메뉴 건너뛰기




Volumn 30, Issue 12, 2006, Pages 929-948

Numerical simulation of cardiovascular dynamics with left heart failure and in-series pulsatile ventricular assist device

Author keywords

Cardiovascular dynamics; Heart failure; Heart valve dynamics; Numerical simulation; Pulsatile; Ventricular assist device; Ventricular dysfunction

Indexed keywords

DYNAMICS; FIBER OPTIC SENSORS; HEART; NUMERICAL MODELS; OUTAGES;

EID: 33845491760     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2006.00326.x     Document Type: Article
Times cited : (47)

References (25)
  • 1
    • 0033938026 scopus 로고    scopus 로고
    • Blood pumps for circulation support
    • Reul HM, Akdis M. Blood pumps for circulation support. Perfusion 2000;15:295-311.
    • (2000) Perfusion , vol.15 , pp. 295-311
    • Reul, H.M.1    Akdis, M.2
  • 2
    • 0348047551 scopus 로고    scopus 로고
    • Unloading effect of a rotary blood pump assessed by mathematical modeling
    • Vandenberghe S, Segers P, Meyns B, Verdonck P. Unloading effect of a rotary blood pump assessed by mathematical modeling. Artif Organs 2003;27:1094-101.
    • (2003) Artif Organs , vol.27 , pp. 1094-1101
    • Vandenberghe, S.1    Segers, P.2    Meyns, B.3    Verdonck, P.4
  • 3
    • 26444543353 scopus 로고    scopus 로고
    • Coupling pediatric ventricle assist devices to the fontan circulation: Simulation with a lumped-parameter model
    • Pekkan K, Frakes D, de Zelicourt D, Lucas CW, Parks WJ, Yoganathan AP. Coupling pediatric ventricle assist devices to the fontan circulation: simulation with a lumped-parameter model. ASAIO J 2005;51:618-28.
    • (2005) ASAIO J , vol.51 , pp. 618-628
    • Pekkan, K.1    Frakes, D.2    De Zelicourt, D.3    Lucas, C.W.4    Parks, W.J.5    Yoganathan, A.P.6
  • 4
    • 0036798185 scopus 로고    scopus 로고
    • End-organ function during chronic nonpulsatile circulation
    • Saito S, Westaby S, Piggot D, et al. End-organ function during chronic nonpulsatile circulation. Ann Thorac Surg 2002;74:1080-5.
    • (2002) Ann Thorac Surg , vol.74 , pp. 1080-1085
    • Saito, S.1    Westaby, S.2    Piggot, D.3
  • 5
    • 0030783134 scopus 로고    scopus 로고
    • The relation between pump flow rate and pulsatility on cerebral hemodynamics during pediatric cardiopulmonary bypass
    • Chow G, Roberts IG, Edwards AD,et al. The relation between pump flow rate and pulsatility on cerebral hemodynamics during pediatric cardiopulmonary bypass. J Thorac Cardiovasc Surg 1997;114:568-77.
    • (1997) J Thorac Cardiovasc Surg , vol.114 , pp. 568-577
    • Chow, G.1    Roberts, I.G.2    Edwards, A.D.3
  • 6
    • 0032974674 scopus 로고    scopus 로고
    • Major organ function under mechanical support: Comparative studies of pulsatile and nonpulsatile circulation
    • Sezai A, Shiono M, Orime Y, et al. Major organ function under mechanical support: comparative studies of pulsatile and nonpulsatile circulation. Artif Organs 1999;23:280-5.
    • (1999) Artif Organs , vol.23 , pp. 280-285
    • Sezai, A.1    Shiono, M.2    Orime, Y.3
  • 8
    • 2542419343 scopus 로고    scopus 로고
    • Myths and truths of pulsatile and nonpulsatile perfusion during acute and chronic cardisc support
    • Ündar A. Myths and truths of pulsatile and nonpulsatile perfusion during acute and chronic cardisc support. Artif Organs 2004;28:439-43.
    • (2004) Artif Organs , vol.28 , pp. 439-443
    • Ündar, A.1
  • 9
    • 0034535141 scopus 로고    scopus 로고
    • Numerical simulation of the influence of a left ventricular assist device on the cardiovascular system
    • Verkerke GJ, Geertsema AA, Mihaylov D, Blanksma PK, Rakhorst G. Numerical simulation of the influence of a left ventricular assist device on the cardiovascular system. Int J Artif Organs 2000;23:765-73.
    • (2000) Int J Artif Organs , vol.23 , pp. 765-773
    • Verkerke, G.J.1    Geertsema, A.A.2    Mihaylov, D.3    Blanksma, P.K.4    Rakhorst, G.5
  • 11
    • 0028401557 scopus 로고
    • A desk-top computer model of the circulatory system for heart assistance simulation: Effect of an LVAD on energetic relationships inside the left ventricle
    • De Lazzari C, Mimmo FR, Tosti G, Ambrosi D. A desk-top computer model of the circulatory system for heart assistance simulation: effect of an LVAD on energetic relationships inside the left ventricle. Med Eng Phys 1994;16:97-103.
    • (1994) Med Eng Phys , vol.16 , pp. 97-103
    • De Lazzari, C.1    Mimmo, F.R.2    Tosti, G.3    Ambrosi, D.4
  • 12
    • 0025388796 scopus 로고
    • Cardiac energy considerations during intraaortic balloon pumping
    • Barnea O, Moore TW, Dubin S, Jaron D. Cardiac energy considerations during intraaortic balloon pumping. IEEE Trans Biomed Eng 1990;17:170-81.
    • (1990) IEEE Trans Biomed Eng , vol.17 , pp. 170-181
    • Barnea, O.1    Moore, T.W.2    Dubin, S.3    Jaron, D.4
  • 13
    • 0036240115 scopus 로고    scopus 로고
    • Interaction of the cardiovascular system with an implanted rotary assist device: Simulation study with a refined computer model
    • Vollkron M, Shima H, Huber L, Wieselthaler G. Interaction of the cardiovascular system with an implanted rotary assist device: simulation study with a refined computer model. Artif Organs 2002;26:349-59.
    • (2002) Artif Organs , vol.26 , pp. 349-359
    • Vollkron, M.1    Shima, H.2    Huber, L.3    Wieselthaler, G.4
  • 15
    • 84872918841 scopus 로고    scopus 로고
    • Reciprocating pumps and linear motor arrangement
    • Patent No.: US 5,879,375, United States Patent, March 9
    • Larson CO, Smith JS, Chapman JH, et al. Reciprocating pumps and linear motor arrangement. Patent No.: US 5,879,375, United States Patent, March 9 1999.
    • (1999)
    • Larson, C.O.1    Smith, J.S.2    Chapman, J.H.3
  • 16
    • 33845498254 scopus 로고    scopus 로고
    • Optimized pulsatile flow ventricular assistance device and total artificial heart
    • Patent No.: US 6,632,169, United States Patent, October 14
    • Korakianitis T, Grandia L. Optimized pulsatile flow ventricular assistance device and total artificial heart. Patent No.: US 6,632,169, United States Patent, October 14, 2003.
    • (2003)
    • Korakianitis, T.1    Grandia, L.2
  • 17
    • 0015594766 scopus 로고
    • Load independence of the instantaneous pressure-volume ratio of the canine left ventricle and effects of epinephrine and heart rate on the ratio
    • Suga H, Sagawa K, Shoukas AA. Load independence of the instantaneous pressure-volume ratio of the canine left ventricle and effects of epinephrine and heart rate on the ratio. Circ Res 1973;XXXII:314-22.
    • (1973) Circ Res , vol.32 , pp. 314-322
    • Suga, H.1    Sagawa, K.2    Shoukas, A.A.3
  • 18
    • 0037212420 scopus 로고    scopus 로고
    • A three-dimensional computational analysis of fluid-structure interaction in the aortic valve
    • De Hart J, Paters GWM, Schreurs PJG, Baaijens FPT. A three-dimensional computational analysis of fluid-structure interaction in the aortic valve. J Biomech 2003;36:103-12.
    • (2003) J Biomech , vol.36 , pp. 103-112
    • De Hart, J.1    Paters, G.W.M.2    Schreurs, P.J.G.3    Baaijens, F.P.T.4
  • 19
    • 0037356105 scopus 로고    scopus 로고
    • Numerical simulation of opening process in a bileaflet mechanical heart valve under pulsatile flow condition
    • Shi YB, Zhao Y, Yeo JH, Hwang NHC. Numerical simulation of opening process in a bileaflet mechanical heart valve under pulsatile flow condition. J Heart Valve Dis 2003;12:245-56.
    • (2003) J Heart Valve Dis , vol.12 , pp. 245-256
    • Shi, Y.B.1    Zhao, Y.2    Yeo, J.H.3    Hwang, N.H.C.4
  • 20
    • 0342649244 scopus 로고
    • The fluid mechanics of heart valves
    • Bergel DH, eds, Chapter 8. London: Academic Press
    • Bellhouse BJ. The fluid mechanics of heart valves. In: Bergel DH, eds, Cardiovascular Fluid Dynamics, Vol. 1, Chapter 8. London: Academic Press, 1972;261-85.
    • (1972) Cardiovascular Fluid Dynamics , vol.1 , pp. 261-285
    • Bellhouse, B.J.1
  • 21
    • 0032925524 scopus 로고    scopus 로고
    • A mathematical model of the carotid baroregulation in pulsating conditions
    • Ursino M. A mathematical model of the carotid baroregulation in pulsating conditions. IEEE Trans Biomed Eng 1999;46:382-92.
    • (1999) IEEE Trans Biomed Eng , vol.46 , pp. 382-392
    • Ursino, M.1
  • 25
    • 3843123057 scopus 로고    scopus 로고
    • New aspects on the role of blood pressure and arterial stiffness in mechanical assistance by intra-aortic balloon pump: In-vitro data and their application in clinical practice
    • Papaioannou TG, Mathioulakis DS, Stamatelopoulos KS, et al. New aspects on the role of blood pressure and arterial stiffness in mechanical assistance by intra-aortic balloon pump: in-vitro data and their application in clinical practice. Artif Organs 2004;28:717-27.
    • (2004) Artif Organs , vol.28 , pp. 717-727
    • Papaioannou, T.G.1    Mathioulakis, D.S.2    Stamatelopoulos, K.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.