메뉴 건너뛰기




Volumn 39, Issue 5, 2012, Pages 2456-2462

Improvements in dose accuracy delivered with static-MLC IMRT on an integrated linear accelerator control system

Author keywords

dose rate dependence; intensity modulated radiotherapy; over shoot; step and shoot; TrueBeam

Indexed keywords

BIOMEDICAL ENGINEERING; CONTROLLERS; IONIZATION OF LIQUIDS; PHOTONS; RADIOTHERAPY;

EID: 84861586443     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3701778     Document Type: Article
Times cited : (13)

References (12)
  • 1
    • 0031868367 scopus 로고    scopus 로고
    • Multileaf collimator leaf sequencing algorithm for intensity modulated beams with multiple static segments
    • DOI 10.1118/1.598315
    • P. Xia and L. J. Verhey, Multileaf collimator leaf sequencing algorithm for intensity modulated beams with multiple static segments., Med. Phys. 25 (8), 1424-1434 (1998). 10.1118/1.598315 (Pubitemid 28376353)
    • (1998) Medical Physics , vol.25 , Issue.8 , pp. 1424-1434
    • Xia, P.1    Verhey, L.J.2
  • 2
    • 0036127055 scopus 로고    scopus 로고
    • Communication and sampling rate limitations in IMRT delivery with a dynamic multileaf collimator system
    • DOI 10.1118/1.1449496
    • P. Xia, C. F. Chuang, and L. J. Verhey, Communication and sampling rate limitations in IMRT delivery with a dynamic multileaf collimator system., Med. Phys. 29 (3), 412-423 (2002). 10.1118/1.1449496 (Pubitemid 34241164)
    • (2002) Medical Physics , vol.29 , Issue.3 , pp. 412-423
    • Xia, P.1    Chuang, C.F.2    Verhey, L.J.3
  • 3
    • 31344462965 scopus 로고    scopus 로고
    • Dosimetry limitations and a dose correction methodology for step-and-shoot IMRT
    • DOI 10.1088/0031-9155/51/3/011, PII S0031915506072344
    • G. N. Grigorov, J. C. L. Chow, and R. B. Barnett, Dosimetry limitations and a dose correction methodology for step-and-shoot IMRT., Phys. Med. Biol. 51, 637-652 (2006). 10.1088/0031-9155/51/3/011 (Pubitemid 43139109)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.3 , pp. 637-652
    • Grigorov, G.N.1    Chow, J.C.L.2    Barnett, R.B.3
  • 4
    • 34748915716 scopus 로고    scopus 로고
    • Examination of geometric and dosimetric accuracies of gated step-and-shoot intensity modulated radiation therapy
    • DOI 10.1118/1.2776671
    • R. D. Wiersma and L. Xing, Examination of geometric and dosimetric accuracies of gated step-and-shoot intensity modulated radiation therapy., Med. Phys. 34 (10), 3962-3970 (2007). 10.1118/1.2776671 (Pubitemid 47482897)
    • (2007) Medical Physics , vol.34 , Issue.10 , pp. 3962-3970
    • Wiersma, R.D.1    Xing, L.2
  • 5
    • 54949136185 scopus 로고    scopus 로고
    • Dosimetric characteristics of linear accelerator photon beams with small monitor unit settings
    • 10.1118/1.2995759
    • S.-K. Kang, K.-H. Cheong, T. Hwang, B. C. Cho, S. S. Kim, K. J. Kim, D. H. Oh, H. Bae, and T.-S. Suh, Dosimetric characteristics of linear accelerator photon beams with small monitor unit settings., Med. Phys. 35 (11), 5172-5178 (2008). 10.1118/1.2995759
    • (2008) Med. Phys. , vol.35 , Issue.11 , pp. 5172-5178
    • Kang, S.-K.1    Cheong, K.-H.2    Hwang, T.3    Cho, B.C.4    Kim, S.S.5    Kim, K.J.6    Oh, D.H.7    Bae, H.8    Suh, T.-S.9
  • 6
    • 80855128874 scopus 로고    scopus 로고
    • Dynamic MLC leaf sequencing for integrated linear accelerator control systems
    • 10.1118/1.3651628
    • R. A. Popple and I. A. Brezovich, Dynamic MLC leaf sequencing for integrated linear accelerator control systems., Med. Phys. 38 (11), 6039-6045 (2011). 10.1118/1.3651628
    • (2011) Med. Phys. , vol.38 , Issue.11 , pp. 6039-6045
    • Popple, R.A.1    Brezovich, I.A.2
  • 7
    • 85024994025 scopus 로고    scopus 로고
    • The overshoot phenomenon in step-and-shoot IMRT delivery
    • 10.1120/1.1386508
    • G. A. Ezzell and S. Chungbin, The overshoot phenomenon in step-and-shoot IMRT delivery., J. Appl. Clin. Med. Phys. 2 (3), 138-148 (2001). 10.1120/1.1386508
    • (2001) J. Appl. Clin. Med. Phys. , vol.2 , Issue.3 , pp. 138-148
    • Ezzell, G.A.1    Chungbin, S.2
  • 8
    • 0032874911 scopus 로고    scopus 로고
    • AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams
    • DOI 10.1118/1.598691
    • P. R. Almond, R. J. Biggs, B. M. Coursey, W. F. Hanson, M. Saiful Huq, R. Nath, and D. W. O. Rogers, AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams., Med. Phys. 26 (9), 1847-1870 (1999). 10.1118/1.598691 (Pubitemid 29442268)
    • (1999) Medical Physics , vol.26 , Issue.9 , pp. 1847-1870
    • Almond, P.R.1    Biggs, P.J.2    Coursey, B.M.3    Hanson, W.F.4    Huq, M.S.5    Nath, R.6    Rogers, D.W.O.7
  • 10
    • 74949117960 scopus 로고    scopus 로고
    • Statistical power analyses using GPower 3.1: Tests for correlation and regression analyses
    • 10.3758/BRM.41.4.1149
    • F. Faul, E. Erdfelder, A. Buchner, and A. G. Lang, Statistical power analyses using GPower 3.1: Tests for correlation and regression analyses., Behav. Res. Methods 41, 1149-1160 (2009). 10.3758/BRM.41.4.1149
    • (2009) Behav. Res. Methods , vol.41 , pp. 1149-1160
    • Faul, F.1    Erdfelder, E.2    Buchner, A.3    Lang, A.G.4
  • 11
    • 0842306297 scopus 로고    scopus 로고
    • Deep inspiration breath hold and respiratory gating strategies for reducing organ motion in radiation treatment
    • DOI 10.1053/j.semradonc.2003.10.009
    • G. S. Mageras and E. Yorke, Deep inspiration breath hold and respiratory gating strategies for reducing organ motion in radiation treatment., Semin. Radiat. Oncol. 14 (1), 65-75 (2004). 10.1053/j.semradonc.2003.10.009 (Pubitemid 38168955)
    • (2004) Seminars in Radiation Oncology , vol.14 , Issue.1 , pp. 65-75
    • Mageras, G.S.1    Yorke, E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.