메뉴 건너뛰기




Volumn 1, Issue 3, 2011, Pages 320-337

Computational modelling and evaluation of cardiovascular response under pulsatile impeller pump support

Author keywords

Cardiovascular dynamics; CellML; Heart failure; Impeller pump; Numerical simulation; Pulsatile

Indexed keywords


EID: 84860869827     PISSN: 20428898     EISSN: 20428901     Source Type: Journal    
DOI: 10.1098/rsfs.2010.0039     Document Type: Article
Times cited : (21)

References (40)
  • 1
    • 0035172379 scopus 로고    scopus 로고
    • Can rotary blood pumps replace pulsatile devices?
    • (doi:10.1046/j. 1525-1594.2001.00870.x)
    • Takatani, S. 2001 Can rotary blood pumps replace pulsatile devices? Artif. Organs 25, 671-674. (doi:10.1046/j. 1525-1594.2001.00870.x)
    • (2001) Artif. Organs , vol.25 , pp. 671-674
    • Takatani, S.1
  • 2
    • 0032974674 scopus 로고    scopus 로고
    • Major organ function under mechanical support: Comparative studies of pulsatile and nonpulsatile circulation
    • (doi:10.1046/j.1525-1594.1999.06318.x)
    • Sezai, A. et al. 1999 Major organ function under mechanical support: comparative studies of pulsatile and nonpulsatile circulation. Artif. Organs 23, 280-285. (doi:10.1046/j.1525-1594.1999.06318.x)
    • (1999) Artif. Organs , vol.23 , pp. 280-285
    • Sezai, A.1
  • 3
    • 2542419343 scopus 로고    scopus 로고
    • Myths and truths of pulsatile and nonpulsatile perfusion during acute and chronic cardiac support
    • (doi:10.1111/j.1525-1594. 2004.00086.x)
    • Undar, A. 2004 Myths and truths of pulsatile and nonpulsatile perfusion during acute and chronic cardiac support. Artif. Organs 28, 439-443. (doi:10.1111/j.1525-1594. 2004.00086.x)
    • (2004) Artif. Organs , vol.28 , pp. 439-443
    • Undar, A.1
  • 4
    • 0035337515 scopus 로고    scopus 로고
    • A sensorless approach to control of a turbodynamic left ventricular assist system
    • (doi:10.1109/87.918900)
    • Choi, S., Antaki, J. F., Boston, J. R. & Thomas, D. 2001 A sensorless approach to control of a turbodynamic left ventricular assist system. IEEE Trans. Control Syst. Technol. 9, 473-482. (doi:10.1109/87.918900)
    • (2001) IEEE Trans. Control Syst. Technol. , vol.9 , pp. 473-482
    • Choi, S.1    Antaki, J.F.2    Boston, J.R.3    Thomas, D.4
  • 5
    • 0034827967 scopus 로고    scopus 로고
    • Development of the MEDOS/HIA DeltaStream extracorporeal rotary blood pump
    • (doi:10. 1046/j.1525-1594.2001.025005358.x)
    • Gobel, C., Arvand, A., Eilers, R., Marseille, O., Bals, C., Meyns, B., Flameng, W., Rau, G. & Reul, H. 2001 Development of the MEDOS/HIA DeltaStream extracorporeal rotary blood pump. Artif. Organs 25, 358-365. (doi:10. 1046/j.1525-1594.2001.025005358.x)
    • (2001) Artif. Organs , vol.25 , pp. 358-365
    • Gobel, C.1    Arvand, A.2    Eilers, R.3    Marseille, O.4    Bals, C.5    Meyns, B.6    Flameng, W.7    Rau, G.8    Reul, H.9
  • 6
    • 0030052416 scopus 로고    scopus 로고
    • Pulsatile impeller heart: A viable alternative to a problematic diaphragm heart
    • (doi:10.1016/1350-4533(95)00010-0)
    • Qian, K. X. 1996 Pulsatile impeller heart: a viable alternative to a problematic diaphragm heart. Med. Eng. Phys. 18, 57-66. (doi:10.1016/1350-4533(95)00010-0)
    • (1996) Med. Eng. Phys. , vol.18 , pp. 57-66
    • Qian, K.X.1
  • 7
    • 33644878560 scopus 로고    scopus 로고
    • Hemodynamic modes of ventricular assist with a rotary blood pump: Continuous, pulsatile, and failure
    • (doi:10.1097/01.mat. 0000179251.40649.45)
    • Vandenberghe, S., Segers, P., Antaki, J. F., Meyns, B. & Verdonck, P. R. 2005 Hemodynamic modes of ventricular assist with a rotary blood pump: continuous, pulsatile, and failure. ASAIO J. 51, 711-718. (doi:10.1097/01.mat. 0000179251.40649.45)
    • (2005) ASAIO J. , vol.51 , pp. 711-718
    • Vandenberghe, S.1    Segers, P.2    Antaki, J.F.3    Meyns, B.4    Verdonck, P.R.5
  • 8
    • 0348047551 scopus 로고    scopus 로고
    • Unloading effect of a rotary blood pump assessed by mathematical modeling
    • (doi:10.1111/j.1525-1594.2003.07198.x)
    • Vandenberghe, S., Segers, P., Meyns, B. & Verdonck, P. 2003 Unloading effect of a rotary blood pump assessed by mathematical modeling. Artif. Organs 27, 1094-1101. (doi:10.1111/j.1525-1594.2003.07198.x)
    • (2003) Artif. Organs , vol.27 , pp. 1094-1101
    • Vandenberghe, S.1    Segers, P.2    Meyns, B.3    Verdonck, P.4
  • 9
    • 0037898308 scopus 로고    scopus 로고
    • Control strategy for maintaining physiological perfusion with rotary blood pumps
    • (doi:10.1046/j.1525-1594.2003.07089.x)
    • Giridharan, G. & Skliar, M. 2003 Control strategy for maintaining physiological perfusion with rotary blood pumps. Artif. Organs 27, 639-648. (doi:10.1046/j.1525-1594.2003.07089.x)
    • (2003) Artif. Organs , vol.27 , pp. 639-648
    • Giridharan, G.1    Skliar, M.2
  • 11
    • 77955173514 scopus 로고    scopus 로고
    • Numerical modeling of hemodynamics with pulsatile impeller pump support
    • (doi:10. 1007/s10439-010-0001-y)
    • Shi, Y., Lawford, P. V. & Hose, D. R. 2010 Numerical modeling of hemodynamics with pulsatile impeller pump support. Ann. Biomed. Eng. 38, 2621-2634. (doi:10. 1007/s10439-010-0001-y)
    • (2010) Ann. Biomed. Eng. , vol.38 , pp. 2621-2634
    • Shi, Y.1    Lawford, P.V.2    Hose, D.R.3
  • 12
    • 0031888725 scopus 로고    scopus 로고
    • Physiological control of a total artificial heart: Conductance and arterial pressure based control
    • Abe, Y. et al. 1998 Physiological control of a total artificial heart: conductance and arterial pressure based control. J. Appl. Physiol. 84, 868-876.
    • (1998) J. Appl. Physiol. , vol.84 , pp. 868-876
    • Abe, Y.1
  • 13
    • 14044266346 scopus 로고    scopus 로고
    • Optimum control of the Hemopump as a left-ventricular assist device
    • (doi:10.1007/BF02345135)
    • He, P., Bai, J. & Xia, D. D. 2005 Optimum control of the Hemopump as a left-ventricular assist device. Med. Biol. Eng. Comput. 43, 136-141. (doi:10.1007/BF02345135)
    • (2005) Med. Biol. Eng. Comput. , vol.43 , pp. 136-141
    • He, P.1    Bai, J.2    Xia, D.D.3
  • 14
    • 4143083656 scopus 로고    scopus 로고
    • Fuzzy logic automatic control of the Phoenix-7 total artificial heart
    • (doi:10.1007/s10047-004-0249-9)
    • Hsu, H. 2004 Fuzzy logic automatic control of the Phoenix-7 total artificial heart. J. Artif. Organs 7, 69-76. (doi:10.1007/s10047-004-0249-9)
    • (2004) J. Artif. Organs , vol.7 , pp. 69-76
    • Hsu, H.1
  • 15
    • 0026848795 scopus 로고
    • An optimal controller for an electric ventricular assist device: Theory, implementation and testing
    • (doi:10.1109/10.126612)
    • Klute, G. K., Tasch, U. & Geselowitz, D. B. 1992 An optimal controller for an electric ventricular assist device: theory, implementation and testing. IEEE Trans. Biomed. Eng. 39, 394-403. (doi:10.1109/10.126612)
    • (1992) IEEE Trans. Biomed. Eng. , vol.39 , pp. 394-403
    • Klute, G.K.1    Tasch, U.2    Geselowitz, D.B.3
  • 16
    • 12244273688 scopus 로고    scopus 로고
    • Progress in the control system of the undulation pump total artificial heart
    • (doi:10.1046/j.1525-1594.2003.07174.x)
    • Saito, I. et al. 1999 Progress in the control system of the undulation pump total artificial heart. Artif. Organs 27, 27-33. (doi:10.1046/j.1525-1594.2003.07174.x)
    • (1999) Artif. Organs , vol.27 , pp. 27-33
    • Saito, I.1
  • 17
    • 0026832844 scopus 로고
    • An automatic control algorithm for the optimal driving of the ventricular-assist device
    • (doi:10.1109/10.125009)
    • Yoshizawa, M., Takeda, H., Watanabe, T., Miura, M., Yambe, T., Katahira, Y. & Nitta, S.-I. 1992 An automatic control algorithm for the optimal driving of the ventricular-assist device. IEEE Trans. Biomed. Eng. 39, 243-251. (doi:10.1109/10.125009)
    • (1992) IEEE Trans. Biomed. Eng. , vol.39 , pp. 243-251
    • Yoshizawa, M.1    Takeda, H.2    Watanabe, T.3    Miura, M.4    Yambe, T.5    Katahira, Y.6    Nitta, S.-I.7
  • 18
    • 0025388857 scopus 로고
    • Left atrial pressure controller design for an artificial heart
    • (doi:10.1109/10.46256)
    • Kitamura, T. 1990 Left atrial pressure controller design for an artificial heart. IEEE Trans. Biomed. Eng. 37, 164-169. (doi:10.1109/10.46256)
    • (1990) IEEE Trans. Biomed. Eng. , vol.37 , pp. 164-169
    • Kitamura, T.1
  • 20
    • 12244265469 scopus 로고    scopus 로고
    • Outflow control for avoiding atrial suction in a continuous flow total artificial heart
    • (doi:10.1046/j. 1525-1594.2003.07185.x)
    • Olegario, P. S., Yoshizawa, M., Tanaka, A., Abe, K., Takeda, H., Yambe, T. & Nitta, S.-I. 2003 Outflow control for avoiding atrial suction in a continuous flow total artificial heart. Artif. Organs 27, 92-98. (doi:10.1046/j. 1525-1594.2003.07185.x)
    • (2003) Artif. Organs , vol.27 , pp. 92-98
    • Olegario, P.S.1    Yoshizawa, M.2    Tanaka, A.3    Abe, K.4    Takeda, H.5    Yambe, T.6    Nitta, S.-I.7
  • 21
    • 0036430025 scopus 로고    scopus 로고
    • Physiological control algorithms for rotary blood pumps using pressure sensor input
    • (doi:10.1046/j. 1525-1594.2002.07126.x)
    • Bullister, E., Reich, S. & Slueta, J. 2002 Physiological control algorithms for rotary blood pumps using pressure sensor input. Artif. Organs 26, 931-938. (doi:10.1046/j. 1525-1594.2002.07126.x)
    • (2002) Artif. Organs , vol.26 , pp. 931-938
    • Bullister, E.1    Reich, S.2    Slueta, J.3
  • 22
    • 0026881772 scopus 로고
    • Optimal controller for intraaortic balloon pumping
    • (doi:10.1109/10.141201)
    • Barnea, O., Smith, B. T., Dubin, S., Moore, T. W. & Jaron, D. 1992 Optimal controller for intraaortic balloon pumping. IEEE Trans. Biomed. Eng. 39, 629-634. (doi:10.1109/10.141201)
    • (1992) IEEE Trans. Biomed. Eng. , vol.39 , pp. 629-634
    • Barnea, O.1    Smith, B.T.2    Dubin, S.3    Moore, T.W.4    Jaron, D.5
  • 23
    • 0037880523 scopus 로고    scopus 로고
    • Operating point control system for a continuous flow artificial heart: In vitro study
    • (doi:10.1097/01.MAT.0000065376.28871.A8)
    • Kosaka, R. et al. 2003 Operating point control system for a continuous flow artificial heart: in vitro study. ASAIO J. 49, 259-264. (doi:10.1097/01.MAT.0000065376.28871.A8)
    • (2003) ASAIO J. , vol.49 , pp. 259-264
    • Kosaka, R.1
  • 24
    • 0242301757 scopus 로고    scopus 로고
    • An advanced physiological controller design for a left ventricular assist device to prevent left ventricular collapse
    • (doi:10. 1046/j.1525-1594.2003.00032.x)
    • Wu, Y., Allaire, P., Tao, G., Wood, H., Olsen, D. & Tribble, C. 2003 An advanced physiological controller design for a left ventricular assist device to prevent left ventricular collapse. Artif. Organs 27, 926-930. (doi:10. 1046/j.1525-1594.2003.00032.x)
    • (2003) Artif. Organs , vol.27 , pp. 926-930
    • Wu, Y.1    Allaire, P.2    Tao, G.3    Wood, H.4    Olsen, D.5    Tribble, C.6
  • 25
    • 0033017790 scopus 로고    scopus 로고
    • Motor feedback physiological control for a continuous flow ventricular assist device
    • (doi:10.1046/j.1525-1594. 1999.06386.x)
    • Waters, T. et al. 1999 Motor feedback physiological control for a continuous flow ventricular assist device. Artif. Organs 23, 480-486. (doi:10.1046/j.1525-1594. 1999.06386.x)
    • (1999) Artif. Organs , vol.23 , pp. 480-486
    • Waters, T.1
  • 26
    • 0025388875 scopus 로고
    • Design and control of the atrio-aortic left ventricular assist device based on O2 consumption
    • (doi:10.1109/10.46252)
    • Drzewiecki, G. M., Pilla, J. & Welkowitz, W. 1990 Design and control of the atrio-aortic left ventricular assist device based on O2 consumption. IEEE Trans. Biomed. Eng. 37, 128-137. (doi:10.1109/10.46252)
    • (1990) IEEE Trans. Biomed. Eng. , vol.37 , pp. 128-137
    • Drzewiecki, G.M.1    Pilla, J.2    Welkowitz, W.3
  • 27
    • 0034326322 scopus 로고    scopus 로고
    • Mixed venous oxygen saturation as a promising parameter for physiological control of total artificial heart
    • (doi:10.1097/00002480-200011000-00020)
    • Nakamura, M. et al. 2000 Mixed venous oxygen saturation as a promising parameter for physiological control of total artificial heart. ASAIO J. 46, 761-766. (doi:10.1097/00002480-200011000-00020)
    • (2000) ASAIO J. , vol.46 , pp. 761-766
    • Nakamura, M.1
  • 29
    • 33845491760 scopus 로고    scopus 로고
    • Numerical simulation of cardiovascular dynamics with left heart failure and inseries pulsatile ventricular assist device
    • (doi:10.1111/j.1525-1594.2006.00326.x)
    • Shi, Y. & Korakianitis, T. 2006 Numerical simulation of cardiovascular dynamics with left heart failure and inseries pulsatile ventricular assist device. Artif. Organs 30, 929-948. (doi:10.1111/j.1525-1594.2006.00326.x)
    • (2006) Artif. Organs , vol.30 , pp. 929-948
    • Shi, Y.1    Korakianitis, T.2
  • 30
    • 85020735237 scopus 로고    scopus 로고
    • See
    • CellML. 2008 See http://www.cellml.org.
    • (2008) CellML
  • 31
    • 1342329447 scopus 로고    scopus 로고
    • An overview of CellML 1.1, a biological model description language
    • (doi:10.1177/0037549703040939)
    • Cuellar, A. A., Lloyd, C. M., Nielsen, P. F., Bullivant, D. P., Nickerson, D. P. & Hunter, P. J. 2003 An overview of CellML 1.1, a biological model description language. Simulation 79, 740-747. (doi:10.1177/0037549703040939)
    • (2003) Simulation , vol.79 , pp. 740-747
    • Cuellar, A.A.1    Lloyd, C.M.2    Nielsen, P.F.3    Bullivant, D.P.4    Nickerson, D.P.5    Hunter, P.J.6
  • 33
    • 0032816083 scopus 로고    scopus 로고
    • Defining pulsatile perfusion: Quantification in terms of energy equivalent pressure
    • (doi:10. 1046/j.1525-1594.1999.06409.x)
    • Undar, A., Frazier, O. H. & Fraser Jr, C. D. 1999 Defining pulsatile perfusion: quantification in terms of energy equivalent pressure. Artif. Organs 23, 712-716. (doi:10. 1046/j.1525-1594.1999.06409.x)
    • (1999) Artif. Organs , vol.23 , pp. 712-716
    • Undar, A.1    Frazier, O.H.2    Fraser Jr., C.D.3
  • 34
    • 3342991843 scopus 로고    scopus 로고
    • Reverse remodeling in heart failure-fact or fiction?
    • (doi:10. 1016/j.ehjsup.2004.05.019)
    • Pieske, B. 2004 Reverse remodeling in heart failure-fact or fiction? Eur. Heart J. Suppl. 6, D66-D78. (doi:10. 1016/j.ehjsup.2004.05.019)
    • (2004) Eur. Heart J. Suppl. , vol.6
    • Pieske, B.1
  • 36
    • 33745826316 scopus 로고    scopus 로고
    • Numerical simulation of cardiovascular dynamics with healthy and diseased heart valves
    • (doi:10.1016/j.jbiomech. 2005.06.016)
    • Korakianitis, T. & Shi, Y. 2006 Numerical simulation of cardiovascular dynamics with healthy and diseased heart valves. J. Biomech. 39, 1964-1982. (doi:10.1016/j.jbiomech. 2005.06.016)
    • (2006) J. Biomech. , vol.39 , pp. 1964-1982
    • Korakianitis, T.1    Shi, Y.2
  • 38
    • 34249011417 scopus 로고    scopus 로고
    • Design features, developmental status, and experimental results with the Heartmate III centrifugal left ventricular assist system with a magnetically levitated rotor
    • (doi:10. 1097/MAT.0b013e3180536694)
    • Farrar, D. J., Bourque, K., Dague, C. P., Cotter, C. J. & Poirier, V. L. 2007 Design features, developmental status, and experimental results with the Heartmate III centrifugal left ventricular assist system with a magnetically levitated rotor. ASAIO J. 53, 310-315. (doi:10. 1097/MAT.0b013e3180536694)
    • (2007) ASAIO J. , vol.53 , pp. 310-315
    • Farrar, D.J.1    Bourque, K.2    Dague, C.P.3    Cotter, C.J.4    Poirier, V.L.5
  • 39
    • 34249014596 scopus 로고    scopus 로고
    • Effect of continuous and pulsatile flow left ventricular assist on pulsatility in a pediatric animal model of left ventricular dysfunction: Pilot observations
    • (doi:10.1097/MAT. 0b013e318050d210)
    • Pantalos, G. M., Giridharan, G., Colyer, J., Mitchell, M., Speakman, J., Lucci, C., Johnson, G., Gartner, M. & Koenig, S. C. 2007 Effect of continuous and pulsatile flow left ventricular assist on pulsatility in a pediatric animal model of left ventricular dysfunction: pilot observations. ASAIO J. 53, 385-391. (doi:10.1097/MAT. 0b013e318050d210)
    • (2007) ASAIO J. , vol.53 , pp. 385-391
    • Pantalos, G.M.1    Giridharan, G.2    Colyer, J.3    Mitchell, M.4    Speakman, J.5    Lucci, C.6    Johnson, G.7    Gartner, M.8    Koenig, S.C.9
  • 40
    • 0031871850 scopus 로고    scopus 로고
    • The type of aortic cannula and membrane oxygenator affect the pulsatile waveform morphology produced by a neonate-infant cardiopulmonary bypass system in vivo
    • (doi:10.1046/j.1525-1594. 1998.06017.x)
    • Undar, A., Lodge, A. J., Daggett, C. W., Runge, T. M., Ungerleider, R. M. & Calhoon, J. H. 1998 The type of aortic cannula and membrane oxygenator affect the pulsatile waveform morphology produced by a neonate-infant cardiopulmonary bypass system in vivo. Artif. Organs 22, 681-686. (doi:10.1046/j.1525-1594. 1998.06017.x)
    • (1998) Artif. Organs , vol.22 , pp. 681-686
    • Undar, A.1    Lodge, A.J.2    Daggett, C.W.3    Runge, T.M.4    Ungerleider, R.M.5    Calhoon, J.H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.