blocker strips: A preliminary study., Med. Phys. 37, 5792-5800 (2010). 10.1118/1.3495819
    • (2010) Med. Phys. , vol.37 , pp. 5792-5800
    • Wang, J.1    Mao, W.2    Solberg, T.3
  • 13
    • 77954151598 scopus 로고    scopus 로고
    • Fast and accurate marker-based projective registration method for uncalibrated transmission electron microscope tilt series
    • 10.1088/0031-9155/55/12/010
    • H. Lee, J. Lee, Y. G. Shin, R. Lee, and L. Xing, Fast and accurate marker-based projective registration method for uncalibrated transmission electron microscope tilt series., Phys. Med. Biol. 55, 3417-3440 (2010). 10.1088/0031-9155/55/12/010
    • (2010) Phys. Med. Biol. , vol.55 , pp. 3417-3440
    • Lee, H.1    Lee, J.2    Shin, Y.G.3    Lee, R.4    Xing, L.5
  • 14
    • 51849124226 scopus 로고    scopus 로고
    • Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization
    • 10.1088/0031-9155/53/17/021
    • E. Y. Sidky and X. Pan, Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization., Phys. Med. Biol. 53, 4777-4807 (2008). 10.1088/0031-9155/53/17/021
    • (2008) Phys. Med. Biol. , vol.53 , pp. 4777-4807
    • Sidky, E.Y.1    Pan, X.2
  • 15
    • 70350718948 scopus 로고    scopus 로고
    • Enhanced imaging of microcalcifications in digital breast tomosynthesis through improved image-reconstruction algorithms
    • 10.1118/1.3232211
    • E. Y. Sidky, X. Pan, I. S. Reiser, R. M. Nishikawa, R. H. Moore, and D. B. Kopans, Enhanced imaging of microcalcifications in digital breast tomosynthesis through improved image-reconstruction algorithms., Med. Phys. 36, 4920-4932 (2009). 10.1118/1.3232211
    • (2009) Med. Phys. , vol.36 , pp. 4920-4932
    • Sidky, E.Y.1    Pan, X.2    Reiser, I.S.3    Nishikawa, R.M.4    Moore, R.H.5    Kopans, D.B.6
  • 16
    • 77956309884 scopus 로고    scopus 로고
    • Fast hybrid CPU- and GPU-based CT reconstruction algorithm using air skipping technique
    • 10.3233/XST-2010-0256
    • B. Lee, H. Lee, and Y. G. Shin, Fast hybrid CPU- and GPU-based CT reconstruction algorithm using air skipping technique., J. X-Ray Sci. Technol. 18, 221-234 (2010). 10.3233/XST-2010-0256
    • (2010) J. X-Ray Sci. Technol. , vol.18 , pp. 221-234
    • Lee, B.1    Lee, H.2    Shin, Y.G.3
  • 17
    • 0021445363 scopus 로고
    • Practical cone-beam algorithm
    • 10.1364/JOSAA.1.000612
    • L. A. Feldkamp, L. C. Davis, and J. W. Kress, Practical cone-beam algorithm., J. Opt. Soc. Am. A 1, 612-619 (1984). 10.1364/JOSAA.1.000612
    • (1984) J. Opt. Soc. Am. A , vol.1 , pp. 612-619
    • Feldkamp, L.A.1    Davis, L.C.2    Kress, J.W.3
  • 18
    • 0023792394 scopus 로고
    • An analytical model of the scattered radiation distribution in diagnostic radiology
    • 10.1118/1.596186
    • J. M. Boone and J. A. Seibert, An analytical model of the scattered radiation distribution in diagnostic radiology., Med. Phys. 15, 721-725 (1988). 10.1118/1.596186
    • (1988) Med. Phys. , vol.15 , pp. 721-725
    • Boone, J.M.1    Seibert, J.A.2
  • 22
    • 78149337084 scopus 로고    scopus 로고
    • Low-dose x-ray phase-contrast and absorption CT using equally sloped tomography
    • 10.1088/0031-9155/55/18/008
    • B. P. Fahimian, Y. Mao, P. Cloetens, and J. Miao, Low-dose x-ray phase-contrast and absorption CT using equally sloped tomography., Phys. Med. Biol. 55, 5383-5400 (2010). 10.1088/0031-9155/55/18/008
    • (2010) Phys. Med. Biol. , vol.55 , pp. 5383-5400
    • Fahimian, B.P.1    Mao, Y.2    Cloetens, P.3    Miao, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.