-
1
-
-
0035172379
-
Can rotary blood pumps replace pulsatile devices?
-
(doi:10.1046/j. 1525-1594.2001.00870.x)
-
Takatani, S. 2001 Can rotary blood pumps replace pulsatile devices? Artif. Organs 25, 671-674. (doi:10.1046/j. 1525-1594.2001.00870.x)
-
(2001)
Artif. Organs
, vol.25
, pp. 671-674
-
-
Takatani, S.1
-
2
-
-
0032974674
-
Major organ function under mechanical support: Comparative studies of pulsatile and nonpulsatile circulation
-
(doi:10.1046/j.1525-1594.1999.06318.x)
-
Sezai, A. et al. 1999 Major organ function under mechanical support: comparative studies of pulsatile and nonpulsatile circulation. Artif. Organs 23, 280-285. (doi:10.1046/j.1525-1594.1999.06318.x)
-
(1999)
Artif. Organs
, vol.23
, pp. 280-285
-
-
Sezai, A.1
-
3
-
-
2542419343
-
Myths and truths of pulsatile and nonpulsatile perfusion during acute and chronic cardiac support
-
(doi:10.1111/j.1525-1594. 2004.00086.x)
-
Undar, A. 2004 Myths and truths of pulsatile and nonpulsatile perfusion during acute and chronic cardiac support. Artif. Organs 28, 439-443. (doi:10.1111/j.1525-1594. 2004.00086.x)
-
(2004)
Artif. Organs
, vol.28
, pp. 439-443
-
-
Undar, A.1
-
4
-
-
0035337515
-
A sensorless approach to control of a turbodynamic left ventricular assist system
-
(doi:10.1109/87.918900)
-
Choi, S., Antaki, J. F., Boston, J. R. & Thomas, D. 2001 A sensorless approach to control of a turbodynamic left ventricular assist system. IEEE Trans. Control Syst. Technol. 9, 473-482. (doi:10.1109/87.918900)
-
(2001)
IEEE Trans. Control Syst. Technol.
, vol.9
, pp. 473-482
-
-
Choi, S.1
Antaki, J.F.2
Boston, J.R.3
Thomas, D.4
-
5
-
-
0034827967
-
Development of the MEDOS/HIA DeltaStream extracorporeal rotary blood pump
-
(doi:10. 1046/j.1525-1594.2001.025005358.x)
-
Gobel, C., Arvand, A., Eilers, R., Marseille, O., Bals, C., Meyns, B., Flameng, W., Rau, G. & Reul, H. 2001 Development of the MEDOS/HIA DeltaStream extracorporeal rotary blood pump. Artif. Organs 25, 358-365. (doi:10. 1046/j.1525-1594.2001.025005358.x)
-
(2001)
Artif. Organs
, vol.25
, pp. 358-365
-
-
Gobel, C.1
Arvand, A.2
Eilers, R.3
Marseille, O.4
Bals, C.5
Meyns, B.6
Flameng, W.7
Rau, G.8
Reul, H.9
-
6
-
-
0030052416
-
Pulsatile impeller heart: A viable alternative to a problematic diaphragm heart
-
(doi:10.1016/1350-4533(95)00010-0)
-
Qian, K. X. 1996 Pulsatile impeller heart: a viable alternative to a problematic diaphragm heart. Med. Eng. Phys. 18, 57-66. (doi:10.1016/1350-4533(95)00010-0)
-
(1996)
Med. Eng. Phys.
, vol.18
, pp. 57-66
-
-
Qian, K.X.1
-
7
-
-
33644878560
-
Hemodynamic modes of ventricular assist with a rotary blood pump: Continuous, pulsatile, and failure
-
(doi:10.1097/01.mat. 0000179251.40649.45)
-
Vandenberghe, S., Segers, P., Antaki, J. F., Meyns, B. & Verdonck, P. R. 2005 Hemodynamic modes of ventricular assist with a rotary blood pump: continuous, pulsatile, and failure. ASAIO J. 51, 711-718. (doi:10.1097/01.mat. 0000179251.40649.45)
-
(2005)
ASAIO J.
, vol.51
, pp. 711-718
-
-
Vandenberghe, S.1
Segers, P.2
Antaki, J.F.3
Meyns, B.4
Verdonck, P.R.5
-
8
-
-
0348047551
-
Unloading effect of a rotary blood pump assessed by mathematical modeling
-
(doi:10.1111/j.1525-1594.2003.07198.x)
-
Vandenberghe, S., Segers, P., Meyns, B. & Verdonck, P. 2003 Unloading effect of a rotary blood pump assessed by mathematical modeling. Artif. Organs 27, 1094-1101. (doi:10.1111/j.1525-1594.2003.07198.x)
-
(2003)
Artif. Organs
, vol.27
, pp. 1094-1101
-
-
Vandenberghe, S.1
Segers, P.2
Meyns, B.3
Verdonck, P.4
-
9
-
-
0037898308
-
Control strategy for maintaining physiological perfusion with rotary blood pumps
-
(doi:10.1046/j.1525-1594.2003.07089.x)
-
Giridharan, G. & Skliar, M. 2003 Control strategy for maintaining physiological perfusion with rotary blood pumps. Artif. Organs 27, 639-648. (doi:10.1046/j.1525-1594.2003.07089.x)
-
(2003)
Artif. Organs
, vol.27
, pp. 639-648
-
-
Giridharan, G.1
Skliar, M.2
-
10
-
-
0034823945
-
Control strategy for rotary blood pumps
-
(doi:10.1046/j.1525-1594.2001.025005366.x)
-
Ohuchi, K., Kikugawa, D., Takahashi, K., Uemura, M., Nakamura, M., Murakami, T., Sakamoto, T. & Takatani, S. 2001 Control strategy for rotary blood pumps. Artif. Organs 25, 366-370. (doi:10.1046/j.1525-1594.2001.025005366.x)
-
(2001)
Artif. Organs
, vol.25
, pp. 366-370
-
-
Ohuchi, K.1
Kikugawa, D.2
Takahashi, K.3
Uemura, M.4
Nakamura, M.5
Murakami, T.6
Sakamoto, T.7
Takatani, S.8
-
11
-
-
77955173514
-
Numerical modeling of hemodynamics with pulsatile impeller pump support
-
(doi:10. 1007/s10439-010-0001-y)
-
Shi, Y., Lawford, P. V. & Hose, D. R. 2010 Numerical modeling of hemodynamics with pulsatile impeller pump support. Ann. Biomed. Eng. 38, 2621-2634. (doi:10. 1007/s10439-010-0001-y)
-
(2010)
Ann. Biomed. Eng.
, vol.38
, pp. 2621-2634
-
-
Shi, Y.1
Lawford, P.V.2
Hose, D.R.3
-
12
-
-
0031888725
-
Physiological control of a total artificial heart: Conductance and arterial pressure based control
-
Abe, Y. et al. 1998 Physiological control of a total artificial heart: conductance and arterial pressure based control. J. Appl. Physiol. 84, 868-876.
-
(1998)
J. Appl. Physiol.
, vol.84
, pp. 868-876
-
-
Abe, Y.1
-
13
-
-
14044266346
-
Optimum control of the Hemopump as a left-ventricular assist device
-
(doi:10.1007/BF02345135)
-
He, P., Bai, J. & Xia, D. D. 2005 Optimum control of the Hemopump as a left-ventricular assist device. Med. Biol. Eng. Comput. 43, 136-141. (doi:10.1007/BF02345135)
-
(2005)
Med. Biol. Eng. Comput.
, vol.43
, pp. 136-141
-
-
He, P.1
Bai, J.2
Xia, D.D.3
-
14
-
-
4143083656
-
Fuzzy logic automatic control of the Phoenix-7 total artificial heart
-
(doi:10.1007/s10047-004-0249-9)
-
Hsu, H. 2004 Fuzzy logic automatic control of the Phoenix-7 total artificial heart. J. Artif. Organs 7, 69-76. (doi:10.1007/s10047-004-0249-9)
-
(2004)
J. Artif. Organs
, vol.7
, pp. 69-76
-
-
Hsu, H.1
-
15
-
-
0026848795
-
An optimal controller for an electric ventricular assist device: Theory, implementation and testing
-
(doi:10.1109/10.126612)
-
Klute, G. K., Tasch, U. & Geselowitz, D. B. 1992 An optimal controller for an electric ventricular assist device: theory, implementation and testing. IEEE Trans. Biomed. Eng. 39, 394-403. (doi:10.1109/10.126612)
-
(1992)
IEEE Trans. Biomed. Eng.
, vol.39
, pp. 394-403
-
-
Klute, G.K.1
Tasch, U.2
Geselowitz, D.B.3
-
16
-
-
12244273688
-
Progress in the control system of the undulation pump total artificial heart
-
(doi:10.1046/j.1525-1594.2003.07174.x)
-
Saito, I. et al. 1999 Progress in the control system of the undulation pump total artificial heart. Artif. Organs 27, 27-33. (doi:10.1046/j.1525-1594.2003.07174.x)
-
(1999)
Artif. Organs
, vol.27
, pp. 27-33
-
-
Saito, I.1
-
17
-
-
0026832844
-
An automatic control algorithm for the optimal driving of the ventricular-assist device
-
(doi:10.1109/10.125009)
-
Yoshizawa, M., Takeda, H., Watanabe, T., Miura, M., Yambe, T., Katahira, Y. & Nitta, S.-I. 1992 An automatic control algorithm for the optimal driving of the ventricular-assist device. IEEE Trans. Biomed. Eng. 39, 243-251. (doi:10.1109/10.125009)
-
(1992)
IEEE Trans. Biomed. Eng.
, vol.39
, pp. 243-251
-
-
Yoshizawa, M.1
Takeda, H.2
Watanabe, T.3
Miura, M.4
Yambe, T.5
Katahira, Y.6
Nitta, S.-I.7
-
18
-
-
0025388857
-
Left atrial pressure controller design for an artificial heart
-
(doi:10.1109/10.46256)
-
Kitamura, T. 1990 Left atrial pressure controller design for an artificial heart. IEEE Trans. Biomed. Eng. 37, 164-169. (doi:10.1109/10.46256)
-
(1990)
IEEE Trans. Biomed. Eng.
, vol.37
, pp. 164-169
-
-
Kitamura, T.1
-
19
-
-
0021558328
-
Control strategies for artificial hearts and assist devices
-
In Los Angeles, CA, 15-17 September 1984
-
McInnis, B. C., Lu, P. C. & Wang, J. C. 1984 Control strategies for artificial hearts and assist devices. In Proc. 6th Annual Meeting of IEEE Frontiers for Engineering and Computing in Health Care, Los Angeles, CA, 15-17 September 1984, pp. 21-22.
-
(1984)
Proc. 6th Annual Meeting of IEEE Frontiers for Engineering and Computing in Health Care
, pp. 21-22
-
-
McInnis, B.C.1
Lu, P.C.2
Wang, J.C.3
-
20
-
-
12244265469
-
Outflow control for avoiding atrial suction in a continuous flow total artificial heart
-
(doi:10.1046/j. 1525-1594.2003.07185.x)
-
Olegario, P. S., Yoshizawa, M., Tanaka, A., Abe, K., Takeda, H., Yambe, T. & Nitta, S.-I. 2003 Outflow control for avoiding atrial suction in a continuous flow total artificial heart. Artif. Organs 27, 92-98. (doi:10.1046/j. 1525-1594.2003.07185.x)
-
(2003)
Artif. Organs
, vol.27
, pp. 92-98
-
-
Olegario, P.S.1
Yoshizawa, M.2
Tanaka, A.3
Abe, K.4
Takeda, H.5
Yambe, T.6
Nitta, S.-I.7
-
21
-
-
0036430025
-
Physiological control algorithms for rotary blood pumps using pressure sensor input
-
(doi:10.1046/j. 1525-1594.2002.07126.x)
-
Bullister, E., Reich, S. & Slueta, J. 2002 Physiological control algorithms for rotary blood pumps using pressure sensor input. Artif. Organs 26, 931-938. (doi:10.1046/j. 1525-1594.2002.07126.x)
-
(2002)
Artif. Organs
, vol.26
, pp. 931-938
-
-
Bullister, E.1
Reich, S.2
Slueta, J.3
-
22
-
-
0026881772
-
Optimal controller for intraaortic balloon pumping
-
(doi:10.1109/10.141201)
-
Barnea, O., Smith, B. T., Dubin, S., Moore, T. W. & Jaron, D. 1992 Optimal controller for intraaortic balloon pumping. IEEE Trans. Biomed. Eng. 39, 629-634. (doi:10.1109/10.141201)
-
(1992)
IEEE Trans. Biomed. Eng.
, vol.39
, pp. 629-634
-
-
Barnea, O.1
Smith, B.T.2
Dubin, S.3
Moore, T.W.4
Jaron, D.5
-
23
-
-
0037880523
-
Operating point control system for a continuous flow artificial heart: In vitro study
-
(doi:10.1097/01.MAT.0000065376.28871.A8)
-
Kosaka, R. et al. 2003 Operating point control system for a continuous flow artificial heart: in vitro study. ASAIO J. 49, 259-264. (doi:10.1097/01.MAT.0000065376.28871.A8)
-
(2003)
ASAIO J.
, vol.49
, pp. 259-264
-
-
Kosaka, R.1
-
24
-
-
0242301757
-
An advanced physiological controller design for a left ventricular assist device to prevent left ventricular collapse
-
(doi:10. 1046/j.1525-1594.2003.00032.x)
-
Wu, Y., Allaire, P., Tao, G., Wood, H., Olsen, D. & Tribble, C. 2003 An advanced physiological controller design for a left ventricular assist device to prevent left ventricular collapse. Artif. Organs 27, 926-930. (doi:10. 1046/j.1525-1594.2003.00032.x)
-
(2003)
Artif. Organs
, vol.27
, pp. 926-930
-
-
Wu, Y.1
Allaire, P.2
Tao, G.3
Wood, H.4
Olsen, D.5
Tribble, C.6
-
25
-
-
0033017790
-
Motor feedback physiological control for a continuous flow ventricular assist device
-
(doi:10.1046/j.1525-1594. 1999.06386.x)
-
Waters, T. et al. 1999 Motor feedback physiological control for a continuous flow ventricular assist device. Artif. Organs 23, 480-486. (doi:10.1046/j.1525-1594. 1999.06386.x)
-
(1999)
Artif. Organs
, vol.23
, pp. 480-486
-
-
Waters, T.1
-
26
-
-
0025388875
-
Design and control of the atrio-aortic left ventricular assist device based on O2 consumption
-
(doi:10.1109/10.46252)
-
Drzewiecki, G. M., Pilla, J. & Welkowitz, W. 1990 Design and control of the atrio-aortic left ventricular assist device based on O2 consumption. IEEE Trans. Biomed. Eng. 37, 128-137. (doi:10.1109/10.46252)
-
(1990)
IEEE Trans. Biomed. Eng.
, vol.37
, pp. 128-137
-
-
Drzewiecki, G.M.1
Pilla, J.2
Welkowitz, W.3
-
27
-
-
0034326322
-
Mixed venous oxygen saturation as a promising parameter for physiological control of total artificial heart
-
(doi:10.1097/00002480-200011000-00020)
-
Nakamura, M. et al. 2000 Mixed venous oxygen saturation as a promising parameter for physiological control of total artificial heart. ASAIO J. 46, 761-766. (doi:10.1097/00002480-200011000-00020)
-
(2000)
ASAIO J.
, vol.46
, pp. 761-766
-
-
Nakamura, M.1
-
28
-
-
0032975726
-
A new control method that estimates the backflow in a centrifugal pump
-
(doi:10.1046/j.1525-1594.1999.06398.x)
-
Nakata, K., Ohtsuka, G., Ypshikawa, M., Takano, T., Glueck, J., Fujisawa, A., Makinouchi, K., Yokokawa, M. & Nos, Y. 1999 A new control method that estimates the backflow in a centrifugal pump. Artif. Organs 23, 538-541. (doi:10.1046/j.1525-1594.1999.06398.x)
-
(1999)
Artif. Organs
, vol.23
, pp. 538-541
-
-
Nakata, K.1
Ohtsuka, G.2
Ypshikawa, M.3
Takano, T.4
Glueck, J.5
Fujisawa, A.6
Makinouchi, K.7
Yokokawa, M.8
Nos, Y.9
-
29
-
-
33845491760
-
Numerical simulation of cardiovascular dynamics with left heart failure and inseries pulsatile ventricular assist device
-
(doi:10.1111/j.1525-1594.2006.00326.x)
-
Shi, Y. & Korakianitis, T. 2006 Numerical simulation of cardiovascular dynamics with left heart failure and inseries pulsatile ventricular assist device. Artif. Organs 30, 929-948. (doi:10.1111/j.1525-1594.2006.00326.x)
-
(2006)
Artif. Organs
, vol.30
, pp. 929-948
-
-
Shi, Y.1
Korakianitis, T.2
-
30
-
-
85020735237
-
-
See
-
CellML. 2008 See http://www.cellml.org.
-
(2008)
CellML
-
-
-
31
-
-
1342329447
-
An overview of CellML 1.1, a biological model description language
-
(doi:10.1177/0037549703040939)
-
Cuellar, A. A., Lloyd, C. M., Nielsen, P. F., Bullivant, D. P., Nickerson, D. P. & Hunter, P. J. 2003 An overview of CellML 1.1, a biological model description language. Simulation 79, 740-747. (doi:10.1177/0037549703040939)
-
(2003)
Simulation
, vol.79
, pp. 740-747
-
-
Cuellar, A.A.1
Lloyd, C.M.2
Nielsen, P.F.3
Bullivant, D.P.4
Nickerson, D.P.5
Hunter, P.J.6
-
32
-
-
0013971332
-
Energy equivalent pressure
-
Shepard, R., Simpson, D. C. & Sharp, J. 1966 Energy equivalent pressure. Arch. Surg. 93, 730-740.
-
(1966)
Arch. Surg.
, vol.93
, pp. 730-740
-
-
Shepard, R.1
Simpson, D.C.2
Sharp, J.3
-
33
-
-
0032816083
-
Defining pulsatile perfusion: Quantification in terms of energy equivalent pressure
-
(doi:10. 1046/j.1525-1594.1999.06409.x)
-
Undar, A., Frazier, O. H. & Fraser Jr, C. D. 1999 Defining pulsatile perfusion: quantification in terms of energy equivalent pressure. Artif. Organs 23, 712-716. (doi:10. 1046/j.1525-1594.1999.06409.x)
-
(1999)
Artif. Organs
, vol.23
, pp. 712-716
-
-
Undar, A.1
Frazier, O.H.2
Fraser Jr., C.D.3
-
34
-
-
3342991843
-
Reverse remodeling in heart failure-fact or fiction?
-
(doi:10. 1016/j.ehjsup.2004.05.019)
-
Pieske, B. 2004 Reverse remodeling in heart failure-fact or fiction? Eur. Heart J. Suppl. 6, D66-D78. (doi:10. 1016/j.ehjsup.2004.05.019)
-
(2004)
Eur. Heart J. Suppl.
, vol.6
-
-
Pieske, B.1
-
36
-
-
33745826316
-
Numerical simulation of cardiovascular dynamics with healthy and diseased heart valves
-
(doi:10.1016/j.jbiomech. 2005.06.016)
-
Korakianitis, T. & Shi, Y. 2006 Numerical simulation of cardiovascular dynamics with healthy and diseased heart valves. J. Biomech. 39, 1964-1982. (doi:10.1016/j.jbiomech. 2005.06.016)
-
(2006)
J. Biomech.
, vol.39
, pp. 1964-1982
-
-
Korakianitis, T.1
Shi, Y.2
-
38
-
-
34249011417
-
Design features, developmental status, and experimental results with the Heartmate III centrifugal left ventricular assist system with a magnetically levitated rotor
-
(doi:10. 1097/MAT.0b013e3180536694)
-
Farrar, D. J., Bourque, K., Dague, C. P., Cotter, C. J. & Poirier, V. L. 2007 Design features, developmental status, and experimental results with the Heartmate III centrifugal left ventricular assist system with a magnetically levitated rotor. ASAIO J. 53, 310-315. (doi:10. 1097/MAT.0b013e3180536694)
-
(2007)
ASAIO J.
, vol.53
, pp. 310-315
-
-
Farrar, D.J.1
Bourque, K.2
Dague, C.P.3
Cotter, C.J.4
Poirier, V.L.5
-
39
-
-
34249014596
-
Effect of continuous and pulsatile flow left ventricular assist on pulsatility in a pediatric animal model of left ventricular dysfunction: Pilot observations
-
(doi:10.1097/MAT. 0b013e318050d210)
-
Pantalos, G. M., Giridharan, G., Colyer, J., Mitchell, M., Speakman, J., Lucci, C., Johnson, G., Gartner, M. & Koenig, S. C. 2007 Effect of continuous and pulsatile flow left ventricular assist on pulsatility in a pediatric animal model of left ventricular dysfunction: pilot observations. ASAIO J. 53, 385-391. (doi:10.1097/MAT. 0b013e318050d210)
-
(2007)
ASAIO J.
, vol.53
, pp. 385-391
-
-
Pantalos, G.M.1
Giridharan, G.2
Colyer, J.3
Mitchell, M.4
Speakman, J.5
Lucci, C.6
Johnson, G.7
Gartner, M.8
Koenig, S.C.9
-
40
-
-
0031871850
-
The type of aortic cannula and membrane oxygenator affect the pulsatile waveform morphology produced by a neonate-infant cardiopulmonary bypass system in vivo
-
(doi:10.1046/j.1525-1594. 1998.06017.x)
-
Undar, A., Lodge, A. J., Daggett, C. W., Runge, T. M., Ungerleider, R. M. & Calhoon, J. H. 1998 The type of aortic cannula and membrane oxygenator affect the pulsatile waveform morphology produced by a neonate-infant cardiopulmonary bypass system in vivo. Artif. Organs 22, 681-686. (doi:10.1046/j.1525-1594. 1998.06017.x)
-
(1998)
Artif. Organs
, vol.22
, pp. 681-686
-
-
Undar, A.1
Lodge, A.J.2
Daggett, C.W.3
Runge, T.M.4
Ungerleider, R.M.5
Calhoon, J.H.6
|