메뉴 건너뛰기




Volumn 8, Issue 1, 1999, Pages 34-41

Distortion of the stentless porcine valve induces accelerated leaflet fibrosis and calcification in juvenile sheep

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL MODEL; ARTICLE; ATOMIC ABSORPTION SPECTROMETRY; BIOCOMPATIBILITY; CALCIFICATION; FIBROSIS; HEART VALVE BIOPROSTHESIS; HYDRODYNAMICS; NONHUMAN; PRIORITY JOURNAL; SCANNING ELECTRON MICROSCOPY; SHEEP; TRANSMISSION ELECTRON MICROSCOPY;

EID: 0033027393     PISSN: 09668519     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (21)

References (21)
  • 1
    • 0007518709 scopus 로고
    • Calcification as the main cause of porcine bioprosthetic dysfunction
    • Milano A, Bortolotti U, Talenti E, et al. Calcification as the main cause of porcine bioprosthetic dysfunction. Am J Cardiol 1984;53:1006-1070
    • (1984) Am J Cardiol , vol.53 , pp. 1006-1070
    • Milano, A.1    Bortolotti, U.2    Talenti, E.3
  • 2
    • 0024474797 scopus 로고
    • Evaluation of prosthetic valves by Doppler echocardiography
    • Heldman D, Gardin JM. Evaluation of prosthetic valves by Doppler echocardiography. Echocardiography 1989;6:63-77
    • (1989) Echocardiography , vol.6 , pp. 63-77
    • Heldman, D.1    Gardin, J.M.2
  • 3
    • 0020672204 scopus 로고
    • Calcification of glutaraldehyde-preserved porcine and bovine xenograft in young children
    • Fiddler GI, Gerlis LM, Walker DR. Calcification of glutaraldehyde-preserved porcine and bovine xenograft in young children. Ann Thorac Surg 1983;35:257-264
    • (1983) Ann Thorac Surg , vol.35 , pp. 257-264
    • Fiddler, G.I.1    Gerlis, L.M.2    Walker, D.R.3
  • 4
    • 0026329244 scopus 로고
    • Stress reduction in bioprosthetic heart valve leaflets by the use of a flexible stent
    • Christie GW, Barratt-Boyes BG. Stress reduction in bioprosthetic heart valve leaflets by the use of a flexible stent. J Card Surg 1992;6:476-481
    • (1992) J Card Surg , vol.6 , pp. 476-481
    • Christie, G.W.1    Barratt-Boyes, B.G.2
  • 5
    • 0028110091 scopus 로고
    • Aortic valve replacement with a stentless porcine aortic valve: A six years experience
    • David TE, Feindel CM, Bos J, et al. Aortic valve replacement with a stentless porcine aortic valve: A six years experience. J Thorac Cardiovasc Surg 1994;108:1030-1036
    • (1994) J Thorac Cardiovasc Surg , vol.108 , pp. 1030-1036
    • David, T.E.1    Feindel, C.M.2    Bos, J.3
  • 6
    • 0023755406 scopus 로고
    • Tissue buckling as a mechanism of bioprosthetic valve failure
    • Vesely I, Boughner D, Song T. Tissue buckling as a mechanism of bioprosthetic valve failure. Ann Thorac Surg 1988;46:302-308
    • (1988) Ann Thorac Surg , vol.46 , pp. 302-308
    • Vesely, I.1    Boughner, D.2    Song, T.3
  • 7
    • 0344922083 scopus 로고    scopus 로고
    • Implantation technique for the Toronto SPV bioprosthesis
    • Piwnica A, Westaby S (ed). Isis Medical Media, Oxford
    • David TE. Implantation technique for the Toronto SPV bioprosthesis. In Piwnica A, Westaby S (ed). Surgery for Acquired Aortic Valve Disease. Isis Medical Media, Oxford, 1997:102-109
    • (1997) Surgery for Acquired Aortic Valve Disease , pp. 102-109
    • David, T.E.1
  • 10
    • 0025082325 scopus 로고
    • Estimation of shear stress-related blood damage in heart valve prostheses - In vitro comparison of 25 aortic valves
    • Geirsiepen M, Wurzinger LJ, Opitz R, Reul H. Estimation of shear stress-related blood damage in heart valve prostheses - in vitro comparison of 25 aortic valves. Int J Artif Org 1990;13:300-305
    • (1990) Int J Artif Org , vol.13 , pp. 300-305
    • Geirsiepen, M.1    Wurzinger, L.J.2    Opitz, R.3    Reul, H.4
  • 12
    • 0029118130 scopus 로고
    • Aortic valve replacement: Is the stentless xenograft an alternative to the homograft ? Early results of a randomized study
    • Gross CH, Harringer W, Mair R, et al. Aortic valve replacement: Is the stentless xenograft an alternative to the homograft ? Early results of a randomized study. Ann Thorac Surg 1995;60:418-421
    • (1995) Ann Thorac Surg , vol.60 , pp. 418-421
    • Gross, C.H.1    Harringer, W.2    Mair, R.3
  • 14
    • 0024308401 scopus 로고
    • An assessment of the mechanical properties of leaflets from four second-generation porcine bioprostheses with biaxial testing technique
    • Mayne AS, Christie GW, Smaill BH, Hunter PJ, Barrat-Boyes CM. An assessment of the mechanical properties of leaflets from four second-generation porcine bioprostheses with biaxial testing technique. J Thorac Cardiovasc Surg 1989;98:170-180
    • (1989) J Thorac Cardiovasc Surg , vol.98 , pp. 170-180
    • Mayne, A.S.1    Christie, G.W.2    Smaill, B.H.3    Hunter, P.J.4    Barrat-Boyes, C.M.5
  • 17
  • 18
    • 0022553648 scopus 로고
    • Mechanical stresses on closed cusp of porcine bioprosthetic valves: Correlation with sites of calcification
    • Sabbah HN, Hamid MS, Stein PD. Mechanical stresses on closed cusp of porcine bioprosthetic valves: Correlation with sites of calcification. Ann Thorac Surg 1986;42:92-96
    • (1986) Ann Thorac Surg , vol.42 , pp. 92-96
    • Sabbah, H.N.1    Hamid, M.S.2    Stein, P.D.3
  • 20
    • 0023157520 scopus 로고
    • The behavior of pericardial versus porcine valve xenografts in the growing sheep model
    • Gallo I, Nistal F, Artinano E, et al. The behavior of pericardial versus porcine valve xenografts in the growing sheep model. J Thorac Cardiovasc Surg 1987;93:281-290
    • (1987) J Thorac Cardiovasc Surg , vol.93 , pp. 281-290
    • Gallo, I.1    Nistal, F.2    Artinano, E.3
  • 21
    • 0028148208 scopus 로고
    • Onset and progression of calcification in porcine aortic bioprosthetic valves implanted as orthotopic mitral valve replacements in juvenile sheep
    • Schoen FJ, Hirsch D, Bianco RW, Levy RJ. Onset and progression of calcification in porcine aortic bioprosthetic valves implanted as orthotopic mitral valve replacements in juvenile sheep. J Thorac Cardiovasc Surg 1994;108:880-887
    • (1994) J Thorac Cardiovasc Surg , vol.108 , pp. 880-887
    • Schoen, F.J.1    Hirsch, D.2    Bianco, R.W.3    Levy, R.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.