메뉴 건너뛰기




Volumn , Issue , 2010, Pages 968-972

Dynamic power optimization of contoured flexible PV array under non-uniform illumination conditions

Author keywords

[No Author keywords available]

Indexed keywords

DYNAMIC POWER; GLOBAL MAXIMUM; INTEGRATED-TEST-SYSTEM; MAXIMUM POWER; NON-UNIFORM ILLUMINATION; OSCILLATORY BEHAVIORS; OUTPUT POWER; OUTPUT VOLTAGES; PARTIAL SHADING; PV ARRAYS; SMALL ENERGY; SOLAR ANGLE; SOLAR IRRADIANCES; STANDALONE APPLICATIONS; STATIC AND DYNAMIC; TRACKING ALGORITHM; VOLTAGE RATINGS;

EID: 78650130611     PISSN: 01608371     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/PVSC.2010.5614565     Document Type: Conference Paper
Times cited : (22)

References (8)
  • 1
    • 69949140340 scopus 로고    scopus 로고
    • Parameter extraction for flexible photovoltaic modules to determine the impact of FPV technologies on high insolation module performance
    • P. Sharma, S.P. Duttagupta, V. Agarwal, "Parameter Extraction for Flexible Photovoltaic Modules to Determine the Impact of FPV Technologies on High Insolation Module Performance" in SPIE Proceedings, vol. 7331, 2009.
    • (2009) SPIE Proceedings , vol.7331
    • Sharma, P.1    Duttagupta, S.P.2    Agarwal, V.3
  • 2
    • 40849142550 scopus 로고    scopus 로고
    • MATLAB-based modeling to study the effects of partial shading on PV array characteristics
    • H. Patel and V. Agarwal, "MATLAB-Based Modeling to Study the Effects of Partial Shading on PV Array Characteristics", IEEE Transactions on Energy Conversion, vol. 23, pp. 302-310, 2008.
    • (2008) IEEE Transactions on Energy Conversion , vol.23 , pp. 302-310
    • Patel, H.1    Agarwal, V.2
  • 3
    • 34249794869 scopus 로고    scopus 로고
    • Comparison of photovoltaic array maximum power point tracking techniques
    • T. Esram and P.L. Chapman, "Comparison of photovoltaic array maximum power point tracking techniques," IEEE Trans. on energy conversion, vol. 22 no. 2, pp. 439-449, 2007.
    • (2007) IEEE Trans. on Energy Conversion , vol.22 , Issue.2 , pp. 439-449
    • Esram, T.1    Chapman, P.L.2
  • 4
    • 34548028682 scopus 로고    scopus 로고
    • Comparison of the performance of maximum power point tracking schemes applied to single stage grid connected photovoltaic systems
    • S. Jain and V. Agarwal, "Comparison of the performance of maximum power point tracking schemes applied to single stage grid connected photovoltaic systems," lET Electr. Power Appl., vol. 1 no 5, pp. 753-762, 2007.
    • (2007) LET Electr. Power Appl. , vol.1 , Issue.5 , pp. 753-762
    • Jain, S.1    Agarwal, V.2
  • 5
    • 78650163386 scopus 로고    scopus 로고
    • M. Tech. Dissertation, Indian Institute of Technology, Bombay, India, July
    • Prasad V. Joshi, "Design of Mobile Integrated Power Plant," M. Tech. Dissertation, Indian Institute of Technology, Bombay, India, July 2008.
    • (2008) Design of Mobile Integrated Power Plant
    • Joshi, P.V.1
  • 7
    • 33645707855 scopus 로고    scopus 로고
    • An excellent operating point tracker of the solar cell power supply system
    • K. Kobayashi, H. Matsuo, and Y. Sekine, "An excellent operating point tracker of the solar cell power supply system," IEEE Transaction Ind. Electron., vol. 53 no 2, pp. 495 - 499, 2006.
    • (2006) IEEE Transaction Ind. Electron. , vol.53 , Issue.2 , pp. 495-499
    • Kobayashi, K.1    Matsuo, H.2    Sekine, Y.3
  • 8
    • 78650079436 scopus 로고    scopus 로고
    • http://www.powerupco.com/panels/unisolar/flx.pdf.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.