메뉴 건너뛰기




Volumn 38, Issue 4, 2012, Pages 385-389

To mix or not to mix in lupus anticoagulant testing? That is the question

Author keywords

anticoagulant testing; coagulation; lupus like anticoagulants; mixing tests

Indexed keywords

LUPUS ANTICOAGULANT;

EID: 84861343727     PISSN: 00946176     EISSN: 10989064     Source Type: Journal    
DOI: 10.1055/s-0032-1304717     Document Type: Article
Times cited : (36)

References (22)
  • 1
    • 0000576581 scopus 로고
    • Circulating anticoagulants: A study of 40 cases and a review of the literature
    • Margolius A Jr, Jackson DP, Ratnoff OD. Circulating anticoagulants: a study of 40 cases and a review of the literature. Medicine (Baltimore): 1961; 40 145 202
    • (1961) Medicine (Baltimore) , vol.40 , pp. 145-202
    • Margolius Jr., A.1    Jackson, D.P.2    Ratnoff, O.D.3
  • 2
    • 0001145459 scopus 로고
    • A hemorrhagic disorder caused by circulating anticoagulant in patients with disseminated lupus erythematosus
    • Conley CL, Hartmann RC. A hemorrhagic disorder caused by circulating anticoagulant in patients with disseminated lupus erythematosus. J Clin Invest: 1952; 31 621 622
    • (1952) J Clin Invest , vol.31 , pp. 621-622
    • Conley, C.L.1    Hartmann, R.C.2
  • 3
  • 4
    • 0029078582 scopus 로고
    • Antiphospholipid antibodies and beta 2-glycoprotein-I in 500 women with recurrent miscarriage: Results of a comprehensive screening approach
    • Rai RS, Regan L, Clifford K., et al. Antiphospholipid antibodies and beta 2-glycoprotein-I in 500 women with recurrent miscarriage: results of a comprehensive screening approach. Hum Reprod: 1995; 10 8 2001 2005
    • (1995) Hum Reprod , vol.10 , Issue.8 , pp. 2001-2005
    • Rai, R.S.1    Regan, L.2    Clifford, K.3
  • 5
    • 0028810205 scopus 로고
    • Criteria for the diagnosis of lupus anticoagulants: An update. on behalf of the Subcommittee on Lupus Anticoagulant/Antiphospholipid Antibody of the Scientific and Standardisation Committee of the ISTH
    • Brandt JT, Triplett DA, Alving B, Scharrer I. Criteria for the diagnosis of lupus anticoagulants: an update. On behalf of the Subcommittee on Lupus Anticoagulant/Antiphospholipid Antibody of the Scientific and Standardisation Committee of the ISTH. Thromb Haemost: 1995; 74 4 1185 1190
    • (1995) Thromb Haemost , vol.74 , Issue.4 , pp. 1185-1190
    • Brandt, J.T.1    Triplett, D.A.2    Alving, B.3    Scharrer, I.4
  • 6
    • 70350004861 scopus 로고    scopus 로고
    • Update of the guidelines for lupus anticoagulant detection
    • Subcommittee on Lupus Anticoagulant/Antiphospholipid Antibody of the Scientific and Standardisation Committee of the International Society on Thrombosis and Haemostasis.
    • Pengo V, Tripodi A, Reber G., et al. Subcommittee on Lupus Anticoagulant/Antiphospholipid Antibody of the Scientific and Standardisation Committee of the International Society on Thrombosis and Haemostasis. Update of the guidelines for lupus anticoagulant detection. J Thromb Haemost: 2009; 7 10 1737 1740
    • (2009) J Thromb Haemost , vol.7 , Issue.10 , pp. 1737-1740
    • Pengo, V.1    Tripodi, A.2    Reber, G.3
  • 7
    • 0023543221 scopus 로고
    • Detection and quantitative evaluation of lupus circulating anticoagulant activity
    • Rosner E, Pauzner R, Lusky A, Modan M, Many A. Detection and quantitative evaluation of lupus circulating anticoagulant activity. Thromb Haemost: 1987; 57 2 144 147 (Pubitemid 18024502)
    • (1987) Thrombosis and Haemostasis , vol.57 , Issue.2 , pp. 144-147
    • Rosner, E.1    Pauzner, R.2    Lusky, A.3    Modan, M.4    Many, A.5
  • 8
    • 0036141307 scopus 로고    scopus 로고
    • A "percent correction" formula for evaluation of mixing studies
    • DOI 10.1309/RREK-8L6M-D2KC-HWLH
    • Chang SH, Tillema V, Scherr DA. A "percent correctiono" formula for evaluation of mixing studies. Am J Clin Pathol: 2002; 117 1 62 73 (Pubitemid 34052474)
    • (2002) American Journal of Clinical Pathology , vol.117 , Issue.1 , pp. 62-73
    • Chang, S.-H.1    Tillema, V.2    Scherr, D.3
  • 9
    • 33845477477 scopus 로고    scopus 로고
    • Interpretation of normal plasma mixing studies in the laboratory diagnosis of lupus anticoagulants
    • DOI 10.1016/j.thromres.2006.03.012, PII S0049384806001289
    • Devreese KM. Interpretation of normal plasma mixing studies in the laboratory diagnosis of lupus anticoagulants. Thromb Res: 2007; 119 3 369 376 (Pubitemid 44918102)
    • (2007) Thrombosis Research , vol.119 , Issue.3 , pp. 369-376
    • Devreese, K.M.J.1
  • 10
    • 33747879160 scopus 로고    scopus 로고
    • The dilution effect of equal volume mixing studies compromises confirmation of inhibition by lupus anticoagulants even when mixture specific reference ranges are applied
    • DOI 10.1016/j.thromres.2005.09.010, PII S0049384805003920
    • Moore GW, Savidge GF. The dilution effect of equal volume mixing studies compromises confirmation of inhibition by lupus anticoagulants even when mixture specific reference ranges are applied. Thromb Res: 2006; 118 4 523 528 (Pubitemid 44292799)
    • (2006) Thrombosis Research , vol.118 , Issue.4 , pp. 523-528
    • Moore, G.W.1    Savidge, G.F.2
  • 11
    • 38649113251 scopus 로고    scopus 로고
    • Further evidence of false negative screening for lupus anticoagulants
    • DOI 10.1016/j.thromres.2007.05.018, PII S0049384807002320
    • Moore GW, Henley A, Greenwood CK, Rangarajan S. Further evidence of false negative screening for lupus anticoagulants. Thromb Res: 2008; 121 4 477 484 (Pubitemid 351174269)
    • (2008) Thrombosis Research , vol.121 , Issue.4 , pp. 477-484
    • Moore, G.W.1    Henley, A.2    Greenwood, C.K.3    Rangarajan, S.4
  • 12
    • 1542440158 scopus 로고    scopus 로고
    • Normal plasma mixing studies in the laboratory diagnosis of lupus anticoagulant
    • Thom J, Ivey L, Eikelboom J. Normal plasma mixing studies in the laboratory diagnosis of lupus anticoagulant. J Thromb Haemost: 2003; 1 12 2689 2691
    • (2003) J Thromb Haemost , vol.1 , Issue.12 , pp. 2689-2691
    • Thom, J.1    Ivey, L.2    Eikelboom, J.3
  • 13
    • 0026065097 scopus 로고
    • Evaluation of different mixing study reagents and dilution effect in lupus anticoagulant testing
    • Kaczor DA, Bickford NN, Triplett DA. Evaluation of different mixing study reagents and dilution effect in lupus anticoagulant testing. Am J Clin Pathol: 1991; 95 3 408 411
    • (1991) Am J Clin Pathol , vol.95 , Issue.3 , pp. 408-411
    • Kaczor, D.A.1    Bickford, N.N.2    Triplett, D.A.3
  • 14
    • 77953773213 scopus 로고    scopus 로고
    • No more mixing tests required for integrated assay systems in the laboratory diagnosis of lupus anticoagulants
    • Devreese KM. No more mixing tests required for integrated assay systems in the laboratory diagnosis of lupus anticoagulants? J Thromb Haemost: 2010; 8 5 1120 1122
    • (2010) J Thromb Haemost , vol.8 , Issue.5 , pp. 1120-1122
    • Devreese, K.M.1
  • 15
    • 78650012663 scopus 로고    scopus 로고
    • Laboratory investigation of lupus anticoagulants: Mixing studies are sometimes required
    • Favaloro EJ, Bonar R, Zebeljan D, Kershaw G, Marsden K. Laboratory investigation of lupus anticoagulants: mixing studies are sometimes required. J Thromb Haemost: 2010; 8 12 2828 2831
    • (2010) J Thromb Haemost , vol.8 , Issue.12 , pp. 2828-2831
    • Favaloro, E.J.1    Bonar, R.2    Zebeljan, D.3    Kershaw, G.4    Marsden, K.5
  • 16
    • 84861342503 scopus 로고    scopus 로고
    • Evaluating laboratory approaches to the identification of lupus anticoagulants: A diagnostic challenge from the RCPA Haematology QAP
    • Bonar R, Favaloro EJ, Zebeljan D., et al. Evaluating laboratory approaches to the identification of lupus anticoagulants: a diagnostic challenge from the RCPA Haematology QAP. Pathology: 2012; 44 3 240 247
    • (2012) Pathology , vol.44 , Issue.3 , pp. 240-247
    • Bonar, R.1    Favaloro, E.J.2    Zebeljan, D.3
  • 17
    • 0026697923 scopus 로고
    • Silica clotting time (SCT) as a screening and confirmatory test for detection of the lupus anticoagulants
    • Chantarangkul V, Tripodi A, Arbini A, Mannucci PM. Silica clotting time (SCT) as a screening and confirmatory test for detection of the lupus anticoagulants. Thromb Res: 1992; 67 4 355 365
    • (1992) Thromb Res , vol.67 , Issue.4 , pp. 355-365
    • Chantarangkul, V.1    Tripodi, A.2    Arbini, A.3    Mannucci, P.M.4
  • 18
    • 0027369135 scopus 로고
    • A hexagonal (II) phase phospholipid neutralization assay for lupus anticoagulant identification
    • Triplett DA, Barna LK, Unger GA. A hexagonal (II) phase phospholipid neutralization assay for lupus anticoagulant identification. Thromb Haemost: 1993; 70 5 787 793 (Pubitemid 23339454)
    • (1993) Thrombosis and Haemostasis , vol.70 , Issue.5 , pp. 787-793
    • Triplett, D.A.1    Barna, L.K.2    Unger, G.A.3
  • 19
    • 0001644081 scopus 로고
    • Prothrombin as cofactor of circulating anticoagulant in systemic lupus crythematosus
    • Loeliger A. Prothrombin as cofactor of circulating anticoagulant in systemic lupus crythematosus. Thromb Diath Haemorrh: 1959; 3 237 256
    • (1959) Thromb Diath Haemorrh , vol.3 , pp. 237-256
    • Loeliger, A.1
  • 21
    • 0003135311 scopus 로고
    • Purification and kinetic studies on a circulating anticoagulant in a suspected case of lupus erythematosus
    • Yin ET, Gaston LW. Purification and kinetic studies on a circulating anticoagulant in a suspected case of lupus erythematosus. Thromb Diath Haemorrh: 1965; 14 1-2 88 115
    • (1965) Thromb Diath Haemorrh , vol.14 , Issue.12 , pp. 88-115
    • Yin, E.T.1    Gaston, L.W.2
  • 22
    • 0026581189 scopus 로고
    • Lupus anticoagulant activity is frequently dependent on the presence of beta 2-glycoprotein i
    • Oosting JD, Derksen RH, Entjes HT, Bouma BN, de Groot PG. Lupus anticoagulant activity is frequently dependent on the presence of beta 2-glycoprotein I. Thromb Haemost: 1992; 67 5 499 502
    • (1992) Thromb Haemost , vol.67 , Issue.5 , pp. 499-502
    • Oosting, J.D.1    Derksen, R.H.2    Entjes, H.T.3    Bouma, B.N.4    De Groot, P.G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.