메뉴 건너뛰기




Volumn 60, Issue 2, 2008, Pages 422-430

Alias-free image reconstruction using Fresnel transform in the phase-scrambling fourier imaging technique

Author keywords

Artifact; Field of view; Quadratic phase reconstruction; Sampling theorem; Scaling

Indexed keywords

ANTI-ALIASING; BIOMEDICAL SIGNAL PROCESSING; INVERSE PROBLEMS; INVERSE TRANSFORMS; MAGNETIC RESONANCE IMAGING;

EID: 49049118660     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.21672     Document Type: Article
Times cited : (21)

References (13)
  • 1
    • 0242385483 scopus 로고    scopus 로고
    • k-t BLAST and k-t SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
    • Tsao J, Boesiger P, Pruessmann KP. k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations. Magn Reson Med 2003;50:1031-1042.
    • (2003) Magn Reson Med , vol.50 , pp. 1031-1042
    • Tsao, J.1    Boesiger, P.2    Pruessmann, K.P.3
  • 2
  • 3
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
    • Sodickson DK, Manning WJ. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 1997;38:591-603.
    • (1997) Magn Reson Med , vol.38 , pp. 591-603
    • Sodickson, D.K.1    Manning, W.J.2
  • 6
    • 0034007629 scopus 로고    scopus 로고
    • Reduced aliasing artifact using variable-density k-space sampling trajectories
    • Tsai CM, Nishimura DG. Reduced aliasing artifact using variable-density k-space sampling trajectories. Magn Reson Med 2000;43:452-458.
    • (2000) Magn Reson Med , vol.43 , pp. 452-458
    • Tsai, C.M.1    Nishimura, D.G.2
  • 8
    • 38249028655 scopus 로고
    • Dynamic range improvement in NMR imaging using phase scrambling
    • Maudsley AA. Dynamic range improvement in NMR imaging using phase scrambling. J Magn Reson 1988;76:287-305.
    • (1988) J Magn Reson , vol.76 , pp. 287-305
    • Maudsley, A.A.1
  • 9
    • 0023913045 scopus 로고
    • Dynamic range compression in MRI by means of nonlinear gradient pulse
    • Wedeen VJ, Chao YS, Ackerman JL. Dynamic range compression in MRI by means of nonlinear gradient pulse. Magn Reson Med 1988;6:287-295.
    • (1988) Magn Reson Med , vol.6 , pp. 287-295
    • Wedeen, V.J.1    Chao, Y.S.2    Ackerman, J.L.3
  • 10
    • 0028850689 scopus 로고
    • Spatial encoding and reconstruction in MRI with quadratic phase profiles
    • Pipe JG. Spatial encoding and reconstruction in MRI with quadratic phase profiles. Magn Reson Med 1995;33:24-33.
    • (1995) Magn Reson Med , vol.33 , pp. 24-33
    • Pipe, J.G.1
  • 12
    • 0000073840 scopus 로고
    • NMR Fresnel transform imaging technique using a quadratic nonlinear field gradient
    • Yamada Y, Tanaka K, Abe Z. NMR Fresnel transform imaging technique using a quadratic nonlinear field gradient. Rev Sci Instrum 1992;63:5348-5358.
    • (1992) Rev Sci Instrum , vol.63 , pp. 5348-5358
    • Yamada, Y.1    Tanaka, K.2    Abe, Z.3
  • 13
    • 0037056349 scopus 로고    scopus 로고
    • Optical on-line running reconstruction of MR images in the phase scrambling-Fourier imaging technique
    • Ito S, Ono A, Yamada Y. Optical on-line running reconstruction of MR images in the phase scrambling-Fourier imaging technique. Appl Opt 2002;41:5527-5537.
    • (2002) Appl Opt , vol.41 , pp. 5527-5537
    • Ito, S.1    Ono, A.2    Yamada, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.