-
1
-
-
84861530866
-
-
NINDS. Hydrocephalus Fact Sheet. Available at: Accessed October 5, 2011
-
NINDS. Hydrocephalus Fact Sheet. 2011. Available at: http://www.ninds. nih.gov/disorders/hydrocephalus/detail-hydrocephalus.htm. Accessed October 5, 2011.
-
(2011)
-
-
-
2
-
-
44649179858
-
Historical trends of neuroendoscopic surgical techniques in the treatment of hydrocephalus
-
Enchev Y, Oi S. Historical trends of neuroendoscopic surgical techniques in the treatment of hydrocephalus. Neurosurg Rev. 2008;31(3):249-262.
-
(2008)
Neurosurg Rev
, vol.31
, Issue.3
, pp. 249-262
-
-
Enchev, Y.1
Oi, S.2
-
3
-
-
84861530865
-
-
The Hydrocephalus Association. The Stats on Hydrocephalus Available at: Accessed October 5, 2011
-
The Hydrocephalus Association. The Stats on Hydrocephalus. 2009. Available at: http://www.hydroassoc.org/about-the-hydrocephalus-association/ hydrocephalusmedia-resources/hydrocephalus-statistics/. Accessed October 5, 2011.
-
(2009)
-
-
-
4
-
-
0036886536
-
Outcome analysis of initial neonatal shunts: Does the valve make a difference?
-
Robinson S, Kaufman B, Park T. Outcome analysis of initial neonatal shunts: does the valve make a difference? Pediatr Neurosurg. 2002;37(6):287-294.
-
(2002)
Pediatr Neurosurg
, vol.37
, Issue.6
, pp. 287-294
-
-
Robinson, S.1
Kaufman, B.2
Park, T.3
-
5
-
-
33744763303
-
Treatment of hydrocephalus: Mere survival is not enough
-
Walker M. Treatment of hydrocephalus: mere survival is not enough. Clin Neurosurg. 2005;52:279-282.
-
(2005)
Clin Neurosurg
, vol.52
, pp. 279-282
-
-
Walker, M.1
-
6
-
-
23144467501
-
Looking at hydrocephalus: Where are we now, where are we going?
-
Walker M. Looking at hydrocephalus: where are we now, where are we going? Childs Nerv Syst. 2005;21(7):524-527.
-
(2005)
Childs Nerv Syst
, vol.21
, Issue.7
, pp. 524-527
-
-
Walker, M.1
-
7
-
-
0035227536
-
John holter's shunt
-
Baru J, Bloom D, Muraszko K, Koop C. John Holter's shunt. J Am Coll Surg. 2001;192(1):79-85.
-
(2001)
J Am Coll Surg
, vol.192
, Issue.1
, pp. 79-85
-
-
Baru, J.1
Bloom, D.2
Muraszko, K.3
Koop, C.4
-
8
-
-
78650917860
-
Evaluation of the shuntcheck noninvasive thermal technique for shunt flow detection in hydrocephalic patients
-
discussion 205
-
Madsen JR, Abazi GS, Fleming L, et al. Evaluation of the ShuntCheck noninvasive thermal technique for shunt flow detection in hydrocephalic patients. Neurosurgery. 2011;68(1):198-205; discussion 205.
-
(2011)
Neurosurgery
, vol.68
, Issue.1
, pp. 198-205
-
-
Madsen, J.R.1
Abazi, G.S.2
Fleming, L.3
-
9
-
-
0031907440
-
Neonatal hydrocephalus. Mechanisms and consequences
-
McAllister JP II, Chovan P. Neonatal hydrocephalus. Mechanisms and consequences. Neurosurg Clin N Am. 1998;9(1):73-93.
-
(1998)
Neurosurg Clin N Am
, vol.9
, Issue.1
, pp. 73-93
-
-
McAllister II, J.P.1
Chovan, P.2
-
10
-
-
0002606717
-
Hydrocephalus-clinical features and management
-
In: Choux M, Di Rocco C, Hockley A, Walker M, eds. Philadelphia, PA: Churchill Livingstone
-
Detwiler P, Porter R, Rekate H. Hydrocephalus-clinical features and management. In: Choux M, Di Rocco C, Hockley A, Walker M, eds. Pediatric Neurosurgery. Philadelphia, PA: Churchill Livingstone; 1999:253-271.
-
(1999)
Pediatric Neurosurgery
, pp. 253-271
-
-
Detwiler, P.1
Porter, R.2
Rekate, H.3
-
11
-
-
4143102308
-
Cellular damage and prevention in childhood hydrocephalus
-
Del Bigio M. Cellular damage and prevention in childhood hydrocephalus. Brain Pathol. 2004;14(3):317-324.
-
(2004)
Brain Pathol
, vol.14
, Issue.3
, pp. 317-324
-
-
Del Bigio, M.1
-
12
-
-
70349194933
-
Infection rates following initial cerebrospinal fluid shunt placement across pediatric hospitals in the united states. Clinical article
-
Simon T, Hall M, Riva-Cambrin J, et al. Infection rates following initial cerebrospinal fluid shunt placement across pediatric hospitals in the United States. Clinical article. J Neurosurg Pediatr. 2009;4(2):156-165.
-
(2009)
J Neurosurg Pediatr
, vol.4
, Issue.2
, pp. 156-165
-
-
Simon, T.1
Hall, M.2
Riva-Cambrin, J.3
-
13
-
-
0031910439
-
Biological reactions to cerebrospinal fluid shunt devices: A review of the cellular pathology
-
Del Bigio M. Biological reactions to cerebrospinal fluid shunt devices: A review of the cellular pathology. Neurosurgery. 1998;42(2):319-325.
-
(1998)
Neurosurgery
, vol.42
, Issue.2
, pp. 319-325
-
-
Del Bigio, M.1
-
14
-
-
0025312667
-
Functions and complications of shunts in different etiologies of childhood hydrocephalus
-
Serlo W, Fernell E, Heikkinen E, Anderson H, von Wendt L. Functions and complications of shunts in different etiologies of childhood hydrocephalus. Childs Nerv Syst. 1990;6(2):92-94.
-
(1990)
Childs Nerv Syst
, vol.6
, Issue.2
, pp. 92-94
-
-
Serlo, W.1
Fernell, E.2
Heikkinen, E.3
Anderson, H.4
Von Wendt, L.5
-
15
-
-
31944447745
-
Failure of cerebrospinal fluid shunts: Part i: Obstruction and mechanical failure
-
Browd S, Ragel B, Gottfried O, Kestle J. Failure of cerebrospinal fluid shunts: part I: obstruction and mechanical failure. Pediatr Neurol. 2006;34(2):83-92.
-
(2006)
Pediatr Neurol
, vol.34
, Issue.2
, pp. 83-92
-
-
Browd, S.1
Ragel, B.2
Gottfried, O.3
Kestle, J.4
-
16
-
-
0026908567
-
Short-term response of brain tissue to cerebrospinal fluid shunts in vivo and in vitro
-
Del Bigio M, Fedoroff S. Short-term response of brain tissue to cerebrospinal fluid shunts in vivo and in vitro. J Biomed Mater Res. 1992;26(8):979-987.
-
(1992)
J Biomed Mater Res
, vol.26
, Issue.8
, pp. 979-987
-
-
Del Bigio, M.1
Fedoroff, S.2
-
18
-
-
77951959261
-
Ventriculoperitoneal shunt complications: A three-year retrospective study in a kenyan national teaching and referral hospital
-
Mwachaka P, Obonyo N, Mutiso B, Ranketi S, Mwang'ombe N. Ventriculoperitoneal shunt complications: A three-year retrospective study in a Kenyan national teaching and referral hospital. Pediatr Neurosurg. 2010;46(1):1-5.
-
(2010)
Pediatr Neurosurg
, vol.46
, Issue.1
, pp. 1-5
-
-
Mwachaka, P.1
Obonyo, N.2
Mutiso, B.3
Ranketi, S.4
Mwang'ombe, N.5
-
19
-
-
70349563152
-
Disruption of the neurogenic niche in the subventricular zone of postnatal hydrocephalic hyh mice
-
Jimenez A, Garcia-Verdugo J, Gonzalez C, et al. Disruption of the neurogenic niche in the subventricular zone of postnatal hydrocephalic hyh mice. J Neuropathol Exp Neurol. 2009;68(9):1006-1020.
-
(2009)
J Neuropathol Exp Neurol
, vol.68
, Issue.9
, pp. 1006-1020
-
-
Jimenez, A.1
Garcia-Verdugo, J.2
Gonzalez, C.3
-
20
-
-
22244463887
-
Ependymal denudation and alterations of the subventricular zone occur in human fetuses with a moderate communicating hydrocephalus
-
Dominguez-Pinos M, Paez P, Jimenez A, et al. Ependymal denudation and alterations of the subventricular zone occur in human fetuses with a moderate communicating hydrocephalus. J Neuropathol Exp Neurol. 2005;64(7):595-604.
-
(2005)
J Neuropathol Exp Neurol
, vol.64
, Issue.7
, pp. 595-604
-
-
Dominguez-Pinos, M.1
Paez, P.2
Jimenez, A.3
-
21
-
-
79251545206
-
Neuroependymal denudation is in progress in full-term human foetal spina bifida aperta
-
Sival D, Guerra M, den Dunnen W, et al. Neuroependymal denudation is in progress in full-term human foetal spina bifida aperta. Brain Pathol. 2011;21(2): 163-179.
-
(2011)
Brain Pathol
, vol.21
, Issue.2
, pp. 163-179
-
-
Sival, D.1
Guerra, M.2
Den Dunnen, W.3
-
22
-
-
58749087548
-
Disruption of neural progenitors along the ventricular and subventricular zones in periventricular heterotopia
-
Ferland R, Batiz L, Neal J, et al. Disruption of neural progenitors along the ventricular and subventricular zones in periventricular heterotopia. Hum Mol Genet. 2009;18(3):497-516.
-
(2009)
Hum Mol Genet
, vol.18
, Issue.3
, pp. 497-516
-
-
Ferland, R.1
Batiz, L.2
Neal, J.3
-
23
-
-
33745179874
-
Heterogeneous expression of hydrocephalic phenotype in the hyh mice carrying a point mutation in alpha-snap
-
Batiz L, Paez P, Jimenez A, et al. Heterogeneous expression of hydrocephalic phenotype in the hyh mice carrying a point mutation in alpha-SNAP. Neurobiol Dis. 2006;23(1):152-168.
-
(2006)
Neurobiol Dis
, vol.23
, Issue.1
, pp. 152-168
-
-
Batiz, L.1
Paez, P.2
Jimenez, A.3
-
24
-
-
0016296691
-
Subcutaneous reaction to silicone in ventriculoperitoneal shunts. Long-term results
-
Sugar O, Bailey O. Subcutaneous reaction to silicone in ventriculoperitoneal shunts. Long-term results. J Neurosurg. 1974;41(3):367-371.
-
(1974)
J Neurosurg
, vol.41
, Issue.3
, pp. 367-371
-
-
Sugar, O.1
Bailey, O.2
-
25
-
-
0022550805
-
Reaction of periventricular tissue in the rat fourth ventricle to chronically placed shunt tubing implants
-
Bruni J, Del Bigio M. Reaction of periventricular tissue in the rat fourth ventricle to chronically placed shunt tubing implants. Neurosurgery. 1986;19(3):337-345.
-
(1986)
Neurosurgery
, vol.19
, Issue.3
, pp. 337-345
-
-
Bruni, J.1
Del Bigio, M.2
-
26
-
-
0019991131
-
Malfunctioning ventriculoperitoneal shunts. Clinical and pathological features
-
Sekhar L, Moossy J, Guthkelch A. Malfunctioning ventriculoperitoneal shunts. Clinical and pathological features. J Neurosurg. 1982;56(3):411-416.
-
(1982)
J Neurosurg
, vol.56
, Issue.3
, pp. 411-416
-
-
Sekhar, L.1
Moossy, J.2
Guthkelch, A.3
-
27
-
-
0026564221
-
Analysis of retained ventricular shunt catheters
-
Koga H, Mukawa J, Nakata M, Sakuta O, Higa Y. Analysis of retained ventricular shunt catheters. Neurol Med Chir (Tokyo). 1992;32(11):824-828.
-
(1992)
Neurol Med Chir (Tokyo)
, vol.32
, Issue.11
, pp. 824-828
-
-
Koga, H.1
Mukawa, J.2
Nakata, M.3
Sakuta, O.4
Higa, Y.5
-
28
-
-
33646170679
-
Neural progenitors populate the cerebrospinal fluid of preterm patients with hydrocephalus
-
Krueger RC Jr., Wu H, Zandian M, et al. Neural progenitors populate the cerebrospinal fluid of preterm patients with hydrocephalus. J Pediatr. 2006;148 (3):337-340.
-
(2006)
J Pediatr
, vol.148
, Issue.3
, pp. 337-340
-
-
Krueger Jr., R.C.1
Wu, H.2
Zandian, M.3
-
29
-
-
0021808211
-
The cytopathology of reactions to ventricular shunts
-
Bigner S, Elmore P, Dee A, Johnston W. The cytopathology of reactions to ventricular shunts. Acta Cytol. 1985;29(3):391-396.
-
(1985)
Acta Cytol
, vol.29
, Issue.3
, pp. 391-396
-
-
Bigner, S.1
Elmore, P.2
Dee, A.3
Johnston, W.4
-
30
-
-
0021749723
-
Sterile shunt malfunction. A scanning electron microscopic perspective
-
Gower D, Lewis J, Kelly DJ. Sterile shunt malfunction. A scanning electron microscopic perspective. J Neurosurg. 1984;61(6):1079-1084.
-
(1984)
J Neurosurg
, vol.61
, Issue.6
, pp. 1079-1084
-
-
Gower, D.1
Lewis, J.2
Kelly, D.J.3
-
31
-
-
0026018005
-
Ventricular cerebrospinal fluid eosinophilia in children with ventriculoperitoneal shunts
-
Tung H, Raffel C, McComb JG. Ventricular cerebrospinal fluid eosinophilia in children with ventriculoperitoneal shunts. J Neurosurg. 1991;75:541-544.
-
(1991)
J Neurosurg
, vol.75
, pp. 541-544
-
-
Tung, H.1
Raffel, C.2
McComb, J.G.3
-
32
-
-
0018962697
-
Supraependymal macrophages of third ventricle of hamster: Morphological, functional and histochemical characterization in situ and in culture
-
Bleier R, Albrecht R. Supraependymal macrophages of third ventricle of hamster: morphological, functional and histochemical characterization in situ and in culture. J Comp Neurol. 1980;192(3):489-504.
-
(1980)
J Comp Neurol
, vol.192
, Issue.3
, pp. 489-504
-
-
Bleier, R.1
Albrecht, R.2
-
33
-
-
0016792661
-
Scanning electron microscopy of the ventricular system in normal and hydrocephalic rabbits. Preliminary report and atlas
-
Page R. Scanning electron microscopy of the ventricular system in normal and hydrocephalic rabbits. Preliminary report and atlas. J Neurosurg. 1975;42(6) 646-664.
-
(1975)
J Neurosurg
, vol.42
, Issue.6
, pp. 646-664
-
-
Page, R.1
-
34
-
-
0017255081
-
Changes of ventricular ependyma and choroid plexus in experimental hydrocephalus, as observed by scanning electron microscopy
-
Go KG, Stokroos I, Blaauw EH, Zuiderveen F, Molenaar I. Changes of ventricular ependyma and choroid plexus in experimental hydrocephalus, as observed by scanning electron microscopy. Acta Neuropathol. 1976;34(1):55-64.
-
(1976)
Acta Neuropathol
, vol.34
, Issue.1
, pp. 55-64
-
-
Go, K.G.1
Stokroos, I.2
Blaauw, E.H.3
Zuiderveen, F.4
Molenaar, I.5
-
35
-
-
0020411935
-
Epiplexus cell (kolmer cell) and its reaction against foreign bodies [in japanese]
-
Nakamura S, Koga N, Moriyasu N. Epiplexus cell (Kolmer cell) and its reaction against foreign bodies [in Japanese]. No To Shinkei. 1982;34(9):895-907.
-
(1982)
No To Shinkei
, vol.34
, Issue.9
, pp. 895-907
-
-
Nakamura, S.1
Koga, N.2
Moriyasu, N.3
-
36
-
-
0026589058
-
Ultrastructure and movement of the ependymal and tracheal cilia in congenitally hydrocephalicwic-hyd rats
-
Shimizu A, Koto M. Ultrastructure and movement of the ependymal and tracheal cilia in congenitally hydrocephalicWIC-Hyd rats. Childs Nerv Syst. 1992;8(1):25-32.
-
(1992)
Childs Nerv Syst
, vol.8
, Issue.1
, pp. 25-32
-
-
Shimizu, A.1
Koto, M.2
-
37
-
-
0033647483
-
Csf shunts 50 years on-past, present, and future
-
Drake JM, Kestle JR, Tuli S. CSF shunts 50 years on-past, present, and future. Childs Nerv Syst. 2000;16(10-11):800-804.
-
(2000)
Childs Nerv Syst
, vol.16
, Issue.10-11
, pp. 800-804
-
-
Drake, J.M.1
Kestle, J.R.2
Tuli, S.3
-
38
-
-
0024582352
-
Hypersensitivity reaction associated with sterile ventriculoperitoneal shunt malfunction
-
Snow R, Kossovsky N. Hypersensitivity reaction associated with sterile ventriculoperitoneal shunt malfunction. Surg Neurol. 1989;31(3):209-214.
-
(1989)
Surg Neurol
, vol.31
, Issue.3
, pp. 209-214
-
-
Snow, R.1
Kossovsky, N.2
-
39
-
-
0003346684
-
Pathophysiology of hydrocephalus
-
In: Choux M, DiRocco R, Hockley AD, Walker ML. Philadelphia, PA: Churchill Livingstone
-
Del Bigio MR, McAllister JP II. Pathophysiology of hydrocephalus. In: Choux M, DiRocco R, Hockley AD, Walker ML. Pediatric Neurosurgery. Vol 4. Philadelphia, PA: Churchill Livingstone; 1999:217-236.
-
(1999)
Pediatric Neurosurgery
, vol.4
, pp. 217-236
-
-
Del Bigio, M.R.1
McAllister II, J.P.2
-
40
-
-
34347393093
-
Reduction of astrogliosis and microgliosis by cerebrospinal fluid shunting in experimental hydrocephalus
-
Miller JM, McAllister JP II. Reduction of astrogliosis and microgliosis by cerebrospinal fluid shunting in experimental hydrocephalus. Cerebrospinal Fluid Res. 2007;4:5.
-
(2007)
Cerebrospinal Fluid Res
, vol.4
, pp. 5
-
-
Miller, J.M.1
McAllister II, J.P.2
-
41
-
-
77957778801
-
Reactive astrocytosis, microgliosis and inflammation in rats with neonatal hydrocephalus
-
Deren K, Packer M, Forsyth J, et al. Reactive astrocytosis, microgliosis and inflammation in rats with neonatal hydrocephalus. Exp Neurol. 2010;226(1): 110-119.
-
(2010)
Exp Neurol
, vol.226
, Issue.1
, pp. 110-119
-
-
Deren, K.1
Packer, M.2
Forsyth, J.3
-
42
-
-
0027975206
-
Transmission electron microscope study of human hydrocephalic cerebral cortex
-
Castejon O. Transmission electron microscope study of human hydrocephalic cerebral cortex. J Submicrosc Cytol Pathol. 1994;26(1):29-39.
-
(1994)
J Submicrosc Cytol Pathol
, vol.26
, Issue.1
, pp. 29-39
-
-
Castejon, O.1
-
43
-
-
0025147282
-
The fine structure of human cerebral perivascular pericytes and juxtavascular phagocytes: Their possible role in hydrocephalic edema resolution
-
Hasan M, Glees P. The fine structure of human cerebral perivascular pericytes and juxtavascular phagocytes: their possible role in hydrocephalic edema resolution. J Hirnforsch. 1990;31(2):237-249.
-
(1990)
J Hirnforsch
, vol.31
, Issue.2
, pp. 237-249
-
-
Hasan, M.1
Glees, P.2
-
44
-
-
0025779941
-
Repair of the blood-brain barrier following implantation of polymer capsules
-
Jaeger C, Winn S, Tresco P, Aebischer P. Repair of the blood-brain barrier following implantation of polymer capsules. Brain Res. 1991;551(1-2):163-170.
-
(1991)
Brain Res
, vol.551
, Issue.1-2
, pp. 163-170
-
-
Jaeger, C.1
Winn, S.2
Tresco, P.3
Aebischer, P.4
-
45
-
-
33746676842
-
Cellular and molecular dynamics in the foreign body reaction
-
Luttikhuizen DT, Harmsen MC, Van Luyn MJ. Cellular and molecular dynamics in the foreign body reaction. Tissue Eng. 2006;12(7):1955-1970.
-
(2006)
Tissue Eng
, vol.12
, Issue.7
, pp. 1955-1970
-
-
Luttikhuizen, D.T.1
Harmsen, M.C.2
Van Luyn, M.J.3
-
46
-
-
38249001129
-
Adhesive proteins and their cellular receptors
-
Mosher D. Adhesive proteins and their cellular receptors. Cardiovasc Pathol. 1993;2(3 suppl):149-155.
-
(1993)
Cardiovasc Pathol
, vol.2
, Issue.3 SUPPL.
, pp. 149-155
-
-
Mosher, D.1
-
47
-
-
0002637733
-
Treatment of hydrocephalus: An historical and critical review of methods and results
-
Scarff J. Treatment of hydrocephalus: An historical and critical review of methods and results. J Neurol Neurosurg Psychiatry. 1963;26:1-26.
-
(1963)
J Neurol Neurosurg Psychiatry
, vol.26
, pp. 1-26
-
-
Scarff, J.1
-
48
-
-
0026770377
-
Integrins: Versatility, modulation, and signaling in cell adhesion
-
Hynes R. Integrins: versatility, modulation, and signaling in cell adhesion. Cell. 1992;69(1):11-25.
-
(1992)
Cell
, vol.69
, Issue.1
, pp. 11-25
-
-
Hynes, R.1
-
49
-
-
0033046220
-
Mechanisms of phagocytosis in macrophages
-
Aderem A, Underhill D. Mechanisms of phagocytosis in macrophages. Annu Rev Immunol. 1999;17:593-623.
-
(1999)
Annu Rev Immunol
, vol.17
, pp. 593-623
-
-
Aderem, A.1
Underhill, D.2
-
50
-
-
0037619257
-
Biocompatibility of implantable synthetic polymeric drug carriers: Focus on brain biocompatibility
-
Fournier E, Passirani C, Montero-Menei CN, Benoit JP. Biocompatibility of implantable synthetic polymeric drug carriers: focus on brain biocompatibility. Biomaterials. 2003;24(19):3311-3331.
-
(2003)
Biomaterials
, vol.24
, Issue.19
, pp. 3311-3331
-
-
Fournier, E.1
Passirani, C.2
Montero-Menei, C.N.3
Benoit, J.P.4
-
51
-
-
0028201717
-
Soft-tissue response to synthetic biomaterials
-
Morehead JM, Holt GR. Soft-tissue response to synthetic biomaterials. Otolaryngol Clin North Am. 1994;27(1):195-201.
-
(1994)
Otolaryngol Clin North Am
, vol.27
, Issue.1
, pp. 195-201
-
-
Morehead, J.M.1
Holt, G.R.2
-
53
-
-
0024000488
-
Inflammatory response to implants
-
Anderson JM. Inflammatory response to implants. ASAIO Trans. 1988;34(2): 101-107.
-
(1988)
ASAIO Trans
, vol.34
, Issue.2
, pp. 101-107
-
-
Anderson, J.M.1
-
54
-
-
23644450358
-
Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays
-
Biran R, Martin DC, Tresco PA. Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arrays. Exp Neurol. 2005;195(1):115-126.
-
(2005)
Exp Neurol
, vol.195
, Issue.1
, pp. 115-126
-
-
Biran, R.1
Martin, D.C.2
Tresco, P.A.3
-
55
-
-
0345869630
-
Chronic response of adult rat brain tissue to implants anchored to the skull
-
Kim YT, Hitchcock RW, Bridge MJ, Tresco PA. Chronic response of adult rat brain tissue to implants anchored to the skull. Biomaterials. 2004;25(12): 2229-2237.
-
(2004)
Biomaterials
, vol.25
, Issue.12
, pp. 2229-2237
-
-
Kim, Y.T.1
Hitchcock, R.W.2
Bridge, M.J.3
Tresco, P.A.4
-
56
-
-
77549087649
-
Mechanical contributions to astrocyte adhesion using a novel in vitro model of catheter obstruction
-
Harris CA, Resau JH, Hudson EA, West RA, Moon C, McAllister JP II. Mechanical contributions to astrocyte adhesion using a novel in vitro model of catheter obstruction. Exp Neurol. 2010;222(2);204-210.
-
(2010)
Exp Neurol
, vol.222
, Issue.2
, pp. 204-210
-
-
Harris, C.A.1
Resau, J.H.2
Hudson, E.A.3
West, R.A.4
Moon, C.5
McAllister II, J.P.6
-
57
-
-
0042345011
-
Computational and experimental study of proximal flow in ventricular catheters. Technical note
-
Lin J, Morris M, Olivero W, Boop F, Sanford RA. Computational and experimental study of proximal flow in ventricular catheters. Technical note. J Neurosurg. 2003;99(2):426-431.
-
(2003)
J Neurosurg
, vol.99
, Issue.2
, pp. 426-431
-
-
Lin, J.1
Morris, M.2
Olivero, W.3
Boop, F.4
Sanford, R.A.5
-
58
-
-
32344441583
-
Shear stress regulation of kruppel-like factor 2 expression is flow pattern-specific
-
Wang N, Miao H, Li Y, et al. Shear stress regulation of Kruppel-like factor 2 expression is flow pattern-specific. Biochem Biophys Res Commun. 2006;341(4): 1244-1251.
-
(2006)
Biochem Biophys Res Commun
, vol.341
, Issue.4
, pp. 1244-1251
-
-
Wang, N.1
Miao, H.2
Li, Y.3
-
59
-
-
46849113236
-
Intracranial pressure waves: Characterization of a pulsation absorber with notch filter properties using systems analysis: Laboratory investigation
-
Zou R, Park E, Kelly E, Egnor M, Wagshul M, Madsen J. Intracranial pressure waves: characterization of a pulsation absorber with notch filter properties using systems analysis: laboratory investigation. J Neurosurg Pediatr. 2008;2(1):83-94.
-
(2008)
J Neurosurg Pediatr
, vol.2
, Issue.1
, pp. 83-94
-
-
Zou, R.1
Park, E.2
Kelly, E.3
Egnor, M.4
Wagshul, M.5
Madsen, J.6
-
60
-
-
80051739486
-
The pulsating brain: A review of experimental and clinical studies of intracranial pulsatility
-
Wagshul M, Eide P, Madsen J. The pulsating brain: A review of experimental and clinical studies of intracranial pulsatility. Fluids Barriers CNS. 2011;8(5):5.
-
(2011)
Fluids Barriers CNS
, vol.8
, Issue.5
, pp. 5
-
-
Wagshul, M.1
Eide, P.2
Madsen, J.3
-
61
-
-
55949117303
-
Changes in intracranial pulse pressure amplitudes after shunt implantation and adjustment of shunt valve opening pressure in normal pressure hydrocephalus
-
Eide P, Sorteberg W. Changes in intracranial pulse pressure amplitudes after shunt implantation and adjustment of shunt valve opening pressure in normal pressure hydrocephalus. Acta Neurochir (Wien). 2008;150(11):1141-1147.
-
(2008)
Acta Neurochir (Wien)
, vol.150
, Issue.11
, pp. 1141-1147
-
-
Eide, P.1
Sorteberg, W.2
-
62
-
-
0034473218
-
Permeability of the blood-brain barrier to albumin and insulin in the young and aged samp8 mouse
-
Banks W, Farr S, Morley J. Permeability of the blood-brain barrier to albumin and Insulin in the young and aged SAMP8 mouse. J Gerontol A Biol Sci Med Sci. 2000;55(12):B601-B606.
-
(2000)
J Gerontol A Biol Sci Med Sci
, vol.55
, Issue.12
-
-
Banks, W.1
Farr, S.2
Morley, J.3
-
63
-
-
84861529140
-
Protein changes in the cerebrospinal fluid of the different types of perinatal human hydrocephalus
-
Castaneyra-Perdomo A, Munoz R, Gonzalez-Marrero I, et al. Protein changes in the cerebrospinal fluid of the different types of perinatal human hydrocephalus. Cerebrospinal Fluid Res. 2006;3(suppl 1):S56.
-
(2006)
Cerebrospinal Fluid Res
, vol.3
, Issue.SUPPL. 1
-
-
Castaneyra-Perdomo, A.1
Munoz, R.2
Gonzalez-Marrero, I.3
-
64
-
-
0001156470
-
Five-year comparative study of hydrocephalus in children with and without operation (113 cases)
-
Foltz EL, Shurtleff DB. Five-year comparative study of hydrocephalus in children with and without operation (113 cases). J Neurosurg. 1963;20:1064-1079.
-
(1963)
J Neurosurg
, vol.20
, pp. 1064-1079
-
-
Foltz, E.L.1
Shurtleff, D.B.2
-
65
-
-
0028862252
-
Physical properties of cerebrospinal fluid of relevance to shunt function 1: The effect of protein upon csf viscosity
-
Brydon H, Hayward R, Harkness W, Bayston R. Physical properties of cerebrospinal fluid of relevance to shunt function. 1: the effect of protein upon CSF viscosity. Br J Neurosurg. 1995;9(5):639-644.
-
(1995)
Br J Neurosurg
, vol.9
, Issue.5
, pp. 639-644
-
-
Brydon, H.1
Hayward, R.2
Harkness, W.3
Bayston, R.4
-
66
-
-
33748444421
-
Macrophage serum-based adhesion to plasma-processed surface chemistry is distinct from that exhibited by fibroblasts
-
Godek M, Malkov G, Fisher E, Grainger D. Macrophage serum-based adhesion to plasma-processed surface chemistry is distinct from that exhibited by fibroblasts. Plasma Process Polym. 2006;3(6-7):485-497.
-
(2006)
Plasma Process Polym
, vol.3
, Issue.6-7
, pp. 485-497
-
-
Godek, M.1
Malkov, G.2
Fisher, E.3
Grainger, D.4
-
67
-
-
77954215301
-
Soluble factor effects on glial cell reactivity at the surface of gel-coated microwires
-
Polikov V, Hong J, Riechert W. Soluble factor effects on glial cell reactivity at the surface of gel-coated microwires. J Neurosci Methods. 2010;190:180-187.
-
(2010)
J Neurosci Methods
, vol.190
, pp. 180-187
-
-
Polikov, V.1
Hong, J.2
Riechert, W.3
-
68
-
-
79955652183
-
Effects of surface wettability, flow and protein concentration on macrohage and astrocyte adhesion in an in vitro model of central nervous system catheter obstruction
-
Harris CA, Resau JH,Hudson EA, et al. Effects of surface wettability, flow and protein concentration on macrohage and astrocyte adhesion in an in vitro model of central nervous system catheter obstruction. J Biomed Mater Res A. 2011;97(4):433-440.
-
(2011)
J Biomed Mater Res A
, vol.97
, Issue.4
, pp. 433-440
-
-
Harris, C.A.1
Resau, J.H.2
Hudson, E.A.3
-
69
-
-
0031923504
-
Protein adsorption to hydrocephalus shunt catheters: Csf protein adsorption
-
Brydon H, Keir G, Thompson E, Bayston R, Hayward R, Harkness W. Protein adsorption to hydrocephalus shunt catheters: CSF protein adsorption. J Neurol Neurosurg Psychiatry. 1998;64(5):643-647.
-
(1998)
J Neurol Neurosurg Psychiatry
, vol.64
, Issue.5
, pp. 643-647
-
-
Brydon, H.1
Keir, G.2
Thompson, E.3
Bayston, R.4
Hayward, R.5
Harkness, W.6
-
70
-
-
0020365757
-
Cerebrospinal fluid proteins and cells in normalpressure hydrocephalus
-
Wikkelso C, Blomstrand C. Cerebrospinal fluid proteins and cells in normalpressure hydrocephalus. J Neurol. 1982;228(3):171-180.
-
(1982)
J Neurol
, vol.228
, Issue.3
, pp. 171-180
-
-
Wikkelso, C.1
Blomstrand, C.2
-
71
-
-
0028452864
-
In vitro study of the intrinsic toxicity of synthetic surfaces to cells
-
Ertel SI, Ratner BD, Kaul A, SchwayMB,Horbett TA. In vitro study of the intrinsic toxicity of synthetic surfaces to cells. J Biomed Mater Res. 1994;28(6):667-675.
-
(1994)
J Biomed Mater Res
, vol.28
, Issue.6
, pp. 667-675
-
-
Ertel, S.I.1
Ratner, B.D.2
Kaul, A.3
Schway, M.B.4
Horbett, T.A.5
-
72
-
-
0019487662
-
Experiences with recurring ventricular catheter obstructions
-
Go KG, Ebels EJ, van Woerden H. Experiences with recurring ventricular catheter obstructions. Clin Neurol Neurosurg. 1981;83(2):47-56.
-
(1981)
Clin Neurol Neurosurg
, vol.83
, Issue.2
, pp. 47-56
-
-
Go, K.G.1
Ebels, E.J.2
Van Woerden, H.3
-
73
-
-
1542358205
-
Immune reactions associated with silicone-based ventriculo-peritoneal shunt malfunctions in children
-
VandeVord PJ, Gupta N, Wilson RB, et al. Immune reactions associated with silicone-based ventriculo-peritoneal shunt malfunctions in children. Biomaterials. 2004;25(17):3853-3860.
-
(2004)
Biomaterials
, vol.25
, Issue.17
, pp. 3853-3860
-
-
VandeVord, P.J.1
Gupta, N.2
Wilson, R.B.3
-
74
-
-
0026794709
-
Antibodies to silicone elastomers and reactions to ventriculoperitoneal shunts
-
Goldblum RM, Pelley RP, O'Donell AA, Pyron D, Heggers JP. Antibodies to silicone elastomers and reactions to ventriculoperitoneal shunts. Lancet. 1992; 340(8818):510-513.
-
(1992)
Lancet
, vol.340
, Issue.8818
, pp. 510-513
-
-
Goldblum, R.M.1
Pelley, R.P.2
O'Donell, A.A.3
Pyron, D.4
Heggers, J.P.5
-
76
-
-
0029112031
-
Evidence for a patent fibrous tract in fractured, outgrown, or disconnected ventriculoperitoneal shunts
-
Clyde B, Albright A. Evidence for a patent fibrous tract in fractured, outgrown, or disconnected ventriculoperitoneal shunts. Pediatr Neurosurg. 1995;23(1):20-25.
-
(1995)
Pediatr Neurosurg
, vol.23
, Issue.1
, pp. 20-25
-
-
Clyde, B.1
Albright, A.2
-
77
-
-
0031969850
-
Silicone elastomer cerebrospinal fluid shunt systems. Council on scientific affairs, american medical association
-
Kalousdian S, Karlan MS, Williams MA. Silicone elastomer cerebrospinal fluid shunt systems. Council on Scientific Affairs, American Medical Association. Neurosurgery. 1998;42(4):887-892.
-
(1998)
Neurosurgery
, vol.42
, Issue.4
, pp. 887-892
-
-
Kalousdian, S.1
Karlan, M.S.2
Williams, M.A.3
-
78
-
-
84995360018
-
What we don't (but should) know about hydrocephalus
-
Bergsneider M, Egnor MR, Johnston M, et al. What we don't (but should) know about hydrocephalus. J Neurosurg. 2006;104(3 suppl):157-159.
-
(2006)
J Neurosurg
, vol.104
, Issue.3 SUPPL.
, pp. 157-159
-
-
Bergsneider, M.1
Egnor, M.R.2
Johnston, M.3
-
79
-
-
43149113938
-
Priorities for hydrocephalus research: Report from a national institutes of health-sponsored workshop
-
Williams MA, McAllister JP, Walker ML, et al. Priorities for hydrocephalus research: report from a National Institutes of Health-sponsored workshop. J Neurosurg. 2007;107(5 suppl):345-357.
-
(2007)
J Neurosurg
, vol.107
, Issue.5 SUPPL.
, pp. 345-357
-
-
Williams, M.A.1
McAllister, J.P.2
Walker, M.L.3
-
80
-
-
0028882705
-
Frequency and causes of shunt revisions in different cerebrospinal fluid shunt types
-
Borgbjerg BM, Gjerris F, Albeck MJ, Hauerberg J, Børgesen SE. Frequency and causes of shunt revisions in different cerebrospinal fluid shunt types. Acta Neurochir (Wien). 1995;136(3-4):189-194.
-
(1995)
Acta Neurochir (Wien)
, vol.136
, Issue.3-4
, pp. 189-194
-
-
Borgbjerg, B.M.1
Gjerris, F.2
Albeck, M.J.3
Hauerberg, J.4
Børgesen, S.E.5
-
81
-
-
0041883816
-
Hydrocephalus therapy: Reduction of shunt occlusions using a peel-away sheath
-
Kehler U, Klohn A, Heese O, Gliemroth J. Hydrocephalus therapy: reduction of shunt occlusions using a peel-away sheath. Clin Neurol Neurosurg. 2003;105(4): 253-255.
-
(2003)
Clin Neurol Neurosurg
, vol.105
, Issue.4
, pp. 253-255
-
-
Kehler, U.1
Klohn, A.2
Heese, O.3
Gliemroth, J.4
-
82
-
-
0032763955
-
Change in ventricular size and effect of ventricular catheter placement in pediatric patients with shunted hydrocephalus
-
Tuli S, O'Hayon B, Drake J, Clarke M, Kestle J. Change in ventricular size and effect of ventricular catheter placement in pediatric patients with shunted hydrocephalus. Neurosurgery. 1999;45(6):1329-1333.
-
(1999)
Neurosurgery
, vol.45
, Issue.6
, pp. 1329-1333
-
-
Tuli, S.1
O'Hayon, B.2
Drake, J.3
Clarke, M.4
Kestle, J.5
-
83
-
-
79960914794
-
Does drainage hole size influence adhesion on ventricular catheterš
-
Harris CA, McAllister JP II. Does drainage hole size influence adhesion on ventricular catheterš Childs Nerv Syst. 2011;27(8):122-132.
-
(2011)
Childs Nerv Syst
, vol.27
, Issue.8
, pp. 122-132
-
-
Harris, C.A.1
McAllister II, J.P.2
-
85
-
-
0021256657
-
The biologic basis for the clinical application of the silicones. A correlate to their biocompatibility
-
Habal MB. The biologic basis for the clinical application of the silicones. A correlate to their biocompatibility. Arch Surg. 1984;119(7):843-848.
-
(1984)
Arch Surg
, vol.119
, Issue.7
, pp. 843-848
-
-
Habal, M.B.1
-
86
-
-
40449091671
-
Treatment of recurrent ventriculoperitoneal shunt failure associated with persistent cerebrospinal fluid eosinophilia and latex allergy by use of an "extracted" shunt
-
Ellis M, Kazina C, Del Bigio MR, McDonald P. Treatment of recurrent ventriculoperitoneal shunt failure associated with persistent cerebrospinal fluid eosinophilia and latex allergy by use of an "extracted" shunt. J Neurosurg Pediatr. 2008;1(3):237-239.
-
(2008)
J Neurosurg Pediatr
, vol.1
, Issue.3
, pp. 237-239
-
-
Ellis, M.1
Kazina, C.2
Del Bigio, M.R.3
McDonald, P.4
-
87
-
-
0345869625
-
Silicone elastomers for reduced protein adsorption
-
Chen H, Brook M, Sheardown H. Silicone elastomers for reduced protein adsorption. Biomaterials. 2004;25(12):2273-2282.
-
(2004)
Biomaterials
, vol.25
, Issue.12
, pp. 2273-2282
-
-
Chen, H.1
Brook, M.2
Sheardown, H.3
-
88
-
-
10444275722
-
Poly(dimethylsiloxane) thin films as biocompatible coatings for microfluidic devices: Cell culture and flow studies with glial cells
-
Peterson SL, McDonald A, Gourley PL, Sasaki DY. Poly(dimethylsiloxane) thin films as biocompatible coatings for microfluidic devices: cell culture and flow studies with glial cells. J Biomed Mater Res A. 2005;72(1):10-18.
-
(2005)
J Biomed Mater Res A
, vol.72
, Issue.1
, pp. 10-18
-
-
Peterson, S.L.1
McDonald, A.2
Gourley, P.L.3
Sasaki, D.Y.4
-
89
-
-
0000964119
-
Biomaterials science: Overview and opportunities with special reference to organic and polymeric glow discharge plasma treatments
-
In: D'Agostino R, Favia P, Fracassi F, eds. Boston, MA: Kluwer Academic Publishers
-
Ratner B. Biomaterials science: overview and opportunities with special reference to organic and polymeric glow discharge plasma treatments. In: D'Agostino R, Favia P, Fracassi F, eds. Plasma Process Polyming of Polymers. Boston, MA: Kluwer Academic Publishers; 1996:453-464.
-
(1996)
Plasma Process Polyming of Polymers
, pp. 453-464
-
-
Ratner, B.1
-
90
-
-
0029549731
-
Cell adhesion to biomaterials: Correlations between surface charge, surface roughness, adsorbed protein, and cell morphology
-
Hallab NJ, Bundy KJ, O'Connor K, Clark R, Moses RL. Cell adhesion to biomaterials: correlations between surface charge, surface roughness, adsorbed protein, and cell morphology. J Long Term Eff Med Implants. 1995;5(3):209-231.
-
(1995)
J Long Term Eff Med Implants
, vol.5
, Issue.3
, pp. 209-231
-
-
Hallab, N.J.1
Bundy, K.J.2
O'Connor, K.3
Clark, R.4
Moses, R.L.5
-
91
-
-
0035116948
-
Evaluation of metallic and polymeric biomaterial surface energy and surface roughness characteristics for directed cell adhesion
-
Hallab NJ, Bundy KJ, O'Connor K, Moses RL, Jacobs JJ. Evaluation of metallic and polymeric biomaterial surface energy and surface roughness characteristics for directed cell adhesion. Tissue Eng. 2001;7(1);55-71.
-
(2001)
Tissue Eng
, vol.7
, Issue.1
, pp. 55-71
-
-
Hallab, N.J.1
Bundy, K.J.2
O'Connor, K.3
Moses, R.L.4
Jacobs, J.J.5
-
92
-
-
0033062402
-
Cell adhesion to textured silicone surfaces: The influence of time of adhesion and texture on focal contact and fibronectin fibril formation
-
van Kooten T, von Recum A. Cell adhesion to textured silicone surfaces: the influence of time of adhesion and texture on focal contact and fibronectin fibril formation. Tissue Eng. 1999;5(3):223-240.
-
(1999)
Tissue Eng
, vol.5
, Issue.3
, pp. 223-240
-
-
Van Kooten, T.1
Von Recum, A.2
-
93
-
-
0029200584
-
The influence of micro-topography on cellular response and the implications for silicone implants
-
von Recum AF, van Kooten TG. The influence of micro-topography on cellular response and the implications for silicone implants. J Biomater Sci Polym Ed. 1995;7(2):181-198.
-
(1995)
J Biomater Sci Polym Ed
, vol.7
, Issue.2
, pp. 181-198
-
-
Von Recum, A.F.1
Van Kooten, T.G.2
-
94
-
-
0032487118
-
Relative importance of surface wettability and charged functional groups on nih 3t3 fibroblast attachment, spreading, and cytoskeletal organization
-
Webb K, Hlady V, Tresco P. Relative importance of surface wettability and charged functional groups on NIH 3T3 fibroblast attachment, spreading, and cytoskeletal organization. J Biomed Mater Res. 1998;41(3):422-430.
-
(1998)
J Biomed Mater Res
, vol.41
, Issue.3
, pp. 422-430
-
-
Webb, K.1
Hlady, V.2
Tresco, P.3
-
95
-
-
0036132508
-
Surface passivation of a microfluidic device to glial cell adhesion: A comparison of hydrophobic and hydrophilic sam coatings
-
Cox JD, Curry MS, Skirboll SK, Gourley PL, Sasaki DY. Surface passivation of a microfluidic device to glial cell adhesion: A comparison of hydrophobic and hydrophilic SAM coatings. Biomaterials. 2002;23(3):929-935.
-
(2002)
Biomaterials
, vol.23
, Issue.3
, pp. 929-935
-
-
Cox, J.D.1
Curry, M.S.2
Skirboll, S.K.3
Gourley, P.L.4
Sasaki, D.Y.5
-
96
-
-
0344372779
-
Hydrogel ventriculoperitoneal shunt for the treatment of hydrocephalus in children
-
In: Matsumoto S, Tamaki N, eds. Tokyo, Japan: Springer-Verlag
-
Wong T, Lee L, Liu R, et al. Hydrogel ventriculoperitoneal shunt for the treatment of hydrocephalus in children. In: Matsumoto S, Tamaki N, eds. Hydrocephalus: Pathogenesis and Treatment. Tokyo, Japan: Springer-Verlag; 1991: 438-449.
-
(1991)
Hydrocephalus: Pathogenesis and Treatment
, pp. 438-449
-
-
Wong, T.1
Lee, L.2
Liu, R.3
-
97
-
-
34547691055
-
Hydrogels as smart biomaterials
-
Kopecek J, Jiyuan Y. Hydrogels as smart biomaterials. Polym Int. 2007;56(9): 1078-1098.
-
(2007)
Polym Int
, vol.56
, Issue.9
, pp. 1078-1098
-
-
Kopecek, J.1
Jiyuan, Y.2
-
98
-
-
0026820021
-
2-Hydroxyethyl methacrylate (HEMA): Chemical properties and applications in Biomedical fields
-
Montheard J, Chatzopoulos M, Chappard D. 2-Hydroxyethyl methacrylate (HEMA): chemical properties and applications in Biomedical fields. J Macromol Sci Polymer Rev. 1992;32(1):1-34.
-
(1992)
J Macromol Sci Polymer Rev
, vol.32
, Issue.1
, pp. 1-34
-
-
Montheard, J.1
Chatzopoulos, M.2
Chappard, D.3
-
99
-
-
77956064817
-
Cell adhesion: Integrating cytoskeletal dynamics and cellular tension
-
Parsons J, Horwitz A, Schwartz M. Cell adhesion: integrating cytoskeletal dynamics and cellular tension. Nat Rev Mol Cell Biol. 2010;11(9):633-643.
-
(2010)
Nat Rev Mol Cell Biol
, vol.11
, Issue.9
, pp. 633-643
-
-
Parsons, J.1
Horwitz, A.2
Schwartz, M.3
-
100
-
-
58149269409
-
Bone marrow-derived human mesenchymal stem cells become quiescent on soft substrates but remain responsive to chemical or mechanical stimuli
-
Winer JP, Janmey PA, McCormick ME, Funaki M. Bone marrow-derived human mesenchymal stem cells become quiescent on soft substrates but remain responsive to chemical or mechanical stimuli. Tissue Eng Part A. 2009;15(1):147-154.
-
(2009)
Tissue Eng Part A
, vol.15
, Issue.1
, pp. 147-154
-
-
Winer, J.P.1
Janmey, P.A.2
McCormick, M.E.3
Funaki, M.4
-
101
-
-
0033525415
-
Effects of photochemically immobilized polymer coatings on protein adsorption, cell adhesion, and the foreign body reaction to silicone rubber
-
DeFife KM, Shive MS, Hagen KM, Clapper DL, Anderson JM. Effects of photochemically immobilized polymer coatings on protein adsorption, cell adhesion, and the foreign body reaction to silicone rubber. J Biomed Mater Res. 1999;44(3):298-307.
-
(1999)
J Biomed Mater Res
, vol.44
, Issue.3
, pp. 298-307
-
-
DeFife, K.M.1
Shive, M.S.2
Hagen, K.M.3
Clapper, D.L.4
Anderson, J.M.5
-
102
-
-
84861529761
-
Inventors implantable medical device with lubricious material
-
200700747322007. April 5
-
Singhal R, Janzig D, Wahlstrand C, et al. inventors; Implantable medical device with lubricious material. US Patent 200700747322007. April 5, 2007.
-
(2007)
US Patent
-
-
Singhal, R.1
Janzig, D.2
Wahlstrand, C.3
-
103
-
-
2942733320
-
Effect of hydrophilic coating on microorganism colonization in silicone tubing
-
discussion 609-610
-
Cagavi F, Akalan N, Celik H, Gur D, Guciz B. Effect of hydrophilic coating on microorganism colonization in silicone tubing. Acta Neurochir (Wien). 2004;146 (6):603-610; discussion 609-610.
-
(2004)
Acta Neurochir (Wien)
, vol.146
, Issue.6
, pp. 603-610
-
-
Cagavi, F.1
Akalan, N.2
Celik, H.3
Gur, D.4
Guciz, B.5
-
104
-
-
0033996559
-
Subcutaneous abscess formation around catheters induced by viable and nonviable staphylococcus epidermidis as well as by small amounts of bacterial cell wall components
-
Boelens JJ, Zaat SA, Meeldijk J, Dankert J. Subcutaneous abscess formation around catheters induced by viable and nonviable Staphylococcus epidermidis as well as by small amounts of bacterial cell wall components. J Biomed Mater Res. 2000;50(4):546-556.
-
(2000)
J Biomed Mater Res
, vol.50
, Issue.4
, pp. 546-556
-
-
Boelens, J.J.1
Zaat, S.A.2
Meeldijk, J.3
Dankert, J.4
-
105
-
-
28444473912
-
Evaluation of polymer and self-assembled monolayer-coated silicone surfaces to reduce neural cell growth
-
Patel K, Tang H, Grever W, et al. Evaluation of polymer and self-assembled monolayer-coated silicone surfaces to reduce neural cell growth. Biomaterials. 2006;27(8):1519-1526.
-
(2006)
Biomaterials
, vol.27
, Issue.8
, pp. 1519-1526
-
-
Patel, K.1
Tang, H.2
Grever, W.3
-
107
-
-
47649114017
-
Biomaterials for the central nervous system
-
Zhong Y, Bellamkonda RV. Biomaterials for the central nervous system. J R Soc Interface. 2008;5(26):957-975.
-
(2008)
J R Soc Interface
, vol.5
, Issue.26
, pp. 957-975
-
-
Zhong, Y.1
Bellamkonda, R.V.2
-
108
-
-
0026332501
-
Protein adsorption to poly (ethylene oxide) surfaces
-
Gombotz WR, Guanghui WH, Horbett TA, Hoffman AS. Protein adsorption to poly (ethylene oxide) surfaces. J Biomed Mater Res A. 1991;25(12):1547-1562.
-
(1991)
J Biomed Mater Res A
, vol.25
, Issue.12
, pp. 1547-1562
-
-
Gombotz, W.R.1
Guanghui, W.H.2
Horbett, T.A.3
Hoffman, A.S.4
-
109
-
-
0027350745
-
Surface modification of polymeric biomaterials with poly (ethylene oxide), albumin, and heparin for reduced thrombogenicity
-
Amiji M, Park K. Surface modification of polymeric biomaterials with poly (ethylene oxide), albumin, and heparin for reduced thrombogenicity. J Biomater Sci Polym Ed. 1993;4(3):217-234.
-
(1993)
J Biomater Sci Polym Ed
, vol.4
, Issue.3
, pp. 217-234
-
-
Amiji, M.1
Park, K.2
-
110
-
-
0020955483
-
Polyethylene oxide as a biomaterial
-
Merrill E, Salzman E. Polyethylene oxide as a biomaterial. ASAIO Trans. 1983;6: 60-64.
-
(1983)
ASAIO Trans
, vol.6
, pp. 60-64
-
-
Merrill, E.1
Salzman, E.2
-
111
-
-
0024993790
-
Surface properties of copolymers of alkyl methacrylates with methoxy (polyethylene oxide) methacrylates and their applications as protein-resistant coatings
-
Lee J, Kopecekova P, Kopecek K, Andrade J. Surface properties of copolymers of alkyl methacrylates with methoxy (polyethylene oxide) methacrylates and their applications as protein-resistant coatings. Biomaterials. 1990;11(7):455-464.
-
(1990)
Biomaterials
, vol.11
, Issue.7
, pp. 455-464
-
-
Lee, J.1
Kopecekova, P.2
Kopecek, K.3
Andrade, J.4
-
112
-
-
0026332501
-
Protein adsorption to poly(ethylene oxide) surfaces
-
Gombotz WR, Guanghui WH, Horbett TA, Hoffman AS. Protein adsorption to poly(ethylene oxide) surfaces. J Biomed Mater Res. 1991;25(12):1547-1562.
-
(1991)
J Biomed Mater Res
, vol.25
, Issue.12
, pp. 1547-1562
-
-
Gombotz, W.R.1
Guanghui, W.H.2
Horbett, T.A.3
Hoffman, A.S.4
-
113
-
-
84861531088
-
Inventors occlusion resistant hydrocephalic shunt
-
September 1
-
Koullick E, Hendriks M, Bertrand W, inventors; Occlusion resistant hydrocephalic shunt. US Patent 7,582,068, September 1, 2009.
-
(2009)
US Patent 7
, vol.582
, pp. 068
-
-
Koullick, E.1
Hendriks, M.2
Bertrand, W.3
-
114
-
-
79960349726
-
Reduction of protein adsorption and macrophage and astrocyte adhesion on ventricular catheters by polyethylene glycol and n-acetyl-l-cysteine
-
Harris C, Resau J, Hudson E, et al. Reduction of protein adsorption and macrophage and astrocyte adhesion on ventricular catheters by polyethylene glycol and N-acetyl-L-cysteine. J Biomed Mater Res A. 2011;98(3):425-433.
-
(2011)
J Biomed Mater Res A
, vol.98
, Issue.3
, pp. 425-433
-
-
Harris, C.1
Resau, J.2
Hudson, E.3
-
115
-
-
0032706817
-
Photochemically immobilized polymer coatings: Effects on protein adsorption, cell adhesion, and leukocyte activation
-
Defife K, Hagen K, Clapper D, Andersen J. Photochemically immobilized polymer coatings: effects on protein adsorption, cell adhesion, and leukocyte activation. J Biomater Sci Polym Ed. 1999;10(10):1063-1074.
-
(1999)
J Biomater Sci Polym Ed
, vol.10
, Issue.10
, pp. 1063-1074
-
-
Defife, K.1
Hagen, K.2
Clapper, D.3
Andersen, J.4
-
116
-
-
24044483932
-
Surface properties of peo-silicone composites: Reducing protein adsorption
-
Chen H, Brook MA, Chen Y, Sheardown H. Surface properties of PEO-silicone composites: reducing protein adsorption. J Biomater Sci Polym Ed. 2005;16(4): 531-548.
-
(2005)
J Biomater Sci Polym Ed
, vol.16
, Issue.4
, pp. 531-548
-
-
Chen, H.1
Brook, M.A.2
Chen, Y.3
Sheardown, H.4
-
117
-
-
73549100206
-
Quantitative analysis of the tissue response to chronically implanted microwire electrodes in rat cortex
-
Winslow BD, Tresco PA. Quantitative analysis of the tissue response to chronically implanted microwire electrodes in rat cortex. Biomaterials. 2010;31 (7):1558-1567.
-
(2010)
Biomaterials
, vol.31
, Issue.7
, pp. 1558-1567
-
-
Winslow, B.D.1
Tresco, P.A.2
-
118
-
-
77958086113
-
Design principles for cytokine-neutralizing gels: Cross-linking effects
-
Sun LT, Bencherif SA, Gilbert TW, Lotze MT, Washburn NR. Design principles for cytokine-neutralizing gels: cross-linking effects. Acta Biomater. 2010;6(12):4708-4715.
-
(2010)
Acta Biomater
, vol.6
, Issue.12
, pp. 4708-4715
-
-
Sun, L.T.1
Bencherif, S.A.2
Gilbert, T.W.3
Lotze, M.T.4
Washburn, N.R.5
-
119
-
-
22544462832
-
Preparation and characterization of polymeric coatings with combined nitric oxide release and immobilized active heparin
-
Zhou Z, Meyerhoff M. Preparation and characterization of polymeric coatings with combined nitric oxide release and immobilized active heparin. Biomaterials. 2005;26(33):6506-6517.
-
(2005)
Biomaterials
, vol.26
, Issue.33
, pp. 6506-6517
-
-
Zhou, Z.1
Meyerhoff, M.2
-
121
-
-
0033971450
-
The living shunt: A tissue engineering approach in the treatment of hydrocephalus
-
Lee IW, Vacanti JP, Taylor GA, Madsen JR. The living shunt: A tissue engineering approach in the treatment of hydrocephalus. Neurol Res. 2000;22(1):105-110.
-
(2000)
Neurol Res
, vol.22
, Issue.1
, pp. 105-110
-
-
Lee, I.W.1
Vacanti, J.P.2
Taylor, G.A.3
Madsen, J.R.4
-
123
-
-
61849098205
-
Functional evaluation of magnetic microactuators for removing biological accumulation: An in vitro study. Conf proc
-
Lee SA, Pinney JR, Khialeeva E, Bergsneider M, Judy JW. Functional evaluation of magnetic microactuators for removing biological accumulation: An in vitro study. Conf Proc IEEE Eng Med Biol Soc. 2008;2008:947-950.
-
(2008)
IEEE Eng Med Biol Soc
, vol.2008
, pp. 947-950
-
-
Lee, S.A.1
Pinney, J.R.2
Khialeeva, E.3
Bergsneider, M.4
Judy, J.W.5
-
124
-
-
34047154125
-
Magnetic microactuators for mems-enabled ventricular catheters for hydrocephalus. Conf proc
-
Lee SA, Vasquez DJ, Bergsneider M, Judy JW. Magnetic microactuators for MEMS-enabled ventricular catheters for hydrocephalus. Conf Proc IEEE Eng Med Biol Soc. 2006;1:2494-2497.
-
(2006)
IEEE Eng Med Biol Soc
, vol.1
, pp. 2494-2497
-
-
Lee, S.A.1
Vasquez, D.J.2
Bergsneider, M.3
Judy, J.W.4
-
126
-
-
84861530863
-
Catheter with block-overriding system
-
inventor. US patent 7226441 June 5
-
Kulessa S, inventor. Catheter with block-overriding system. US patent 7226441. June 5, 2007.
-
(2007)
-
-
Kulessa, S.1
-
127
-
-
77954426655
-
Perforation holes in ventricular catheters-is less more?
-
Thomale UW, Hosch H, Koch A, et al. Perforation holes in ventricular catheters-is less more? Childs Nerv Syst. 2010;26(6):781-789.
-
(2010)
Childs Nerv Syst
, vol.26
, Issue.6
, pp. 781-789
-
-
Thomale, U.W.1
Hosch, H.2
Koch, A.3
-
128
-
-
41949098101
-
Mechanisms for flowenhanced cell adhesion
-
Zhu C, Yago T, Lou J, Zarnitsyna VI, McEver RP. Mechanisms for flowenhanced cell adhesion. Ann Biomed Eng. 2008;36(4):604-621.
-
(2008)
Ann Biomed Eng
, vol.36
, Issue.4
, pp. 604-621
-
-
Zhu, C.1
Yago, T.2
Lou, J.3
Zarnitsyna, V.I.4
McEver, R.P.5
-
129
-
-
33745713600
-
Kinetics of receptor-ligand interactions in immune responses
-
Long M, SLu S, Sun G. Kinetics of receptor-Ligand interactions in immune responses. Cell Mol Immunol. 2006;3(2):79-86.
-
(2006)
Cell Mol Immunol
, vol.3
, Issue.2
, pp. 79-86
-
-
Long, M.1
Slu, S.2
Sun, G.3
-
130
-
-
78649368595
-
Animal experiments to evaluate complications of foreign materials on silicone with shunt catheters: Preliminary results
-
Eymann R, Meier U, Kiefer M. Animal experiments to evaluate complications of foreign materials on silicone with shunt catheters: preliminary results. Acta Neurochir Suppl. 2010;106:91-93.
-
(2010)
Acta Neurochir Suppl
, vol.106
, pp. 91-93
-
-
Eymann, R.1
Meier, U.2
Kiefer, M.3
-
131
-
-
64549127705
-
Cell contact-inhibition signaling as part of woundhealing processes in brain
-
Lanosa XA, Colombo JA. Cell contact-inhibition signaling as part of woundhealing processes in brain. Neuron Glia Biol. 2008;4(1):27-34.
-
(2008)
Neuron Glia Biol
, vol.4
, Issue.1
, pp. 27-34
-
-
Lanosa, X.A.1
Colombo, J.A.2
-
132
-
-
0042279209
-
Polymer design for corneal epithelial tissue adhesion: Pore density
-
Evans MD, Taylor S, Dalton BA, Lohmann D. Polymer design for corneal epithelial tissue adhesion: pore density. J BiomedMater Res A. 2003;64(2):357-364.
-
(2003)
J BiomedMater Res A
, vol.64
, Issue.2
, pp. 357-364
-
-
Evans, M.D.1
Taylor, S.2
Dalton, B.A.3
Lohmann, D.4
-
134
-
-
7344257733
-
Randomized trial of cerebrospinal fluid shunt valve design in pediatric hydrocephalus
-
discussion 303-305
-
Drake JM, Kestle JR, Milner R, et al. Randomized trial of cerebrospinal fluid shunt valve design in pediatric hydrocephalus. Neurosurgery. 1998;43(2): 294-303; discussion 303-305.
-
(1998)
Neurosurgery
, vol.43
, Issue.2
, pp. 294-303
-
-
Drake, J.M.1
Kestle, J.R.2
Milner, R.3
-
135
-
-
33144484210
-
Comparison of side hole versus non side hole high flow hemodialysis catheters
-
Tal MG, Peixoto AJ, Crowley ST, Denbow N, Eliseo D, Pollak J. Comparison of side hole versus non side hole high flow hemodialysis catheters. Hemodial Int. 2006;10(1):63-67.
-
(2006)
Hemodial Int
, vol.10
, Issue.1
, pp. 63-67
-
-
Tal, M.G.1
Peixoto, A.J.2
Crowley, S.T.3
Denbow, N.4
Eliseo, D.5
Pollak, J.6
-
136
-
-
0033755676
-
Ventriculoperitoneal shunt flow dependency on the number of patent holes in a ventricular catheter
-
Ginsberg HJ, Sum A, Drake JM, Cobbold RS. Ventriculoperitoneal shunt flow dependency on the number of patent holes in a ventricular catheter. Pediatr Neurosurg. 2000;33(1):7-11.
-
(2000)
Pediatr Neurosurg
, vol.33
, Issue.1
, pp. 7-11
-
-
Ginsberg, H.J.1
Sum, A.2
Drake, J.M.3
Cobbold, R.S.4
-
137
-
-
0032716408
-
Ventricular anatomy and shunt catheters
-
Kaufman B, Park T. Ventricular anatomy and shunt catheters. Pediatr Neurosurg. 1999;31(1):1-6.
-
(1999)
Pediatr Neurosurg
, vol.31
, Issue.1
, pp. 1-6
-
-
Kaufman, B.1
Park, T.2
-
138
-
-
0016291248
-
Untersuchung des an ventrikelkathetern hydrozephaler patienten haftenden gewebes im lichtund electronenmikroskop
-
Zumstein B, Landolt A. Untersuchung des an Ventrikelkathetern hydrozephaler Patienten haftenden Gewebes im Lichtund Electronenmikroskop. Acta Neurochir (Wien). 1974;30(3-4):287-298.
-
(1974)
Acta Neurochir (Wien)
, vol.30
, Issue.3-4
, pp. 287-298
-
-
Zumstein, B.1
Landolt, A.2
-
139
-
-
0017066074
-
Multiflanged ventricular portnoy catheter for hydrocephalus shunts
-
Haase J, Weeth R. Multiflanged ventricular Portnoy catheter for hydrocephalus shunts. Acta Neurochir (Wien). 1976;33(3-4):231-238.
-
(1976)
Acta Neurochir (Wien)
, vol.33
, Issue.3-4
, pp. 231-238
-
-
Haase, J.1
Weeth, R.2
-
140
-
-
0031757054
-
Adsorption of albumin, collagen, and fibronectin on the surface of poly(hydroxybutyratehydroxyvalerate) (phb/hv) and poly(e-caprolactone) (pcl) films modified by an alkaline hydrolysis and of poly(ethylene terephtalate) (pet) track-etched membranes
-
Rouxhet L, Duhoux F, Borecky O, Legras R, Schneider Y. Adsorption of albumin, collagen, and fibronectin on the surface of poly(hydroxybutyratehydroxyvalerate) (PHB/HV) and poly(e-caprolactone) (PCL) films modified by an alkaline hydrolysis and of poly(ethylene terephtalate) (PET) track-etched membranes. J Biomater Sci Polym Ed. 1998;9(12):1279-1304.
-
(1998)
J Biomater Sci Polym Ed
, vol.9
, Issue.12
, pp. 1279-1304
-
-
Rouxhet, L.1
Duhoux, F.2
Borecky, O.3
Legras, R.4
Schneider, Y.5
-
141
-
-
2942589261
-
Effect of pore morphology on fluid flow through track-etched polycarbonate membrane
-
Tung K, Chang Y, Chuang C. Effect of pore morphology on fluid flow through track-etched Polycarbonate membrane. Tamkang J Sci Eng. 2001;4(2):127-132.
-
(2001)
Tamkang J Sci Eng
, vol.4
, Issue.2
, pp. 127-132
-
-
Tung, K.1
Chang, Y.2
Chuang, C.3
-
143
-
-
84861530381
-
Process for creating an in growth preventing indwelling catheter assembly
-
inventor. US Patent 7763142. July
-
Watson D, inventor. Process for creating an in growth preventing indwelling catheter assembly. US Patent 7763142. July 27, 2010.
-
, vol.27
, pp. 2010
-
-
Watson, D.1
-
145
-
-
84861530382
-
Porous ventricular catheter
-
inventors. US Patent 4767400. August 30
-
Miller S, Pinchuk L, inventors. Porous ventricular catheter. US Patent 4767400. August 30, 1988.
-
(1988)
-
-
Miller, S.1
Pinchuk, L.2
-
146
-
-
84861532627
-
-
inventor Ion beam sputter-etched ventricular catheter for hydrocephalus shunt. US Patent 4377169. March 22
-
Banks B, inventor. Ion beam sputter-etched ventricular catheter for hydrocephalus shunt. US Patent 4377169. March 22, 1983.
-
(1983)
-
-
Banks, B.1
-
148
-
-
0022547806
-
Reaction of rabbit lateral periventricular tissue to shunt tubing implants
-
Del Bigio M, Bruni J. Reaction of rabbit lateral periventricular tissue to shunt tubing implants. J Neurosurg. 1986;64(6):932-940.
-
(1986)
J Neurosurg
, vol.64
, Issue.6
, pp. 932-940
-
-
Del Bigio, M.1
Bruni, J.2
-
149
-
-
0024654279
-
Clinical-pathological analysis of failed central nervous system fluid shunts
-
Kossovsky N, Snow R. Clinical-pathological analysis of failed central nervous system fluid shunts. J Biomed Mater Res. 1989;23(1 suppl):73-86.
-
(1989)
J Biomed Mater Res
, vol.23
, Issue.1 SUPPL.
, pp. 73-86
-
-
Kossovsky, N.1
Snow, R.2
-
150
-
-
0345257554
-
Evaluation of shunt failures by compliance analysis and inspection of shunt valves and shunt materials, using microscopic or scanning electron microscopic techniques
-
In: Matsumoto S, Tamaki N, eds. Tokyo, Japan: Springer Verlag
-
Schoener W. Evaluation of shunt failures by compliance analysis and inspection of shunt valves and shunt materials, using microscopic or scanning electron microscopic techniques. In: Matsumoto S, Tamaki N, eds. Hydrocephalus: Pathogenesis and Treatment. Tokyo, Japan: Springer Verlag; 1991:452-472.
-
(1991)
Hydrocephalus: Pathogenesis and Treatment
, pp. 452-472
-
-
Schoener, W.1
-
151
-
-
78649337365
-
What can be found inside shunt catheters
-
Czernicki Z, Strzalkowski R, Walasek N, Gajkowska B. What can be found inside shunt catheters. Acta Neurochir Suppl. 2009;106(pt 3):81-85.
-
(2009)
Acta Neurochir Suppl
, vol.106
, Issue.PART 3
, pp. 81-85
-
-
Czernicki, Z.1
Strzalkowski, R.2
Walasek, N.3
Gajkowska, B.4
-
152
-
-
0017235076
-
Percutaneous revision of shunt with obstructed ventricular catheter (author's transl)
-
Ono H, Moriyama T, Uneoka K, Matsumura H, Fujita Y. Percutaneous revision of shunt with obstructed ventricular catheter (author's transl). No Shinkei Geka. 1976;4(4):365-370.
-
(1976)
No Shinkei Geka
, vol.4
, Issue.4
, pp. 365-370
-
-
Ono, H.1
Moriyama, T.2
Uneoka, K.3
Matsumura, H.4
Fujita, Y.5
-
153
-
-
0028355675
-
A new ventricular catheter for the prevention and treatment of proximal obstruction in cerebrospinal fluid shunts
-
Ventureyra E, Higgins M. A New ventricular catheter for the prevention and treatment of proximal obstruction in cerebrospinal fluid shunts. Neurosurgery. 1994;34(5):924-926.
-
(1994)
Neurosurgery
, vol.34
, Issue.5
, pp. 924-926
-
-
Ventureyra, E.1
Higgins, M.2
-
154
-
-
33750213583
-
Outcome prediction of third ventriculostomy: A proposed hydrocephalus grading system
-
Kehler U, Regelsberger J, Gliemroth J, Westphal M. Outcome prediction of third ventriculostomy: A proposed hydrocephalus grading system. Minim Invasive Neurosurg. 2006;49(4):238-243.
-
(2006)
Minim Invasive Neurosurg
, vol.49
, Issue.4
, pp. 238-243
-
-
Kehler, U.1
Regelsberger, J.2
Gliemroth, J.3
Westphal, M.4
-
155
-
-
0032801838
-
Percutaneous endoscopic recanalization of the catheter: A new technique of proximal shunt revision
-
discussion 1366-1367
-
Pattisapu JV, Trumble ER, Taylor KR, Howard PD, Kovach TM. Percutaneous endoscopic recanalization of the catheter: A new technique of proximal shunt revision. Neurosurgery. 1999;45(6):1361-1366; discussion 1366-1367.
-
(1999)
Neurosurgery
, vol.45
, Issue.6
, pp. 1361-1366
-
-
Pattisapu, J.V.1
Trumble, E.R.2
Taylor, K.R.3
Howard, P.D.4
Kovach, T.M.5
-
156
-
-
33750082343
-
Recanalization of obstructed cerebrospinal fluid ventricular catheters using ultrasonic cavitation
-
Ginsberg H, Drake J, Peterson T, Cobbold R. Recanalization of obstructed cerebrospinal fluid ventricular catheters using ultrasonic cavitation. Neurosurgery. 2006;5(suppl 2):ONS403-ONS412.
-
(2006)
Neurosurgery
, vol.5
, Issue.SUPPL. 2
-
-
Ginsberg, H.1
Drake, J.2
Peterson, T.3
Cobbold, R.4
-
157
-
-
78951473458
-
Can using a peel-away sheath in shunt implantation prevent ventricular catheter obstruction?
-
Camlar M, Ersahin Y, Ozer FD, Sen F, Orman M. Can using a peel-away sheath in shunt implantation prevent ventricular catheter obstruction? Childs Nerv Syst. 2010;27(2):295-298.
-
(2010)
Childs Nerv Syst
, vol.27
, Issue.2
, pp. 295-298
-
-
Camlar, M.1
Ersahin, Y.2
Ozer, F.D.3
Sen, F.4
Orman, M.5
-
158
-
-
0014174010
-
Ventriculo-peritoneal shunts in the management of hydrocephalus
-
Ames R. Ventriculo-peritoneal shunts in the management of hydrocephalus. J Neurosurg. 1967;27(6):525-529.
-
(1967)
J Neurosurg
, vol.27
, Issue.6
, pp. 525-529
-
-
Ames, R.1
-
159
-
-
0344372796
-
Floating ventricular catheter: A new shunting device
-
Nakamura S, Moriyasu N. Floating ventricular catheter: A new shunting device. Monogr Neural Sci. 1982;8:191-194.
-
(1982)
Monogr Neural Sci
, vol.8
, pp. 191-194
-
-
Nakamura, S.1
Moriyasu, N.2
-
160
-
-
0026454485
-
E-ptfe ventricular shunt catheters
-
Gower DJ, Watson D, Harper D. e-PTFE ventricular shunt catheters. Neurosurgery. 1992;31(6):1132-1135.
-
(1992)
Neurosurgery
, vol.31
, Issue.6
, pp. 1132-1135
-
-
Gower, D.J.1
Watson, D.2
Harper, D.3
-
161
-
-
0019415568
-
Antimicrobial activity of silicone rubber used in hydrocephalus shunts, after impregnation with antimicrobial substances
-
Bayston R, Milner R. Antimicrobial activity of silicone rubber used in hydrocephalus shunts, after impregnation with antimicrobial substances. J Clin Pathol. 1981;34(9):1057-1062.
-
(1981)
J Clin Pathol
, vol.34
, Issue.9
, pp. 1057-1062
-
-
Bayston, R.1
Milner, R.2
-
162
-
-
0024393399
-
Prevention of hydrocephalus shunt catheter colonisation in vitro by impregnatino with antimicrobials
-
Bayston R, Grove N, Siegel J, Lawellin D, Barsham S. Prevention of hydrocephalus shunt catheter colonisation in vitro by impregnatino with antimicrobials. J Neurol Neurosurg Psychiatry. 1989;52(5):605-609.
-
(1989)
J Neurol Neurosurg Psychiatry
, vol.52
, Issue.5
, pp. 605-609
-
-
Bayston, R.1
Grove, N.2
Siegel, J.3
Lawellin, D.4
Barsham, S.5
-
164
-
-
33645276856
-
Effect of cast molded rifampicin/silicone on staphylococcus epidermidis biofilm formation
-
Liang X, Wang A, Cao T, et al. Effect of cast molded rifampicin/silicone on Staphylococcus epidermidis biofilm formation. J Biomed Mater Res A. 2006;76 (3):580-588.
-
(2006)
J Biomed Mater Res A
, vol.76
, Issue.3
, pp. 580-588
-
-
Liang, X.1
Wang, A.2
Cao, T.3
-
165
-
-
65749089602
-
Initial experience with silver-impregnated polyurethane ventricular catheter for shunting of cerebrospinal fluid in patients with infected hydrocephalus
-
Izci Y, Secer H, Akay C, Gonul E. Initial experience with silver-impregnated polyurethane ventricular catheter for shunting of cerebrospinal fluid in patients with infected hydrocephalus. Neurol Res. 2009;31(3):234-237.
-
(2009)
Neurol Res
, vol.31
, Issue.3
, pp. 234-237
-
-
Izci, Y.1
Secer, H.2
Akay, C.3
Gonul, E.4
|