메뉴 건너뛰기




Volumn 10, Issue , 2011, Pages

Neonatal non-contact respiratory monitoring based on real-time infrared thermography

Author keywords

[No Author keywords available]

Indexed keywords

BREATHING SIGNALS; CONTINUOUS WAVELET TRANSFORMATION; ENGINEERING APPLICATIONS; IMAGE STREAMS; MEDICAL SENSORS; MONITORING SYSTEM; MULTIPLE PARAMETERS; NEONATAL INTENSIVE CARE UNITS; NON-CONTACT; NON-CONTACT MONITORING; PHYSIOLOGICAL MEASUREMENT; REGION OF INTEREST; RESPIRATION MONITORING; RESPIRATION RATE; RESPIRATORY MONITORING; TEMPERATURE DIFFERENCES; TEMPERATURE PROFILES; VITAL PARAMETERS; VITAL SIGNALS; WAVELET FUNCTION;

EID: 84860811459     PISSN: None     EISSN: 1475925X     Source Type: Journal    
DOI: 10.1186/1475-925X-10-93     Document Type: Article
Times cited : (185)

References (33)
  • 1
    • 70649103100 scopus 로고    scopus 로고
    • Thermal infrared imaging: A novel method to monitor airflow during polysomnography
    • Murthy JN, van Jaarsveld J, Fei J, Pavlidis I, Harrykissoon R, Lucke. Thermal infrared imaging: A novel method to monitor airflow during polysomnography. SLEEP 2009, 32:15211527.
    • (2009) SLEEP , vol.32 , pp. 15211527
    • Murthy, J.N.1    van Jaarsveld, J.2    Fei, J.3    Pavlidis, I.4    Harrykissoon, R.5    Lucke6
  • 8
    • 33645016345 scopus 로고    scopus 로고
    • Non-invasive estimation of arterial blood pH using exhaled CO/CO2 analyzer, microwave radar and infrared thermography for patients after massive hemorrhage
    • 10.1080/03091900500062158, 16531349
    • Matsui T, Hattori H, Takase B, Ishihara M. Non-invasive estimation of arterial blood pH using exhaled CO/CO2 analyzer, microwave radar and infrared thermography for patients after massive hemorrhage. J Med Eng Technol 2006, 30:97-101. 10.1080/03091900500062158, 16531349.
    • (2006) J Med Eng Technol , vol.30 , pp. 97-101
    • Matsui, T.1    Hattori, H.2    Takase, B.3    Ishihara, M.4
  • 9
    • 0036011157 scopus 로고    scopus 로고
    • The OxyArm - a new minimal contact oxygen delivery system for mouth or nose breathing
    • 10.1007/BF03020531, 11861350
    • Ling E, McDonald L, Dinesen TJR, DuVall D. The OxyArm - a new minimal contact oxygen delivery system for mouth or nose breathing. Can J Anaesth 2002, 49(3):297-301. 10.1007/BF03020531, 11861350.
    • (2002) Can J Anaesth , vol.49 , Issue.3 , pp. 297-301
    • Ling, E.1    McDonald, L.2    Dinesen, T.J.R.3    DuVall, D.4
  • 10
    • 84883847099 scopus 로고    scopus 로고
    • Respiratory monitoring system on the basis of capacitive textile force sensor
    • Hoffmann T, Eilbrecht B, Leonhardt S. Respiratory monitoring system on the basis of capacitive textile force sensor. IEEE transaction of sensors 2010, 27.
    • (2010) IEEE transaction of sensors , pp. 27
    • Hoffmann, T.1    Eilbrecht, B.2    Leonhardt, S.3
  • 11
    • 0034867841 scopus 로고    scopus 로고
    • Development of real-time image sequence analysis for evaluating posture change and respiratory rate of a subject in bed
    • Nakajim K, Matsumoto Y, Tamura T. Development of real-time image sequence analysis for evaluating posture change and respiratory rate of a subject in bed. Physiological Measurement 2001, 22(2):N21-N28.
    • (2001) Physiological Measurement , vol.22 , Issue.2
    • Nakajim, K.1    Matsumoto, Y.2    Tamura, T.3
  • 18
    • 0036880526 scopus 로고    scopus 로고
    • Thermal image analysis for polygraph testing
    • 10.1109/MEMB.2002.1175139, 12613212
    • Pavilidis I, Levine J. Thermal image analysis for polygraph testing. IEEE Engineering in Medicine and Biology Magazine 2002, 21(6):56-64. 10.1109/MEMB.2002.1175139, 12613212.
    • (2002) IEEE Engineering in Medicine and Biology Magazine , vol.21 , Issue.6 , pp. 56-64
    • Pavilidis, I.1    Levine, J.2
  • 20
    • 77950132860 scopus 로고    scopus 로고
    • Non-contact monitoring of breathing function using infrared imaging
    • Technical report in Biomedical engineering Number UH-CS-05-09, University of Houston
    • Murthy R, Pavlidis I. Non-contact monitoring of breathing function using infrared imaging. 2005, Technical report in Biomedical engineering Number UH-CS-05-09, University of Houston.
    • (2005)
    • Murthy, R.1    Pavlidis, I.2
  • 24
    • 77950321911 scopus 로고    scopus 로고
    • Thermistor at a distance: unobtrusive measurement of breathing
    • Fei J, Pavlidis I. Thermistor at a distance: unobtrusive measurement of breathing. IEEE Trans Biomed Eng 2010, 57(4):988-998.
    • (2010) IEEE Trans Biomed Eng , vol.57 , Issue.4 , pp. 988-998
    • Fei, J.1    Pavlidis, I.2
  • 27
    • 77950321911 scopus 로고    scopus 로고
    • Thermistor at a distance: unobtrusive measurement of breathing
    • Fei J, Pavlidis I. Thermistor at a distance: unobtrusive measurement of breathing. IEEE Trans Biomed Eng 2010, 57(4):988-998., http://dx.doi.org/10.1109/TBME.2009.2032415
    • (2010) IEEE Trans Biomed Eng , vol.57 , Issue.4 , pp. 988-998
    • Fei, J.1    Pavlidis, I.2
  • 28
    • 84883839805 scopus 로고    scopus 로고
    • The evolution in spatial resolution
    • Danjoux R. The evolution in spatial resolution. InfraMation Magazine 2001, 2(12):1-3.
    • (2001) InfraMation Magazine , vol.2 , Issue.12 , pp. 1-3
    • Danjoux, R.1
  • 31
    • 0035131249 scopus 로고    scopus 로고
    • Skin-to-skin (kangaroo) care, respiratory control, and thermoregulation
    • 10.1067/mpd.2001.110978, 11174616
    • Bohnhorst B, Heyne T, Peter C, Poet S. Skin-to-skin (kangaroo) care, respiratory control, and thermoregulation. J Pediatr 2001, 138:193-197. 10.1067/mpd.2001.110978, 11174616.
    • (2001) J Pediatr , vol.138 , pp. 193-197
    • Bohnhorst, B.1    Heyne, T.2    Peter, C.3    Poet, S.4
  • 32
    • 5144222411 scopus 로고    scopus 로고
    • Bradycardia and desaturation during skin-to-skin care: no relationship to hyperthermia
    • Bohnhorst B, Gill D, Drdelmann M, Peter C, Poets C. Bradycardia and desaturation during skin-to-skin care: no relationship to hyperthermia. J Pediatrics 2004, 145:499-502.
    • (2004) J Pediatrics , vol.145 , pp. 499-502
    • Bohnhorst, B.1    Gill, D.2    Drdelmann, M.3    Peter, C.4    Poets, C.5
  • 33
    • 70350553968 scopus 로고    scopus 로고
    • Impact of skin-to-skin care, prone and supine positioning on cardio respiratory parameters and thermoregulation in premature infants
    • Heimann K, Vaen P, Peschgens T, Stanzel S, Wenzl T, Orlikowsky T. Impact of skin-to-skin care, prone and supine positioning on cardio respiratory parameters and thermoregulation in premature infants. Neonatology 2010 2010, 97:311-317.
    • (2010) Neonatology 2010 , vol.97 , pp. 311-317
    • Heimann, K.1    Vaen, P.2    Peschgens, T.3    Stanzel, S.4    Wenzl, T.5    Orlikowsky, T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.