Termination of malignant ventricular arrhythmias with an implanted automatic defibrillator in human beings
-
Mirowski M, Reid PR, Mower MM, Watkins L, Gott VL, Schauble JF, et al. Termination of malignant ventricular arrhythmias with an implanted automatic defibrillator in human beings. N Engl J Med 1980;303:322-4.
-
(1980)
N Engl J Med
, vol.303
, pp. 322-324
-
-
Mirowski, M.1
Reid, P.R.2
Mower, M.M.3
Watkins, L.4
Gott, V.L.5
Schauble, J.F.6
-
3
-
-
0037149716
-
Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction
-
Moss AJ, Zareba W, Hall WJ, Klein H, Wilber DJ, Cannom DS, et al. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med 2002;346:877-83.
-
(2002)
N Engl J Med
, vol.346
, pp. 877-883
-
-
Moss, A.J.1
Zareba, W.2
Hall, W.J.3
Klein, H.4
Wilber, D.J.5
Cannom, D.S.6
-
5
-
-
76649138577
-
Update on cardiovascular implantable electronic device infections and their management
-
Baddour LM, Epstein AE, Erickson CC, Knight BP, Levison ME, Lockhart PB, et al. Update on cardiovascular implantable electronic device infections and their management. Circulation 2010;121:458-77.
-
(2010)
Circulation
, vol.121
, pp. 458-477
-
-
Baddour, L.M.1
Epstein, A.E.2
Erickson, C.C.3
Knight, B.P.4
Levison, M.E.5
Lockhart, P.B.6
-
6
-
-
33746208049
-
Rising rates of cardiac rhythm management device infections in the United States: 1996 through 2003
-
Voigt A, Shalaby A, Saba S. Rising rates of cardiac rhythm management device infections in the United States: 1996 through 2003. J Am Coll Cardiol 2006;48: 590-1.
-
(2006)
J Am Coll Cardiol
, vol.48
, pp. 590-591
-
-
Voigt, A.1
Shalaby, A.2
Saba, S.3
-
7
-
-
34548695954
-
Risk factors related to infections of implanted pacemakers and cardioverter-defibrillators: Result of large prospective study
-
Klug D, Balde M, Pavin D, Hidden-Lucet F, Clementy J, Sadoul N, et al. Risk factors related to infections of implanted pacemakers and cardioverter-defibrillators: result of large prospective study. Circulation 2007;116:1349-55.
-
(2007)
Circulation
, vol.116
, pp. 1349-55
-
-
Klug, D.1
Balde, M.2
Pavin, D.3
Hidden-Lucet, F.4
Clementy, J.5
Sadoul, N.6
-
8
-
-
34447109046
-
Risk factor analysis of permament pacemaker infection
-
Sohail MR, Ulan DZ, Khan AH, Friedman PA, Hayes DL, Wilson WR, et al. Risk factor analysis of permament pacemaker infection. Clin Infect Dis 2007;45:166-73.
-
(2007)
Clin Infect Dis
, vol.45
, pp. 166-173
-
-
Sohail, M.R.1
Ulan, D.Z.2
Khan, A.H.3
Friedman, P.A.4
Hayes, D.L.5
Wilson, W.R.6
-
9
-
-
77954065971
-
Device-related infection among patients with pacemakers and implantable defibrillators: Incidence, risk factors and consequences
-
Nery PB, Fernandes R, Nair GM, Sumner GL, Ribas CS, Menon SM, et al. Device-related infection among patients with pacemakers and implantable defibrillators: incidence, risk factors and consequences. J Cardiovasc Electrophysiol 2010;21:786-90.
-
(2010)
J Cardiovasc Electrophysiol
, vol.21
, pp. 786-790
-
-
Nery, P.B.1
Fernandes, R.2
Nair, G.M.3
Sumner, G.L.4
Ribas, C.S.5
Menon, S.M.6
-
10
-
-
0035503196
-
Device-associated infections: A macroproblem that starts with microadherence
-
Darouiche RO. Device-associated infections: a macroproblem that starts with microadherence. Clin Infect Dis 2001;33:1567-72.
-
(2001)
Clin Infect Dis
, vol.33
, pp. 1567-72
-
-
Darouiche, R.O.1
-
11
-
-
66749148454
-
A single-centre experience of over one thousand lead extraction
-
Kennergren C, Bjurman C, Wiklund R, Gabel J. A single-centre experience of over one thousand lead extraction. Europace 2009;11:612-7.
-
(2009)
Europace
, vol.11
, pp. 612-617
-
-
Kennergren, C.1
Bjurman, C.2
Wiklund, R.3
Gabel, J.4
-
12
-
-
0031888479
-
Insulation leads failure: Is it a matter of insulation coating, venous approach, or both?
-
Antonelli D, Rosenfeld T, Freedberg NA, Palma E, Gross JN, Furman S. Insulation leads failure: is it a matter of insulation coating, venous approach, or both? PACE 1998 21 418-21
-
(1998)
PACE
, vol.21
, pp. 418-421
-
-
Antonelli, D.1
Rosenfeld, T.2
Freedberg, N.A.3
Palma, E.4
Gross, J.N.5
Furman, S.6
-
13
-
-
0028894429
-
Long-term follow-up of pacemaker lead systems: Establishment of standards of quality
-
Furman S, Benedek MZ, Andrews CA, Gross JN, Ritacco R. Long-term follow-up of pacemaker lead systems: establishment of standards of quality. PACE 1995;18: 271-85.
-
(1995)
PACE
, vol.18
, pp. 271-285
-
-
Furman, S.1
Benedek, M.Z.2
Andrews, C.A.3
Gross, J.N.4
Ritacco, R.5
-
14
-
-
0027285289
-
Anatomical mechanisms explaining damage to pacemaker leads, defibrillator leads, and failure of central venous catheters adjacent to the sternoclavicular joint
-
Magney JE, Flynn DM, Parsons JA, Staplin DH, Chin-Purcell MV, Milstein S, et al. Anatomical mechanisms explaining damage to pacemaker leads, defibrillator leads, and failure of central venous catheters adjacent to the sternoclavicular joint. Pacing Clin Electrophysiol 1993;16:445-57.
-
(1993)
Pacing Clin Electrophysiol
, vol.16
, pp. 445-457
-
-
Magney, J.E.1
Flynn, D.M.2
Parsons, J.A.3
Staplin, D.H.4
Chin-Purcell, M.V.5
Milstein, S.6
-
15
-
-
0029789774
-
Lead fracture in cephalic versus subclavian approach with transvenous implantable cardioverter defibrillator systems
-
Gallik DM, Ben-Zur UM, Gross JN, Furman S. Lead fracture in cephalic versus subclavian approach with transvenous implantable cardioverter defibrillator systems. Pacing Clin Electrophysiol 1996;19:1089-94.
-
(1996)
Pacing Clin Electrophysiol
, vol.19
, pp. 1089-94
-
-
Gallik, D.M.1
Ben-Zur, U.M.2
Gross, J.N.3
Furman, S.4
-
16
-
-
84861618264
-
The reliability of modern pacing leads
-
Ebert MJ, Stokes KB, McVenes R. The reliability of modern pacing leads. Ther Res 1999;20:295-301.
-
(1999)
Ther Res
, vol.20
, pp. 295-301
-
-
Ebert, M.J.1
Stokes, K.B.2
McVenes, R.3
-
17
-
-
0042421643
-
Pacemaker lead failure suggestive of crush injury
-
Altun A, Erdog?an O. Pacemaker lead failure suggestive of crush injury. Cardiol Rev 2003;11:256.
-
(2003)
Cardiol Rev
, vol.11
, pp. 256
-
-
Altun, A.1
Erdogan, O.2
-
18
-
-
37349028272
-
Pacemaker lead failure due to crush injury
-
Erdog?an O, Aktoz M. Pacemaker lead failure due to crush injury. Anadolu Kardiyol Derg 2007;7:436-48.
-
(2007)
Anadolu Kardiyol Derg
, vol.7
, pp. 436-448
-
-
Erdogan, O.1
Aktoz, M.2
-
19
-
-
0027295161
-
Anatomical and morphological evaluation of pacemaker leads compression
-
Jacobs DM, Fink AS, Miller RP, Anderson WR, Mcvenes RD, Lessar JF, et al. Anatomical and morphological evaluation of pacemaker leads compression. PACE 1993;16:434-44.
-
(1993)
PACE
, vol.16
, pp. 434-444
-
-
Jacobs, D.M.1
Fink, A.S.2
Miller, R.P.3
Anderson, W.R.4
McVenes, R.D.5
Lessar, J.F.6
-
20
-
-
0030910516
-
Incidence and implications of abrasion of implantable cardioverter-defibrillator leads
-
De Lurgio DB, Sathavorn C, Mera F, Leon A,Walter PF, Langberg JJ. Incidence and implications of abrasion of implantable cardioverter-defibrillator leads. Am J Cardiol 1997;79:1409-11.
-
(1997)
Am J Cardiol
, vol.79
, pp. 1409-11
-
-
De Lurgio, D.B.1
Sathavorn, C.2
Mera, F.3
Leon Awalter, P.F.4
Langberg, J.J.5
-
21
-
-
84891739401
-
High incidence of atrial lead insulation failure in sub-pectoral defibrillator pockets
-
Gilligan DM, Joyner CA, Gilliam FR. High incidence of atrial lead insulation failure in sub-pectoral defibrillator pockets. Heart Rhythm 2005;2:s6.
-
(2005)
Heart Rhythm
, vol.2
-
-
Gilligan, D.M.1
Joyner, C.A.2
Gilliam, F.R.3
-
22
-
-
0030891130
-
Permanent pacing system malfunction due to hidden adjacent fractures of atrial and ventricular leads
-
Wang L, Davis MJE. Permanent pacing system malfunction due to hidden adjacent fractures of atrial and ventricular leads. Int J Cardiol 1997;59:86-7.
-
(1997)
J Cardiol
, vol.59
, pp. 86-87
-
-
Wang, L.1
Mje, D.2
-
23
-
-
13344262704
-
Evaluation and extraction of the Accufix atrial J lead
-
Daoud EG, Kou W, Davidson T, Niebauer M, Bogun F, Castellani M, et al. Evaluation and extraction of the Accufix atrial J lead. Am Heart J 1996;131:266-9.
-
(1996)
Am Heart J
, vol.131
, pp. 266-269
-
-
Daoud, E.G.1
Kou, W.2
Davidson, T.3
Niebauer, M.4
Bogun, F.5
Castellani, M.6
-
24
-
-
77951166174
-
Przetarcie silikonowych izolacji elektrod wewna?trzsercowych Nowo odkryte zjawisko w elektroterapii: Obserwacje w?asne
-
Kutarski A, Ma?ecka B. Przetarcie silikonowych izolacji elektrod wewna?trzsercowych. Nowo odkryte zjawisko w elektroterapii: obserwacje w?asne. Folia Cardiologica Excerpta 2009;4:126-31.
-
(2009)
Folia Cardiologica Excerpta
, vol.4
, pp. 126-131
-
-
Kutarski, A.1
Maecka, B.2
-
25
-
-
0001635323
-
Recommendations for extraction of chronically implanted transvenous pacing and defibrillator leads: Indications, facilities, training
-
Love CJ, Wilkoff BL, Byrd CL, Belott PH, Brinker JA, Fearnot NE, et al. Recommendations for extraction of chronically implanted transvenous pacing and defibrillator leads: indications, facilities, training. PACE 2000;23:544-51.
-
(2000)
PACE
, vol.23
, pp. 544-551
-
-
Love, C.J.1
Wilkoff, B.L.2
Byrd, C.L.3
Belott, P.H.4
Brinker, J.A.5
Fearnot, N.E.6
-
26
-
-
67549100824
-
Transvenous lead extraction: Heart Rhythm Society Expert Consensus on Facilities, Training, Indications, and Patient Management
-
Wilkoff BL, Love CJ, Byrd CL, Bongiorni MG, Carrillo RG, Crossley GH, et al. Transvenous lead extraction: Heart Rhythm Society Expert Consensus on Facilities, Training, Indications, and Patient Management. Heart Rhythm 2009;6: 1085-104.
-
(2009)
Heart Rhythm
, vol.6
, pp. 1085-104
-
-
Wilkoff, B.L.1
Love, C.J.2
Byrd, C.L.3
Bongiorni, M.G.4
Carrillo, R.G.5
Crossley, G.H.6
-
28
-
-
73849120250
-
Contemporary management of and outcomes from cardiac device related infections
-
Margey R, McCann H, Blake G, Keelan E, Galvin J, Lynch M, et al. Contemporary management of and outcomes from cardiac device related infections. Europace 2010;12:64-70.
-
(2010)
Europace
, vol.12
, pp. 64-70
-
-
Margey, R.1
McCann, H.2
Blake, G.3
Keelan, E.4
Galvin, J.5
Lynch, M.6
-
29
-
-
18244420080
-
Pacemaker infective endocarditis
-
Cacoub P, Leprince P, Hounsfater P, Doroub R, Wecksler B, Bors V, et al. Pacemaker infective endocarditis. Am J Cardiol 1998;82:480-4.
-
(1998)
Am J Cardiol
, vol.82
, pp. 480-484
-
-
Cacoub, P.1
Leprince, P.2
Hounsfater, P.3
Doroub, R.4
Wecksler, B.5
Bors, V.6
-
30
-
-
0032510664
-
Antibiotic prophylaxis for permanent pacemaker implantation: A meta-analysis
-
Da Costa A, Kirkovian G, Coucherat M, Delahaye F, Chevalier P, Cerisier A, et al. Antibiotic prophylaxis for permanent pacemaker implantation: a meta-analysis. Circulation 1998;97:1796-801.
-
(1998)
Circulation
, vol.97
, pp. 1796-801
-
-
Da Costa, A.1
Kirkovian, G.2
Coucherat, M.3
Delahaye, F.4
Chevalier, P.5
Cerisier, A.6
-
31
-
-
0035571673
-
Biofilms in peritoneal dialysis
-
Dasgupta MK, Larabie M. Biofilms in peritoneal dialysis. Perit Dial Int 2001; 21(Suppl. 3):213S-17S.
-
(2001)
Perit Dial Int
, vol.21
, Issue.3 SUPPL.
-
-
Dasgupta, M.K.1
Larabie, M.2
-
32
-
-
3042647452
-
Biofilms on silicone rubber insulators; Microbial composition and diagnostics of removal by use of ESEM/EDS composition of biofilms infecting silicone rubber insulators
-
Wallstrom S, Karlsson S. Biofilms on silicone rubber insulators; microbial composition and diagnostics of removal by use of ESEM/EDS composition of biofilms infecting silicone rubber insulators. Polym Degradation Stability 2004;85:841-6.
-
(2004)
Polym Degradation Stability
, vol.85
, pp. 841-846
-
-
Wallstrom, S.1
Karlsson, S.2
-
33
-
-
0028251307
-
In vitro ingrowth of yeasts into medical grade silicone rubber
-
Busscher HJ, de Boer CE, Verkerke GJ, Kalicharan R, Schutte HK, van der Mei HC. In vitro ingrowth of yeasts into medical grade silicone rubber. Int Biodeterioration Biodegradation 1994;33:383-90.
-
(1994)
Biodeterioration Biodegradation
, vol.33
, pp. 383-390
-
-
Busscher, H.J.1
De Boer, C.E.2
Verkerke, G.J.3
Kalicharan, R.4
Schutte, H.K.5
Van Der Mei, H.C.6
-
34
-
-
0027592927
-
Biodegradation of medical-grade silicone rubber used for voice prostheses: A SEM study
-
Neu TR, van der Mei HC, Busscher HJ, Dijk F, Verkerke GJ. Biodegradation of medical-grade silicone rubber used for voice prostheses: a SEM study. Biomaterials 1993;14:459-64.
-
(1993)
Biomaterials
, vol.14
, pp. 459-464
-
-
Neu, T.R.1
Van Der Mei, H.C.2
Busscher, H.J.3
Dijk, F.4
Verkerke, G.J.5
-
35
-
-
13544251204
-
Implantable cardioverter-defibrillator
-
Netherlands: Kluwer Academic Publishers
-
Liem BL. Implantable Cardioverter-Defibrillator. A Practical Manual. Netherlands: Kluwer Academic Publishers; 200p47.
-
A Practical Manual
, vol.200
, pp. 47
-
-
Liem, B.L.1
-
38
-
-
74549172877
-
Prevalence and risk factors related to infections of cardiac resynchronization therapy devices
-
Romeyer-Bouchard C, Da Costa A, Dauphinot V, Messier M, Bisch L, Samuel B, et al. Prevalence and risk factors related to infections of cardiac resynchronization therapy devices. Eur Heart J 2010;31:203-10.
-
(2010)
Eur Heart J
, vol.31
, pp. 203-210
-
-
Romeyer-Bouchard, C.1
Da Costa, A.2
Dauphinot, V.3
Messier, M.4
Bisch, L.5
Samuel, B.6
-
39
-
-
0028269080
-
Comparative thrombogenicity of pacemaker leads
-
Palatianos GM, Dewanjee MK, Panoutsopoulos G, Kapadvanjwala M, Novak S, Sfakianakis GN. Comparative thrombogenicity of pacemaker leads. PACE 1994; 17:141-5.
-
(1994)
PACE
, vol.17
, pp. 141-145
-
-
Palatianos, G.M.1
Dewanjee, M.K.2
Panoutsopoulos, G.3
Kapadvanjwala, M.4
Novak, S.5
Sfakianakis, G.N.6
-
40
-
-
21844440862
-
Histopathological study of tissue reaction to pacemaker electrodes implanted in the endocardium
-
Mase H, Tamura K, Hiromoto A, Hotta M, Hotomi S, Togashi M, et al. Histopathological study of tissue reaction to pacemaker electrodes implanted in the endocardium. J Nippon Med Sch 2005;72:52-9.
-
(2005)
J Nippon Med Sch
, vol.72
, pp. 52-59
-
-
Mase, H.1
Tamura, K.2
Hiromoto, A.3
Hotta, M.4
Hotomi, S.5
Togashi, M.6
-
41
-
-
55249098048
-
Higher incidence of pacemaker infection after replacement than after first implantation: Experiences from 36 076 consecutive patients
-
Johansen JB, Nielsen JC, Arnsbo P, Moller M, Pedersen AK, Mortensen PT. Higher incidence of pacemaker infection after replacement than after first implantation: experiences from 36 076 consecutive patients. Heart Rhythm 2006;3(Suppl 1): s102-s103.
-
(2006)
Heart Rhythm
, vol.3
, Issue.1 SUPPL.
-
-
Johansen, J.B.1
Nielsen, J.C.2
Arnsbo, P.3
Moller, M.4
Pedersen, A.K.5
Mortensen, P.T.6
-
42
-
-
80052845181
-
Insulation defects of thin high-voltage ICD leads: An underestimated problem?
-
Erkapic D, Duray GZ, Bauernfeind T, De Rosa S, Hohnloser SH Insulation defects of thin high-voltage ICD leads: an underestimated problem? J Cardiovasc Electrophysiol 2011 22 1018-22
-
(2011)
J Cardiovasc Electrophysiol
, vol.22
, pp. 1018-22
-
-
Erkapic, D.1
Duray, G.Z.2
Bauernfeind, T.3
De Rosa, S.4
Hohnloser, S.H.5
-
43
-
-
0024360004
-
The tricuspid valve: An unusual site of endocardial pacemaker lead fracture
-
Clarke B, Jones S, Gray HH, Rowland E. The tricuspid valve: an unusual site of endocardial pacemaker lead fracture. PACE 1989;12:1077-9.
-
(1989)
PACE
, vol.12
, pp. 1077-1079
-
-
Clarke, B.1
Jones, S.2
Gray, H.H.3
Rowland, E.4
|