Volumn 83, Issue 3, 2012, Pages

Impact of heterogeneity-based dose calculation using a deterministic grid-based boltzmann equation solver for intracavitary brachytherapy

Author keywords

192Ir; Brachytherapy; Grid based Boltzmann solver; Intracavitary; TG 43

Indexed keywords

BOLTZMANN; BRACHYTHERAPY; CERVICAL CANCERS; CLINICAL PARAMETERS; COMPUTED TOMOGRAPHY; CONTRAST MATERIAL; DOSE CALCULATION; DOSIMETRIC IMPACT; DOSIMETRIC PARAMETER; GRID-BASED; INTERNATIONAL COMMISSION; INTRACAVITARY; MANCHESTER; RADIATION UNIT; SIGNIFICANT IMPACTS; SOLID MODEL; TASK GROUPS; TG-43; TISSUE HETEROGENEITY; TREATMENT PLANS;

EID: 84861621701     PISSN: 03603016     EISSN: 1879355X     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2011.12.074     Document Type: Article
Times cited : (39)

References (20)
  • 1
    • 72049083210 scopus 로고    scopus 로고
    • Three-dimensional imaging in gynecologic brachytherapy: A survey of the American Brachytherapy Society
    • A.N. Viswanathan, and B.A. Erickson Three-dimensional imaging in gynecologic brachytherapy: A survey of the American Brachytherapy Society Int J Radiat Oncol Biol Phys 76 2010 104 109
    • (2010) Int J Radiat Oncol Biol Phys , vol.76 , pp. 104-109
    • Viswanathan, A.N.1    Erickson, B.A.2
  • 2
    • 1142304255 scopus 로고    scopus 로고
    • Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations
    • M.J. Rivard, B.M. Coursey, and L.A. DeWerd Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations Med Phys 31 2004 633 674
    • (2004) Med Phys , vol.31 , pp. 633-674
    • Rivard, M.J.1    Coursey, B.M.2    Dewerd, L.A.3
  • 3
    • 54049155205 scopus 로고    scopus 로고
    • Patient-specific Monte Carlo dose calculations for high-dose-rate endorectal brachytherapy with shielded intracavitary applicator
    • E. Poon, J.F. Williamson, and T. Vuong Patient-specific Monte Carlo dose calculations for high-dose-rate endorectal brachytherapy with shielded intracavitary applicator Int J Radiat Oncol Biol Phys 72 2008 1259 1266
    • (2008) Int J Radiat Oncol Biol Phys , vol.72 , pp. 1259-1266
    • Poon, E.1    Williamson, J.F.2    Vuong, T.3
  • 4
    • 77955922487 scopus 로고    scopus 로고
    • Dosimetric effects of air pockets around high-dose rate brachytherapy vaginal cylinders
    • S. Richardson, G. Palaniswaamy, and P.W. Grigsby Dosimetric effects of air pockets around high-dose rate brachytherapy vaginal cylinders Int J Radiat Oncol Biol Phys 78 2010 276 279
    • (2010) Int J Radiat Oncol Biol Phys , vol.78 , pp. 276-279
    • Richardson, S.1    Palaniswaamy, G.2    Grigsby, P.W.3
  • 5
    • 58149115070 scopus 로고    scopus 로고
    • The effect of rectal heterogeneity on wall dose in high dose rate brachytherapy
    • I.S. Kwan, D. Wilkinson, and D. Cutajar The effect of rectal heterogeneity on wall dose in high dose rate brachytherapy Med Phys 36 2009 224 232
    • (2009) Med Phys , vol.36 , pp. 224-232
    • Kwan, I.S.1    Wilkinson, D.2    Cutajar, D.3
  • 6
    • 77954253361 scopus 로고    scopus 로고
    • Dose perturbation due to the polysulfone cap surrounding a Fletcher-Williamson colpostat
    • M.J. Price, S.F. Kry, and P.J. Eifel Dose perturbation due to the polysulfone cap surrounding a Fletcher-Williamson colpostat J Appl Clin Med Phys 11 2010 3146
    • (2010) J Appl Clin Med Phys , vol.11 , pp. 3146
    • Price, M.J.1    Kry, S.F.2    Eifel, P.J.3
  • 7
    • 0026652744 scopus 로고
    • Tissue inhomogeneity correction for brachytherapy sources in a heterogeneous phantom with cylindrical symmetry
    • A.S. Meigooni, and R. Nath Tissue inhomogeneity correction for brachytherapy sources in a heterogeneous phantom with cylindrical symmetry Med Phys 19 1992 401 407
    • (1992) Med Phys , vol.19 , pp. 401-407
    • Meigooni, A.S.1    Nath, R.2
  • 10
    • 2942693234 scopus 로고    scopus 로고
    • Proposed guidelines for image-based intracavitary brachytherapy for cervical carcinoma: Report from Image-Guided Brachytherapy Working Group
    • S. Nag, H. Cardenes, and S. Chang Proposed guidelines for image-based intracavitary brachytherapy for cervical carcinoma: Report from Image-Guided Brachytherapy Working Group Int J Radiat Oncol Biol Phys 60 2004 1160 1172
    • (2004) Int J Radiat Oncol Biol Phys , vol.60 , pp. 1160-1172
    • Nag, S.1    Cardenes, H.2    Chang, S.3
  • 11
    • 75749151354 scopus 로고    scopus 로고
    • 192Ir brachytherapy treatment planning system. Part I: Single sources and bounded homogeneous geometries
    • 192Ir brachytherapy treatment planning system. Part I: Single sources and bounded homogeneous geometries Med Phys 37 2010 649 661
    • (2010) Med Phys , vol.37 , pp. 649-661
    • Zourari, K.1    Pantelis, E.2    Moutsatsos, A.3
  • 12
    • 77956324804 scopus 로고    scopus 로고
    • 192Ir brachytherapy source cable length modeled using a grid-based Boltzmann transport equation solver
    • 192Ir brachytherapy source cable length modeled using a grid-based Boltzmann transport equation solver Med Phys 37 2010 4733 4743
    • (2010) Med Phys , vol.37 , pp. 4733-4743
    • Mikell, J.K.1    Mourtada, F.2
  • 13
    • 79953653860 scopus 로고    scopus 로고
    • Dosimetric accuracy of a deterministic radiation transport based [192]Ir brachytherapy treatment planning system. Part II: Monte Carlo and experimental verification of a multiple source dwell position plan employing a shielded applicator
    • L. Petrokokkinos, K. Zourari, and E. Pantelis Dosimetric accuracy of a deterministic radiation transport based [192]Ir brachytherapy treatment planning system. Part II: Monte Carlo and experimental verification of a multiple source dwell position plan employing a shielded applicator Med Phys 38 2011 1981 1992
    • (2011) Med Phys , vol.38 , pp. 1981-1992
    • Petrokokkinos, L.1    Zourari, K.2    Pantelis, E.3
  • 15
    • 77953503748 scopus 로고    scopus 로고
    • Comparison of a 3-D multi-group SN particle transport code with Monte Carlo for intracavitary brachytherapy of the cervix uteri
    • K.A. Gifford, T.A. Wareing, and G. Failla Comparison of a 3-D multi-group SN particle transport code with Monte Carlo for intracavitary brachytherapy of the cervix uteri J Appl Clin Med Phys 11 2010 3103
    • (2010) J Appl Clin Med Phys , vol.11 , pp. 3103
    • Gifford, K.A.1    Wareing, T.A.2    Failla, G.3
  • 17
    • 77953505983 scopus 로고    scopus 로고
    • Enhancements to commissioning techniques and quality assurance of brachytherapy treatment planning systems that use model-based dose calculation algorithms
    • M.J. Rivard, L. Beaulieu, and F. Mourtada Enhancements to commissioning techniques and quality assurance of brachytherapy treatment planning systems that use model-based dose calculation algorithms Med Phys 37 2010 2645 2658
    • (2010) Med Phys , vol.37 , pp. 2645-2658
    • Rivard, M.J.1    Beaulieu, L.2    Mourtada, F.3
  • 18
    • 36649020653 scopus 로고    scopus 로고
    • Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning
    • I.J. Chetty, B. Curran, and J.E. Cygler Report of the AAPM Task Group No. 105: Issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning Med Phys 34 2007 4818 4853
    • (2007) Med Phys , vol.34 , pp. 4818-4853
    • Chetty, I.J.1    Curran, B.2    Cygler, J.E.3
  • 19
    • 77955715785 scopus 로고    scopus 로고
    • Recommendations from Gynaecological (GYN) GEC-ESTRO Working Group: Considerations and pitfalls in commissioning and applicator reconstruction in 3D image-based treatment planning of cervix cancer brachytherapy
    • T.P. Hellebust, C. Kirisits, and D. Berger Recommendations from Gynaecological (GYN) GEC-ESTRO Working Group: Considerations and pitfalls in commissioning and applicator reconstruction in 3D image-based treatment planning of cervix cancer brachytherapy Radiother Oncol 96 2010 153 160
    • (2010) Radiother Oncol , vol.96 , pp. 153-160
    • Hellebust, T.P.1    Kirisits, C.2    Berger, D.3
  • 20
    • 84861626929 scopus 로고    scopus 로고
    • Monte Carlo verification of a CT/MR ovoid model used by a grid-based Boltzmann solver in a commercial treatment planning system
    • J. Mikell, and F. Mourtada Monte Carlo verification of a CT/MR ovoid model used by a grid-based Boltzmann solver in a commercial treatment planning system Brachytherapy 10 2011 S36
    • (2011) Brachytherapy , vol.10 , pp. 36
    • Mikell, J.1    Mourtada, F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.