-
1
-
-
0032800447
-
Diffusion-weighted single-shot echoplanar MR imaging for liver disease
-
Kim T, Murakami T, Takahashi S, Hori M, Tsuda K, Nakamura H. Diffusion-weighted single-shot echoplanar MR imaging for liver disease. AJR Am J Roentgenol 1999;173:393-398.
-
(1999)
AJR Am J Roentgenol
, vol.173
, pp. 393-398
-
-
Kim, T.1
Murakami, T.2
Takahashi, S.3
Hori, M.4
Tsuda, K.5
Nakamura, H.6
-
2
-
-
0032875761
-
Diffusion-weighted MR imaging with single-shot echo-planar imaging in the upper abdomen: Preliminary clinical experience in 61 patients
-
Ichikawa T, Haradome H, Hachiya J, Nitatori T, Araki T. Diffusion-weighted MR imaging with single-shot echo-planar imaging in the upper abdomen: preliminary clinical experience in 61 patients. Abdom Imaging 1999;24:456-461.
-
(1999)
Abdom Imaging
, vol.24
, pp. 456-461
-
-
Ichikawa, T.1
Haradome, H.2
Hachiya, J.3
Nitatori, T.4
Araki, T.5
-
3
-
-
0031882661
-
Diffusion-weighted MR imaging with single-shot echoplanar sequence: Detection and characterization of focal hepatic lesions
-
Ichikawa T, Haradome H, Hachiya J, Nitatori T, Araki T. Diffusion-weighted MR imaging with single-shot echoplanar sequence: detection and characterization of focal hepatic lesions. AJR Am J Roentgenol 1998;170:397-402.
-
(1998)
AJR Am J Roentgenol
, vol.170
, pp. 397-402
-
-
Ichikawa, T.1
Haradome, H.2
Hachiya, J.3
Nitatori, T.4
Araki, T.5
-
4
-
-
0030766670
-
Focal liver masses: Characterization with diffusion-weighted echo-planar MR imaging
-
Namimoto T, Yamashita Y, Sumi S, Tang Y, Takahashi M. Focal liver masses: characterization with diffusion-weighted echo-planar MR imaging. Radiology 1997;204:739-744.
-
(1997)
Radiology
, vol.204
, pp. 739-744
-
-
Namimoto, T.1
Yamashita, Y.2
Sumi, S.3
Tang, Y.4
Takahashi, M.5
-
5
-
-
0033129838
-
Single-shot diffusion-weighted echo-planar imaging of normal and cirrhotic livers using a phased-array multicoil
-
Stahlberg F, Brockstedt S, Thomsen C, Wirestam R. Single-shot diffusion-weighted echo-planar imaging of normal and cirrhotic livers using a phased-array multicoil. Acta Radiol 1999;40:339.
-
(1999)
Acta Radiol
, vol.40
, pp. 339
-
-
Stahlberg, F.1
Brockstedt, S.2
Thomsen, C.3
Wirestam, R.4
-
6
-
-
0032996364
-
Measurement of the apparent diffusion coefficient in diffuse renal disease by diffusion-weighted echo-planar MR imaging
-
Namimoto T, Yamashita Y, Mitsuzaki K, Nakayama Y, Tang Y, Takahashi M. Measurement of the apparent diffusion coefficient in diffuse renal disease by diffusion-weighted echo-planar MR imaging. J Magn Reson Imaging 1999;9:832-837.
-
(1999)
J Magn Reson Imaging
, vol.9
, pp. 832-837
-
-
Namimoto, T.1
Yamashita, Y.2
Mitsuzaki, K.3
Nakayama, Y.4
Tang, Y.5
Takahashi, M.6
-
7
-
-
0032112086
-
Single-shot diffusion-weighted echo-planar imaging of normal and cirrhotic livers using a phased-array multicoil
-
Amano Y, Kumazaki T., Ishihara M. Single-shot diffusion-weighted echo-planar imaging of normal and cirrhotic livers using a phased-array multicoil. Acta Radiol 1998;39:440-442.
-
(1998)
Acta Radiol
, vol.39
, pp. 440-442
-
-
Amano, Y.1
Kumazaki, T.2
Ishihara, M.3
-
8
-
-
0028118461
-
Abdominal diffusion mapping with use of a wholebody echo-planar system
-
Muller MF, Prasad P, Siewert B, Nissenbaum MA, Raptopoulos V, Edelman RR. Abdominal diffusion mapping with use of a wholebody echo-planar system. Radiology 1994;190:475-478.
-
(1994)
Radiology
, vol.190
, pp. 475-478
-
-
Muller, M.F.1
Prasad, P.2
Siewert, B.3
Nissenbaum, M.A.4
Raptopoulos, V.5
Edelman, R.R.6
-
9
-
-
0029267053
-
Differentiation between hemangiomas and hepatocellular carcinomas with the apparent diffusion coefficient calculated from turboFLASH MR images
-
Moteki T, Ishizaka H, Horikoshi H, Matsumoto M. Differentiation between hemangiomas and hepatocellular carcinomas with the apparent diffusion coefficient calculated from turboFLASH MR images. J Magn Reson Imaging 1995;5:187-191.
-
(1995)
J Magn Reson Imaging
, vol.5
, pp. 187-191
-
-
Moteki, T.1
Ishizaka, H.2
Horikoshi, H.3
Matsumoto, M.4
-
10
-
-
0034959994
-
Diffusion tensor MRI of the human kidney
-
Ries M, Jones RA, Basseau F, Moonen CT, Grenier N. Diffusion tensor MRI of the human kidney. J Magn Reson Imaging 2001;14: 42-49.
-
(2001)
J Magn Reson Imaging
, vol.14
, pp. 42-49
-
-
Ries, M.1
Jones, R.A.2
Basseau, F.3
Moonen, C.T.4
Grenier, N.5
-
11
-
-
0033950873
-
Anisotropic diffusion in kidney: Apparent diffusion coefficient measurements for clinical use
-
Fukuda Y, Ohashi I, Hanafusa K, et al. Anisotropic diffusion in kidney: apparent diffusion coefficient measurements for clinical use. J Magn Reson Imaging 2000;11:156-160.
-
(2000)
J Magn Reson Imaging
, vol.11
, pp. 156-160
-
-
Fukuda, Y.1
Ohashi, I.2
Hanafusa, K.3
-
12
-
-
0029365426
-
Feasibility of MR diffusion studies in the kidney
-
Siegel CL, Aisen AM, Ellis JH, Londy F, Chenevert TL. Feasibility of MR diffusion studies in the kidney. J Magn Reson Imaging 1995; 5:617-620.
-
(1995)
J Magn Reson Imaging
, vol.5
, pp. 617-620
-
-
Siegel, C.L.1
Aisen, A.M.2
Ellis, J.H.3
Londy, F.4
Chenevert, T.L.5
-
13
-
-
0028090623
-
Functional imaging of the kidney by means of measurement of the apparent diffusion coefficient
-
Muller MF, Prasad PV, Bimmler D, Kaiser A, Edelman RR. Functional imaging of the kidney by means of measurement of the apparent diffusion coefficient. Radiology 1994;193:711-715.
-
(1994)
Radiology
, vol.193
, pp. 711-715
-
-
Muller, M.F.1
Prasad, P.V.2
Bimmler, D.3
Kaiser, A.4
Edelman, R.R.5
-
14
-
-
0031898570
-
Ultrafast MR imaging of the abdomen: Echo planar imaging and diffusion-weighted imaging
-
Yamashita Y, Tang Y, Takahashi M. Ultrafast MR imaging of the abdomen: echo planar imaging and diffusion- weighted imaging. J Magn Reson Imaging 1998;8:367-374.
-
(1998)
J Magn Reson Imaging
, vol.8
, pp. 367-374
-
-
Yamashita, Y.1
Tang, Y.2
Takahashi, M.3
-
15
-
-
0035317476
-
Diffusion-weighted echo-planar sequences for the evaluation of the upper abdomen: Technique optimization
-
Ital
-
Laghi A, Catalano C, Assael FG, et al. Diffusion-weighted echo-planar sequences for the evaluation of the upper abdomen: technique optimization. Radiol Med (Torino) 2001;101:213-218. (Ital)
-
(2001)
Radiol Med (Torino)
, vol.101
, pp. 213-218
-
-
Laghi, A.1
Catalano, C.2
Assael, F.G.3
-
16
-
-
0027940779
-
Interleaved echo planar imaging on a standard MRI system
-
Butts K, Riederer SJ, Ehman RL, Thompson RM, Jack CR. Interleaved echo planar imaging on a standard MRI system. Magn Reson Med 1994;31:67-72.
-
(1994)
Magn Reson Med
, vol.31
, pp. 67-72
-
-
Butts, K.1
Riederer, S.J.2
Ehman, R.L.3
Thompson, R.M.4
Jack, C.R.5
-
17
-
-
0028030441
-
Analysis and correction of motion artifacts in diffusion weighted imaging
-
Anderson AW, Gore JC. Analysis and correction of motion artifacts in diffusion weighted imaging. Magn Reson Med 1994;32:379-387.
-
(1994)
Magn Reson Med
, vol.32
, pp. 379-387
-
-
Anderson, A.W.1
Gore, J.C.2
-
18
-
-
0035118869
-
Diffusion-weighted MR imaging of the liver: Distinguishing hepatic abscess from cystic or necrotic tumor
-
Chan JH, Tsul EY, Luk S, et al. Diffusion-weighted MR imaging of the liver: distinguishing hepatic abscess from cystic or necrotic tumor. Abdom Imaging 2001;26:161-165.
-
(2001)
Abdom Imaging
, vol.26
, pp. 161-165
-
-
Chan, J.H.1
Tsul, E.Y.2
Luk, S.3
-
19
-
-
0030033487
-
Encoding of anisotropic diffusion with tetrahedral gradients: A general mathematical diffusion formalism and experimental results
-
Conturo TE, McKinstry RC, Akbudak E, Robinson BH. Encoding of anisotropic diffusion with tetrahedral gradients: a general mathematical diffusion formalism and experimental results. Magn Reson Med 1996;35:399-412.
-
(1996)
Magn Reson Med
, vol.35
, pp. 399-412
-
-
Conturo, T.E.1
McKinstry, R.C.2
Akbudak, E.3
Robinson, B.H.4
-
20
-
-
0031858491
-
Breath-hold T2-weighted MRI of hepatic tumors: Value of echo planar imaging with diffusion-sensitizing gradient
-
Okada Y, Ohtomo K, Kiryu S, Sasaki Y. Breath-hold T2-weighted MRI of hepatic tumors: value of echo planar imaging with diffusion-sensitizing gradient. J Comput Assist Tomogr 1998;22: 364-371.
-
(1998)
J Comput Assist Tomogr
, vol.22
, pp. 364-371
-
-
Okada, Y.1
Ohtomo, K.2
Kiryu, S.3
Sasaki, Y.4
-
21
-
-
0036082536
-
Abdomen: Diffusion-weighted MR imaging with pulse-triggered single-shot sequences
-
Murtz P, Flacke S, Traber F, van den Brink JS, Gieseke J, Schild HH. Abdomen: diffusion-weighted MR imaging with pulse-triggered single-shot sequences. Radiology 2002;224:258-264.
-
(2002)
Radiology
, vol.224
, pp. 258-264
-
-
Murtz, P.1
Flacke, S.2
Traber, F.3
Van den Brink, J.S.4
Gieseke, J.5
Schild, H.H.6
|