Intensity Modulated Radiation Therapy Collaborative Working Grou "," Int. J. Radiat. Oncol., Biol., Phys..
-
Intensity Modulated Radiation Therapy Collaborative Working Group. " Intensity-modulated radiotherapy: Current status and issues of interest.," Int. J. Radiat. Oncol., Biol., Phys. 51, 880-914 (2001).
-
(2001)
Intensity-modulated Radiotherapy: Current Status and Issues of Interest
, vol.51
, pp. 880-914
-
-
-
2
-
-
0041381126
-
-
Int. J. Radiat. Oncol., Biol., Phys..
-
J. Z. Wang, X. A. Li, W. D. D'Souza, and R. D. Stewart, " Impact of prolonged fraction delivery times on tumor control: A note of caution for intensity-modulated radiation therapy (IMRT).," Int. J. Radiat. Oncol., Biol., Phys. 57, 543-552 (2003).
-
(2003)
Impact of Prolonged Fraction Delivery Times on Tumor Control: A Note of Caution for Intensity-modulated Radiation Therapy (IMRT)
, vol.57
, pp. 543-552
-
-
Wang, J.Z.1
Li, X.A.2
D'Souza, W.D.3
Stewart, R.D.4
-
3
-
-
7444262310
-
-
Int. J. Radiat. Oncol., Biol., Phys..
-
J. F. Fowler, J. S. Welsh, and S. P. Howard, " Loss of biological effect in prolonged fraction delivery.," Int. J. Radiat. Oncol., Biol., Phys. 59, 242-249 (2004).
-
(2004)
Loss of Biological Effect in Prolonged Fraction Delivery
, vol.59
, pp. 242-249
-
-
Fowler, J.F.1
Welsh, J.S.2
Howard, S.P.3
-
4
-
-
34147188973
-
-
Med. Phys..
-
V. Moiseenko, C. Duzenli, and R. E. Durand, " In vitro study of cell survival following dynamic MLC intensity-modulated radiation therapy dose delivery.," Med. Phys. 34, 1514-1520 (2007).
-
(2007)
In Vitro Study of Cell Survival Following Dynamic MLC Intensity-modulated Radiation Therapy Dose Delivery
, vol.34
, pp. 1514-1520
-
-
Moiseenko, V.1
Duzenli, C.2
Durand, R.E.3
-
5
-
-
25844432193
-
-
Int. J. Radiat. Oncol., Biol., Phys..
-
H. Paganetti, " Changes in tumor cell response due to prolonged dose delivery times in fractionated radiation therapy.," Int. J. Radiat. Oncol., Biol., Phys. 63, 892-900 (2005).
-
(2005)
Changes in Tumor Cell Response Due to Prolonged Dose Delivery Times in Fractionated Radiation Therapy
, vol.63
, pp. 892-900
-
-
Paganetti, H.1
-
6
-
-
1542709578
-
-
Radiother. Oncol..
-
X. Mu, P. O. Loefroth, M. Karlsson, and B. Zackrisson, " The effect of fraction time in intensity modulated therapy: Theoretical and experimental evaluation of an optimization problem.," Radiother. Oncol. 68, 181-187 (2003).
-
(2003)
The Effect of Fraction Time in Intensity Modulated Therapy: Theoretical and Experimental Evaluation of An Optimization Problem
, vol.68
, pp. 181-187
-
-
Mu, X.1
Loefroth, P.O.2
Karlsson, M.3
Zackrisson, B.4
-
7
-
-
29144473278
-
-
Strahlenther. Onkol..
-
M. Ravikumar, M. A. Asmary, R. A. Sultan, and H. A. Ghamdi, " Dose delivery accuracy of therapeutic photon and electron beams at low monitor unit settings.," Strahlenther. Onkol. 181, 796-799 (2005).
-
(2005)
Dose Delivery Accuracy of Therapeutic Photon and Electron Beams at Low Monitor Unit Settings
, vol.181
, pp. 796-799
-
-
Ravikumar, M.1
Asmary, M.A.2
Sultan, R.A.3
Ghamdi, H.A.4
-
9
-
-
0034499349
-
-
Med. Phys..
-
M. B. Sharpe, B. M. Miller, D. Yan, and J. W. Wong, " Monitor unit settings for intensity modulated beams delivered using a step-and-shoot approach.," Med. Phys. 27, 2719-2725 (2000).
-
(2000)
Monitor Unit Settings for Intensity Modulated Beams Delivered Using a Step-and-shoot Approach
, vol.27
, pp. 2719-2725
-
-
Sharpe, M.B.1
Miller, B.M.2
Yan, D.3
Wong, J.W.4
-
11
-
-
0042388792
-
-
Med. Phys..
-
C. B. Saw, S. Li, and K. M. Ayyangar, " Dose linearity and uniformity of a linear accelerator designed for implementation of multileaf collimation system-based intensity modulated radiation therapy.," Med. Phys. 30, 2253-2256 (2003).
-
(2003)
Dose Linearity and Uniformity of a Linear Accelerator Designed for Implementation of Multileaf Collimation System-based Intensity Modulated Radiation Therapy
, vol.30
, pp. 2253-2256
-
-
Saw, C.B.1
Li, S.2
Ayyangar, K.M.3
-
12
-
-
0029976278
-
-
Med. Phys..
-
J. L. Humm, A. Larsson, and E. P. Lief, " Dosimetric properties of a scanned beam microtron at low monitor unit settings: Importance for conformal therapy.," Med. Phys. 23, 329-335 (1996).
-
(1996)
Dosimetric Properties of a Scanned Beam Microtron at Low Monitor Unit Settings: Importance for Conformal Therapy
, vol.23
, pp. 329-335
-
-
Humm, J.L.1
Larsson, A.2
Lief, E.P.3
-
13
-
-
0031696075
-
-
Phys. Med. Biol..
-
V. N. Hansen, P. M. Evans, G. J. Budgell, J. H. Mott, P. C. Williams, M. J. Brugmans, F. W. Wittkämper, B. J. Mijnheer, and K. Brown, " Quality assurance of the dose delivered by small radiation segments.," Phys. Med. Biol. 43, 2665-2675 (1998).
-
(1998)
Quality Assurance of the Dose Delivered by Small Radiation Segments
, vol.43
, pp. 2665-2675
-
-
Hansen, V.N.1
Evans, P.M.2
Budgell, G.J.3
Mott, J.H.4
Williams, P.C.5
Brugmans, M.J.6
Wittkämper, F.W.7
Mijnheer, B.J.8
Brown, K.9
-
15
-
-
27644436334
-
-
Med. Dosim..
-
M. M. Aspradakis, G. D. Lambert, and A. Steele, " Elements of commissioning step-and-shoot IMRT: Delivery equipment and planning system issues posed by small segment dimensions and small monitor units.," Med. Dosim. 30, 233-242 (2005).
-
(2005)
Elements of Commissioning Step-and-shoot IMRT: Delivery Equipment and Planning System Issues Posed by Small Segment Dimensions and Small Monitor Units
, vol.30
, pp. 233-242
-
-
Aspradakis, M.M.1
Lambert, G.D.2
Steele, A.3
-
16
-
-
0023485303
-
-
Med. Phys..
-
R. J. Barish, R. C. Fleischman, and Y. M. Pipman, " Teletherapy beam characteristics: The first second.," Med. Phys. 14, 657-661 (1987).
-
(1987)
Teletherapy Beam Characteristics: The First Second
, vol.14
, pp. 657-661
-
-
Barish, R.J.1
Fleischman, R.C.2
Pipman, Y.M.3
-
17
-
-
0028398587
-
-
Med. Dosim..
-
A. K. Sharma, S. S. Supe, N. Anantha, and K. Subbarangaiah, " Dosimetric accuracy of a dual photon energy linac at low monitor setting for various pulse repetition frequencies.," Med. Dosim. 19, 47-49 (1994).
-
(1994)
Dosimetric Accuracy of a Dual Photon Energy Linac at Low Monitor Setting for Various Pulse Repetition Frequencies
, vol.19
, pp. 47-49
-
-
Sharma, A.K.1
Supe, S.S.2
Anantha, N.3
Subbarangaiah, K.4
-
18
-
-
3042548119
-
-
Med. Phys..
-
A. M. Stell, J. G. Li, O. A. Zeidan, and J. F. Dempsey, " An extensive log-file analysis of step-and-shoot intensity modulated radiation therapy segment delivery errors.," Med. Phys. 31, 1593-1602 (2004).
-
(2004)
An Extensive Log-file Analysis of Step-and-shoot Intensity Modulated Radiation Therapy Segment Delivery Errors
, vol.31
, pp. 1593-1602
-
-
Stell, A.M.1
Li, J.G.2
Zeidan, O.A.3
Dempsey, J.F.4
-
19
-
-
1542603236
-
-
Radiother. Oncol..
-
D. Letourneau, M. Gulam, D. Yan, M. Oldham and J. W. Wong, " Evaluation of a 2D diode array for IMRT quality assurance.," Radiother. Oncol. 70, 199-206 (2004).
-
(2004)
Evaluation of a 2D Diode Array for IMRT Quality Assurance
, vol.70
, pp. 199-206
-
-
Letourneau, D.1
Gulam, M.2
Yan, D.3
Oldham, M.4
Wong, J.W.5
-
21
-
-
34548338107
-
-
Functional Requirements for IMRT," in, edited by J. R. Palta and T. R. Mackie, Medical Physics Monograph No. 29 (Medical Physics Publishing, Madison, WI, 2003)
-
T. J. Waldron, " Functional Requirements for IMRT.," in Intensity Modulated Radiation Therapy: State of the Art, edited by, J. R. Palta, and, T. R. Mackie, Medical Physics Monograph No. 29 (Medical Physics Publishing, Madison, WI, 2003), pp. 373-400.
-
Intensity Modulated Radiation Therapy: State of the Art
, pp. 373-400
-
-
Waldron, T.J.1
-
23
-
-
0036127055
-
-
Med. Phys..
-
P. Xia, C. F. Chuang, and L. J. Verhey, " Communication and sampling rate limitations in IMRT delivery with a dynamic multileaf collimator system.," Med. Phys. 29, 412-423 (2002).
-
(2002)
Communication and Sampling Rate Limitations in IMRT Delivery with a Dynamic Multileaf Collimator System
, vol.29
, pp. 412-423
-
-
Xia, P.1
Chuang, C.F.2
Verhey, L.J.3
-
24
-
-
31344462965
-
-
Phys. Med. Biol..
-
G. N. Grigorov, J. C. L. Chow, and R. B. Barnett, " Dosimetry limitations and a dose correction methodology for step-and-shoot IMRT.," Phys. Med. Biol. 51, 637-652 (2006).
-
(2006)
Dosimetry Limitations and a Dose Correction Methodology for Step-and-shoot IMRT
, vol.51
, pp. 637-652
-
-
Grigorov, G.N.1
Chow, J.C.L.2
Barnett, R.B.3
-
28
-
-
3442881436
-
-
Phys. Med. Biol..
-
J. D. Fenwick, W. A. Tome, H. A. Jaradat, S. K. Hui, J. A. James, J. P. Balog, C. N. DeSouza, D. B. Lucas, G. H. Olivera, T. R. Mackie, and B. R. Paliwal, " Quality assurance of a helical tomotherapy machine.," Phys. Med. Biol. 49, 2933-2953 (2004).
-
(2004)
Quality Assurance of a Helical Tomotherapy Machine
, vol.49
, pp. 2933-2953
-
-
Fenwick, J.D.1
Tome, W.A.2
Jaradat, H.A.3
Hui, S.K.4
James, J.A.5
Balog, J.P.6
Desouza, C.N.7
Lucas, D.B.8
Olivera, G.H.9
MacKie, T.R.10
Paliwal, B.R.11
|