메뉴 건너뛰기




Volumn , Issue , 2011, Pages 001859-001864

Reconfiguration strategy for optimization of solar photovoltaic array under non-uniform illumination conditions

Author keywords

[No Author keywords available]

Indexed keywords

ARRAY CONFIGURATIONS; CELL ARRAY; CONVENTIONAL POWER; HIGH GAIN; HIGH VOLTAGE GAIN; LOCAL MAXIMUM; MAXIMUM POWER POINT; MULTIPLE-PEAK; NON-UNIFORM ILLUMINATION; OPERATING VOLTAGE; OUTPUT VOLTAGES; PARTIAL SHADING; POWER OPTIMIZATION; POWER-LOSSES; PV MODULES; RECONFIGURATION SCHEMES; SOLAR INSOLATION; SOLAR PHOTOVOLTAICS; SOLAR PVS;

EID: 84861018477     PISSN: 01608371     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/PVSC.2011.6186314     Document Type: Conference Paper
Times cited : (79)

References (10)
  • 1
    • 40849142550 scopus 로고    scopus 로고
    • Matlab-Based Modeling to Study the Effects of Partial Shading on PV Array Characteristics
    • March
    • H. Patel and V. Agarwal, "Matlab-Based Modeling to Study the Effects of Partial Shading on PV Array Characteristics," IEEE Transaction on Energy Conversion, vol. 23, March 2008, pp. 302-310.
    • (2008) IEEE Transaction on Energy Conversion , vol.23 , pp. 302-310
    • Patel, H.1    Agarwal, V.2
  • 3
    • 34548028682 scopus 로고    scopus 로고
    • Comparison of the Performance of Maximum PowerPoint Tracking Schemes Applied to Single Stage Grid Connected PV Systems
    • S.Jain, and V.Agrawal. " Comparison of the Performance of Maximum PowerPoint Tracking Schemes Applied to Single Stage Grid Connected PV Systems" IET Electrical Power Applications,2007,pp.753-762.
    • (2007) IET Electrical Power Applications , pp. 753-762
    • Jain, S.1    Agrawal, V.2
  • 4
    • 77955990660 scopus 로고    scopus 로고
    • A Returned Energy Architecture for Improved Photovoltaic System Efficiency
    • Y.Nimni, D. Shmilovitz, "A Returned Energy Architecture for Improved Photovoltaic System Efficiency," IEEE ISCAS, May 2010, pp. 2191-2194.
    • IEEE ISCAS, May 2010 , pp. 2191-2194
    • Nimni, Y.1    Shmilovitz, D.2
  • 5
    • 0025638149 scopus 로고
    • The Effect of Electrical Array Reconfiguration on the Performance of a PVPowered Volumetric Water Pump
    • December
    • Z.M.Salameh, F.Dagher, "The Effect of Electrical Array Reconfiguration on the Performance of a PVPowered Volumetric Water Pump," IEEE Transaction on Energy Conversion, vol 5, December 1990, pp. 653-658.
    • (1990) IEEE Transaction on Energy Conversion , vol.5 , pp. 653-658
    • Salameh, Z.M.1    Dagher, F.2
  • 6
    • 0032218422 scopus 로고    scopus 로고
    • A Method of Appropriate Electrical Array Reconfiguration Management for Photovoltaic Powered Car
    • Y.Auttawaitkul, et al., "A Method of Appropriate Electrical Array Reconfiguration Management for Photovoltaic Powered Car," IEEE APCCAS, 1998, pp. 201-204.
    • IEEE APCCAS, 1998 , pp. 201-204
    • Auttawaitkul, Y.1
  • 7
    • 70350376434 scopus 로고    scopus 로고
    • Electrical PV Array Reconfiguration Strategy for Energy Extraction Improvement in Grid-Connected PV Systems
    • Nov
    • G.Velasco-Quesada et al., "Electrical PV Array Reconfiguration Strategy for Energy Extraction Improvement in Grid-Connected PV Systems", IEEE Transactions on Industrial Electronics, vol. 56, no. 11, Nov 2009, pp. 4319-4331
    • (2009) IEEE Transactions on Industrial Electronics , vol.56 , Issue.11 , pp. 4319-4331
    • Velasco-Quesada, G.1
  • 8
    • 47049106822 scopus 로고    scopus 로고
    • An Adaptive Solar Photovoltaic Array using Model-Based Reconfiguration Algorithm
    • Jul
    • D. Nguyen and B. Lehman, "An Adaptive Solar Photovoltaic Array using Model-Based Reconfiguration Algorithm," IEEE. Ind. Electron., Vol.55, Jul 2008, pp. 2644-2654.
    • (2008) IEEE. Ind. Electron. , vol.55 , pp. 2644-2654
    • Nguyen, D.1    Lehman, B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.