메뉴 건너뛰기




Volumn 14, Issue 2, 2012, Pages 367-373

Parylene-based implantable platinum-black coated wire microelectrode for orbicularis oculi muscle electrical stimulation

Author keywords

Circumferential; Implantable; Microelectrode; Parylene; Platinum black

Indexed keywords

CATHODIC CHARGE; CHLOROPLATINIC ACID; CIRCUMFERENTIAL; COATED WIRES; COSMESIS; CURRENT PULSE; ELECTRICAL STIMULATIONS; ELECTRODE IMPEDANCE; ELECTRODE SITES; ELECTRODE-TISSUE INTERFACE; FACIAL PARALYSIS; IMPLANTABLE; LIFT-OFF PROCESS; MUSCLE STIMULATION; ORBICULARIS; PARYLENES; PLATINUM-BLACK; SACRIFICIAL LAYER; STIMULATION WAVEFORMS; ULTRASONIC BATH;

EID: 84861460923     PISSN: 13872176     EISSN: 15728781     Source Type: Journal    
DOI: 10.1007/s10544-011-9613-8     Document Type: Article
Times cited : (32)

References (16)
  • 2
    • 50249084472 scopus 로고    scopus 로고
    • Neural stimulation and recording electrodes
    • S.F. Cogan, Neural stimulation and recording electrodes. Annu. Rev. Biomed. Eng. 10, 275-309 (2008)
    • (2008) Annu. Rev. Biomed. Eng. , vol.10 , pp. 275-309
    • Cogan, S.F.1
  • 4
    • 0034519580 scopus 로고    scopus 로고
    • Challenges to nerve regeneration
    • DOI 10.1002/1098-2388(200010/11)19:3<312::AID-SSU13>3.0.CO;2-M
    • G.R. Evans, Challenges to nerve regeneration. Semin. Surg. Oncol. 19 (3), 312-318 (2000) (Pubitemid 32052856)
    • (2000) Seminars in Surgical Oncology , vol.19 , Issue.3 , pp. 312-318
    • Evans, G.R.D.1
  • 5
    • 79951575122 scopus 로고    scopus 로고
    • A review of abdominal muscle stimulation for patients with spinal cord injury
    • G. Kathiresan, K. Huntor, P.H. Fraser, S. Jeyaraman, A review of abdominal muscle stimulation for patients with spinal cord injury. J. Phys. Ther. Sci. 22(4), 455-464 (2010)
    • (2010) J. Phys. Ther. Sci. , vol.22 , Issue.4 , pp. 455-464
    • Kathiresan, G.1    Huntor, K.2    Fraser, P.H.3    Jeyaraman, S.4
  • 6
    • 77955369367 scopus 로고    scopus 로고
    • Feasibility of bionic reanimation of a paralyzed aace: A preliminary study of functional electrical stimulation of a paralyzed facial muscle controlled with the electromyography of the contralateral healthy hemiface
    • M. Kurita, A. Takushima, Y. Muraoka, T. Shiraishi, K. Harii, Feasibility of bionic reanimation of a paralyzed aace: a preliminary study of functional electrical stimulation of a paralyzed facial muscle controlled with the electromyography of the contralateral healthy hemiface. Plast. Reconstr. Surg. 126 (2), 81e-3e (2010)
    • (2010) Plast. Reconstr. Surg. , vol.126 , Issue.2
    • Kurita, M.1    Takushima, A.2    Muraoka, Y.3    Shiraishi, T.4    Harii, K.5
  • 9
    • 42549173673 scopus 로고    scopus 로고
    • Activated iridium oxide films fabricated by asymmetric pulses for electrical neural microstimulation and recording
    • Y. Lu, Z. Cai, Y. Cao, H. Yang, Y. Duan, Activated iridium oxide films fabricated by asymmetric pulses for electrical neural microstimulation and recording. Electrochem. Commun. 10, 778-782 (2008)
    • (2008) Electrochem. Commun. , vol.10 , pp. 778-782
    • Lu, Y.1    Cai, Z.2    Cao, Y.3    Yang, H.4    Duan, Y.5
  • 10
    • 0000253585 scopus 로고
    • Preparation of strongly adherent platinum black coatings
    • C.A. Marrese, Preparation of strongly adherent platinum black coatings. Anal. Chem. 59, 217-218 (1987)
    • (1987) Anal. Chem. , vol.59 , pp. 217-218
    • Marrese, C.A.1
  • 11
    • 12344323809 scopus 로고    scopus 로고
    • Electrical stimulation of excitable tissue: Design of efficacious and safe protocols
    • DOI 10.1016/j.jneumeth.2004.10.020, PII S0165027004003826
    • D.R. Merrilla, M. Biksonb, J.G.R. Jefferys, Electrical stimulation of excitable tissue: design of efficacious and safe protocols. J. Neurosci. Meth. 141, 171-198 (2005) (Pubitemid 40136531)
    • (2005) Journal of Neuroscience Methods , vol.141 , Issue.2 , pp. 171-198
    • Merrill, D.R.1    Bikson, M.2    Jefferys, J.G.R.3
  • 13
    • 23844471959 scopus 로고    scopus 로고
    • Functional electrical stimulation for neuromuscular applications
    • DOI 10.1146/annurev.bioeng.6.040803.140103
    • P.H. Peckham, J.S. Knutson, Functional electrical stimulation for neuromuscular applications. Annu. Rev. Biomed. Eng. 7, 327-60 (2005) (Pubitemid 41170191)
    • (2005) Annual Review of Biomedical Engineering , vol.7 , pp. 327-360
    • Peckham, P.H.1    Knutson, J.S.2
  • 16
    • 60449109745 scopus 로고    scopus 로고
    • Integration of au nanorods with flexible thin-film microelectrode arrays for improved neural interfaces
    • H.B. Zhou, G. Li, X.N. Sun, Z.H. Zhu, Q.H. Jin, J.L. Zhao, Q.S. Ren, Integration of Au nanorods with flexible thin-film microelectrode arrays for improved neural interfaces. J. Microelectromech. Syst. 18(1), 88-96 (2009)
    • (2009) J. Microelectromech. Syst. , vol.18 , Issue.1 , pp. 88-96
    • Zhou, H.B.1    Li, G.2    Sun, X.N.3    Zhu, Z.H.4    Jin, Q.H.5    Zhao, J.L.6    Ren, Q.S.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.