메뉴 건너뛰기




Volumn 25, Issue 6, 2012, Pages 603-609

Flow characteristics of the SAPIEN aortic valve: The importance of recognizing in-stent flow acceleration for the echocardiographic assessment of valve function

Author keywords

Echocardiography; Transcatheter aortic valve

Indexed keywords

AGED; AORTA VALVE; AORTA VALVE PROSTHESIS; AORTA VALVE STENOSIS; ARTICLE; BLOOD FLOW; BLOOD FLOW VELOCITY; CLINICAL ARTICLE; CONTROLLED STUDY; DOPPLER ECHOCARDIOGRAPHY; FEMALE; HEART LEFT VENTRICLE OUTFLOW TRACT; HUMAN; MALE; STENT; TRANSCATHETER AORTIC VALVE IMPLANTATION;

EID: 84861578251     PISSN: 08947317     EISSN: 10976795     Source Type: Journal    
DOI: 10.1016/j.echo.2012.02.013     Document Type: Article
Times cited : (49)

References (18)
  • 1
    • 77649212932 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation for the treatment of severe symptomatic aortic stenosis in patients at very high or prohibitive surgical risk: Acute and late outcomes of the multicenter Canadian experience
    • J. Rodés-Cabau, J.G. Webb, A. Cheung, J. Ye, E. Dumont, and C.M. Feindel Transcatheter aortic valve implantation for the treatment of severe symptomatic aortic stenosis in patients at very high or prohibitive surgical risk: acute and late outcomes of the multicenter Canadian experience J Am Coll Cardiol 55 2010 1080 1090
    • (2010) J Am Coll Cardiol , vol.55 , pp. 1080-1090
    • Rodés-Cabau, J.1    Webb, J.G.2    Cheung, A.3    Ye, J.4    Dumont, E.5    Feindel, C.M.6
  • 2
    • 33644910414 scopus 로고    scopus 로고
    • Treatment of calcific aortic stenosis with the percutaneous heart valve: Mid-term follow-up from the initial feasibility studies: The French experience
    • A. Cribier, H. Eltchaninoff, C. Tron, F. Bauer, C. Agatiello, and D. Nercolini Treatment of calcific aortic stenosis with the percutaneous heart valve: mid-term follow-up from the initial feasibility studies: the French experience J Am Coll Cardiol 47 2006 1214 1223
    • (2006) J Am Coll Cardiol , vol.47 , pp. 1214-1223
    • Cribier, A.1    Eltchaninoff, H.2    Tron, C.3    Bauer, F.4    Agatiello, C.5    Nercolini, D.6
  • 4
    • 67649532220 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Impact on clinical and valve-related outcomes
    • J.G. Webb, L. Altwegg, R.H. Boone, A. Cheung, J. Ye, and S. Lichtenstein Transcatheter aortic valve implantation: impact on clinical and valve-related outcomes Circulation 119 2009 3009 3016
    • (2009) Circulation , vol.119 , pp. 3009-3016
    • Webb, J.G.1    Altwegg, L.2    Boone, R.H.3    Cheung, A.4    Ye, J.5    Lichtenstein, S.6
  • 5
    • 77957945557 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Durability of clinical and hemodynamic outcomes beyond 3 years in a large patient cohort
    • R. Gurvitch, D.A. Wood, E.L. Tay, J. Leipsic, J. Ye, and S.V. Lichtenstein Transcatheter aortic valve implantation: durability of clinical and hemodynamic outcomes beyond 3 years in a large patient cohort Circulation 122 2010 1319 1327
    • (2010) Circulation , vol.122 , pp. 1319-1327
    • Gurvitch, R.1    Wood, D.A.2    Tay, E.L.3    Leipsic, J.4    Ye, J.5    Lichtenstein, S.V.6
  • 7
    • 78549256704 scopus 로고    scopus 로고
    • Comparison between transcatheter and surgical prosthetic valve implantation in patients with severe aortic stenosis and reduced left ventricular ejection fraction
    • M.A. Clavel, J.G. Webb, J. Rodes-Cabau, J.B. Masson, E. Dumont, and R. De Larochelliere Comparison between transcatheter and surgical prosthetic valve implantation in patients with severe aortic stenosis and reduced left ventricular ejection fraction Circulation 122 2010 1928 1936
    • (2010) Circulation , vol.122 , pp. 1928-1936
    • Clavel, M.A.1    Webb, J.G.2    Rodes-Cabau, J.3    Masson, J.B.4    Dumont, E.5    De Larochelliere, R.6
  • 8
    • 77958594295 scopus 로고    scopus 로고
    • Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery
    • M.B. Leon, C.R. Smith, M. Mack, D.C. Miller, J.W. Moses, and L.G. Svensson Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery N Engl J Med 363 2010 1597 1607
    • (2010) N Engl J Med , vol.363 , pp. 1597-1607
    • Leon, M.B.1    Smith, C.R.2    MacK, M.3    Miller, D.C.4    Moses, J.W.5    Svensson, L.G.6
  • 10
    • 78449247508 scopus 로고    scopus 로고
    • Outcomes after transcatheter aortic valve implantation with both Edwards-SAPIEN and CoreValve devices in a single center: The Milan experience
    • C. Godino, F. Maisano, M. Montorfano, A. Latib, A. Chieffo, and I. Michev Outcomes after transcatheter aortic valve implantation with both Edwards-SAPIEN and CoreValve devices in a single center: the Milan experience J Am Coll Cardiol Intv 3 2010 1110 1121
    • (2010) J Am Coll Cardiol Intv , vol.3 , pp. 1110-1121
    • Godino, C.1    Maisano, F.2    Montorfano, M.3    Latib, A.4    Chieffo, A.5    Michev, I.6
  • 11
    • 78651469380 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation: Early results of the FRANCE (French Aortic National CoreValve and Edwards) registry
    • H. Eltchaninoff, A. Prat, M. Gilard, A. Leguerrier, D. Blanchard, and G.R. Fournial Transcatheter aortic valve implantation: early results of the FRANCE (French Aortic National CoreValve and Edwards) registry Eur Heart J 32 2011 191 197
    • (2011) Eur Heart J , vol.32 , pp. 191-197
    • Eltchaninoff, H.1    Prat, A.2    Gilard, M.3    Leguerrier, A.4    Blanchard, D.5    Fournial, G.R.6
  • 12
    • 55849132881 scopus 로고    scopus 로고
    • Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) CoreValve ReValving System: Results from the multicentre, expanded evaluation registry 1-year following CE mark approval
    • N. Piazza, E. Grube, U. Gerckens, P. den Heijer, A. Linke, and O. Luha Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) CoreValve ReValving System: results from the multicentre, expanded evaluation registry 1-year following CE mark approval Eurointervention 4 2008 242 249
    • (2008) Eurointervention , vol.4 , pp. 242-249
    • Piazza, N.1    Grube, E.2    Gerckens, U.3    Den Heijer, P.4    Linke, A.5    Luha, O.6
  • 13
    • 69549087044 scopus 로고    scopus 로고
    • Recommendations for evaluation of prosthetic valves with echocardiography and Doppler ultrasound
    • A report from the American Society of Echocardiography's Guidelines and Standards Committee and the Task Force on Prosthetic Valves, developed in conjunction with the American College of Cardiology Cardiovascular Imaging Committee, Cardiac Imaging Committee of the American Heart Association, the European Association of Echocardiography, a registered branch of the European Society of Cardiology, the Japanese Society of Echocardiography and the Canadian Society of Echocardiography, endorsed by the American College of Cardiology Foundation, American Heart Association, European Association of Echocardiography, a registered branch of the European Society of Cardiology, the Japanese Society of Echocardiography, and Canadian Society of Echocardiography
    • W.A. Zoghbi, J.B. Chambers, J.G. Dumesnil, E. Foster, J.S. Gottdiener, and P.A. Grayburn Recommendations for evaluation of prosthetic valves with echocardiography and Doppler ultrasound: a report from the American Society of Echocardiography's Guidelines and Standards Committee and the Task Force on Prosthetic Valves, developed in conjunction with the American College of Cardiology Cardiovascular Imaging Committee, Cardiac Imaging Committee of the American Heart Association, the European Association of Echocardiography, a registered branch of the European Society of Cardiology, the Japanese Society of Echocardiography and the Canadian Society of Echocardiography, endorsed by the American College of Cardiology Foundation, American Heart Association, European Association of Echocardiography, a registered branch of the European Society of Cardiology, the Japanese Society of Echocardiography, and Canadian Society of Echocardiography J Am Soc Echocardiogr 22 2009 975 1014
    • (2009) J Am Soc Echocardiogr , vol.22 , pp. 975-1014
    • Zoghbi, W.A.1    Chambers, J.B.2    Dumesnil, J.G.3    Foster, E.4    Gottdiener, J.S.5    Grayburn, P.A.6
  • 14
    • 80054105495 scopus 로고    scopus 로고
    • Validation and characterization of transcatheter aortic valve effective orifice area measured by Doppler echocardiography
    • M.-A. Clavel, J. Rodes-Cabau, E. Dumont, R. Bagur, S. Bergeron, and R. De Larochelliere Validation and characterization of transcatheter aortic valve effective orifice area measured by Doppler echocardiography J Am Coll Cardiol Img 4 2011 1053 1062
    • (2011) J Am Coll Cardiol Img , vol.4 , pp. 1053-1062
    • Clavel, M.-A.1    Rodes-Cabau, J.2    Dumont, E.3    Bagur, R.4    Bergeron, S.5    De Larochelliere, R.6
  • 15
  • 16
    • 0024466667 scopus 로고
    • Continuous wave Doppler echocardiographic measurement of prosthetic valve gradients: A simultaneous Doppler-catheter correlative study
    • D. Burstow, R. Nishimura, K. Bailey, G. Reeder, D. Holmes Jr., and J. Seward Continuous wave Doppler echocardiographic measurement of prosthetic valve gradients. A simultaneous Doppler-catheter correlative study Circulation 80 1989 504 514 (Pubitemid 19231384)
    • (1989) Circulation , vol.80 , Issue.3 , pp. 504-514
    • Burstow, D.J.1    Nishimura, R.A.2    Bailey, K.R.3    Reeder, G.S.4    Holmes Jr., D.R.5    Seward, J.B.6    Tajik, A.J.7
  • 18
    • 80052866006 scopus 로고    scopus 로고
    • The year in valvular heart disease
    • S.H. Rahimtoola The year in valvular heart disease J Am Coll Cardiol 58 2011 1197 1207
    • (2011) J Am Coll Cardiol , vol.58 , pp. 1197-1207
    • Rahimtoola, S.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.