Volumn 28, Issue 1, 2012, Pages 1-11

Estimation of coronary artery hyperemic blood flow based on arterial lumen volume using angiographic images

Author keywords

Angiography; Blood flow; Blood volume; Regional blood flow; Stenosis

Indexed keywords

ANALYTICAL PARAMETERS; ANGIOCARDIOGRAPHY; ANIMAL EXPERIMENT; ARTERY DIAMETER; ARTICLE; CONE BEAM COMPUTED TOMOGRAPHY; CORONARY ARTERY BLOOD FLOW; CORONARY ARTERY HYPEREMIC BLOOD FLOW; CORONARY ARTERY OBSTRUCTION; CROWN LENGTH; CROWN LUMEN VOLUME; DENSITOMETRY; DISEASE SEVERITY; FRACTIONAL FLOW RESERVE; HEART; IN VIVO STUDY; NONHUMAN; PREDICTION; STEM HYPEREMIC FLOW; SWINE; VALIDATION PROCESS;

EID: 84861234832     PISSN: 15695794     EISSN: 15730743     Source Type: Journal    
DOI: 10.1007/s10554-010-9766-1     Document Type: Article
Times cited : (13)

References (46)
  • 1
    • 0016804110 scopus 로고
    • Observer agreement in evaluating coronary angiograms
    • Detre KM, Wright E, Murphy ML, Takaro T (1975) Observer agreement in evaluating coronary angiograms. Circulation 52:979-986
    • (1975) Circulation , vol.52 , pp. 979-986
    • Detre, K.M.1    Wright, E.2    Murphy, M.L.3    Takaro, T.4
  • 3
    • 0017360308 scopus 로고
    • Variability in the analysis of coronary arteriogram
    • DeRouen TA, Murray JA, Owen W (1977) Variability in the analysis of coronary arteriogram. Circulation 55: 324-328
    • (1977) Circulation , vol.55 , pp. 324-328
    • Derouen, T.A.1    Murray, J.A.2    Owen, W.3
  • 4
  • 5
    • 0015847808 scopus 로고
    • Videodensitometric system for measurement of vessel blood flow, particularly in the coronary arteries in man
    • Smith HC, Sturm RE, Wood EH (1973) Videodensitometric system for measurement of vessel blood flow, particularly in the coronary arteries in man. Am J Cardiol 32:144-150
    • (1973) Am J Cardiol , vol.32 , pp. 144-150
    • Smith, H.C.1    Sturm, R.E.2    Wood, E.H.3
  • 6
    • 0019517415 scopus 로고
    • Angiographic measurement of coronary blood flow by video dilution technique
    • Foerster JM, Lantz BM, Holcroft JW, Link DP, Mason DT (1981) Angiographic measurement of coronary blood flow by videodilution technique. Acta Radiologica Diagn 22:121-127 (Pubitemid 11047437)
    • (1981) Acta Radiologica - Series Diagnosis , vol.22 , Issue.2 , pp. 121-127
    • Foerster, J.M.1    Lantz, B.M.T.2    Holcroft, J.W.3
  • 7
    • 0019784570 scopus 로고
    • Measurement of coronary reactive hyperemia during clinical angiography by video dilution technique
    • Foerster JM, Link DP, Lantz BM, Lee G, Holcroft JW, Mason DT (1981) Measurement of coronary reactive hyperemia during clinical angiography by videodilution technique. Acta Radiologica Diagn 22:209-216 (Pubitemid 12231707)
    • (1981) Acta Radiologica - Series Diagnosis , vol.22 , Issue.3 , pp. 209-216
    • Foerster, J.M.1    Link, D.P.2    Lantz, B.M.T.3
  • 8
    • 0021082468 scopus 로고
    • Use of digitized functional angiography to evaluate arterial blood flow
    • Bursch JH (1983) Use of digitized functional angiography to evaluate arterial blood flow. Cardiovasc Inter Radiol 6:303-310 (Pubitemid 14240111)
    • (1983) CardioVascular and Interventional Radiology , vol.6 , Issue.4-6 , pp. 303-310
    • Bursch, J.H.1
  • 9
    • 0021945861 scopus 로고
    • Validation in dogs of a rapid digital angiographic technique to measure relative coronary blood flow during routine cardiac catheterization
    • DOI 10.1016/0002-9149(85)90326-1
    • Hodgson JM, LeGrand V, Bates ER et al (1985) Validation in dogs of a rapid digital angiographic technique to measure relative coronary blood flow during routine cardiac catheterization. Am J Cardiol 55:188-193 (Pubitemid 15152549)
    • (1985) American Journal of Cardiology , vol.55 , Issue.1 , pp. 188-193
    • Hodgson, B.J.1    LeGrand, V.2    Bates, E.R.3
  • 10
    • 0021933134 scopus 로고
    • The radiographic assessment of coronary blood flow parameters
    • Vogel RA (1985) The radiographic assessment of coronary blood flow parameters. Circulation 72:460-465 (Pubitemid 15242237)
    • (1985) Circulation , vol.72 , Issue.3 , pp. 460-465
    • Vogel, R.A.1
  • 11
    • 0024543909 scopus 로고
    • Digital angiographic impulse response analysis of regional myocardial perfusion: Linearity, reproducibility, accuracy, and comparison with conventional indicator dilution curve parameters in phantom and canine models
    • Eigler NL, Pfaff JM, Zeiher A, Whiting JS, Forrester JS (1989) Digital angiographic impulse response analysis of regional myocardial perfusion: linearity, reproducibility, accuracy and comparison with conventional indicator dilution curve parameters in phantom and canine models. Cir Res 64:853-866 (Pubitemid 19117640)
    • (1989) Circulation Research , vol.64 , Issue.5 , pp. 853-866
    • Eigler, N.L.1    Pfaff, J.M.2    Zeiher, A.3    Whiting, J.S.4    Forrester, J.S.5
  • 14
    • 0025949726 scopus 로고
    • Coronary blood flow measurement using an angiographic first pass distribution technique: A feasibility study
    • Hangiandreou N, Folts J, Peppler W, Mistretta C (1991) Coronary blood flow measurement using an angiographic first pass distribution technique: a feasibility study. Med Phys 18:947-954
    • (1991) Med Phys , vol.18 , pp. 947-954
    • Hangiandreou, N.1    Folts, J.2    Peppler, W.3    Mistretta, C.4
  • 15
    • 0031737872 scopus 로고    scopus 로고
    • Absolute volumetric coronary blood flow measurement with digital subtraction angiography
    • Molloi S, Bednarz G, Tang J, Zhou Y, Mathur T (1998) Absolute volumetric coronary blood flow measurement with digital subtraction angiography. Int J Cardiac Imaging 14:137-145
    • (1998) Int J Cardiac Imaging , vol.14 , pp. 137-145
    • Molloi, S.1    Bednarz, G.2    Tang, J.3    Zhou, Y.4    Mathur, T.5
  • 16
    • 3042833388 scopus 로고    scopus 로고
    • Regional volumetric coronary blood flow measurement by digital angiography: In vivo validation
    • DOI 10.1016/j.acra.2004.04.002, PII S1076633204002454
    • Molloi S, Zhou Y, Kassab GS (2004) Regional volumetric coronary blood flow measurement by digital angiography: in vivo validation. Acad Radiol 11:757-766 (Pubitemid 38881319)
    • (2004) Academic Radiology , vol.11 , Issue.7 , pp. 757-766
    • Molloi, S.1    Zhou, Y.2    Kassab, G.S.3
  • 17
    • 0035818570 scopus 로고    scopus 로고
    • Quantification of coronary artery lumen volume by digital angiography: In vivo validation
    • Molloi S, Kassab GS, Zhou Y (2001) Quantification of coronary artery lumen volume by digital angiography: in vivo validation. Circulation 104:2351-2357 (Pubitemid 33049520)
    • (2001) Circulation , vol.104 , Issue.19 , pp. 2351-2357
    • Molloi, S.1    Kassab, G.S.2    Zhou, Y.3
  • 18
    • 54049113786 scopus 로고    scopus 로고
    • Estimation of regional myocardial mass at risk based on distal arterial lumen volume and length using 3D micro-CT images
    • Le H, Wong JT, Molloi S (2008) Estimation of regional myocardial mass at risk based on distal arterial lumen volume and length using 3D micro-CT images. Comput Med Imaging Graph 32:488-501
    • (2008) Comput Med Imaging Graph , vol.32 , pp. 488-501
    • Le Wong H, J.T.1    Molloi, S.2
  • 19
    • 47649088064 scopus 로고    scopus 로고
    • Allometric scaling in the coronary arterial system
    • Le HQ, Wong JT, Molloi S (2008) Allometric scaling in the coronary arterial system. Int J Cardiovasc Imaging 24:771-781
    • (2008) Int J Cardiovasc Imaging , vol.24 , pp. 771-781
    • Le, H.Q.1    Wong, J.T.2    Molloi, S.3
  • 20
    • 0026654958 scopus 로고
    • Basic structurefunction relations of the coronary vascular tree. The basis of quantitative coronary arteriography for diffuse coronary artery disease
    • Seiler C, Kirkeeide RL, Gould KL (1992) Basic structurefunction relations of the coronary vascular tree. The basis of quantitative coronary arteriography for diffuse coronary artery disease. Circulation 85:1987-2003
    • (1992) Circulation , vol.85 , pp. 1987-2003
    • Seiler, C.1    Kirkeeide, R.L.2    Gould, K.L.3
  • 21
    • 0027474118 scopus 로고
    • Measurement from arteriograms of regional myocardial bed size distal to any point in the coronary vascular tree for assessing anatomic area at risk
    • Seiler C, Kirkeeide RL, Gould KL (1993) Measurement from arteriograms of regional myocardial bed size distal to any point in the coronary vascular tree for assessing anatomic area at risk. J Am College Cardiol 21:783-797 (Pubitemid 23076298)
    • (1993) Journal of the American College of Cardiology , vol.21 , Issue.3 , pp. 783-797
    • Seiler, C.1    Kirkeeide, R.L.2    Gould, K.L.3
  • 22
    • 0037149529 scopus 로고    scopus 로고
    • In vivo validation of the design rules of the coronary arteries and their application in the assessment of diffuse disease
    • PII S0031915502298887
    • Zhou Y, Kassab GS, Molloi S (2002) In vivo validation of the design rules of the coronary arteries and their application in the assessment of diffuse disease. Phys Med Biol 47:977-993 (Pubitemid 34269541)
    • (2002) Physics in Medicine and Biology , vol.47 , Issue.6 , pp. 977-993
    • Zhou, Y.1    Kassab, G.S.2    Molloi, S.3
  • 23
    • 0029945780 scopus 로고    scopus 로고
    • Quantification of volumetric coronary blood flow with dual-energy digital subtraction angiography
    • Molloi S, Ersahin A, Tang J, Hicks J, Leung CY (1996) Quantification of volumetric coronary blood flow with dual-energy digital subtraction angiography. Circulation 93:1919-1927
    • (1996) Circulation , vol.93 , pp. 1919-1927
    • Molloi, S.1    Ersahin, A.2    Tang, J.3    Hicks, J.4    Leung, C.Y.5
  • 24
    • 34247182036 scopus 로고    scopus 로고
    • Regional blood flow analysis and its relationship with arterial branch lengths and lumen volume in the coronary arterial tree
    • DOI 10.1088/0031-9155/52/5/018, PII S0031915507370218, 018
    • Molloi S, Wong JT (2007) Regional blood flow analysis and its relationship with arterial branch lengths and lumen volume in the coronary arterial tree. Phys Med Biol 52:1495-1503 (Pubitemid 46646400)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.5 , pp. 1495-1503
    • Molloi, S.1    Wong, J.T.2
  • 25
    • 0038790738 scopus 로고
    • The physiological principle of minimum work applied to the angle of branching of arteries
    • Murray CD (1926) The physiological principle of minimum work applied to the angle of branching of arteries. J Gen Physiol 9:835-841
    • (1926) J Gen Physiol , vol.9 , pp. 835-841
    • Murray, C.D.1
  • 26
    • 0000205972 scopus 로고
    • The physiological principle of minimum work. I. The vascular system and the cost of blood volume
    • Murray CD (1926) The physiological principle of minimum work. I. The vascular system and the cost of blood volume. Proc Natl Acad Sci USA 12:207-214
    • (1926) Proc Natl Acad Sci USA , vol.12 , pp. 207-214
    • Murray, C.D.1
  • 28
    • 0015444264 scopus 로고
    • Optimal branching structure of the vascular tree
    • Kamiya A, Togawa T (1972) Optimal branching structure of the vascular tree. Bull Math Biophys 34:431-438
    • (1972) Bull Math Biophys , vol.34 , pp. 431-438
    • Kamiya, A.1    Togawa, T.2
  • 29
    • 0017234297 scopus 로고
    • Role of shear forces in arterial branching
    • Zamir M (1976) Role of shear forces in arterial branching. J Gen Physiol 67:213-222
    • (1976) J Gen Physiol , vol.67 , pp. 213-222
    • Zamir, M.1
  • 30
    • 0013508689 scopus 로고
    • Interrelation between cardiac oxygen consumption and coronary blood flow
    • Alella A, Williams FL, Bolene-Williams C, Katz LN (1955) Interrelation between cardiac oxygen consumption and coronary blood flow. Am J Physiol 183:570-582
    • (1955) Am J Physiol , vol.183 , pp. 570-582
    • Alella, A.1    Williams, F.L.2    Bolene-Williams, C.3    Katz, L.N.4
  • 31
    • 45149086968 scopus 로고    scopus 로고
    • Scaling of myocardial mass to flow and morphometry of coronary arteries
    • Choy JS, Kassab GS (2008) Scaling of myocardial mass to flow and morphometry of coronary arteries. J Appl Physiol 104:1281-1286
    • (2008) J Appl Physiol , vol.104 , pp. 1281-1286
    • Choy, J.S.1    Kassab, G.S.2
  • 32
    • 0032777309 scopus 로고    scopus 로고
    • On the design of the coronary arterial tree: A generalization of Murray's law
    • Zhou Y, Kassab GS, Molloi S (1999) On the design of the coronary arterial tree: a generalization of Murray's law. Phys Med Biol 44:2929-2945
    • (1999) Phys Med Biol , vol.44 , pp. 2929-2945
    • Zhou, Y.1    Kassab, G.S.2    Molloi, S.3
  • 33
    • 0000664818 scopus 로고
    • Body size and metabolism
    • Kleiber M (1932) Body size and metabolism. Hilgardia 6:315-353
    • (1932) Hilgardia , vol.6 , pp. 315-353
    • Kleiber, M.1
  • 35
    • 0024595013 scopus 로고
    • Quantification techniques for dual-energy cardiac imaging
    • DOI 10.1118/1.596418
    • Molloi SY, Mistretta CA (1989) Quantification techniques for dual-energy cardiac imaging. Med Phys 16:209-217 (Pubitemid 19112048)
    • (1989) Medical Physics , vol.16 , Issue.2 , pp. 209-217
    • Molloi, S.Y.1    Mistretta, C.A.2
  • 36
    • 0028935335 scopus 로고
    • Relation among stenosis severity, myocardial blood flow, and flow reserve in patients with coronary artery disease
    • Di Carli M, Czernin J, Hoh CK et al (1995) Relation among stenosis severity, myocardial blood flow, and flow reserve in patients with coronary artery disease. Circulation 91:1944-1951
    • (1995) Circulation , vol.91 , pp. 1944-1951
    • Di Carli, M.1    Czernin, J.2    Hoh, C.K.3
  • 38
    • 0033176016 scopus 로고    scopus 로고
    • Towards measurement of coronary blood flow in patients and its alteration by interventions
    • DOI 10.1053/euhj.1999.1676
    • Rutishauser W (1999) The Denolin lecture 1998. Towards measurement of coronary blood flow in patients and its alteration by interventions. Eur Heart J 20:1076-1083 (Pubitemid 29348545)
    • (1999) European Heart Journal , vol.20 , Issue.15 , pp. 1076-1083
    • Rutishauser, W.1
  • 40
    • 0029841529 scopus 로고    scopus 로고
    • Simultaneous coronary pressure and flow velocity measurements in humans: Feasibility, reproducibility, and hemodynamic dependence of coronary flow velocity reserve, hyperemic flow versus pressure slope index, and fractional flow reserve
    • De Bruyne B, Bartunek J, Sys SU, Pijls NH, Heyndrickx GR, Wijns W (1996) Simultaneous coronary pressure and flow velocity measurements in humans. Feasibility, reproducibility, and hemodynamic dependence of coronary flow velocity reserve, hyperemic flow versus pressure slope index, and fractional flow reserve. Circulation 94:1842-1849 (Pubitemid 26349295)
    • (1996) Circulation , vol.94 , Issue.8 , pp. 1842-1849
    • De Bruyne, B.1    Bartunek, J.2    Sys, S.U.3    Pijls, N.H.J.4    Heyndrickx, G.R.5    Wijns, W.6
  • 41
    • 0029041671 scopus 로고
    • Relation between myocardial fractional flow reserve calculated from coronary pressure measurements and exercise- induced myocardial ischemia
    • De Bruyne B, Bartunek J, Sys SU, Heyndrickx GR (1995) Relation between myocardial fractional flow reserve calculated from coronary pressure measurements and exercise- induced myocardial ischemia. Circulation 92:39-46
    • (1995) Circulation , vol.92 , pp. 39-46
    • De Bruyne, B.1    Bartunek, J.2    Sys, S.U.3    Heyndrickx, G.R.4
  • 42
    • 0034696537 scopus 로고    scopus 로고
    • Coronary physiology revisited: Practical insights from the cardiac catheterization laboratory
    • Kern MJ (2000) Coronary physiology revisited: practical insights from the cardiac catheterization laboratory. Circulation 101:1344-1351 (Pubitemid 30158625)
    • (2000) Circulation , vol.101 , Issue.11 , pp. 1344-1351
    • Kern, M.J.1
  • 43
    • 0029375967 scopus 로고
    • A digital filtration technique for scatter-glare correction based on thickness estimation
    • Ersahin A, Molloi S, Yao-Jin Q (1995) A digital filtration technique for scatter-glare correction based on thickness estimation. IEEE Trans Med Imaging 14:587-595
    • (1995) IEEE Trans Med Imaging , vol.14 , pp. 587-595
    • Ersahin, A.1    Molloi, S.2    Yao-Jin, Q.3
  • 44
    • 0032742083 scopus 로고    scopus 로고
    • Scatter and veiling glare estimation based on sampled primary intensity
    • Zhou Y, Mathur T, Molloi S (1999) Scatter and veiling glare estimation based on sampled primary intensity. Med Phys 26:2301-2310
    • (1999) Med Phys , vol.26 , pp. 2301-2310
    • Zhou, Y.1    Mathur, T.2    Molloi, S.3
  • 45
    • 0025628503 scopus 로고
    • Three-dimensional reconstruction of coronary arteries using more than two projections
    • Loew MH (ed). SPIE, Bellingham
    • Wu J, Parker DL (1990) Three-dimensional reconstruction of coronary arteries using more than two projections. In: Loew MH (ed) Medical imaging IV: image processing. SPIE, Bellingham, pp 77-84
    • (1990) Medical Imaging IV: Image Processing , pp. 77-84
    • Wu, J.1    Parker, D.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.