메뉴 건너뛰기




Volumn 27, Issue 9, 2012, Pages 3975-3983

Photovoltaic model identification using particle swarm optimization with inverse barrier constraint

Author keywords

Inverse barrier method; maximum power point (MPP); particle swarm optimization (PSO); photovoltaic (PV) model

Indexed keywords

ENVIRONMENTAL CONDITIONS; INVERSE BARRIER; INVERSE-BARRIER METHOD; LIMITED INFORMATION; MAXIMUM POWER POINT; MAXIMUM POWER POINT TRACKING ALGORITHMS; MICRO GRID; MODELING ERRORS; PHOTOVOLTAIC; PHOTOVOLTAIC MODEL; PV MODELS; PV MODULES; SIMULATION STUDIES;

EID: 84861441523     PISSN: 08858993     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPEL.2012.2188818     Document Type: Article
Times cited : (259)

References (33)
  • 2
    • 79958818089 scopus 로고    scopus 로고
    • High-performance adaptive perturb and observe mppt technique for photovoltaic-based microgrids
    • Apr
    • A. K. Abdelsalam, A. M. Massoud, S. Ahmed, and P. N. Enjeti, "High-performance adaptive perturb and observe MPPT technique for photovoltaic-based microgrids," IEEE Trans. Power Electron., vol. 26, no. 4, pp. 1010-1021, Apr. 2011.
    • (2011) IEEE Trans. Power Electron. , vol.26 , Issue.4 , pp. 1010-1021
    • Abdelsalam, A.K.1    Massoud, A.M.2    Ahmed, S.3    Enjeti, P.N.4
  • 3
    • 79958792696 scopus 로고    scopus 로고
    • Fuzzylogic-control approach of a modified hill-climbing method for maximum power point in microgrid standalone photovoltaic system
    • Apr
    • B. N. Alajmi, K. H. Ahmed, S. J. Finney, and B. W. Williams, "Fuzzylogic-control approach of a modified hill-climbing method for maximum power point in microgrid standalone photovoltaic system," IEEE Trans. Power Electron., vol. 26, no. 4, pp. 1022-1030, Apr. 2011.
    • (2011) IEEE Trans. Power Electron. , vol.26 , Issue.4 , pp. 1022-1030
    • Alajmi, B.N.1    Ahmed, K.H.2    Finney, S.J.3    Williams, B.W.4
  • 4
    • 79958814842 scopus 로고    scopus 로고
    • A real maximum power tracking method for mismatching compensation in pv array under partially shaded conditions
    • Apr
    • Y. H. Ji, D. Y. Jung, J. G. Kim, J. H. Kim, T.W. Lee, and C.Y.Won, "A real maximum power tracking method for mismatching compensation in PV array under partially shaded conditions," IEEE Trans. Power Electron., vol. 26, no. 4, pp. 1001-1009, Apr. 2011.
    • (2011) IEEE Trans. Power Electron. , vol.26 , Issue.4 , pp. 1001-1009
    • Ji, Y.H.1    Jung, D.Y.2    Kim, J.G.3    Kim, J.H.4    Lee, T.W.5    Won, C.Y.6
  • 5
    • 79958849323 scopus 로고    scopus 로고
    • A new approach to achieve maximum power point tracking for pv system with a variable inductor
    • Apr
    • L. Zhang, W. G. Hurley, and W. H. Wölfle, "A new approach to achieve maximum power point tracking for PV system with a variable inductor," IEEE Trans. Power Electron., vol. 26, no. 4, pp. 1031-1037, Apr. 2011.
    • (2011) IEEE Trans. Power Electron. , vol.26 , Issue.4 , pp. 1031-1037
    • Zhang, L.1    Hurley, W.G.2    Wölfle, W.H.3
  • 6
    • 79958834649 scopus 로고    scopus 로고
    • New approach for mppt control of photovoltaic system with mutative-scale dual-carrier chaotic search
    • Apr
    • L. Zhou, Y. Chen, and F. Jia, "New approach for MPPT control of photovoltaic system with mutative-scale dual-carrier chaotic search," IEEE Trans. Power Electron., vol. 26, no. 4, pp. 1038-1048, Apr. 2011.
    • (2011) IEEE Trans. Power Electron. , vol.26 , Issue.4 , pp. 1038-1048
    • Zhou, L.1    Chen, Y.2    Jia, F.3
  • 7
    • 83455237426 scopus 로고    scopus 로고
    • Analysis of classical root-finding methods applied to digital maximum power point tracking for sustainable photovoltaic energy generation
    • Dec
    • S. Chun and A. Kwasinski, "Analysis of classical root-finding methods applied to digital maximum power point tracking for sustainable photovoltaic energy generation," IEEE Trans. Power Electron., vol. 26, no. 12, pp. 3730-3743, Dec. 2011.
    • (2011) IEEE Trans. Power Electron. , vol.26 , Issue.12 , pp. 3730-3743
    • Chun, S.1    Kwasinski, A.2
  • 8
    • 83455178334 scopus 로고    scopus 로고
    • Neural-network-based mppt control of a stand-alone hybrid power generation system
    • Dec
    • W. M. Lin, C. M. Hong, and C. H. Chen, "Neural-network-based MPPT control of a stand-alone hybrid power generation system," IEEE Trans. Power Electron., vol. 26, no. 12, pp. 3571-3581, Dec. 2011.
    • (2011) IEEE Trans. Power Electron. , vol.26 , Issue.12 , pp. 3571-3581
    • Lin, W.M.1    Hong, C.M.2    Chen, C.H.3
  • 9
    • 77956571305 scopus 로고    scopus 로고
    • A global maximum power point tracking scheme employing direct search algorithm for photovoltaic systems
    • Oct
    • T. L. Nguyen and K. S. Low, "A global maximum power point tracking scheme employing DIRECT search algorithm for photovoltaic systems," IEEE Trans. Ind. Electron., vol. 57, no. 10, pp. 3456-3467, Oct. 2010.
    • (2010) IEEE Trans. Ind. Electron. , vol.57 , Issue.10 , pp. 3456-3467
    • Nguyen, T.L.1    Low, K.S.2
  • 10
    • 77957730666 scopus 로고    scopus 로고
    • Maximum power point tracking for photovoltaic optimization using ripple-based extremum seeking control
    • Oct
    • S. L. Brunton, C.W. Rowley, S. R. Kulkarni, and C. Clarkson, "Maximum power point tracking for photovoltaic optimization using ripple-based extremum seeking control," IEEE Trans. Power Electron., vol. 24, no. 10, pp. 2531-2540, Oct. 2010.
    • (2010) IEEE Trans. Power Electron. , vol.24 , Issue.10 , pp. 2531-2540
    • Brunton, S.L.1    Rowley, C.W.2    Kulkarni, S.R.3    Clarkson, C.4
  • 11
    • 33847247911 scopus 로고    scopus 로고
    • Model of photovoltaic cell circuits under partial shading
    • A. Kajihara and T. Harakawa, "Model of photovoltaic cell circuits under partial shading," in Proc. IEEE Int. Conf. Ind. Technol., 2005, pp. 866-870.
    • (2005) Proc. IEEE Int. Conf. Ind. Technol. , pp. 866-870
    • Kajihara, A.1    Harakawa, T.2
  • 12
    • 10244260364 scopus 로고    scopus 로고
    • A model of pv generation suitable for stability analysis
    • Dec
    • Y. T. Tan, D. S. Kirschen, and N. Jenkins, "A model of PV generation suitable for stability analysis," IEEE Trans. Energy Convers., vol. 19, no. 4, pp. 748-755, Dec. 2004.
    • (2004) IEEE Trans. Energy Convers. , vol.19 , Issue.4 , pp. 748-755
    • Tan, Y.T.1    Kirschen, D.S.2    Jenkins, N.3
  • 13
    • 35348881452 scopus 로고    scopus 로고
    • A photovoltaic array simulation model for matlab-simulink GUI environment
    • DOI 10.1109/ICCEP.2007.384234, 4272405, 2007 International Conference on Clean Electrical Power, ICCEP '07
    • I. H. Altas and A. M. Sharaf, "A photovoltaic array simulation model for MATLAB-simulink GUI environment," in Proc. Int. Conf. Clean Elect. Power, 2007, pp. 341-345. (Pubitemid 47592337)
    • (2007) 2007 International Conference on Clean Electrical Power, ICCEP '07 , pp. 341-345
    • Altas, I.H.1    Sharaf, A.M.2
  • 16
    • 0035173089 scopus 로고    scopus 로고
    • Evaluatingmppt converter topologies using a matlab pv model
    • G.Walker, "EvaluatingMPPT converter topologies using a MATLAB PV model," J. Elect. Electron. Eng. Aust., vol. 21, no. 1, pp. 45-55, 2001.
    • (2001) J. Elect. Electron. Eng. Aust. , vol.21 , Issue.1 , pp. 45-55
    • Walker, G.1
  • 18
    • 33749242233 scopus 로고    scopus 로고
    • Modelling and experimental verification of the operating current of mono-crystalline photovoltaic modules using four- and five-parameter models
    • DOI 10.1016/j.apenergy.2006.04.007, PII S0306261906000511
    • A. N. Celik and N. Acikgoz, "Modelling and experimental verification of the operating current of mono-crystalline photovoltaic modules using four-and five-parameter models," Appl. Energy, vol. 84, no. 1, pp. 1-15, Jan. 2007. (Pubitemid 44485904)
    • (2007) Applied Energy , vol.84 , Issue.1 , pp. 1-15
    • Celik, A.N.1    Acikgoz, N.2
  • 19
    • 67349141404 scopus 로고    scopus 로고
    • Comprehensive approach to modeling and simulation of photovoltaic arrays
    • May
    • M. G. Villalva, J. R. Gazoli, and E. R Filho, "Comprehensive approach to modeling and simulation of photovoltaic arrays," IEEE Trans. Power Electron., vol. 24, no. 5, pp. 1198-1208, May 2009.
    • (2009) IEEE Trans. Power Electron. , vol.24 , Issue.5 , pp. 1198-1208
    • Villalva, M.G.1    Gazoli, J.R.2    Filho, E.R.3
  • 20
    • 34250790294 scopus 로고    scopus 로고
    • Review and tests of methods for the determination of the solar cell junction ideality factors
    • DOI 10.1016/j.solener.2006.11.002, PII S0038092X06002842
    • M. Bashahu and P. Nkundabakura, "Review and tests of methods for the determination of the solar cell junction ideality factors," Sol. Energy, vol. 81, pp. 856-863, 2007. (Pubitemid 46963351)
    • (2007) Solar Energy , vol.81 , Issue.7 , pp. 856-863
    • Bashahu, M.1    Nkundabakura, P.2
  • 21
    • 84888324298 scopus 로고    scopus 로고
    • Parameter determination of photovoltaic cells from field testing data using particle swarm optimization
    • H. Qin and J.W. Kimball, "Parameter determination of photovoltaic cells from field testing data using particle swarm optimization," in Proc. IEEE Power Energy Conf., 2011, pp. 1-4.
    • (2011) Proc. IEEE Power Energy Conf. , pp. 1-4
    • Qin, H.1    Kimball, J.W.2
  • 22
    • 29144478675 scopus 로고    scopus 로고
    • Improvement and validation of amodel for photovoltaic array performance
    • Jan
    • W. De Soto, S.A.Klein, andW. A. Beckman, "Improvement and validation of amodel for photovoltaic array performance," Sol. Energy, vol. 80, no. 1, pp. 78-88, Jan. 2006.
    • (2006) Sol. Energy , vol.80 , Issue.1 , pp. 78-88
    • De Soto, W.1    Klein, S.A.2    Beckman, W.A.3
  • 23
    • 0032172782 scopus 로고    scopus 로고
    • A method for estimating the long-term performance of direct-coupled PV pumping systems
    • DOI 10.1016/S0038-092X(98)00049-8, PII S0038092X98000498
    • Q. Kou, S. A. Klein, and W. A. Beckman, "A method for estimating the long-term performance of direct-coupled PV pumping systems," Sol. Energy, vol. 64, no. 1-3, pp. 33-40, Sep. 1998. (Pubitemid 29241264)
    • (1998) Solar Energy , vol.64 , Issue.1-3 , pp. 33-40
    • Kou, Q.1    Klein, S.A.2    Beckman, W.A.3
  • 24
    • 77950149068 scopus 로고    scopus 로고
    • A proposed photovoltaic module and arraymathematical modeling destined to simulation
    • R. F. Coelho, F. Concer, and D. C. Martins, "A proposed photovoltaic module and arraymathematical modeling destined to simulation," in Proc. IEEE Int. Symp. Ind. Electron., 2009, pp. 1624-1629.
    • (2009) Proc. IEEE Int. Symp. Ind. Electron. , pp. 1624-1629
    • Coelho, R.F.1    Concer, F.2    Martins, D.C.3
  • 25
    • 0031349447 scopus 로고    scopus 로고
    • Temperature coefficients for pv modules and arrays:measurement methods, difficulties, and results
    • D. L. King, J. A. Kratochvil, and W. E. Boyson, "Temperature coefficients for PV modules and arrays:Measurement methods, difficulties, and results," in Proc. IEEE Photovolt. Spec. Conf., 1997, pp. 1183-1186.
    • (1997) Proc. IEEE Photovolt. Spec. Conf. , pp. 1183-1186
    • King, D.L.1    Kratochvil, J.A.2    Boyson, W.E.3
  • 26
    • 79951634975 scopus 로고    scopus 로고
    • Optimizing the localization of a wireless sensor network in real time based on a low-cost microcontroller
    • Mar
    • H. Guo, K. S. Low, and H. A. Nguyen, "Optimizing the localization of a wireless sensor network in real time based on a low-cost microcontroller, " IEEE Trans. Ind. Electron., vol. 58, no. 3, pp. 741-749, Mar. 2011.
    • (2011) IEEE Trans. Ind. Electron. , vol.58 , Issue.3 , pp. 741-749
    • Guo, H.1    Low, K.S.2    Nguyen, H.A.3
  • 27
    • 80054053477 scopus 로고    scopus 로고
    • Real-time estimation of sensor node's position using particle swarm optimization with log-barrier constraint
    • Nov
    • H. A. Nguyen, H. Guo, and K. S. Low, "Real-time estimation of sensor node's position using particle swarm optimization with log-barrier constraint," IEEE Trans. Instrum. Meas., vol. 60, no. 11, pp. 3619-3628, Nov. 2011.
    • (2011) IEEE Trans. Instrum. Meas. , vol.60 , Issue.11 , pp. 3619-3628
    • Nguyen, H.A.1    Guo, H.2    Low, K.S.3
  • 28
    • 0036489495 scopus 로고    scopus 로고
    • Selecting a suitable model for characterizing photovoltaic devices
    • DOI 10.1016/S0960-1481(01)00056-8, PII S0960148101000568
    • M. A. de Blas, J. L. Torres, E. Prieto, and A. Garćia, "Selecting a suitable model for characterizing photovoltaic devices," Renewable Energy, vol. 25, pp. 371-380, 2002. (Pubitemid 33038170)
    • (2002) Renewable Energy , vol.25 , Issue.3 , pp. 371-380
    • De Blas, M.A.1    Torres, J.L.2    Prieto, E.3    Garcia, A.4
  • 29
    • 0001153665 scopus 로고    scopus 로고
    • Equivalent model of monocrystalline, polycrystalline and amorphous silicon solar cells
    • U. Stutenbaeumer and B. Mesfin, "Equivalent model of monocrystalline, polycrystalline and amorphous silicon solar cells," Renewable Energy, vol. 18, pp. 501-512, 1999.
    • (1999) Renewable Energy , vol.18 , pp. 501-512
    • Stutenbaeumer, U.1    Mesfin, B.2
  • 30
    • 84861442658 scopus 로고    scopus 로고
    • KD210GH-2PU High Efficiency Multicrystalline Photovoltaic Module Datasheet. Kyocera. (2009). [Online]. Available
    • KD210GH-2PU High Efficiency Multicrystalline Photovoltaic Module Datasheet. Kyocera. (2009). [Online]. Available: http://www. kyocerasolar.de/index/products/download/English.-cps-7724-files-8653-File. cpsdownload.tmp/KD210GH2PU-Eng-January%202009.pdf
  • 31
    • 84861437322 scopus 로고    scopus 로고
    • ST40 Photovoltaic Solar Module Datasheet. Shell Solar. [Online].Available
    • ST40 Photovoltaic Solar Module Datasheet. Shell Solar. [Online]. Available: http://telemetryhelp.com/Datasheets/ShellST40-USv1.pdf
  • 32
    • 84861445898 scopus 로고    scopus 로고
    • SP70 Photovoltaic Solar Module Datasheet. Shell Solar. [Online].Available
    • SP70 Photovoltaic Solar Module Datasheet. Shell Solar. [Online]. Available: http://telemetryhelp.com/Datasheets/ShellSP70-USv1.pdf
  • 33
    • 84861435777 scopus 로고    scopus 로고
    • SP85-P/80-P Solar Modules for Off Grids Markets Datasheet. Shell Solar. (2004). [Online]. Available
    • SP85-P/80-P Solar Modules for Off Grids Markets Datasheet. Shell Solar. (2004). [Online]. Available: http://www.effectivesolar.com/PDF/shell/SQ-80-85-P. pdf


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.