메뉴 건너뛰기




Volumn , Issue , 2012, Pages 204-207

An optical diagnostic system using isothermal amplification technique for Phalaenopsis orchids

Author keywords

loop mediated isothermal amplification (LAMP); microfluidics; Phalaenopsis orchid

Indexed keywords

AMPLIFICATION TECHNIQUE; AUTOMATIC DETECTION; INFECTIOUS DISEASE; INTEGRATED MICROFLUIDIC SYSTEMS; LOOP-MEDIATED-ISOTHERMAL-AMPLIFICATION (LAMP); MOSAIC VIRUS; OPTICAL DETECTION; OPTICAL DIAGNOSTIC SYSTEMS; PHALAENOPSIS; REVERSE TRANSCRIPTION; SINGLE CHIPS; TURBIDITY CHANGES;

EID: 84861542459     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NEMS.2012.6196757     Document Type: Conference Paper
Times cited : (1)

References (8)
  • 1
    • 0033047233 scopus 로고    scopus 로고
    • Detection of Cymbidium mosaic potexvirus and Odontoglossum ringspot tobamovirus using immuno-capillary zone electrophoresis
    • A.J.C. Eun, S.M. Wong, " Detection of Cymbidium mosaic potexvirus and Odontoglossum ringspot tobamovirus using immuno-capillary zone electrophoresis." Phytopathology, vol. 89, pp. 522-528, 1999.
    • (1999) Phytopathology , vol.89 , pp. 522-528
    • Eun, A.J.C.1    Wong, S.M.2
  • 2
    • 0031749790 scopus 로고    scopus 로고
    • Simultaneous TD/RT-PCR detection of cymbidium mosaic potexvirus and odontoglossum ringspot tobamovirus with a single pair of primer
    • M.L. Seoh, S.M. Wong, L. Zhang, "Simultaneous TD/RT-PCR detection of cymbidium mosaic potexvirus and odontoglossum ringspot tobamovirus with a single pair of primer", J. Virol. Methods,vol. 72, pp. 197-204, 1998.
    • (1998) J. Virol. Methods , vol.72 , pp. 197-204
    • Seoh, M.L.1    Wong, S.M.2    Zhang, L.3
  • 3
    • 84861536044 scopus 로고    scopus 로고
    • A magnetic bead-based assay for the rapid detection of methicillin-resistant Staphylococcus aureus by using a microfluidic system with integrated loopmediated isothermal amplification
    • C. H. Wang, K.Y. Lien, J.J. Wu, G.B. Lee, "A magnetic bead-based assay for the rapid detection of methicillin-resistant Staphylococcus aureus by using a microfluidic system with integrated loopmediated isothermal amplification", Lab. Chip., vol. 173, pp. 43-48, 2011.
    • (2011) Lab. Chip. , vol.173 , pp. 43-48
    • Wang, C.H.1    Lien, K.Y.2    Wu, J.J.3    Lee, G.B.4
  • 5
    • 33750321228 scopus 로고    scopus 로고
    • Use of reverse transcription loop-mediated isothermal amplification for the detection of Plum pox virus
    • A. Varga, D. James, "Use of reverse transcription loop-mediated isothermal amplification for the detection of Plum pox virus", J. Virol. Methods, vol. 138, pp.184-190, 2006.
    • (2006) J. Virol. Methods , vol.138 , pp. 184-190
    • Varga, A.1    James, D.2
  • 6
    • 79952194159 scopus 로고    scopus 로고
    • One-step reverse transcription loop-mediated isothermal amplification assay for rapid detection of Cymbidium mosaic virus
    • M.S. Lee, M.J. Yang, Y.C. Hseu, G.H. Lai, W.T. Chang, Y.H. Hsu, M.K.Lin, "One-step reverse transcription loop-mediated isothermal amplification assay for rapid detection of Cymbidium mosaic virus", J. Virol. Methods,vol. 173, pp. 43-48, 2011.
    • (2011) J. Virol. Methods , vol.173 , pp. 43-48
    • Lee, M.S.1    Yang, M.J.2    Hseu, Y.C.3    Lai, G.H.4    Chang, W.T.5    Hsu, Y.H.6    Lin, M.K.7
  • 7
    • 77950436747 scopus 로고    scopus 로고
    • Loop-mediated isothermal amplification integrated on micro fluidic chips for point-of-care quantitative detection of pathogens
    • X. Fang, Y. Liu, J. Kong, X. Jiang, "Loop-mediated isothermal amplification integrated on micro fluidic chips for point-of-care quantitative detection of pathogens", Anal. Chem., vol. 82, pp.3002-3006, 2011.
    • (2011) Anal. Chem. , vol.82 , pp. 3002-3006
    • Fang, X.1    Liu, Y.2    Kong, J.3    Jiang, X.4
  • 8
    • 78650602536 scopus 로고    scopus 로고
    • An integrated microfluidic loop-mediated-isothermal-amplification system for rapid sample pre-treatment and detection of viruses
    • C.H. Wang, K.Y. Lien, T.Y. Wang, T.Y. Chen, G.B. Lee, "An integrated microfluidic loop-mediated-isothermal-amplification system for rapid sample pre-treatment and detection of viruses", Biosens. Bioelectron., vol. 26, pp. 2045-2052, 2011.
    • (2011) Biosens. Bioelectron. , vol.26 , pp. 2045-2052
    • Wang, C.H.1    Lien, K.Y.2    Wang, T.Y.3    Chen, T.Y.4    Lee, G.B.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.