메뉴 건너뛰기




Volumn 12, Issue 5, 2012, Pages 6404-6414

Integral T-shaped phantom-dosimeter system to measure transverse and longitudinal dose distributions simultaneously for stereotactic radiosurgery dosimetry

Author keywords

Absorbed dose; Fiber optic dosimeter; Phantom; Radiosurgery; Square scintillating optical fiber

Indexed keywords

ARTICLE; IMAGE QUALITY; RADIATION DOSE; RADIOSURGERY;

EID: 84861541408     PISSN: 14248220     EISSN: None     Source Type: Journal    
DOI: 10.3390/s120506404     Document Type: Article
Times cited : (10)

References (19)
  • 1
    • 0342614959 scopus 로고    scopus 로고
    • Miniature scintillating detector for small field radiation therapy
    • Letourneau, D.; Pouliot, J.; Roy, R. Miniature scintillating detector for small field radiation therapy. Med. Phys. 1999, 26, 2555-2661.
    • (1999) Med. Phys. , vol.26 , pp. 2555-2661
    • Letourneau, D.1    Pouliot, J.2    Roy, R.3
  • 2
    • 0035355339 scopus 로고    scopus 로고
    • A miniature scintillator-fiberoptic-PMT detector system for the dosimetry of small fields in stereotactic radiosurgery
    • Beddar, A.S.; Kinsella, T.J.; Ikhlef, A.; Sibata, C.H. A miniature scintillator-fiberoptic-PMT detector system for the dosimetry of small fields in stereotactic radiosurgery. IEEE Trans. Nucl. Sci. 2001, 48, 924-928.
    • (2001) IEEE Trans. Nucl. Sci. , vol.48 , pp. 924-928
    • Beddar, A.S.1    Kinsella, T.J.2    Ikhlef, A.3    Sibata, C.H.4
  • 4
    • 34247629705 scopus 로고    scopus 로고
    • Water-equivalent dosimeter array for small-field external beam radiotherapy
    • Archambault, L.; Beddar, A.S.; Gingras, L.; Lacroix, F.; Roy, R.; Beaulieu, L. Water-equivalent dosimeter array for small-field external beam radiotherapy. Med. Phys. 2007, 34, 1583-1592.
    • (2007) Med. Phys. , vol.34 , pp. 1583-1592
    • Archambault, L.1    Beddar, A.S.2    Gingras, L.3    Lacroix, F.4    Roy, R.5    Beaulieu, L.6
  • 5
    • 0031687825 scopus 로고    scopus 로고
    • Small photon field dosimetry for stereotactic radiosurgery
    • Duggan, D.M.; Coffey, C.W., II. Small photon field dosimetry for stereotactic radiosurgery. Med. Dosim. 1998, 23, 153-159.
    • (1998) Med. Dosim. , vol.23 , pp. 153-159
    • Duggan, D.M.1    Coffey II, C.W.2
  • 6
    • 34248504862 scopus 로고    scopus 로고
    • Plastic scintillation dosimetry and its application to radiotherapy
    • Beddar, A.S. Plastic scintillation dosimetry and its application to radiotherapy. Radiat. Meas. 2007, 41, S124-S133.
    • (2007) Radiat. Meas. , vol.41
    • Beddar, A.S.1
  • 7
    • 33749485629 scopus 로고    scopus 로고
    • A scintillator-optical fiber detector with photodiode readout for dosimetry in small irradiation fields
    • Patras, Greece, 1-4 September
    • Aoyama, T.; Koyama, S.; Maekoshi, H. A scintillator-optical fiber detector with photodiode readout for dosimetry in small irradiation fields. In Proceedings of the VI International Conference on Medical Physics, Patras, Greece, 1-4 September 1999; pp. 117-122.
    • (1999) Proceedings of the VI International Conference on Medical Physics , pp. 117-122
    • Aoyama, T.1    Koyama, S.2    Maekoshi, H.3
  • 8
    • 0021062111 scopus 로고
    • A protocol for the determination of absorbed dose from high-energy photon and electron beams
    • Task Group 21
    • Task Group 21. A protocol for the determination of absorbed dose from high-energy photon and electron beams. Med. Phys. 1983, 10, 741-771.
    • (1983) Med. Phys. , vol.10 , pp. 741-771
  • 9
    • 0033930606 scopus 로고    scopus 로고
    • Water equivalence of plastic organic scintillators in megavoltage radiotherapy bremsstrahlung beams
    • Clift, M.A.; Sutton, R.A.; Webb, D.V. Water equivalence of plastic organic scintillators in megavoltage radiotherapy bremsstrahlung beams. Phys. Med. Biol. 2000, 45, 1885-1895.
    • (2000) Phys. Med. Biol. , vol.45 , pp. 1885-1895
    • Clift, M.A.1    Sutton, R.A.2    Webb, D.V.3
  • 10
    • 31044441058 scopus 로고    scopus 로고
    • Development and characterization of a tissue equivalent plastic scintillator based dosimetry system
    • Petric, M.P.; Robar, J.L.; Clark, B.G. Development and characterization of a tissue equivalent plastic scintillator based dosimetry system. Med. Phys. 2006, 33, 96-105.
    • (2006) Med. Phys. , vol.33 , pp. 96-105
    • Petric, M.P.1    Robar, J.L.2    Clark, B.G.3
  • 12
    • 0035667582 scopus 로고    scopus 로고
    • Verification of IMRT dose distributions using a water beam imaging system
    • Li, J.S.; Boyer, A.L.; Ma, C.-M. Verification of IMRT dose distributions using a water beam imaging system. Med. Phys. 2001, 28, 2466-2474.
    • (2001) Med. Phys. , vol.28 , pp. 2466-2474
    • Li, J.S.1    Boyer, A.L.2    Ma, C.-M.3
  • 13
    • 33749823372 scopus 로고    scopus 로고
    • Water equivalent plastic scintillation detectors in radiation therapy
    • Beddar, A.S. Water equivalent plastic scintillation detectors in radiation therapy. Radiat. Prot. Dosim. 2006, 120, 1-6.
    • (2006) Radiat. Prot. Dosim. , vol.120 , pp. 1-6
    • Beddar, A.S.1
  • 14
    • 0026804696 scopus 로고
    • Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical consideration
    • Beddar, A.S.; Mackie, T.R.; Attix, F.H. Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical consideration. Phys. Med. Biol. 1992, 37, 1883-1900.
    • (1992) Phys. Med. Biol. , vol.37 , pp. 1883-1900
    • Beddar, A.S.1    Mackie, T.R.2    Attix, F.H.3
  • 15
    • 0026793771 scopus 로고
    • Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurements
    • Beddar, A.S.; Mackie, T.R.; Attix, F.H. Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurements. Phys. Med. Biol. 1992, 37, 1901-1913.
    • (1992) Phys. Med. Biol. , vol.37 , pp. 1901-1913
    • Beddar, A.S.1    Mackie, T.R.2    Attix, F.H.3
  • 16
    • 77957705127 scopus 로고    scopus 로고
    • Measuring output factors of small fields formed by collimator jaws and multileaf collimators using plastic scintillation detectors
    • Klein, D.M.; Tailor, R.C.; Archambault, L.; Wang, L.; Therriault-Proulx, F.; Beddar, A.S. Measuring output factors of small fields formed by collimator jaws and multileaf collimators using plastic scintillation detectors. Med. Phys. 2010, 37, 5541-5549.
    • (2010) Med. Phys. , vol.37 , pp. 5541-5549
    • Klein, D.M.1    Tailor, R.C.2    Archambault, L.3    Wang, L.4    Therriault-Proulx, F.5    Beddar, A.S.6
  • 17
    • 80955158534 scopus 로고    scopus 로고
    • Measurements of relative depth doses and Cerenkov light using a scintillating fiber-optic dosimeter with Co-60 radiotherapy source
    • Jang, K.W; Yoo, W.J.; Moon, J.; Han, K.T.; Park, J.-Y.; Lee, B. Measurements of relative depth doses and Cerenkov light using a scintillating fiber-optic dosimeter with Co-60 radiotherapy source. Appl. Radiat. Isot. 2012, 70, 274-277.
    • (2012) Appl. Radiat. Isot. , vol.70 , pp. 274-277
    • Jang, K.W.1    Yoo, W.J.2    Moon, J.3    Han, K.T.4    Park, J.-Y.5    Lee, B.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.