메뉴 건너뛰기




Volumn 168, Issue , 2012, Pages 62-73

Miniaturized F --selective all-solid-state potentiometric sensors with conductive polymer as an intermediate layer

Author keywords

Fluoride selective electrode; Polyurethane membrane; Potentiometric sensor; Solid state sensor

Indexed keywords

ALL-SOLID-STATE POTENTIOMETRIC SENSORS; CONDUCTIVE POLYMER; FLUORIDE-SELECTIVE ELECTRODE; FLUORIDE-SELECTIVE MEMBRANES; FLUORIDE-SELECTIVE SENSORS; INTERMEDIATE LAYERS; INTERNAL ELECTRODES; IONIC ADDITIVES; MEMBRANE COMPONENTS; MEMBRANE MATRIX; MEMBRANE PREPARATION; PEDOT:PSS; PLASTICIZED PVC; POLY (VINYL CHLORIDE) MEMBRANE; POLY(STYRENE SULFONATE); POLY-3 ,4-ETHYLENEDIOXYTHIOPHENE; POLYMER MEMBRANE; POLYURETHANE MEMBRANES; STANDARD POTENTIAL; WORKING PARAMETERS;

EID: 84861575673     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2012.01.026     Document Type: Article
Times cited : (10)

References (36)
  • 1
    • 0014026177 scopus 로고
    • Electrode for sensing fluoride ion activity in solution
    • M.S. Frant, and J.P. Ross Electrode for sensing fluoride ion activity in solution Science 154 1966 1553 1555
    • (1966) Science , vol.154 , pp. 1553-1555
    • Frant, M.S.1    Ross, J.P.2
  • 3
    • 77951162322 scopus 로고    scopus 로고
    • Fluoride-selective polymeric membrane electrodes based on Zr(IV)- and Al(III)-salen ionophores of various structures
    • Ł. Górski, A. Matusevich, P. Parzuchowski, I. Łuciuk, and E. Malinowska Fluoride-selective polymeric membrane electrodes based on Zr(IV)- and Al(III)-salen ionophores of various structures Analytica Chimica Acta 665 2010 39 46
    • (2010) Analytica Chimica Acta , vol.665 , pp. 39-46
    • Górski, Ł.1    Matusevich, A.2    Parzuchowski, P.3    Łuciuk, I.4    Malinowska, E.5
  • 4
    • 58249131938 scopus 로고    scopus 로고
    • Complexes of tetra-tert-butyl-tetraazaporphine with Al(III) and Zr(IV) cations as fluoride selective ionophores
    • Ł. Górski, M. Mroczkiewicz, M. Pietrzak, and E. Malinowska Complexes of tetra-tert-butyl-tetraazaporphine with Al(III) and Zr(IV) cations as fluoride selective ionophores Analytica Chimica Acta 633 2009 181 187
    • (2009) Analytica Chimica Acta , vol.633 , pp. 181-187
    • Górski, Ł.1    Mroczkiewicz, M.2    Pietrzak, M.3    Malinowska, E.4
  • 5
    • 0042234023 scopus 로고    scopus 로고
    • Miniaturized sodium-selective sensors based on silicon back-side contact structure with novel self-plasticizing ion-selective membranes
    • K. Wygladacz, M. Durnaś, P. Parzuchowski, Z. Brzózka, and E. Malinowska Miniaturized sodium-selective sensors based on silicon back-side contact structure with novel self-plasticizing ion-selective membranes Sensors and Actuators B 95 2003 366 372
    • (2003) Sensors and Actuators B , vol.95 , pp. 366-372
    • Wygladacz, K.1    Durnaś, M.2    Parzuchowski, P.3    Brzózka, Z.4    Malinowska, E.5
  • 6
    • 0002797481 scopus 로고    scopus 로고
    • Producing 'self-plasticizing' ion-selective membranes
    • L.Y. Heng, and E.A. Hall Producing 'self-plasticizing' ion-selective membranes Analytical Chemistry 72 2000 42 51
    • (2000) Analytical Chemistry , vol.72 , pp. 42-51
    • Heng, L.Y.1    Hall, E.A.2
  • 7
    • 0034699596 scopus 로고    scopus 로고
    • Novel approach of immobilization of calix[4] arene type ionophore in 'self-plasticized' polymeric membrane
    • E. Malinowska, L. Gawart, P. Parzuchowski, G. Rokicki, and Z. Brzózka Novel approach of immobilization of calix[4] arene type ionophore in 'self-plasticized' polymeric membrane Analytica Chimica Acta 421 2000 93 101
    • (2000) Analytica Chimica Acta , vol.421 , pp. 93-101
    • Malinowska, E.1    Gawart, L.2    Parzuchowski, P.3    Rokicki, G.4    Brzózka, Z.5
  • 8
    • 0033652852 scopus 로고    scopus 로고
    • +-selective methacrylic-acrylic copolymers containing grafted ionophore and requiring no plasticizer
    • +-selective methacrylic-acrylic copolymers containing grafted ionophore and requiring no plasticizer Electroanalysis 12 2000 178 186
    • (2000) Electroanalysis , vol.12 , pp. 178-186
    • Lee, Y.H.1    Hall, E.A.H.2
  • 10
    • 0035932552 scopus 로고    scopus 로고
    • Potentiometric and spectroscopic characterization of anion selective electrodes based on metal(III) porphyrin ionophores in polyurethane membranes
    • E. Malinowska, J. Niedziółka, and M.E. Meyerhoff Potentiometric and spectroscopic characterization of anion selective electrodes based on metal(III) porphyrin ionophores in polyurethane membranes Analytica Chimica Acta 432 2001 67 78
    • (2001) Analytica Chimica Acta , vol.432 , pp. 67-78
    • Malinowska, E.1    Niedziółka, J.2    Meyerhoff, M.E.3
  • 11
    • 0037086664 scopus 로고    scopus 로고
    • Design of miniaturized nitrite sensors based on silicon structure with back-side contacts
    • K. Wygladacz, E. Malinowska, J. Jaźwiński, and Z. Brzózka Design of miniaturized nitrite sensors based on silicon structure with back-side contacts Sensors and Actuators B 83 2002 109 114
    • (2002) Sensors and Actuators B , vol.83 , pp. 109-114
    • Wygladacz, K.1    Malinowska, E.2    Jaźwiński, J.3    Brzózka, Z.4
  • 12
    • 18844362101 scopus 로고    scopus 로고
    • Fluoride-selective sensors based on polyurethane membranes doped with Zr(IV)-porphyrins
    • Ł. Górski, and E. Malinowska Fluoride-selective sensors based on polyurethane membranes doped with Zr(IV)-porphyrins Analytica Chimica Acta 540 2005 159 165
    • (2005) Analytica Chimica Acta , vol.540 , pp. 159-165
    • Górski, Ł.1    Malinowska, E.2
  • 13
    • 0141504460 scopus 로고    scopus 로고
    • Optimization of the composition of interfaces in miniature planar chloride electrodes
    • R. Paciorek, P.D. van der Wal, N.F. de Rooij, and M. Maj-Żurawska Optimization of the composition of interfaces in miniature planar chloride electrodes Electroanalysis 15 2003 1314 1318
    • (2003) Electroanalysis , vol.15 , pp. 1314-1318
    • Paciorek, R.1    Van Der Wal, P.D.2    De Rooij, N.F.3    Maj-Zurawska, M.4
  • 14
  • 17
    • 39449110385 scopus 로고    scopus 로고
    • Ion-selective electrodes using carbon nanotubes as ion-to-electron transducers
    • G.A. Crespo, S. Macho, and F.X. Rius Ion-selective electrodes using carbon nanotubes as ion-to-electron transducers Analytical Chemistry 80 2008 1316 1322
    • (2008) Analytical Chemistry , vol.80 , pp. 1316-1322
    • Crespo, G.A.1    MacHo, S.2    Rius, F.X.3
  • 18
    • 15944393877 scopus 로고    scopus 로고
    • Synthesis, characterization, and complexation of tetraarylborates with aromatic cations and their use in chemical sensors
    • T. Alaviuhkola, J. Bobacka, M. Nissinen, K. Rissanen, A. Ivaska, and J. Pursiainen Synthesis, characterization, and complexation of tetraarylborates with aromatic cations and their use in chemical sensors Chemistry - A European Journal 11 2005 2071 2080
    • (2005) Chemistry - A European Journal , vol.11 , pp. 2071-2080
    • Alaviuhkola, T.1    Bobacka, J.2    Nissinen, M.3    Rissanen, K.4    Ivaska, A.5    Pursiainen, J.6
  • 19
    • 30944444781 scopus 로고    scopus 로고
    • Conducting polymer-based solid-state ion-selective electrodes
    • J. Bobacka Conducting polymer-based solid-state ion-selective electrodes Electroanalysis 18 2006 7 18
    • (2006) Electroanalysis , vol.18 , pp. 7-18
    • Bobacka, J.1
  • 20
    • 67650572700 scopus 로고    scopus 로고
    • Poly(3,4-ethylenedioxythiophene) (PEDOT) doped with carbon nanotubes as ion-to-electron transducer in polymer membrane-based potassium ion-selective electrodes
    • Z. Mousavi, J. Bobacka, A. Lewenstam, and A. Ivaska Poly(3,4- ethylenedioxythiophene) (PEDOT) doped with carbon nanotubes as ion-to-electron transducer in polymer membrane-based potassium ion-selective electrodes Journal of Electroanalytical Chemistry 633 2009 246 252
    • (2009) Journal of Electroanalytical Chemistry , vol.633 , pp. 246-252
    • Mousavi, Z.1    Bobacka, J.2    Lewenstam, A.3    Ivaska, A.4
  • 22
    • 29544444766 scopus 로고    scopus 로고
    • Optimizing the analytical performance and construction of ion-selective electrodes with conducting polymer-based ion-to-electron transducers
    • A. Michalska Optimizing the analytical performance and construction of ion-selective electrodes with conducting polymer-based ion-to-electron transducers Analytical and Bioanalytical Chemistry 384 2006 391 406
    • (2006) Analytical and Bioanalytical Chemistry , vol.384 , pp. 391-406
    • Michalska, A.1
  • 26
    • 18544412959 scopus 로고    scopus 로고
    • Polymeric membrane electrodes with enhanced fluoride selectivity using Zr(IV)-porphyrins functioning as neutral carriers
    • Ł. Górski, M.E. Meyerhoff, and E. Malinowska Polymeric membrane electrodes with enhanced fluoride selectivity using Zr(IV)-porphyrins functioning as neutral carriers Talanta 63 2004 101 107
    • (2004) Talanta , vol.63 , pp. 101-107
    • Górski, Ł.1    Meyerhoff, M.E.2    Malinowska, E.3
  • 28
    • 0342369367 scopus 로고    scopus 로고
    • Cationic or anionic sites? Selectivity optimization of ion-selective electrodes based on charged ionophores
    • S. Amemiya, P. Bülmann, E. Pretsch, B. Rusterholz, and Y. Umezawa Cationic or anionic sites? Selectivity optimization of ion-selective electrodes based on charged ionophores Analytical Chemistry 72 2000 1618 1631
    • (2000) Analytical Chemistry , vol.72 , pp. 1618-1631
    • Amemiya, S.1    Bülmann, P.2    Pretsch, E.3    Rusterholz, B.4    Umezawa, Y.5
  • 29
    • 0000020499 scopus 로고
    • Anion-selective membrane electrodes based on metalloporphyrins: The influence of lipophilic anionic and cationic sites on potentiometric selectivity
    • E. Bakker, E. Malinowska, R.D. Schiller, and M.E. Meyerhoff Anion-selective membrane electrodes based on metalloporphyrins: the influence of lipophilic anionic and cationic sites on potentiometric selectivity Talanta 41 1994 881 890
    • (1994) Talanta , vol.41 , pp. 881-890
    • Bakker, E.1    Malinowska, E.2    Schiller, R.D.3    Meyerhoff, M.E.4
  • 33
    • 65549111703 scopus 로고    scopus 로고
    • Metalloporphyrin-based acetate-selective electrodes as detectors for enzymatic acetylcholine determination in flow-injection analysis system
    • Ł. Górski, M. Mroczkiewicz, M. Pietrzak, and E. Malinowska Metalloporphyrin-based acetate-selective electrodes as detectors for enzymatic acetylcholine determination in flow-injection analysis system Analytica Chimica Acta 644 2009 30 35
    • (2009) Analytica Chimica Acta , vol.644 , pp. 30-35
    • Górski, Ł.1    Mroczkiewicz, M.2    Pietrzak, M.3    Malinowska, E.4
  • 34
    • 0037877980 scopus 로고    scopus 로고
    • Potentiometric ion sensors based on conducting polymers
    • J. Bobacka, A. Ivaska, and A. Lewenstam Potentiometric ion sensors based on conducting polymers Electroanalysis 15 2003 366 374
    • (2003) Electroanalysis , vol.15 , pp. 366-374
    • Bobacka, J.1    Ivaska, A.2    Lewenstam, A.3
  • 35
    • 0141924478 scopus 로고    scopus 로고
    • Lowering the detection limit of ion-selective plastic membrane electrodes with conducting polymer solid contact and conducting polymer potentiometric sensors
    • A. Michalska, J. Dumańska, and K. Maksymiuk Lowering the detection limit of ion-selective plastic membrane electrodes with conducting polymer solid contact and conducting polymer potentiometric sensors Analytical Chemistry 75 2003 4964 4974
    • (2003) Analytical Chemistry , vol.75 , pp. 4964-4974
    • Michalska, A.1    Dumańska, J.2    Maksymiuk, K.3
  • 36
    • 0033661549 scopus 로고    scopus 로고
    • Potential drifts of solid-contacted ion-selective electrodes due to zero-current ion fluxes through the sensor membrane
    • M. Fibbioli, W.E. Morf, M. Badertscher, N.F. de Rooij, and E. Pretsch Potential drifts of solid-contacted ion-selective electrodes due to zero-current ion fluxes through the sensor membrane Electroanalysis 12 2000 1286 1292
    • (2000) Electroanalysis , vol.12 , pp. 1286-1292
    • Fibbioli, M.1    Morf, W.E.2    Badertscher, M.3    De Rooij, N.F.4    Pretsch, E.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.