-
1
-
-
0347361501
-
Two-dimensional spatially selective spin inversion and spin-echo refocusing with a single nuclear magnetic resonance pulse
-
Bottomley PA, Hardy CJ,. Two-dimensional spatially selective spin inversion and spin-echo refocusing with a single nuclear magnetic resonance pulse. J Appl Phys 1987; 62: 4284-4290.
-
(1987)
J Appl Phys
, vol.62
, pp. 4284-4290
-
-
Bottomley, P.A.1
Hardy, C.J.2
-
2
-
-
45149145242
-
A k-space analysis of small-tip-angle excitation
-
Pauly J, Nishimura D, Macovski A,. A k-space analysis of small-tip-angle excitation. J Magn Reson 1989; 81: 43-56.
-
(1989)
J Magn Reson
, vol.81
, pp. 43-56
-
-
Pauly, J.1
Nishimura, D.2
MacOvski, A.3
-
3
-
-
1842586446
-
Parallel excitation with an array of transmit coils
-
Zhu Y,. Parallel excitation with an array of transmit coils. Magn Reson Med 2004; 51: 775-784.
-
(2004)
Magn Reson Med
, vol.51
, pp. 775-784
-
-
Zhu, Y.1
-
4
-
-
0037223717
-
Transmit Sense
-
Katscher U, Börnert P, Leussler C, van den Brink JS,. Transmit SENSE. Magn Reson Med 2003; 49: 144-150.
-
(2003)
Magn Reson Med
, vol.49
, pp. 144-150
-
-
Katscher, U.1
Börnert, P.2
Leussler, C.3
Van Den Brink, J.S.4
-
5
-
-
0019137291
-
31P topical magnetic resonance
-
31P topical magnetic resonance. Nature 1980; 287: 736-738.
-
(1980)
Nature
, vol.287
, pp. 736-738
-
-
Gordon, R.E.1
Hanley, P.E.2
Shaw, D.3
Gadian, D.G.4
Radda, G.K.5
Styles, P.6
Bore, P.J.7
Chan, L.8
-
7
-
-
0031817781
-
Reduction of field of view in MRI using a surface-spoiling local gradient insert
-
Wiesler DG, Wen H, Wolff SD, Balaban RS,. Reduction of field of view in MRI using a surface-spoiling local gradient insert. J Magn Reson Imaging 1998; 8: 981-988.
-
(1998)
J Magn Reson Imaging
, vol.8
, pp. 981-988
-
-
Wiesler, D.G.1
Wen, H.2
Wolff, S.D.3
Balaban, R.S.4
-
8
-
-
38249034171
-
Homogeneity spoil spectroscopy as a tool of spectrum localization for in vivo spectroscopy
-
Hennig J, Boesch C, Gruetter R, Martini E,. Homogeneity spoil spectroscopy as a tool of spectrum localization for in vivo spectroscopy. J Magn Reson 1987; 75: 179-183.
-
(1987)
J Magn Reson
, vol.75
, pp. 179-183
-
-
Hennig, J.1
Boesch, C.2
Gruetter, R.3
Martini, E.4
-
9
-
-
0024020698
-
The use of immobilized ferrite to enhance the depth selectivity of in vivo surface coil NMR spectroscopy
-
Geoffrion Y, Rydzy M, Butler KW, Smith IC, Jarrell HC,. The use of immobilized ferrite to enhance the depth selectivity of in vivo surface coil NMR spectroscopy. NMR Biomed 1988; 1: 107-112.
-
(1988)
NMR Biomed
, vol.1
, pp. 107-112
-
-
Geoffrion, Y.1
Rydzy, M.2
Butler, K.W.3
Smith, I.C.4
Jarrell, H.C.5
-
10
-
-
0024644404
-
Surface coil single-pulse localization in vivo via inhomogeneous surface spoiling magnetic gradient
-
Chen W, Ackerman JJ,. Surface coil single-pulse localization in vivo via inhomogeneous surface spoiling magnetic gradient. NMR Biomed 1989; 1: 205-207.
-
(1989)
NMR Biomed
, vol.1
, pp. 205-207
-
-
Chen, W.1
Ackerman, J.J.2
-
11
-
-
0000073840
-
NMR Fresnel transform imaging technique using a quadratic nonlinear field gradient
-
Yamada Y, Tanaka K, Abe Z,. NMR Fresnel transform imaging technique using a quadratic nonlinear field gradient. Rev Sci Instrum 1992; 63: 5348-5358.
-
(1992)
Rev Sci Instrum
, vol.63
, pp. 5348-5358
-
-
Yamada, Y.1
Tanaka, K.2
Abe, Z.3
-
12
-
-
0022598272
-
Use of frequency-modulated radiofrequency pulses in MR imaging experiments
-
Kunz D,. Use of frequency-modulated radiofrequency pulses in MR imaging experiments. Magn Reson Med 1986; 3: 377-384.
-
(1986)
Magn Reson Med
, vol.3
, pp. 377-384
-
-
Kunz, D.1
-
13
-
-
0024433041
-
Localized volume selection technique using an additional radial gradient coil
-
Lee SY, Cho ZH,. Localized volume selection technique using an additional radial gradient coil. Magn Reson Med 1989; 12: 56-63.
-
(1989)
Magn Reson Med
, vol.12
, pp. 56-63
-
-
Lee, S.Y.1
Cho, Z.H.2
-
14
-
-
0025972941
-
New spatial localization method using pulsed high-order field gradients (SHOT: Selection with High-Order gradienT)
-
Oh CH, Hilal SK, Cho ZH, Mun IK,. New spatial localization method using pulsed high-order field gradients (SHOT: Selection with High-Order gradienT). Magn Reson Med 1991; 18: 63-70.
-
(1991)
Magn Reson Med
, vol.18
, pp. 63-70
-
-
Oh, C.H.1
Hilal, S.K.2
Cho, Z.H.3
Mun, I.K.4
-
15
-
-
0028850689
-
Spatial encoding and reconstruction in MRI with quadratic phase profiles
-
Pipe JG,. Spatial encoding and reconstruction in MRI with quadratic phase profiles. Magn Reson Med 1995; 33: 24-33.
-
(1995)
Magn Reson Med
, vol.33
, pp. 24-33
-
-
Pipe, J.G.1
-
16
-
-
38249028655
-
Dynamic range improvement in NMR imaging using phase scrambling
-
Maudsley AA,. Dynamic range improvement in NMR imaging using phase scrambling. J Magn Reson 1988; 76: 287-305.
-
(1988)
J Magn Reson
, vol.76
, pp. 287-305
-
-
Maudsley, A.A.1
-
17
-
-
0023913045
-
Dynamic range compression in MRI by means of a nonlinear gradient pulse
-
Wedeen VJ, Chao YS, Ackerman JL,. Dynamic range compression in MRI by means of a nonlinear gradient pulse. Magn Reson Med 1988; 6: 287-295.
-
(1988)
Magn Reson Med
, vol.6
, pp. 287-295
-
-
Wedeen, V.J.1
Chao, Y.S.2
Ackerman, J.L.3
-
18
-
-
0029884564
-
Analysis of localized quadratic encoding and reconstruction
-
Pipe JG,. Analysis of localized quadratic encoding and reconstruction. Magn Reson Med 1996; 36: 137-146.
-
(1996)
Magn Reson Med
, vol.36
, pp. 137-146
-
-
Pipe, J.G.1
-
19
-
-
23844462841
-
A continuous phase-modulated approach to spatial encoding in ultrafast 2D NMR spectroscopy
-
Tal A, Shapira B, Frydman L,. A continuous phase-modulated approach to spatial encoding in ultrafast 2D NMR spectroscopy. J Magn Reson 2005; 176: 107-114.
-
(2005)
J Magn Reson
, vol.176
, pp. 107-114
-
-
Tal, A.1
Shapira, B.2
Frydman, L.3
-
20
-
-
49049118660
-
Alias-free image reconstruction using Fresnel transform in the phase-scrambling Fourier imaging technique
-
Ito S, Yamada Y,. Alias-free image reconstruction using Fresnel transform in the phase-scrambling Fourier imaging technique. Magn Reson Med 2008; 60: 422-430.
-
(2008)
Magn Reson Med
, vol.60
, pp. 422-430
-
-
Ito, S.1
Yamada, Y.2
-
21
-
-
71049155475
-
High-definition, single-scan 2D MRI in inhomogeneous fields using spatial encoding methods
-
Ben-Eliezer N, Shrot Y, Frydman L,. High-definition, single-scan 2D MRI in inhomogeneous fields using spatial encoding methods. Magn Reson Imaging 2010; 28: 77-86.
-
(2010)
Magn Reson Imaging
, vol.28
, pp. 77-86
-
-
Ben-Eliezer, N.1
Shrot, Y.2
Frydman, L.3
-
22
-
-
77955231576
-
High fidelity magnetic resonance imaging by frequency sweep encoding and Fourier decoding
-
Shen J, Xiang Y,. High fidelity magnetic resonance imaging by frequency sweep encoding and Fourier decoding. J Magn Reson 2010; 204: 200-207.
-
(2010)
J Magn Reson
, vol.204
, pp. 200-207
-
-
Shen, J.1
Xiang, Y.2
-
23
-
-
77955200345
-
Spread spectrum for compressed sensing techniques in magnetic resonance imaging
-
Wiaux Y, Puy G, Gruetter R, Thiran J-P, Van De Ville D, Vandergheynst P,. Spread spectrum for compressed sensing techniques in magnetic resonance imaging. Proc IEEE Int Symp Biomed Imaging 2010; 756-759.
-
(2010)
Proc IEEE Int Symp Biomed Imaging
, pp. 756-759
-
-
Wiaux, Y.1
Puy, G.2
Gruetter, R.3
Thiran, J.-P.4
Van De Ville, D.5
Vandergheynst, P.6
-
24
-
-
79951839905
-
Simultaneously driven linear and nonlinear spatial encoding fields in MRI
-
Gallichan D, Cocosco CA, Dewdney A, et al. Simultaneously driven linear and nonlinear spatial encoding fields in MRI. Magn Reson Med 2010; 65: 702-714.
-
(2010)
Magn Reson Med
, vol.65
, pp. 702-714
-
-
Gallichan, D.1
Cocosco, C.A.2
Dewdney, A.3
-
25
-
-
84861226959
-
Rapid MR image acquisition in the presence of background gradients
-
Noll DC,. Rapid MR image acquisition in the presence of background gradients. IEEE Trans Med Imag 2002; 24: 725-728.
-
(2002)
IEEE Trans Med Imag
, vol.24
, pp. 725-728
-
-
Noll, D.C.1
-
26
-
-
0025470738
-
Spatially-localized NMR spectroscopy employing an inhomogeneous surface-spoiling magnetic field gradient. 1. Phase coherence spoiling theory and gradient coil design
-
Chen W, Ackerman JJ,. Spatially-localized NMR spectroscopy employing an inhomogeneous surface-spoiling magnetic field gradient. 1. Phase coherence spoiling theory and gradient coil design. NMR Biomed 1990; 3: 147-157.
-
(1990)
NMR Biomed
, vol.3
, pp. 147-157
-
-
Chen, W.1
Ackerman, J.J.2
-
28
-
-
78349235374
-
Reconstruction of MRI data encoded with arbitrarily shaped, curvilinear, non-bijective magnetic fields
-
Schultz G, Ullman P, Lehr H, Welz A, Hennig J, Zaitsev M,. Reconstruction of MRI data encoded with arbitrarily shaped, curvilinear, non-bijective magnetic fields. Magn Reson Med 2010; 64: 1390-1403.
-
(2010)
Magn Reson Med
, vol.64
, pp. 1390-1403
-
-
Schultz, G.1
Ullman, P.2
Lehr, H.3
Welz, A.4
Hennig, J.5
Zaitsev, M.6
-
29
-
-
78349264693
-
Development of a PatLoc Gradient Insert for Human Head Imaging
-
Welz AM, Zaitsev M, Jia F, Lieu Z, Korvink J, Schmidt H, Lehr H, Post H, Dewdney A, Hennig J,. Development of a PatLoc Gradient Insert for Human Head Imaging. In: Proceedings of the 16th Annual Meeting of the ISMRM, Toronto, Canada, 2008; Abstract 762.
-
(2008)
Proceedings of the 16th Annual Meeting of the ISMRM, Toronto, Canada, Abstract 762
-
-
Welz, A.M.1
Zaitsev, M.2
Jia, F.3
Lieu, Z.4
Korvink, J.5
Schmidt, H.6
Lehr, H.7
Post, H.8
Dewdney, A.9
Hennig, J.10
-
30
-
-
79951820931
-
Safety considerations for a Patloc Gradient Insert Coil for Human Head Imaging
-
Cocosco C, Dewdney A, Dietz P, Semmler M, Welz AM, Gallichan D, Weber H, Schultz G, Hennig H, Zaitsev M,. Safety considerations for a Patloc Gradient Insert Coil for Human Head Imaging. In: Proceedings of the 18th Annual Meeting of ISMRM, Stockholm, Sweden, 2010; Abstract 3946.
-
(2010)
Proceedings of the 18th Annual Meeting of ISMRM, Stockholm, Sweden, Abstract 3946
-
-
Cocosco, C.1
Dewdney, A.2
Dietz, P.3
Semmler, M.4
Welz, A.M.5
Gallichan, D.6
Weber, H.7
Schultz, G.8
Hennig, H.9
Zaitsev, M.10
-
31
-
-
33744534543
-
Parallel RF transmission in MRI
-
Katscher U, Börnert P,. Parallel RF transmission in MRI. NMR Biomed 2006; 19: 393-400.
-
(2006)
NMR Biomed
, vol.19
, pp. 393-400
-
-
Katscher, U.1
Börnert, P.2
-
32
-
-
33645784534
-
Improved gradient-echo 3D magnetic resonance imaging using pseudo-echoes created by frequency-swept pulses
-
Park J-Y, DelaBarre L, Garwood M,. Improved gradient-echo 3D magnetic resonance imaging using pseudo-echoes created by frequency-swept pulses. Magn Reson Med 2006; 55: 848-857.
-
(2006)
Magn Reson Med
, vol.55
, pp. 848-857
-
-
Park, J.-Y.1
Delabarre, L.2
Garwood, M.3
-
33
-
-
35048844132
-
RASER: A new ultrafast magnetic resonance imaging method
-
Chamberlain R, Park JY, Corum C, Yacoub E, Ugurbil K, Jack CR Jr, Garwood M,. RASER: a new ultrafast magnetic resonance imaging method. Magn Reson Med 2007; 58: 794-799.
-
(2007)
Magn Reson Med
, vol.58
, pp. 794-799
-
-
Chamberlain, R.1
Park, J.Y.2
Corum, C.3
Yacoub, E.4
Ugurbil, K.5
Jack, Jr.C.R.6
Garwood, M.7
-
34
-
-
0002547750
-
Stimulated echo imaging
-
Frahm J, Merboldt KD, Hanicke W, Haase A,. Stimulated echo imaging. J Magn Reson 1985; 64: 81-93.
-
(1985)
J Magn Reson
, vol.64
, pp. 81-93
-
-
Frahm, J.1
Merboldt, K.D.2
Hanicke, W.3
Haase, A.4
-
35
-
-
41849135374
-
Parallel imaging in non-bijective, curvilinear magnetic field gradients: A concept study
-
Hennig J, Welz AM, Schultz G, Korvink J, Liu Z, Speck O, Zaitsev M,. Parallel imaging in non-bijective, curvilinear magnetic field gradients: a concept study. MAGMA 2008; 21: 5-14.
-
(2008)
MAGMA
, vol.21
, pp. 5-14
-
-
Hennig, J.1
Welz, A.M.2
Schultz, G.3
Korvink, J.4
Liu, Z.5
Speck, O.6
Zaitsev, M.7
-
36
-
-
77955112765
-
O-space imaging: Highly efficient parallel imaging using second-order nonlinear fields as encoding gradients with no phase encoding
-
Stockmann JP, Ciris PA, Galiana G, Tam L, Constable RT,. O-space imaging: highly efficient parallel imaging using second-order nonlinear fields as encoding gradients with no phase encoding. Magn Reson Med 2010; 64: 447-456.
-
(2010)
Magn Reson Med
, vol.64
, pp. 447-456
-
-
Stockmann, J.P.1
Ciris, P.A.2
Galiana, G.3
Tam, L.4
Constable, R.T.5
|